• Title/Summary/Keyword: Counter Mass

검색결과 200건 처리시간 0.027초

열펌프를 이용한 R22대체 혼합냉매의 성능에 관한 연구 (A Study on the Performance of HCFC22 and Alternative Refrigerants in Heat Pumps)

  • 송영재;정동수
    • 태양에너지
    • /
    • 제18권1호
    • /
    • pp.69-79
    • /
    • 1998
  • This paper is concerned about the performance of HCFC22 alternative refrigerants used in heat pumps and industrial chillers. A water-to-water breadboard heat pump with counter-current heat exchangers and a hermetic compressor was built to carry out the experiments with various refrigerants. For each test, more than 40 temperatures, 4 pressures, power input, mass flow rates of the heat transfer fluids were measured. Refrigerants tested were HCFC22, R290(Propane), an azeotrope of 45%Propane/55%R134a mixture, and a nonazeotropic mixture of Calor 50. All tests were conducted under ARI test A condition. It is found that the COP and capacity of propane were 18% and 2.5% higher than those of HCFC22 while the COP and capacity of 45%Propane/55%R134a mixture were 3.5% and 5.3% higher than those of HCFC22 respectively. Also the COP and capacity of Calor 50 were 17% and 7.8% higher than those of HCFC22. Compressor discharge temperatures of alternative refrigerants were roughly $35^{\circ}C$ lower than that of HCFC22 indicating that these refrigerants are good from the view point of compressor reliability. The charging amounts for the alternative refrigerants were reduced by 40-60% as compared to that of HCFC22. Overall, it can be said that hydrocarbon containing alternative refrigerants are excellent in thermodynamic performance but should be used with considerable care due to their flammability.

  • PDF

화력발전소에서의 인적오류 사례 및 개선방안 (A Case Study on Human Errors in Thermal Power Plant)

  • 박영규;전상기;김봉빈;김윤경;정창우
    • 산업공학
    • /
    • 제21권3호
    • /
    • pp.247-253
    • /
    • 2008
  • There are various types of unexpected troubles in service of a thermal power plant, which consists of many complicated high-tech mass equipments. The troubles are mostly caused by the manufacturing defects, the material deteriorations, the human errors, and others. Failures of its system due to the troubles, can bring on the extravagant economic loss and the qualitative degradation of electricity. Especially, it is most important to find a way to decrease human errors because it can result in not only the economic loss, but also morale declination of employees or the department related to the trouble. Therefore, we categorize previous troubles related to the human errors, and try to show the causations and the counter-measures based on the various categories such as maintenance, an operation, and system of the thermal power plants.

프로필렌 냉매의 증발열전달 특성에 관한 실험적 연구 (Experimental Study on Heat Transfer Characteristics of Evaporation using Propylene Refrigerant)

  • 이호생;김재돌;정석권;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권5호
    • /
    • pp.754-761
    • /
    • 2004
  • In this paper, evaporating heat transfer characteristics in the refrigeration and air-conditioning facilities were studied using the environmentally friendly refrigerants R-1270 (Propylene). R-290 (Propane). R-600a (Iso-butane) and HCFC refrigerant R-22 The test tube was surrounded by an annulus with water flowing counter to the refrigerant. The tube is copper. with an outside diameter of 12.7mm and the wall thickness of 1.315mm. The test results showed that the local evaporating heat transfer coefficients of hydrocarbon refrigerants were superior to that of R-22 and the maximum increasing rate of heat transfer coefficient was found in R-1270. The average evaporating heat transfer coefficient increased with the increase of the mass velocity and it showed the higher values in hydrocarbon refrigerants than R-22 Comparing the heat transfer coefficient of experimental results with that of other correlations. the presented results had agood agreement with the Kandlikar's correlation. This results form the investigation can be used in the design of heat transfer exchangers using hydrocarbons as the refrigerant for the air-conditioning systems.

비구형 입자의 형상에 따른 단극 확산 하전 특성 (Effects of Particle Shapes on Unipolar Diffusion Charging of Non-Spherical Particles)

  • 오현철;박형호;김상수
    • 대한기계학회논문집B
    • /
    • 제28권5호
    • /
    • pp.501-509
    • /
    • 2004
  • Unipolar diffusion charging of non-spherical particles was investigated for various particle shapes. We researched with TiO$_2$agglomerates produced by the thermal decomposition of titanium tetraisopropoxide (TTIP) vapor. TTIP was converted into TiO$_2$, in the furnace reactor and was subsequently introduced into the sintering furnace. Increasing the temperature in the sintering furnace, aggregates were restructured into higher fractal dimensions. The aggregates were classified according to their mobility using a differential mobility analyzer. The projection area and the mass fractal dimension of particles were measured with an image processing technique performed by using transmission electron microscope (TEM) photograph. The selected aggregates were charged by the indirect photoelectric-charger and the average number of charges per particle was measured by an aerosol electrometer and a condensation particle counter. For the particles of same mobility diameter, our results showed that the particle charge quantity decreases as the sintering temperature increases. This result is understandable because particles with lower fractal dimension have larger capacitance and geometric surface area.

석탄연소 보일러에서 생성된 석탄회의 분석과 형성 메커니즘 해석에 대한 연구 (A Study on the Formation Mechanism of the Fly Ash from Coal Particles in the Coal Burning Boiler)

  • 이정언;이재근
    • 대한기계학회논문집B
    • /
    • 제22권12호
    • /
    • pp.1691-1701
    • /
    • 1998
  • Fly ash produced in coal combustion is a fine-grained material consisting mostly of spherical, glassy, and porous particles. A study on the formation mechanism of the fly ash from coal particles in the pulverized coal power plant is investigated with a physical, morphological, and chemical characteristic analysis of fly ash collected from the Samchonpo power plant. This study may contribute to the data base of domestic fly ash, the improvement of combustion efficiency, fouling phenomena and ash collection in the electrostatic precipitator. The physical property of fly ash is determined using a particle counter for the measurement of ash size distribution. Morphological characteristic of fly ash is performed using a scanning electron micrograph. The chemical components of fly ash are determined using an inductively coupled plasma emission spectrometry(ICP). The distribution of fly ash size was bi-modal and ranged from 12 to $19{\mu}m$ in mass median diameter. Exposure conditions of flue gas temperature and duration within the combustion zone of the boiler played an important role on the morphological properties of the fly ash such as shape, particle size and chemical components. The evolution of ash formation during pulverized coal combustion has revealed three major mechanisms by large particle formation due to break-up process, gas to particle conversion and growth by coagulation and agglomeration.

정적 연소실에서 성층화된 혼합기 조건하의 점화 전극사이 당량비 측정과 연소 특성에 미치는 영향 (Measurements of Equivalence Ratio in the Spark Plug Gap and Its-Effects on Combustion Under Stratified Mixture Conditions in a Constant Volume Chamber)

  • 배상수;이기철;민경덕
    • 대한기계학회논문집B
    • /
    • 제25권10호
    • /
    • pp.1311-1317
    • /
    • 2001
  • To investigate only the effects of the stratified mixture distribution on initial flame propagation and combustion characteristics, the instantaneous equivalence ratio in the spark plug gap and combustion pressure were measured simultaneously In a constant volume chamber, To induce the stratified propane-air mixture distribution near the spark plug, counter-flow typed mixture injection system was used under the constant mean equivalence ratio $\Phi$$\_$mean/= 1.0 The instantaneous equivalence ratio was measured by a single-shot Raman scattering with narrow-band KrF excimer laser. The measuring error was within the limit of $\pm$ 3.5% provided that the proposed method was applied to the measured Raman signals. Judging from mass fraction burned derived from the measured pressure, the optimum combustion characteristics were shown under the condition that the local equivalence ratio in the spark plug was near 1.28$\pm$0.04, and these characteristics were more remarkable at the initial stage of combustion.

