• Title/Summary/Keyword: Counter Mass

Search Result 200, Processing Time 0.03 seconds

Analysis of Novel Magnetic-Spring Actuators for Portable Units (휴대장치용 새로운 자기 스프링 액추에이터의 해석)

  • 한인환
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.12
    • /
    • pp.1942-1949
    • /
    • 2004
  • SLA(Scanned Linear Array) is a portable display unit for implementing next-generation virtual realities, utilizes a design that light generated by a line of LEDs is reflected from the rapidly oscillating mirror to generate a raster display. Reaction forces generated by the motions of the mirror and counter-balance mass cancel each other at the device base, reducing vibration. Metal leaf springs have been extensively applied in such portable units. Magnetic springs have been developed and adopted that can replace the metal spring and can avoid many disadvantages of metal springs. We model and analyze the dynamics of the structure with magnetic springs and present the simulation and experimental analysis results, which can be utilized for identifying and eliminating possible problem sources in removing shaking forces and moments, and oscillating the mirror at the required amplitude and frequency. Finally, we present the improved novel magnetic actuator model which can be applied in portable display units.

Noninvasive measuring;Detections of materials and quantities on eddy current testing

  • Obayashi, Koji;Tamura, Muneyoshi;Zhang, X.;Aoyama, T.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1555-1560
    • /
    • 2004
  • We made a simplified eddy-current-tester, and observed some materials for the ingredients and mass and locations. The tester detects the current as frequency shifts of a LC-resonance circuit, which are caused by the eddy currents. Using air-wick coil and a multi-piled ceramic capacitor, we made a resonance system whose frequency was 100KHz. The shift quantity is few; so, to detect it, we used a frequency counter, and counted the shift. We can detect 10Hz order's shift.

  • PDF

Effect of Aromatherapy Program on Lowering BMI and Serum Estrogen Level in Obese Post-menopause Women (폐경 후 비만여성에게 적용한 향기요법 프로그램이 체질량감소와 혈청 에스토로겐에 미치는 효과)

  • Kim, Hee-Ja
    • Women's Health Nursing
    • /
    • v.14 no.2
    • /
    • pp.150-155
    • /
    • 2008
  • Purpose: The purpose of this study was to verify the effect of aromatherapy program on lowering body mass index and serum estrogen in obese post-menopause women. Method: One group Pretest-posttest experimental design was used. All subjects received intervention of aromatherapy program. The participants used 3% grapefruit oil, cypress and three other kinds of oil. BMI and Serum estrogen level of the participants' were measured by ZEUS 9.9(Resource Medical, 2004) and PACKARD Gamma Counter-Cobra II RI Manual(USA, 1997) before and after interventions being applied at the P. hospital. Data were analyzed by paired t-test using the SPSS/PC+Win 12 Version. Result: The level of serum estrogen and BMI of the participants were significantly decreased after aromathetapy program. Conclusion: These results suggest that the effect of aromatheapy program could be utilized as an effective intervention to reduce BMI and serum estrogen level in obese post-menopause women.

  • PDF

NOx Production Characteristics of Offset-Opposed Impinging Jet Flame (Offset-대향 분출혐의 NOx 생성특징)

  • Seo, Jong-Won;Lee, Chang-Jin
    • 한국연소학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.1-9
    • /
    • 1999
  • The NOx production and combustion characteristics are experimentally compared with an offset with counter-orifice configuration. The offset-opposed impinging flame creates stronger vortex around the stagnation point than the opposed flame. The thermal and mass mixtures be improved and the delay of turbulence dissipation be occurred by the strong vortex. In result, the turbulent flame structure transferred from the wrinkled flame and the corrugated flame to the distributed reaction flame. It was found that the offset-opposed impinging flame decreased more NOx and improved the combustion efficiency than the opposed flame. The principal objective of this study is to develop the low NOx combustor by distributed reaction flame.

  • PDF

Numerical Analysis on Thermal Transpiration Flows for a Micro Pump (열천이 현상을 이용한 마이크로 펌프내의 희박기체유동 해석)

  • Heo, Joong-Sik;Lee, