• 제목/요약/키워드: Coverage Distance

검색결과 206건 처리시간 0.023초

붐방제기 살포장치의 설계요인 구명을 위한 실험적 연구(II) -노즐의 분무유형 및 벼의 피복특성- (Design Factors of Boom Sprayer(II) -Spray Droplet Size and Coverage Characteristics on Rice Plants-)

  • 정창주;김학진;이중용;최영수;최중섭
    • Journal of Biosystems Engineering
    • /
    • 제20권4호
    • /
    • pp.313-322
    • /
    • 1995
  • This study was conducted to find the design factors of spraying device of the boom sprayer for low volume application. Specific objectives of this study were 1) to select proper nozzles for broadcast spraying and row crop spraying by the nozzle spray characterisic experiment, and 2) to investigate the coverage characteristic of rice plant at the row crop spraying. The results of this study are summarized as follows. (1) From the tested results on the droplet diameter spectrum and spray pattern the standard flat-fan nozzle and drift guard nozzle were judged as appropriate for the broadcasting. Even flat-fan nozzle showed similar span values to standard flat-fan nozzles and drift guard nozzle : however, the nozzles were found to be inappropriate for broadcasting because of their spray pattern. Hollow cone nozzle showed relatively small span values and uniform spray pattern. (2) For the upper and lower sides of the rice plants, coverage rates of even flat-fan nozzles and hollow cone nozzles were maximum at the second row, but decreased rapidly after the third row. For the middle side of the rice plants, coverage rates of them were maximum at the first row, but decreased rapidly. When one nozzle was tested, C.V. values were in the range of 90~160% and 60~160% on entire heights of rice plant for even flat-fan nozzles and hollow cone nozzles respectively. C.V. values at other parts were poor. Spray coverage rate at the middle part was improved by overlapping the nozzles whereas there was little difference on the upper and lower part of rice plants. (3) For spraying lower part of rice plant between rows, even flat-fan nozzles and hollow cone nozzle were judged as appropriate, but in order to ensure the uniform coverage, distance between nozzles, recommended to be less than 90cm.

  • PDF

Push-Pull Distributed Movement Algorithm toy An Optimized Coverage of Mobile Base Station in Topology-less Wireless Networks

  • Unhawiwat, Mallika;Wipusitwarakun, Komwut
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -3
    • /
    • pp.1936-1939
    • /
    • 2002
  • Much recent attention on wireless technologies s put on topology-less wireless network, in which all nodes an be mobile and can communicate over wireless links, due to its ease of deployment, high flexibility and low expenses. One key in topology-less wireless network is mobile base stations (MBSs), which provides access points or mobile terminals (MTs) to wireless backbone network. MBSs can move to anywhere in accordance with changes in geographical distribution of MTs. They serve as dynamic odes. However, in order to utilize network resources and take full advantage of this topology-less network, MBSs must move to suitable position according to the current tate of network use. Moreover, MBSs have to consider the distance among them to avoid the crash and gap area of MBSs. Therefore, this paper proposes MBS movement algorithm by implementing push-pull method to fulfill the corporation of MBSs and considering the center of covered MTs or centroid to satisfy the MT coverage. From the simulation results, the proposed algorithm increases the performance of system when comparing with the centroid-based algoriom〔7〕, such as coverage area, MT coverage and call drops rate.

  • PDF

정전용량변화를 이용한 링거액소진감지장치의 구현 (Implementation of apparatus for detecting Ringer's solution exhaustion using electrostatic capacitance variation)

  • 김청월
    • 센서학회지
    • /
    • 제19권1호
    • /
    • pp.1-7
    • /
    • 2010
  • Electrostatic capacitance measurement method in a fine hose was proposed, in which two ring-type electrodes were disposed on the hose in the direction of fluid flow instead of the conventional face-to-face electrodes. With the proposed electrode structure, we realized a Ringer's solution exhaustion detector for an IV(invasive vein) injection set. On a 4 mm-diameter hose of IV set, we disposed two ring-type electrodes of 10 mm width at a distance of 5 mm each other and obtained 0.72 pF and 2.51 pF for air and 10 % dextrose Ringer's solution in the hose, respectively. The capacitance between the two electrodes varied with the hose-wraparound coverage of electrode as well as the width of electrode and the distance between the electrodes. For hose-wraparound electrode coverage of 75 %, the capacitance varied from 0.62 pF to 1.98 pF with the Ringer's solution level between the two electrodes. A charge amplifier converted the capacitance. variation into electric signal and a comparator was used to detect whether Ringer's solution was exhausted or not. The result was delivered to a host using a RF transmitter with 320 MHz carrier frequency.

농촌마을 담장정비를 위한 설치환경 특성 분석 (Analysis on Characteristics of Installing Environment for Improvement of Boundary Barriers in Rural Villages)

  • 임종현;조은정;최수명;김상철
    • 농촌계획
    • /
    • 제21권1호
    • /
    • pp.89-102
    • /
    • 2015
  • With the basic research logic stating that the systematic improvement of rural housing plot's boundary barriers should call for the integrated consideration of their on-and-around installing settings, this study tries to analyse characteristics of installing environment of boundary barriers for improvement works of them. Through literature review and then screening process, 3 influencing and appraisal factors were determined: main house-boundary barrier shortest distance as on-site factor, building coverage as inside one, and attached road width as outside one. 21 study villages were subgrouped into structurally improved(9) and not(12). Site investigation and analysis results showed that the relationship between factors has varied very much, i.e. in some cases it is positive or complementary, but in other cases, negative or crossed. Therefore this study would propose that differentiated and flexible strategies with integrated consideration of on-and-around site installing settings be applied in their improvement projects rather than village-wide unified or straight forwarded ones.

Interference Aware Fractional Frequency Reuse using Dynamic User Classification in Ultra-Dense HetNets

  • Ban, Ilhak;Kim, Se-Jin
    • 인터넷정보학회논문지
    • /
    • 제22권5호
    • /
    • pp.1-8
    • /
    • 2021
  • Small-cells in heterogeneous networks are one of the important technologies to increase the coverage and capacity in 5G cellular networks. However, due to the randomly arranged small-cells, co-tier and cross-tier interference increase, deteriorating the system performance of the network. In order to manage the interference, some channel management methods use fractional frequency reuse(FFR) that divides the cell coverage into the inner region(IR) and outer region(OR) based on the distance from the macro base station(MBS). However, since it is impossible to properly measure the distance in the method with FFR, we propose a new interference aware FFR(IA-FFR) method to enhance the system performance. That is, the proposed IA-FFR method divides the MUEs and SBSs into the IR and OR groups based on the signal to interference plus noise ratio(SINR) of macro user equipments(MUEs) and received signals strength of small-cell base stations(SBSs) from the MBS, respectively, and then dynamically assigns subchannels to MUEs and small-cell user equipments. As a result, the proposed IA-FFR method outperforms other methods in terms of the system capacity and outage probability.

절단피개량과 절단변연형태 및 하중각도가 도재라미네이트 베니어 내의 응력분포에 미치는 영향에 관한 삼차원 유한요소법적 연구 (THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION IN PORCELAIN LAMINATE VENEERS WITH VARIOUS AMOUNTS OF INCISAL COVERAGE AND TYPES OF INCISAL FINISH LINE UNDER TWO LOADING CONDITIONS)

  • 류경희;이선형;양재호;정헌영
    • 대한치과보철학회지
    • /
    • 제37권2호
    • /
    • pp.143-166
    • /
    • 1999
  • The success of porcelain laminate veneer depends on the bond strength between tooth structure and ceramic restoration and the design of tooth preparation. In particular, incisal coverage and incisal finish line are the two most important factors in long-term fracture resistance. Although the majority of clinicians are practicing incisal coverage and there are various opinions on the geo-metrical ratio between the clinical crown length of the remaining tooth structure and the length of incisal extension in porcelain laminate veneer and the optimal incisal finish lines. scientific evidence still loaves much to be desired. The purpose of this study was to determine the effects of the amounts of incisal coverage and the types of incisal finish line on the stress distribution in maxillary anterior porcelain laminate veneers under two different loading conditions. Three-dimensional finite element models of a maxillary anterior porcelain veneer with differ-ent amounts of incisal coverage ; 0, 1, 2, and 3mm and different incisal finish lines feathered edge, incisal bevel, reverse bevel and lingual chamfer with various amounts of lingual extension were developed. 300N force was applied at the point 0.5mm cervical of the linguoincisal edge in two loading conditions ; A) 125 degrees, B) 132 degrees. Tensile and compressive stress in ceramic and shear stress in the resin cement layer were analyzed using three-dimensional finite element method. The results were as follows : 1. The types of incisal finish line had more influence on the stress distribution in porcelain laminate veneer than the amounts of incisal coverage. 2. In case of no incisal coverage, incisal beveled laminate exhibited more evenly distributed tensile stress than feathered edged laminate. And in case of incisal coverage, reverse beveled laminate and lingual chamfered laminate with 1mm lingual extension exhibited more evenly distributed tensile stress than lingual chamfered laminates with 2mm and 3mm lingual extension. 3. As long as the lingual chamfer goes, less tensile stress was found at the incisal edge, while much more tensile stress was found at the lingual margin area in proportion to the length of lingual extension. 4. Under 125 degree load, tensile stress in porcelain laminate veneer had increased compared with that under 132 degree load and the difference exhibited by the change of the amount of tooth support was larger. 5. The types of incisal finish line and the distance from the incisal finish line to the loading point had more influence on the shear stress distribution in the resin cement layer than the amounts of incisal coverage. In contrast loading condition had little influence.

  • PDF

3GPP 협대역 사물인터넷 시스템에서 단말의 특징을 고려한 커버리지 클래스 적응 기법 (Coverage Class Adaptation Schemes Considering Device Characteristics in a 3GPP Narrowband IoT System)

  • 남유진;소재우;나민수;최창순
    • 한국통신학회논문지
    • /
    • 제41권9호
    • /
    • pp.1026-1037
    • /
    • 2016
  • 3GPP (3rd Generation Partnership Project)에서는 IoT (Internet of Things) 서비스의 제공을 위해 초다수의 단말을 지원할 수 있는 NB-IoT (narrowband IoT) 시스템 표준화를 진행 중이다. NB-IoT 시스템은 넓은 커버리지 내 초다수의 단말들을 서비스하면서 시스템의 성능을 향상시키기 위해 커버리지 클래스를 사용하며, 이를 위해 이동 중인 단말은 기지국과 단말 사이의 채널 환경이나 거리 등과 같은 커버리지 클래스 변경 기준에 따라 커버리지 클래스를 변경한다. 하지만 종래의 NB-IoT 시스템 표준에서 단말은 고정된 커버리지 클래스 변경 기준을 사용하기 때문에 이동 중인 단말이 커버리지 클래스를 변경하는 경우 시스템 성능이 열화 된다. 본 논문에서는 IoT 단말의 위치 또는 채널 상태에 따라 동적으로 커버리지 클래스를 변경함으로써 NB-IoT 시스템의 성능을 향상시키는 커버리지 클래스 변경 기법을 제안한다. 시뮬레이션을 통해 제안하는 커버리지 클래스 변경 기법이 기존 커버리지 클래스 변경 기법 대비 시그널링 오버헤드와 PDCCH 디코딩 오류율을 모두 감소시키는 것을 확인하였다.

Edge effects confirmed at the clear-cut area of Korean red pine forest in Uljin, eastern Korea

  • Jung, Song Hie;Lim, Chi Hong;Kim, A Reum;Woo, Dong Min;Kwon, Hye Jin;Cho, Yong Chan;Lee, Chang Seok
    • Journal of Ecology and Environment
    • /
    • 제41권10호
    • /
    • pp.290-301
    • /
    • 2017
  • Background: Forest edges create distinctive ecological space as adjacent constituents, which distinguish between different ecosystems or land use types. These edges are made by anthropogenic or natural disturbance and affects both abiotic and biotic factors gradually. This study was carried out to assess edge effects on disturbed landscape at the pine-dominated clear-cut area in a genetic resources reserve in Uljin-gun, eastern Korea. This study aims to estimate the distance of edge influence by analyzing changes of abiotic and biotic factors along the distance from forest edge. Further, we recommend forest management strategy for sustaining healthy forest landscapes by reducing effects of deforestation. Results: Distance of edge effect based on the abiotic factors varied from 8.2 to 33.0 m. The distances were the longest in $Mg^{2+}$ content and total nitrogen, $K^+$, $Ca^{2+}$ contents, canopy openness, light intensity, air humidity, $Na^+$ content, and soil temperature followed. The result based on biotic factors varied from 6.8 to 29.5 m, coverage of tree species in the herb layer showed the longest distance and coverage of shrub plant in the herb layer, evenness, species diversity, total coverage of herb layer, and species richness followed. As the result of calculation of edge effect by synthesizing 26 factors measured in this study, the effect was shown from 11.0 m of the forest interior to 22.4 m of the open space. In the result of stand ordination, Rhododendron mucronulatum, R. schlippenbachii, and Fraxinus sieboldiana dominated arrangement of forest interior sites and Quercus mongolica, Vitis amurensis, and Rubus crataegifolius dominated spatial distribution of the open area plots. Conclusions: Forest interior habitat lies within the influence of both abiotic and biotic edge effects. Therefore, we need a forest management strategy to sustain the stability of the plant and further animal communities that depend on its stable conditions. For protecting forest interior, we recommend selective logging as a harvesting method for minimizing edge effects by anthropogenic disturbance. In fact, it was known that selective logging contributes to control light availability and wind regime, which are key factors affecting microclimate. In addition, ecological restoration applying protective planting for the remaining forest in the clear-cut area could contribute to prevent continuous disturbance in forest interior.