테러리즘 위협 예방과 경호정보의 역할 (Prevention of Terrorism Threat and Role of Security Intelligence in New Terrorism)

  • 백종갑;김태환
    • 한국재난정보학회 논문집
    • /
    • 제1권1호
    • /
    • pp.43-71
    • /
    • 2005
  • Terrorism is the use of violence, especially murder and bombing, in order to achieve political aim or to force a government to do something. Nowadays, instrument of mass destruction are smaller, cheaper, and more readily available. Cellular phones were used as timers in the attacks in Madrid last March. Hijacking an airplane is relatively inexpensive. Finally, the information revolution provides inexpensive means of communication and organization that allow groups once restricted to local and national police jurisdictions to become global. Al Qaeda is said to have established a network in fifty or more countries. These technological and ideological trends increased both the lethality and the difficulty of managing terrorism. Because of the unprecedented scale of Al Qaeda's attacks, the focus is properly on Islamic extremists. But it would be a mistake to limit our concern solely to Islamic terrorists, for that would ignore the way that technology is putting into the hands of deviant groups and individuals' destructive capabilities that were once limited primarily to governments and armies.

  • PDF

프로판/부탄 혼합자연냉매의 평활관과 마이크로핀관 내의 응축성능평가 (Condensing Performance Evaluation in Smooth and Micro-Fin Tubes for Natural Mixture Refrigerant (Propane/Butane))

  • 이상무;이주동;박병덕
    • 설비공학논문집
    • /
    • 제17권9호
    • /
    • pp.816-823
    • /
    • 2005
  • This paper deals with the heat exchange performance prediction of a counter flow type double-tube condenser for natural refrigerant mixtures composed of Propane/n-Butane or Propane/i-Butane in a smooth tube and a micro-fin tube. The local characteristics of heat transfer, mass transfer and pressure drop are calculated using a prediction method developed by the authors. The total pressure drop and the overall heat transfer coefficient are also evaluated on various heat exchange conditions. The calculated results of the natural refrigerant mixtures are compared with HCFC22. In conclusion, natural refrigerant mixtures composed of Propane/n-Butane or Propane/i-Butane are appropriate candidates for alternative refrigerant from the viewpoint of heat transfer characteristics.

PWR Hot Leg Natural Circulation Modeling with MELCOR Code

  • Park, Jae-Hong;Lee, Jong-In;Randall. K. Cole;Randall. O. Gauntt
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 추계학술발표회논문집(1)
    • /
    • pp.772-777
    • /
    • 1997
  • Previous MELCOR and SCDAP/RELAP5 nodalizations for simulating the counter-current, natural circulation behavior of vapor flow within the RCS hot legs and SG U-tubes when core damage progress can not be applied to the steady state and water-filled conditions during the initial period of accident progression because of the artificially high loss coefficients in the hot legs and SG U-tubes which were chosen from results of COMMIX calculation and the Westinghouse natural circulation experiments in a 1/7-scale facility for simulating steam natural circulation behavior in the vessel and in the hot leg and SG during the TMLB' scenrio. The objective of this study is to develop a natural circulation modeling which can be used both for the liquid flow condition at steady state and for the vapor flow condition at the later period of in-vessel core damage. For this, the drag forces resulting from the momentum exchange effects between the two vapor streams in the hot leg was modeled as a pressure drop by pump model. This hot leg natural circulation modeling of MELCOR was able to reproduce similar mass flow rates with those predicted by previous models.

  • PDF

AndroScope: An Insightful Performance Analyzer for All Software Layers of the Android-Based Systems

  • Cho, Myeongjin;Lee, Ho Jin;Kim, Minseong;Kim, Seon Wook
    • ETRI Journal
    • /
    • 제35권2호
    • /
    • pp.259-269
    • /
    • 2013
  • Android has become the most popular platform for mobile devices. However, Android still has critical performance issues, such as "application not responding" errors and hiccups resulting from garbage collection. Many phone vendors have tried to resolve the problems by characterizing and improving the performance. However, there are few insightful performance analysis tools for the Android-based systems. This paper presents AndroScope, which is a performance analysis tool for both the Android platform (Dalvik virtual machine, core libraries, Android libraries, and even Linux kernels) and its applications. To the best of our knowledge, this is the first tool to collect and analyze performance data from all the software layers of the Android-based systems. AndroScope offers a trace mechanism to collect such deep and wide performance data as hardware performance counters, time, and memory usage. In addition, the tool includes TraceBridge, which is a middleware for the fast handling of mass logs. Moreover, AndroScope offers an integrated graphical user interface with the Android software development kit to display a great volume of the detailed performance data.