• Title/Summary/Keyword: Coupling coil

Search Result 140, Processing Time 0.028 seconds

Analysis of Inductive Power Transfer System According to Layer Structure of Transceiver Coil (자기유도방식 무선전력전송 시스템 송수신 코일 Layer 구조에 따른 특성 분석)

  • Kim, Cheol-Min;Yoo, Jae-Gon;Kim, Jong-Soo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.2
    • /
    • pp.78-83
    • /
    • 2019
  • In this study, we analyze the structure of the transceiver coil in the inductive power transfer (IPT) system. In the IPT system, the transceiver coil design needs to have the highest magnetic coupling possible because of the relatively low magnetic coupling due to the large gap of distance without the core. The transmitting coil may be formed as a multi-layer type according to the distance between the transmitting and receiving coils if the receiving coil is configured as a multi-layer type on the inner structure of the receiving apparatus, thereby improving the magnetic coupling and system efficiency. We compare and analyze the coil magnetic coupling, and system efficiency according to the layer structure of the transmitting and receiving coils and verify the analysis by JMAG simulation. Experimental results show that the layer structure of the transceiver should be considered according to the inner space of the receiving device and the spacing distance.

RF Shimming Considering Coupling Effects for High-Field MRI

  • Heo, Hye-Young;Cho, Min-Hyoung;Lee, Soo-Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.4
    • /
    • pp.267-271
    • /
    • 2008
  • The RF shimming technique has been used to improve the transmit RF field homogeneity in highfield MRI. In the RF shimming technique, the amplitude and phase of the driving currents in each coil element are optimized to get homogenous flip angle or uniform image intensity. The inductive and capacitive coupling between the coil elements may degrade the RF field homogeneity if not taken into account in the optimization procedure. In this paper, we have analyzed the coupling effects on the RF shimming using a sixteen-element TEM RF coil model operating at 300 MHz. We have found that the coupling effects on the RF shimming can be reduced by putting high dielectric material between the active rung and the shield.

Development of Signal Coupler for Power Line Communication over Medium Voltage Distribution Line (고압 배전선로 전력선 통신 신호결합장치 개발)

  • Lee Jae-Jo;Park Young-Jin;Oh Hui-Myoung;Kim Kwan-Ho;Lee Dae-Young
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.6
    • /
    • pp.409-416
    • /
    • 2005
  • For broadband high-data-rate power line communication with the allocated frequency bandwidth from 2 to 30 MHz on medium voltage (MV) distribution power lines, a signal coupling unit is developed. The coupling unit is composed of a coupling capacitor for coupling communication signal, a drain coil, and an impedance matching part. The coupling capacitor made of ceramic capacitor is designed for transmission property of better than 1 dB in the frequency range. The drain coil is used for preventing low frequency high voltage from junction of medium voltage power line in case that a coupling capacitor is not working properly any more. Also, using ferrite core, a novel broadband impedance matching transformer is developed. A complete coupling unit with a coupling capacitor, a drain coil, and a matching transformer is housed by polymer for good isolation and distinguishing from high voltage electric facilities. Each is fabricated and its frequency behavior is tested. Finally, complete signal couplers are equipped in a MV PLC test bed and their performance are measured. The measurement shows that the coupling capacitor works excellently.

Analysis of a Linkage Coil for Wireless Power Transmission by Inductive Coupling

  • Gimm, Youn-Myoung;Yoo, Ho-Sang;Kim, Myoung-Wha;Yoo, Jae-Sung
    • Journal of electromagnetic engineering and science
    • /
    • v.8 no.1
    • /
    • pp.23-27
    • /
    • 2008
  • Magnetic coupling delivering wireless power in capsular endoscope(CE) is described in this paper. The characteristic of the magnetic flux linkage coil which generates the induced electromotive force(emf) under the magnetic field was analyzed. With the analyzed results, a magnetic flux linkage coil system was developed and tested. It was confirmed that the magnetic flux linkage coil system could supply more than 50 mW power at 125 kHz without changing the structure of conventional CE.

A Quadrature RF Coil for 0.3 Tesla MRI Systems (0.3 Tesla MRI용 Quadrature 고주파코일)

  • Lee, J.H.;Lee, S.Y.;Khang, D.H.;Mun, C.W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.301-302
    • /
    • 1998
  • A quadrature RF coil has been developed for 0.3 Tesla permanent MRI systems. The quadrature RF coil is composed of a solenoid coil and a saddle shaped coil. To minimize the coupling ratio between the two coils, each coil is serially connected to a small extra loop. and the small loops are magnetically coupled to each other. By deliberately adjusting relative positions of the small loops, we have decreased the coupling ratio up to -30dB.

