• Title/Summary/Keyword: Coupled magnetic resonance

Search Result 69, Processing Time 0.029 seconds

Hard Tissue Analysis of NMR after Fluoride Administration

  • Kim, Hye-Young;Nam, Seoul-Hee;Han, Man-Seok
    • Journal of Magnetics
    • /
    • v.21 no.4
    • /
    • pp.599-602
    • /
    • 2016
  • Fluoride (F) is an important element for the mineralization of body tissues. The purpose of this study was to administer fluoride prenatally to rats to evaluate its beneficial concentration for rat bone using microstructural analysis, to analyze its effect on the bone structure, and to evaluate the effect of its transfer through rat placenta. Fourier transform infrared spectroscopy (FTIR) and nuclear magnetic resonance spectrometry (NMR) were performed. The $^{19}F$ NMR and $^{31}P$ NMR signals suggested the existence of fluoride ions in the apatite lattice because the signals were caused by the fluoride ions that were coupled to the phosphate atoms and were affected in the phosphate phases other than the element phases in the apatite. Consequently, if it was not affected too much, the desirable concentration of prenatal fluoride treatment could have a helpful effect on the bone crystal structure through placental fluoride transfer.

Angular Dependence of Ferromagnetic Resonance Linewidth in Exchange Coupled CoFe/MnIr Bilayers (교환 결합력을 갖는 CoFe/MnIr 박막에서 강자성 공명 선폭의 각도 의존성 연구)

  • Yoon, Seok Soo;Kim, Dong Young
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.2
    • /
    • pp.50-54
    • /
    • 2016
  • We analyzed the angular dependence of ferromagnetic resonance linewidth in exchange coupled CoFe/MnIr bilayers. The maximum and minimum linewidth was observed in the easy and hard direction of unidirectional anisotropy by exchange coupling, respectively, and it was well agreed with the angular dependence of exchange bias field. The maximum linewidth was due to the twist of CoFe magnetization near CoFe/MnIr interface from direction of pinned MnIr spin to direction of applied magnetic field. While, minimum linewidth more higher than that of CoFe was related to rotatable anisotropy field, and explained by easy axis distribution of MnIr grains.

Ferromagnetic Resonance of Magnetic Tunnel Junctions with an Exchange Biased Synthetic Ferrimagnetic Reference Layer (교환 바이어스 인위적 준강자성 기준층을 포함한 자기 터널 접합의 강자성 공명)

  • Yoon, Jung-Bum;You, Chun-Yeol;Jung, Myung-Hwa
    • Journal of the Korean Magnetics Society
    • /
    • v.21 no.4
    • /
    • pp.121-126
    • /
    • 2011
  • Spin dynamics of magnetic tunnel junctions with free and fixed reference layers is investigated by ferromagnetic resonance micromagnetic simulations. First, in magnetic tunnel junctions with an exchange biased synthetic ferrimagnetic reference layer, a magnetization direction of each layer and the tunneling magnetoresistance are calculated for a DC magnetic field. To investigate the spin exciting modes in magnetic tunnel junctions, we simulate the ferromagnetic resonance frequency spectra with small RF magnetic fields. Exciting modes of the tunneling magnetoresistance calculated by an included angle between free and reference layers is interpreted from those of each layer. Spin exciting modes are different according to a signs of the DC magnetic field. In a negative magnetic field, FMR frequency spectra of free and reference layers are well elucidated by the modified Kittel's equation. However, in a positive magnetic field, there is no simple analytic solution related to FMR frequency spectra due to the coupled modes. Since ferromagnetic layers in magnetic tunnel junctions are interactive each other, careful considerations of the reference and fixed layer as well as the free layer are required for understanding on the spin dynamics of magnetic tunnel junctions with an exchange biased synthetic ferrimagnetic reference layer.

Spectroscopic characterization of N,N'-bis(salicylidene)pentane-1,3-diamine nickel(II) complex

  • Kim, Gilhoon;Won, Hoshik
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.18 no.2
    • /
    • pp.74-81
    • /
    • 2014
  • The $N_2O_2$ tetradentate Schiff base ligand, N,N'-bis(salicylidene)pentane-1,3-diamine (Salpn), coupled with 1:2 concentration ratio of 1,3-diaminopentane and salicylaldehyde was used to produce a series of macrocyclic Nikel(II) complexes. In the metal complexation, it was observed that Salpn macrocyclic ligand can adopt more than a metal ion giving an unique multinuclear metal complexes including Ni(II)Salpn and $Ni(II)_3(Salpn)_2$. Characteristic IR ${\upsilon}(M-O)$ peaks for Ni(II)Salpn and $Ni(II)_3(Salpn)_2$ were observed to be $1028cm^{-1}$ and $1024cm^{-1}$, respectively. Characteristic UV-Vis absorption ${\lambda}_{max}$ peaks for $Ni(II)_3(Salpn)_2$ were observed to be 241nm and 401 nm. Structural characterization of $Ni(II)_3(Salpn)_2$ by NMR exhibits that the salicylidene ring moiety has two different resonance signals originated from the magnetically asymmetric diligand and trinuclear bis complex. Complete NMR signal assignments and characterizations elucidating structural features of $Ni(II)_3(Salpn)_2$ were described in detail.

