• Title/Summary/Keyword: Counts data

Search Result 634, Processing Time 0.025 seconds

Changes in the Microbial Qualites and Sensory Characteristics of Boiled Potatoes and Imitation Crab Sticks in Soy Sauce as Prepared by the Cook-Chill System and Sous Vide Cook-Chill System (Cook-chill System과 Sous vide Cook-chill System으로 생산된 감자게맛살 조림의 저장기간에 따른 미생물학적 품질과 관능특성의 변화(1))

  • Kim, Heh-Young;Song, Sun-Mi
    • Korean journal of food and cookery science
    • /
    • v.23 no.2 s.98
    • /
    • pp.252-260
    • /
    • 2007
  • This study was performed to provide basic data for the operation of the sous vide cook-chill system(SVCC) by comparing and evaluating the quality of SVCC prepared foods to those prepared using the cook-chill system(CC). Foremost, the microbial risk was less and the food quality excellent when SVCC was used compared to CC, where changes in pH, Aw and moisture loss were less with SVCC. The CC and SVCC Aw value were 0.93 and 0.92 and 0.92 and 0.95 at 0 days and 15 days, respectively. Secondly, the microbial quality by storage days was relatively high with SVCC. The CC and SVCC viable cell and coliform counts were 4.43 and 4.37 LogCFU/g, and 4.53 and 3.60 LogCFU/g, respectively, by 15 days. Also, after reheating, the viable cell and coliform counts satisfide the standards applied in processed food(5.0 and 2.0 LogCFU/g respectively). Lastly, the sensory scores for SVCC were higher than those for CC. Thus, microbial and sensory qualities by days of storage were acceptable and overall quality satisfaction was better for SVCC than CC.

The Nutritional Composition of Bamboo Shoots and the Effects of its Fiber on Intestinal Microorganisms (죽순의 영양성분 및 죽순의 식이섬유가 장내미생물에 미치는 영향)

  • Park, Eun-Jin;Jhon, Deok-Young
    • Journal of the Korean Society of Food Culture
    • /
    • v.28 no.5
    • /
    • pp.502-511
    • /
    • 2013
  • This study evaluated the composition two popular species of edible bamboo shoots in Korea (Phyllostachyspubescens and Sinoarundinarianigra) and the effect of their abundant dietary fiber on intestinal microorganisms in healthy young women. The ranges of total moisture, crude protein, crude lipid, crude ash, and dietary fiber content were 87.190.8, 2.943.5, 0.150.39, 0.411.05, and 4.206.15% (wet weight basis), respectively. Moisture and crude ash content increased after heat treatment; however, crude protein, crude lipid, and dietary fiber content were reduced after heating. The major minerals found in bamboo shoots were potassium, phosphorous, sulfur, magnesium, and calcium. In addition, glucose and fructose were abundant free sugars, while asparagine and tyrosine were the most abundant free amino acids. Approximately 70% of the total free fatty acids found in bamboo shoots were linoleic acid and linolenic acid. The ascorbic acid content was 6.60~17.56 mg/100 g (wet weight basis), and one phenolic compound, p-hydroxy benzoic acid, was 0.10.2% (wet weight basis) and detected by HPLC analysis. The intake of bamboo shoots for seven days significantly increased viable cell counts of Lactobacillus spp. and reduced viable cell counts of Bacteriodes spp. in feces (p<0.05). In our data, bamboo shoots may be useful in the food industry as high dietary fiber ingredients.

A Genome-wide Association Study of Copy Number Variation in Hematological Parameters in the Korean Population

  • Kim, Ka-Kyung;Cho, Yoon-Shin;Cho, Nam-H.;Shin, Chol;Kim, Jong-Won
    • Genomics & Informatics
    • /
    • v.8 no.3
    • /
    • pp.122-130
    • /
    • 2010
  • Abnormal hematological values are associated with various disorders including cancer and cardiovascular, metabolic, infectious, and immune diseases. We report the copy number variations (CNVs) in clinically relevant hematological parameters, including hemoglobin level, red and white blood cell counts, platelet counts, and red blood cell (RBC) volume. We describe CNVs in several loci associated with these hematological parameters in 8,842 samples from Korean population-based studies. The data that we evaluated included four RBC parameters, one platelet parameter, and one associated with total white blood cell (WBC) count, exceeding the genome-wide significance. We show that CNVs in hematological parameters are associated with some loci, different from previously associated loci reported in single nucleotide polymorphism (SNP) association studies.

