• Title/Summary/Keyword: Cover rates

Search Result 195, Processing Time 0.026 seconds

Improvement of Steganalysis Using Multiplication Noise Addition (곱셉 잡음 첨가를 이용한 스테그분석의 성능 개선)

  • Park, Tae-Hee;Eom, Il-Kyu
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.49 no.4
    • /
    • pp.23-30
    • /
    • 2012
  • This paper proposes an improved steganalysis method to detect the existence of secret message. Firstly, we magnify the small stego noise by multiplying the speckle noise to a given image and then we estimate the denoised image by using the soft thresholding method. Because the noises are not perfectly eliminated, some noises exist in the estimated cover image. If the given image is the cover image, then the remained noise will be very small, but if it is the stego image, the remained noise will be relatively large. The parent-child relationship in the wavelet domain will be slighty broken in the stego image. From this characteristic, we extract the joint statistical moments from the difference image between the given image and the denoised image. Additionally, four statistical moments are extracted from the denoised image for the proposed steganalysis method. All extracted features are used as the input of MLP(multilayer perceptron) classifier. Experimental results show that the proposed scheme outperforms previous methods in terms of detection rates and accuracy.

Moisture Absorption of Granular Fertilizer and Its Distribution Characteristic in a Pneumatic Applicator (입제비료의 흡습과 송풍식 살포기에서의 비산특성)

  • Hong, J.H.;Kim, Y.J.;Rhee, J.Y.;Chung, J.H.;Kim, J.Y.;Kim, J.H.;Kim, T.W.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.5 s.118
    • /
    • pp.389-394
    • /
    • 2006
  • The characteristic of moisture absorption of granular fertilizer was measured at several different opening sizes on the top cover of a hopper in a humid weather. The size of the opening was to represent the degree of looseness of sealing of the top cover of the hopper. The application distribution was characterized by the scattering distance of granular fertilizer with different degree of moisture absorption in a pneumatic granular fertilizer applicator. The moisture absorption rates were 12.92 and 12.26 mg of moisture an hour for one gram of each granular fertilizers of NPK 22-12-12 and 21-17-17, respectively. The moisture absorption increased linearly as the opening size increased. The median value of the scattering distance distribution decreased with time of absorption, however, it decreased very slowly after three hours of absorption.

Non Destructive Technique for Steel Corrosion Detection Using Heat Induction and IR Thermography (열유도 장치와 적외선 열화상을 이용한 철근부식탐지 비파괴 평가기법)

  • Kwon, Seung Jun;Park, Sang Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.2
    • /
    • pp.40-48
    • /
    • 2012
  • Steel corrosion in concrete is a main cause of deterioration and early failure of concrete structures. A novel integration of electromagnetic heat induction and infrared (IR) thermography is proposed for nondestructive detection of steel corrosion in concrete, by taking advantage of the difference in thermal characteristics of corroded and non-corroded steel. This paper focuses on experimental investigation of the concept. An inductive heater is developed to remotely heat the embedded steel from concrete surface, which is integrated with an IR camera. Concrete samples with different cover depths are prepared. Each sample is embedded with a single rebar in the middle, resulting an identical cover depth from the front and the back surfaces, which enable heat induction from one surface and IR imaging from the other simultaneously. The impressed current (IC) method is adopted to induce accelerated corrosion on the rebar. IR video images are recorded during the entire heating and cooling periods. The test results demonstrate a clear difference in thermal characteristics between corroded and non-corroded samples. The corroded sample shows higher rates of heating and cooling than those of the non-corroded sample. This study demonstrates a potential for nondestructive detection of rebar corrosion in concrete.

Analysis of Hairpiece-related Patent Trends (가발 관련기술에 대한 특허동향 연구)

  • Park, Jang-Soon;Kim, Young-Joo;Lim, Sun-Nye
    • Journal of Digital Convergence
    • /
    • v.16 no.12
    • /
    • pp.611-617
    • /
    • 2018
  • This study divided hairpiece-related technologies into three categories: Materials, Structure, Hair Extensions. Then, it investigated the current patent application trends in the above technologies and attempted to determine what aspects should be focused on in terms of the growth potential of hairpiece-related technologies and future technologies. A hairpiece is used to cover a specific balding area resulting from innate factors such as heredity or acquired traits including disease or accident. It is also used to make short hair look longer. Recently, as the rates of hair loss caused by stress increase, there has been a rising demand for hairpieces that can quickly and conveniently cover a balding region as well as satisfy people's aesthetic needs through diverse hairstyling. Even though patents have been applied evenly across hairpiece technology fields, patent activity has declined since 2010 was confirmed. Therefore, this study targets the facilitation and expansion of the hairpiece technology market by suggesting desirable R&D directions for future hairpiece-related technologies after analyzing current hairpiece patent trends.