Wireless Energy Transfer System with Multiple Coils via Coupled Magnetic Resonances

  • Cheon, Sanghoon;Kim, Yong-Hae;Kang, Seung-Youl;Lee, Myung Lae;Zyung, Taehyoung
    • ETRI Journal
    • /
    • v.34 no.4
    • /
    • pp.527-535
    • /
    • 2012
  • A general equivalent circuit model is developed for a wireless energy transfer system composed of multiple coils via coupled magnetic resonances. To verify the developed model, four types of wireless energy transfer systems are fabricated, measured, and compared with simulation results. To model a system composed of n-coils, node equations are built in the form of an n-by-n matrix, and the equivalent circuit model is established using an electric design automation tool. Using the model, we can simulate systems with multiple coils, power sources, and loads. Moreover, coupling constants are extracted as a function of the distance between two coils, and we can predict the characteristics of a system having coils at an arbitrary location. We fabricate four types of systems with relay coils, two operating frequencies, two power sources, and the function of characteristic impedance conversion. We measure the characteristics of all systems and compare them with the simulation results. The flexibility of the developed model enables us to design and optimize a complicated system consisting of many coils.

dispersion characteristics and RE power absorption for a mangetized plasma (자화 플라즈마의 분산특성과 유효광학계수 변화)

  • 라상호;정재성;오범환;박세근
    • Journal of the Korean Vacuum Society
    • /
    • v.9 no.3
    • /
    • pp.285-289
    • /
    • 2000
  • It has been well known that weak axial magnetic field on the process plasma enhances plasma density. As the magnetic field helps a specific polarized EM wave mode to penetrate into the plasma, the energy transfer to the plasma enhances and the ion density increases. We have analyzed systematic change of the dispersion relation caused by the cyclotron resonance condition. This resonance occurs at near 5 gauss to provide minimum penetration depth, as known before. RF penetration depth increases abruptly beyond the magnetic field of 5 gauss, and this phenomena lessen as the collision frequency increases.

  • PDF

A Study on the High Selective Oxide Etching using Inductively Coupled Plasma Source (유도결합형 플라즈마원을 이용한 고선택비 산화막 식각에 관한 연구)

  • 이수부;박헌건;이석현
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.4
    • /
    • pp.261-266
    • /
    • 1998
  • In developing the high density memory device, the etching of fine pattern is becoming increasingly important. Therefore, definition of ultra fine line and space pattern and minimization of damage and contamination are essential process. Also, the high density plasma in low operating pressure is necessary. The candidates of high density plasma sources are electron cyclotron resonance plasma, helicon wave plasma, helical resonator, and inductively coupled plasma. In this study, planar type magnetized inductively coupled plasma etcher has been built. The density and temperature of Ar plasma are measured as a function of rf power, flow rate, external magnetic field, and pressure. The oxide etch rate and selectivity to polysilicon are measured as the above mentioned conditions and self-bias voltage.

  • PDF

Stator Displacement Analysis of Switched Reluctance Motor Due to Electromagnetic Force According to Switching (스위칭에 따른 전자기 가진력에 의한 스위치드 릴럭턴스 전동기의 고정자 변위해석)

  • Ha, Gyeong-Ho;Hong, Jeong-Pyo;Kim, Gyu-Tak
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.1
    • /
    • pp.20-26
    • /
    • 2000
  • This paper deals with the modal analysis and the displacement of stator due to electromagnetic forces in Switched Reluctance Motor(SRM). A free-free model of the stator based on structural 3-dimensional Finite Element Method(FEM) is used for investigation the natural frequencies and the mode shapes of the stator. In addition, The displacement caused by magnetic force acting on stator pole is analyzed by the structural FEM coupled with the magnetic force. From these results, the resonance speed is obtained by the relation of the natural frequencies of the harmonic frequencies of magnetic force. And, the eccentricity with respect to rotor is predicted from the analysis result of the mechanical displacement of stator. The natural frequencies of stator are compared with experimental ones measured by modal testing.

  • PDF

Time-Domain Analysis of Wireless Power Transfer System Behavior Based on Coupled-Mode Theory

  • Shim, Hyunjin;Nam, Sangwook;Lee, Bomson
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.4
    • /
    • pp.219-224
    • /
    • 2016
  • In this paper, coupled-mode theory (CMT) is used to obtain a transient solution analytically for a wireless power transfer system (WPTS) when unit energy is applied to one of two resonators. The solutions are compared with those obtained using equivalent circuit-based analysis. The time-domain CMT is accurate only when resonant coils are weakly coupled and have large quality factors, and the reason for this inaccuracy is outlined. Even though the time-domain CMT solution does not describe the WPTS behavior precisely, it is accurate enough to allow for an understanding of the mechanism of energy exchange between two resonators qualitatively. Based on the time-domain CMT solution, the critical coupling coefficient is derived and a criterion is suggested for distinguishing inductive coupling and magnetic resonance coupling of the WPTS.

Identification of Xanthium Sibiricum Components using LC-SPE-NMR-MS Hyphenated System

  • Sohn, Ji Soo;Jung, Youngae;Han, Ji Soo;Hwang, Geum-Sook
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.22 no.2
    • /
    • pp.26-33
    • /
    • 2018
  • Xanthium sibiricum is used as a traditional folk medicine for the treatment of cancer, fever, headache, nasal sinusitis, and skin pruritus. This study aimed to identify components from Xanthium sibiricum extracts using an SPE-800MHz NMR-MS hyphenated system. The simultaneous acquisition of MS and NMR spectra from the same chromatographic peaks significantly increases the depth of information acquired for the compound and allows the elucidation of structures that would not be possible using MS or NMR data alone. LC -NMR analysis was conducted using a HPLC separation system coupled to 800 MHz spectrometer equipped with a cryoprobe, and a SPE unit was used to automatically trap chromatographic peaks using a HPLC pump. LC-MS analysis was conducted with a Q-TOF MS instrument using ESI ionization in the negative ion mode. Using the hyphenated analysis, several secondary metabolites were identified, such as 3',5'-O-dicaffeoylquinic acid, 1',5'-O-dicaffeoyl- quinic acid, and ethyl caffeate. These results demonstrate that the SPE-800MHz NMR-MS hyphenated system can be used to identify metabolites within natural products that have complex mixtures.