IEC 61850 기반 후비보호계전시스템 보호협조 개선방안 (Improved Coordination Method for Back-up Protection Schemes Based on IEC 61850)

  • 김형규;강상희
    • 전기학회논문지
    • /
    • 제60권1호
    • /
    • pp.43-49
    • /
    • 2011
  • A distance relay scheme is commonly used for backup protection. This scheme, called a step distance protection, is comprised of 3 steps for graded zones having different operating time. As for the conventional step distance protection scheme, Zone 2 can exceed the ordinary coverage excessively in case of a transformer protection relay especially. In this case, there can be overlapped protection area from a backup protection relay and, therefore, malfunctions can occur when any fault occurs in the overlapped protection area. Distance relays and overcurrent relays are used for backup protection generally, and both relays have normally this problem, the maloperation, caused by a fault in the overlapped protection area. Corresponding to an IEEE standard, this problem can be solved with the modification of the operating time. On the other hand, in Korea, zones are modified to cope with this problem in some specific conditions. These two methods may not be obvious to handle this problem correctly because these methods, modifying the common rules, can cause another coordination problem. To overcome this problem clearly, this paper describes an improved backup protection coordination scheme using an IEC 61850-based distance relay for transformer backup protection. IEC 61850-based IED(Intelligent Electronic Device) and the network system based on the kernel 2.6 LINUX are realized to verify the proposed method. And laboratory tests to estimate the communication time show that the proposed coordination method is reliable enough for the improved backup protection scheme.

펨토셀 기반 계층셀 구조 시스템 용량 및 서비스 반경 분석 (System Capacity and Coverage Analysis of Hierarchical Femtocell Networks)

  • 오남걸;김훈
    • 한국통신학회논문지
    • /
    • 제34권6A호
    • /
    • pp.476-483
    • /
    • 2009
  • 최근 들어 실내에서의 고속 무선 통신과 음영지역 해소를 위한 해결책의 하나로 옥내용 기지국인 펨토셀(femtocell)을 활용하는 계층구조 방안이 제시되고 있으며, 이동통신 표준화 단체에서 관련 이슈에 대한 표준화 작업이 활발히 진행되고 있다. 그러나 펨토셀 환경에서 발생할 수 있는 여러 가지 기술적 문제들이 존재하며 그 중 가장 중요한 문제가 간섭으로 인한 시스템의 열화이다. 따라서 전체 시스템의 안정적이고 효율적인 운용을 위해 펨토셀 환경에서의 상호 간섭과 이에 따른 시스템 성능 분석이 요구된다. 본 고에서는 펨토셀 설치 주변의 다양한 전파 환경을 고려하여 매크로셀(macrocell)이나 펨토셀간 상호 간섭에 따른 시스템 용량 및 서비스 영역을 살펴본다. 특히 펨토셀의 주 설치 지역이 되는 실내 환경에서 매크로셀과 펨토셀간의 거리, 펨토셀 내에서 사용자의 위치, 옥내 구조물의 특징 등을 반영한 의전파전파 모델을 적용하고 그에 따른 주파수 효율성과 서비스 반경 등의 시스템 성능을 분석한다.