• Title/Summary/Keyword: Counter-flow

Search Result 492, Processing Time 0.028 seconds

Effect of Coolant Flow Characteristics in Cooling Plates on the Performance of HEV/EV Battery Cooling Systems (하이브리드/전기 자동차 배터리 냉각 시스템의 냉각수 유동 특성이 냉각 성능에 미치는 영향에 대한 해석적 연구)

  • Oh, Hyunjong;Park, Sungjin
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.3
    • /
    • pp.179-185
    • /
    • 2014
  • Average temperature and temperature uniformity in a battery cell are the important criteria of the thermal management of the battery pack for hybrid electric vehicles and electric vehicles (HEVs and EVs) because high power with large size cell is used for the battery pack. Thus, liquid cooling system is generally applied for the HEV/EV battery pack. The liquid cooling system is made of multiple cooling plates with coolant flow paths. The cooling plates are inserted between the battery cells to reject the heat from batteries to coolant. In this study, the cooling plate with U-shaped coolant flow paths is considered to evaluate the effects of coolant flow condition on the cooling performance of the system. The counter flow and parallel flow set up is compared and the effect of flow rate is evaluated using CFD tool (FLUENT). The number of counter-flows and flow rate are changed and the effect on the cooling performance including average temperature, differential temperature, and standard deviation of temperature are investigated. The results show that the parallel flow has better cooling performance compared with counter flow and it is also found that the coolant flow rate should be chosen with the consideration of trade-off between the cooling performance and pressure drop.

암모니아/물 흡수식 냉동기의 대향류 판형 재생기의 수치모델

  • 지제환;정은수;정시영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.10
    • /
    • pp.1034-1041
    • /
    • 2001
  • A numerical model which simulates the flow boiling process of the ammonia/water solution within a plate type generator for ammonia/water absorption refrigerators was developed. The ammonia/water solution flows downward under gravity and the ammonia/water vapor generated by flow boiling flows upward. The heating medium flows counter to the ammonia/water solution. The flow pattern within the generator was assumed to be a bubbly flow, and the liquid and vapor phases were assumed to be saturated. It was shown that the boiling of ammonia occurred mainly in the upper part of the generator. The effects of the heating medium inlet temperature, the mass flow rate of the heating medium and the mass flow rate of ammonia/water solution into the generator on the generation of ammonia/water vapor were investigated.

  • PDF

Design of Counter Shaft Automatic Transmission Gear Train Layout for Construction Vehicles (건설중장비용 카운터샤프트 자동변속기 기어열 레이아웃 설계)

  • Jung, G.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.6 no.3
    • /
    • pp.23-31
    • /
    • 2009
  • Counter shaft transmission is a popular automatic transmission power train in construction vehicles such as wheel loader and forklift. The gear train layout of counter shaft transmission is a very basic and important development stage because it affects the most of components design including hydraulic system and shift control algorithm, etc. This paper presents a design methodology for the gear train layout from the analysis of power flow path and clutch hook-up of the existing counter shaft transmission that is adopted in commercialized construction vehicles. Also, independent constraints for the meshed gear ratios are derived in order to realize forward 4-speed and reverse 3-speed gear ratio. The layout design principle proposed here was applied to the new original counter shaft transmission that is underdevelopment.

  • PDF

A Study on The Counter-Flow Cooling Tower Performance Anaysis and Experiments

  • Seo, Moo-Gyo;Kim, Young-Soo;Kim, Eun-Pil;Yoon, Jung-In
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.1
    • /
    • pp.50-57
    • /
    • 2001
  • The thermal performance of cooling towers is affected by the temperature of inlet water, wet bulb temperature of entering air and water-air flow rate. In this stud${\gamma}$, the effects of these variables are simulated using NTU-method and experimentally investigated for the counter-flow cooling towers. The simulation program to evaluate these variables which affect the performance of cooling tower was developed. The maximum errors between the results of simulations and experiments were 3.8% under the standard design conditions and 5.4% under the other conditions. The performance was increased up to 46~50% as the water loading was increased from 6.8$m^3/hr{\cdot}m^2$ to 159$m^3/hr{\cdot}m^2$. The range was reduced up to 56~42% when the wet bulb temperature of the entering air was increased from 22${\circ}C$ to 29${\circ}C$.

  • PDF

Flow Labeling Method for Realtime Detection of Heavy Traffic Sources (대량 트래픽 전송자의 실시간 탐지를 위한 플로우 라벨링 방법)

  • Lee, KyungHee;Nyang, DaeHun
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.2 no.10
    • /
    • pp.421-426
    • /
    • 2013
  • As a greater amount of traffic have been generated on the Internet, it becomes more important to know the size of each flow. Many research studies have been conducted on the traffic measurement, and mostly they have focused on how to increase the measurement accuracy with a limited amount of memory. In this paper, we propose an explicit flow labeling technique that can be used to find out the names of the top flows and to increase the counting upper bound of the existing scheme. The labeling technique is applied to CSM (Counter Sharing Method), the most recent traffic measurement algorithm, and the performance is evaluated using the CAIDA dataset.