Partial Discharge Characteristics due to shift of Void Position in XLPE (XLPE에서 보이드 위치변화에 따른 부분방전특성)

  • Kim, Tag-Yong;Yang, Jae-Hoon;Kim, Weon-Jong;Shin, Hyun-Taek;Kim, Wang-Kon;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.86-89
    • /
    • 2004
  • To estimate a electrical performance of the extra high voltage XLPE cable the discharge properties due to shift of void position were investigated. The ${\phi}-q-n$ properties have been measured at room temperature by rising voltage ratio of 0.5[kV]. An obtained data was stored to personal computer through A/D converter. The period of applied wave form and discharge values were divided into 64 parts and discharge values generated during 10 seconds were accumulated by phases. As a result, it was confirmed that the charge, phase angle and counts of discharge changed due to void position.

  • PDF

Life Time Diagnosis and Partial Discharge Characteristics due to shift of Void Position in XLPE (XLPE 내부 보이드 위치변화에 따른 부분방전 특성 및 수명예측)

  • Kim, Tag-Yong;Cho, Kyung-Soon;Shin, Hyun-Taek;Kim, Kwi-Yeol;Lee, Kang-Sung;Lee, Chung-Ho;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.256-257
    • /
    • 2005
  • To estimate a electrical performance of the extra high voltage XLPE cable the discharge properties due to shift of void position were investigated. The $\Phi-q-n$ properties have been measured at room temperature by rising voltage ratio of 0.5[kV]. An obtained data was stored to personal computer through A/D converter. The period of applied wave form and discharge values were divided into 64 parts and discharge values generated during 10 seconds were accumulated by phases. As a result, it was confirmed that the charge, phase angle and counts of discharge changed due to void position.

  • PDF

Hierarchical time series forecasting with an application to traffic accident counts (계층적 시계열 분석을 이용한 지역별 교통사고 발생건수 예측)

  • Lee, Jooeun;Seong, Byeongchan
    • The Korean Journal of Applied Statistics
    • /
    • v.30 no.1
    • /
    • pp.181-193
    • /
    • 2017
  • The paper introduces bottom-up and optimal combination methods that can analyze and forecast hierarchical time series. These methods allow forecasts at lower levels to be summed consistently to upper levels without any ad-hoc adjustment. They can also potentially improve forecast performance in comparison to independent forecasts. We forecast regional traffic accident counts as time series data in order to identify efficiency gains from hierarchical forecasting. We observe that bottom-up or optimal combination methods are superior to independent methods in terms of forecast accuracy.

Estimation of Phosphorus Concentration in Silicon Thin Film on Glass Using ToF-SIMS

  • Hossion, M. Abul;Murukesan, Karthick;Arora, Brij M.
    • Mass Spectrometry Letters
    • /
    • v.12 no.2
    • /
    • pp.47-52
    • /
    • 2021
  • Evaluating the impurity concentrations in semiconductor thin films using time of flight secondary ion mass spectrometry (ToF-SIMS) is an effective technique. The mass interference between isotopes and matrix element in data interpretation makes the process complex. In this study, we have investigated the doping concentration of phosphorus in, phosphorus doped silicon thin film on glass using ToF-SIMS in the dynamic mode of operation. To overcome the mass interference between phosphorus and silicon isotopes, the quantitative analysis of counts to concentration conversion was done following two routes, standard relative sensitivity factor (RSF) and SIMetric software estimation. Phosphorus doped silicon thin film of 180 nm was grown on glass substrate using hot wire chemical vapor deposition technique for possible applications in optoelectronic devices. Using ToF-SIMS, the phosphorus-31 isotopes were detected in the range of 101~104 counts. The silicon isotopes matrix element was measured from p-type silicon wafer from a separate measurement to avoid mass interference. For the both procedures, the phosphorus concentration versus depth profiles were plotted which agree with a percent difference of about 3% at 100 nm depth. The concentration of phosphorus in silicon was determined in the range of 1019~1021 atoms/cm3. The technique will be useful for estimating distributions of various dopants in the silicon thin film grown on glass using ToF-SIMS overcoming the mass interference between isotopes.

A Comparative Study on Measurement of Physical Activity between Smartphone App and Self-Reported Questionnaire (스마트폰 앱과 자가보고식 설문지의 신체활동 측정 비교)

  • Suh, Minhee;Seo, Kyoungsan
    • Journal of muscle and joint health
    • /
    • v.29 no.2
    • /
    • pp.91-99
    • /
    • 2022
  • Purpose: The purpose of this study was to examine the level of agreement between smartphone apps and self-reported physical activity questionnaires. Methods: Quantitative methods were used to assess the correlation and agreement between the number of steps counted by a smartphone app and the amount of walking reported in a survey. A total of 29 adults who used smartphones were recruited from a university, and their step counts from their smartphone pedometers and responses to the international physical activity questionnaire (IPAQ) were collected over a 10-week period. Results: An analysis of 170 data pairs with Spearman's rho correlation and a Bland-Altman plot revealed a positive correlation between step counts from the smartphone app and walking activity from the IPAQ. The Bland-Altman plot also demonstrated the agreement to be improved among female participants. Conclusion: In assessing walking activity, smartphone pedometer apps showed good correlation with the IPAQ and improved agreement with the IPAQ among women. Therefore, it is suggested that the participants' gender and activity intensity, as well as the accuracy of measurement tools, should be considered in an evaluation of the delivery of physical activity promotion programs through smartphone apps.

Comparison between $180^{\circ}$ and $360^{\circ}$ Data Collection in $^{99m}Tc-MIBI$ Myocardial SPECT ($^{99m}Tc-MIBI$ 심근 SPECT에서 180도와 360도 데이터 집적의 비교)

  • Kang, Keon-Wook;Lee, Dong-Soo;Kwark, Cheol-Eun;Hyun, In-Young;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.478-483
    • /
    • 1995
  • We compared the influences of reconstruction methods using $180^{\circ}$ or $360^{\circ}$ data upon contrasts and discriminating capability and diagnostic accuracy in $^{99m}Tc-MIBI$ stress/rest myocardial SPECT. We reviewed SPECT images reconstructed only with $180^{\circ}$ projection data or with $360^{\circ}$ data in 18 patients and in 11 normal subjects. To compare counts of surface structures and deep structures, we measured ape# posterior wall ratios in 11 normal subjects. To compare the contrasts of images, we measured apex/ventricle ratios. To compare contrasts between normal and diseased myocardial segments, we measured count ratios of defect and normal segments in 4 patients who had single coronary artery diseases. To compare diagnostic accuracy, we scored SPECT images made with $180^{\circ}$ and $360^{\circ}$ data segmentally. Sensitivity and specificity for the diagnosis of coronary artery disease and for the revelation of diseased arteries with both $180^{\circ}$ and $360^{\circ}$ SPECT images. If involved coronary arteries had more narrowing than 50% In coronary angiogram, we considered them as diseased arteries Apex/posterior wall ratios were not different significantly in normal subjects. Apex/ ventricle ratios in normal subjects were different significantly between $180^{\circ}$ and $360^{\circ}$ SPECT images. Defect/normal ratios were different significantly between $180^{\circ}$ and $360^{\circ}$ SPECT images in single vessel disease patients. The overall diagnostic accurracy was the same between $180^{\circ}$ and $360^{\circ}$ data collection. Sensitivity was 94% and specificity was 91% for both types of data collection in this sample population. Sensitivity and specificity of each coronary artery territory were not significantly different between the images made with $180^{\circ}$ and $360^{\circ}$ data. The images made with $180^{\circ}$ data had better contrast between ventricle and myocardium and between hypoperfused and normal myocardium, though no difference was found between the ratios of the myocardial counts of surface and deep structures. However, diagnostic sensitivities of diseased artery territories were not different significantly and so were overall diagnostic accuracy between both methods of making images with $180^{\circ}$ and $360^{\circ}$ data.

  • PDF

Inhomogeneous Poisson Intensity Estimation via Information Projections onto Wavelet Subspaces

  • Kim, Woo-Chul;Koo, Ja-Yong
    • Journal of the Korean Statistical Society
    • /
    • v.31 no.3
    • /
    • pp.343-357
    • /
    • 2002
  • This paper proposes a method for producing smooth and positive estimates of the intensity function of an inhomogeneous Poisson process based on the shrinkage of wavelet coefficients of the observed counts. The information projection is used in conjunction with the level-dependent thresholds to yield smooth and positive estimates. This work is motivated by and demonstrated within the context of a problem involving gamma-ray burst data in astronomy. Simulation results are also presented in order to show the performance of the information projection estimators.