Behavioral changes of sows with changes in flattening rate

  • Ka-Young, Yang;Dong-hwa, Jang;Kyeong-seok, Kwon;Taehwan, Ha;Jong-bok, Kim;Jae Jung, Ha;Jun-Yeob, Lee;Jung Kon, Kim
    • Journal of Animal Science and Technology
    • /
    • v.64 no.3
    • /
    • pp.564-573
    • /
    • 2022
  • In this study, considering the difficulties for all farms to convert farm styles to animal welfare-based housing, an experiment was performed to observe the changes in the behavior and welfare of sows when the slat floor was changed to a collective breeding ground. Twenty-eight sows used in this study were between the second and fifth parities to minimize the influence of parity. Using a flats floor cover, the flattening rates were treated as 0%, 20%, 30%, 40%, and 50%. Data collection was the behavior of sows visually observed using a camera (e.g., standing, lying, fighting and excessive biting behaviors, and abnormal behaviors) and the animal welfare level measured through field visits. Lying behavior was found to be higher (p < 0.01) as the flattening rate increased, and sows lying on the slatted cover also increased as the flattening rate increased (p < 0.01). Fighting behavior wasincreased when the flattening rate was increased to 20%, and chewing behavior was increased (p < 0.05) as the flattening rate increased. The animal welfare level of sows, 'good feeding', it was found that all treatment groups for body condition score and water were good at 100 (p < 0.05). 'Good housing' was the maximum value (100) in each treatment group. As the percentage of floor increased, the minimum good housing was increased from 78 in 0% flattening rate to 96 in 50% flattening rate. The maximum (100) 'good health' was achieved in the 0% and 20% flattening rates, and it was 98, 98, and 99 in the 30%, 50%, and 40% flattening rate, respectively. 'Appropriate behavior' score was significantly lower than that of other paremeters, but when the flattening ratio was 0% and 20%, the maximum and minimum values were 10. At 40% and 50%, the maximum values were 39 and 49, respectively, and the minimum values were analyzed as 19 for both 40% and 50%. These results will be used as basic data about sow welfare for farmers to successfully transition to group housing and flat floors.

An Experimental Study for Drainage Capacity Improvement of Waterway with Steep Slope (급경사 사면 도수로의 배수능력 개선을 위한 실험적 연구)

  • Kim, Jung Soo;Kim, Ju Hyung;Yoon, Sei Eui
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.6
    • /
    • pp.2303-2315
    • /
    • 2013
  • In general, the waterway was installed for drain water from steep slope and waterway cover was set up to prevent overflow and water separation at berm of waterway. In this study, hydraulic experiment was conducted to analyze the flow characteristics and enact standard design criteria of the waterway. Hydraulic experimental apparatus which can change the slope of waterway and the length of berm were installed to analyze of flow characteristics at the waterway. The slopes of waterway were $40^{\circ}$, $50^{\circ}$, $60^{\circ}$, and $70^{\circ}$ and the range of discharge were 1.0~5.6 ${\ell}/s$. The flow in berm was distinguished two types such as hydraulic jump and splash flow. These kinds of flows depended on the rates of discharge in waterway. When inlet discharge was below 1.1~2.0 ${\ell}/s$, the separation phenomenon of water was generated at upper and lower portion in berm by the splash flow. The scattering range of water particles and length of water separation was measured depending on the slope of waterway. The start point of scattering was about 20 cm(1.3B) from the place connected upper waterway with brem and the length of water separation was till 210 cm(3.5B) from the place connected lower waterway with brem. Therefore, the waterway cover needed to install from starting of berm to 1B and from the lower part of berm to 3.5B.

A Historical Survey on the Background of Establishment of British P & I Club (영국계 P&I 클럽의 설립배경에 관한 사적 고찰)

  • Shin, Gun-Hoon
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.34
    • /
    • pp.77-108
    • /
    • 2007
  • The traditional name given to the insurance of third party liabilities and certain contractual liabilities which arise in connection with the operation of ships is protection and indemnity(P & I) insurance. P & I insurance is very different from traditional hull and machinery insurance in that shipowners' hull and machinery insurance is designed primarily to protect the assured against losses to his vessel, whereas P & I insurance seeks to indemnify an shipowner in respect of the discharge of legal liabilities he has incurred in operating his own vessels. This study is to examine the background of establishment of British P & I clubs md, therefore, the identity of P & I insurance. The present British P & I clubs are the remote descendants of the many small and local hull mutual insurance clubs that were formed by British shipowners in the end of 18th century. At that time, British shipowners were dissatified with the state of marine insurance market and, therefore, established clubs together in mutual hull insurance clubs. After the removal of the company monopoly in 1824, greater competition had a good effect on the rates, terms of cover and service offered by the commercial marine insurance market and by Lloyd's underwriters, and the hull clubs became less necessary and went into decline. The burden of British shipowners on liabilities to third parties was steadily increased after the middle of the 19th century, but the amount insured under hull policy was limited in the insured value of the ship. Eventually, the first protection club, that is, the Shipowners' Mutual Protection Society was formed in 1855. It was designed to like past mutual hull clubs, but to cover liabilities for loss of life and personal injury and also the collision risks excluded from the current marine policies, particularly the excess above the limits in hull policies. In 1870, the risks of liability for loss of or damage to cargo carried on board the insured ship was first awarded by the British shipowners. After 1874, many protection clubs formed indemnity club to cover the risk of liability for loss or damage to cargo. As mentioned above, British P & I clubs have been steadily changed according to the response of shipowners under the rapidly changing law of British shipowners' liability, and so on in the future.