  • PDF

Current Limiting Characteristics of Separated Three-phase Flux-coupling Type SFCL according to Winding Number of Coil 2 and Winding Direction (삼상 분리형 자속커플링 전류제한기의 2차 권선의 턴 수 및 결선 방향에 따른 전류제한 특성)

  • Kim, Yong-Jin;Du, Ho-Ik;Doo, Seung-Gyu;Kim, Min-Ju;Lee, Dong-Hyeok;Han, Byoung-Sung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.8
    • /
    • pp.694-697
    • /
    • 2009
  • The separated three-phase flux-coupling type superconducting fault current limiter(SFCL) is composed of a series transformer and superconducting unit of the YBCO coated conductor. The primary and secondary coils in the transformer were wound in series each other through an iron core and the YBCO coated conductor was connected with secondary coil in parallel. In this paper, we investigated the current limiting characteristics through winding number of coil 2 and winding direction in the flux-coupling type SFCL. Through the analysis, it was shown that additive polarity condition and lower winding number of coil 2 have advantaged from the point of view of fault current limiting and burned of YBCO coated conductor.

Magnetic Field Analysis of Wireless Power Transfer via Magnetic Resonant Coupling or Electric Vehicle

  • Kesamaru, Katsumi
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.1
    • /
    • pp.83-87
    • /
    • 2014
  • This paper describes the magnetic field analysis of wireless power transfer via magnetic resonant coupling. The wireless power transfer system for supplying power to electric vehicle is developed. The parameters of coil transfer system are simulated by the finite element method (FEM). Therefore the coil structure of power transfer system can be accurately analyzed. This paper deals with 3kW wireless transfer system.

Implementation of Wireless Power Transfer Circuit by Using Magnetic Resonant Coupling Method

  • Lho, Young-Hwan
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.306-309
    • /
    • 2019
  • Wireless charging is a technology of transmitting power through an air gap to an electrical load for the purpose of energy dissemination. Compared to traditional charging with code, wireless power charging has many benefits of avoiding the hassle from connecting cables, rendering the design and fabrication of much smaller devices without the attachment of batteries, providing flexibility for devices, and enhancing energy efficiency, etc. A transmitting coil and a receiving coil for inductive coupling or magnetic resonant coupling methods are available for the near field techniques, but are not for the far field one. In this paper, the wireless power transfer (WPT) circuit by using magnetic resonant coupling method with a resonant frequency of 13.45 Mhz for the low power system is implemented to measure the power transmission efficiency in terms of mutual distance and omnidirectional angles of receiver.

A Proposal of Measuring Method for Coupling Coefficient between Coils (코일간의 결합계수 측정법의 시안)

  • 김주홍;이용구;최우승;이원일
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.8 no.2
    • /
    • pp.63-68
    • /
    • 1994
  • With the expression inducted from equivalent circuit of transformer using coupling coefficient K, measuring terminal voltage, a calculation of coil coefficient with reapect to turn ratio is proposed. By that methcxi of measuring K, compared with values theorically, this paper confirmed its propriety. With that methcxi of measuring coil coefficient K, having several couple of coil set, we have clarified the characteristic of K according to changing coil's position, programming regression of least square methcxi, and then the expression for function of K is formulated.

  • PDF

A Study on the Effect of Resonant Coil Size and Load Resistance on the Transmission Efficiency of Magnetic Resonance Wireless Power Transfer System (공진 코일의 크기와 부하 저항이 자계 공명 무선 전력 전송 장치의 전달 효율에 주는 영향에 관한 연구)

  • Park, Jeong-Heum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.7
    • /
    • pp.45-51
    • /
    • 2012
  • In this paper, the wireless power transfer system using the magnetic resonance was designed and the effect of resonant coil radius and load resistance to this system was analyzed by the circuit analysis method. As a result, the calculated transmitted-power is similar to measured one, and the coil size has a small effect to the coupling coefficients in the resonant frequency band. In addition, the fact that the calculated transmitted-power according to the source frequency is similar to measured one confirms that the circuit analysis methode in this paper is valid. The input side transmission efficiency ${\eta}_i$ including only the loss in the power transfer circuit is almost 90[%] with the large coil in the 10[cm] transfer distance, and 65[%] with the small coil in 1[cm]. The source side transmission efficiency ${\eta}_s$ is 30~40[%] at both coil when load resistance below 4.7[${\Omega}$] has been connected. Considering that the maximum ${\eta}_s$ is 50[%], this is valid in the practical applications.