The Effect of Feeding Characteristics on the Temperature Distribution of Rotary Kiln (로타리 킬른의 장입 특성이 온도분포에 미치는 영향)

  • Park, Jong-Seok;Chun, Chul-Kyun
    • Journal of the Korean Society of Combustion
    • /
    • v.12 no.3
    • /
    • pp.24-32
    • /
    • 2007
  • A theoretical model was developed for rotary kiln and computational study was conducted to find the effect of feeding characteristics. One dimensional model with the variations of heating distribution, length of heating zone, excess air ratio and revolution was considered. The comparison of parallel-flow rotary kiln with that of counter-flow was conducted. For parallel-flow type, it is found that the variation of temperature of solid is not great for the zone that is following flame-heating zone. This zone is good to take the special treatment because thermal deviation is small and contacting time is enough for another treatment. Increase of excess air ratio have the effect of decreasing solid temperature. But this effect of decreasing solid temperature goes small for the great excess air ratio. The heating is efficient for the flame which has the maximum heating at the central region of the full length.

  • PDF

The study on heat transfer enhancement using indirect cooling system in the channel with heat source (간접냉각방식을 이용한 열원이 부착된 채널내의 열전달 촉진에 관한 연구)

  • 김광추;박만흥;윤준규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.321-331
    • /
    • 1999
  • A numerical study is carried out for increasing heat removal using indirect cooling system. Computation is performed for nine cases as variation of flow condition in the lower channel. As the result of this study, water is more effective than air at the same pressure loss in spite of the lower inlet velocity. In channel configuration, the vertical channel is more effective than horizontal channel because of the buoyancy effect. Under the condition that heat generation is the same, counter flow effectively decreases the temperature difference among blocks. Parallel flow is more effective than counter flow when average temperature of all blocks is considered. In the case of installing obstacles in the lower channel, it is desirable to install obstacles in the bottom of lower channel. Heat transfer rate increases as the height of obstacles increases.

  • PDF

Design of the recuperator for the gas turbine/fuel cell hybrid power generating system (가스터빈/연료전지 혼합발전 시스템의 열교환기 설계)

  • Kwak, Jae-Su;Yang, Soo-Seok;Lee, Dae-Sung
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2105-2110
    • /
    • 2004
  • Plate-fin type recuperators for the gas turbine/fuel cell hybrid power generating system were designed using commercial design software, MUSE. Heat transfer efficiency and total pressure drop in the recuperator were calculated to confirm required recuperator performance. Both counter flow and cross flow type plate-fin recuperators were designed. Results show that the counter flow type has higher efficiency and short core length, but the cross flow type is simpler to construct because the cross flow type does not need additional distributors. Two or three headers for the each recuperator core will be designed and tested to evaluate best header design. The designed recuperators and headers which will be designed later will be constructed, tested, and used in gas turbine/fuel cell hybrid power generating system.

  • PDF

Pharmacokinetic Modeling and Simulation of the Carrier-Mediated Hepatic Transport of Organic Anions (음이온계 약물의 간수송과정에 있어서 담체매개 수송의 약물동력학적 모델링 및 시뮬레이션)

  • 이준섭;강민희;김묘경;이명구;정석재;심창구;정연복
    • YAKHAK HOEJI
    • /
    • v.47 no.2
    • /
    • pp.110-119
    • /
    • 2003
  • The purpose of the present study was to kinetically investigate the carrier-mediated uptake in the hepatic transport of organic anions, and to simulate the ″in vivo counter-transport″ phenomena, using kinetic model which was developed in this study. The condition that the mobility of carrier-ligand complex is greater than that of free carrier is not essential for the occurrence of ″counter-transport″ phenomenon. To examine the inhibitory effects on the initial uptake of a ligand by the liver, it is necessary to judge whether the true counter-transport mechanism (trans-stimulation) is working or not. The initial plasma disappearance curves of a organic anion were then kinetically analyzed based on a flow model, in which the ligand is eliminated only from the peripheral compartment (liver compartment). Moreover, ″in vive counter-transport″ phenomena were simulated based on the perfusion model which incorporated the carrier-mediated transport and the saturable intracellular binding. The ″in vivo counter-transport″ phenomena in the hepatic transport of a organic anion were well demonstrated by incorporating the carrier-mediated process. However, the ″in vivo counter-transport″ phenomena may be also explained by the enhancement of back diffusion due to the displacement of intracellular binding. In conclusion, one should be more cautious in interpreting data obtained from so-called ″in vivo counter-transport″ experiments.

An Experimental Study on Heat transfer Characteristics in Micro Plate Heat Exchangers with Counter flow of Microchannel (대향류 마이크로 채널 판형 열교환기의 열전달 특성 실험적 연구)

  • Seo, Jang-Won;Kim, Yoon-Ho;Moon, Chung-Eun;Lee, Kyu-Jung
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.229-234
    • /
    • 2007
  • Microscale heat transfer and microfluidics have become increasingly important to overcome some very complex engineering challenges. The use of very small passages to gain heat transfer enhancement is a well documented method for achieving high heat flux dissipation. As the passage size is decreased, the heat transfer performance increases but the pressure drop increases sharply when the passage size is reduced. In this study, the performance evaluation of micro plated heat exchangers under the counter flows with straight, V-shaped and Y-shaped channel are carried out.

  • PDF