  • PDF

Evaluation of Separation Distance from the Temporary Storage Facility for Decontamination Waste to Ensure Public Radiological Safety after Fukushima Nuclear Power Plant Accident (후쿠시마 원전 사고 이후 일반인의 방사선학적 안전성 확보를 위한 제염폐기물 임시저장시설 이격거리 평가)

  • Kim, Min Jun;Go, A Ra;Kim, Kwang Pyo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.3
    • /
    • pp.201-209
    • /
    • 2016
  • The object of this study was to evaluate the separation distance from a temporary storage facility satisfying the dose criteria. The calculation of ambient dose rates took into account cover soil thickness, facility size, and facility type by using MCNPX code. Shielding effects of cover soil were 68.9%, 96.9% and 99.7% at 10 cm, 30 cm and 50 cm respectively. The on-ground type of storage facility had the highest ambient dose rate, followed by the semi-ground type and the underground type. The ambient dose rate did not vary with facility size (except $5{\times}5{\times}2m\;size$) due to the self-shielding of decontamination waste in temporary storage. The separation distances without cover soil for a $50{\times}50{\times}2m\;size$ facility were evaluated as 14 m (minimum radioactivity concentration), 33 m (most probably radioactivity concentration), and 57 m (maximum radioactivity concentration) for on-ground storage type, 9 m, 24 m, and 45 m for semi-underground storage type, and 6 m, 16 m, and 31 m for underground storage type.

Growth and Ground Coverage of Ophiopogon japonicus 'Nanus' under Different Shade Conditions (차광처리에 따른 애기소엽맥문동의 생장과 피복에 관한 연구)

  • Kang, Ae-Ran;Park, Seok-Gon
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.45 no.2
    • /
    • pp.68-75
    • /
    • 2017
  • Demand for dwarf mondo grass (DMG; Ophiopogon japonicus 'Nanus') as an ornamental garden plant is expected to grow in the future. The purpose of this study was to investigate the levels of shade tolerance and ground cover by growing DMG under a variety of shade conditions for 18 months (May 2015~October 2016). DMG plants grown in bare ground for 3 years in Jangheung-gun, Jeonnam were used for testing. In an experimental site created in Naju city in Jeonnam, the DMG was planted in planters ($70cm{\times}70cm{\times}24cm$) and covered with a shading curtain to block natural light. Shaded conditions were then arranged under different levels of shade (0%, 55% and 75%). When the plants were grown, growth (leaf size, the number of leaves, fresh weight and dry weight) and ground coverage of DMG were analyzed. According to the results, DMG growth in terms of leaf size and the number of leaves was statistically higher under zero shade (full sunlight), when compared to other shaded conditions. DMG's fresh and dry weights were significantly greater under 0% and 55% shade, compared to those under 75% shade. The degrees of shade tolerance required for normal growth of DMG were found in the range of 0~50%, meaning that more than 50% shade may decrease plant growth. There were no statistical differences in ground coverage rates of DMG under different levels of shade. When 220 tillers were planted per $1m^2$ of plot, up to 80% of the area was covered by DMG after 18 months. Since DMG requires nutrient-rich soil to grow, sufficient nitrogen fertilizers are proposed to accelerate the ground cover of DMG. As DMG remained alive over the winter in the experiments, this study also suggests that DMG can be planted in the southern temperate region.

Estimating the Completeness of Gastric Cancer Registration in Ardabil/Iran by a Capture-Recapture Method using Population-Based Cancer Registry Data

  • Khodadost, Mahmoud;Yavari, Parvin;Babaei, Masoud;Mosavi-Jarrahi, Alireza;Sarvi, Fatemeh;Mansori, Kamyar;Khodadost, Behnam
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.5
    • /
    • pp.1981-1986
    • /
    • 2015
  • Background: Knowledge of cancer incidences is essential for cancer prevention and control programs. Capture-recapture methods have been recommended for reducing bias and increasing the accuracy of cancer incidence estimations. This study aimed to estimate the completeness of gastric cancer registration by the capture-recapture method based on Ardabil population-based cancer registry data. Materials and Methods: All new cases of gastric cancer reported by three sources, pathology reports, death certificates and medical records that reported to Ardabil population-based cancer registry in 2006 and 2008 were enrolled in the study. The duplicate cases based on the similarity of first name, surname and fathers names were identified between sources. The estimated number of gastric cancers was calculated by the log-linear method using Stata 12 software. Results: A total of 857 new cases of gastric cancer were reported from three sources. After removing duplicates, the reported incidence rates for the years 2006 and 2008 were 35.3 and 32.5 per 100,000 population, respectively. The estimated completeness calculated by log-linear method for these years was 36.7 and 36.0, respectively. Conclusions: These results indicate that none of the sources of pathology reports, death certificates and medical records individually or collectively fully cover the incident cases of gastric cancer. We can obtain more accurate estimates of incidence rates using the capture-recapture method.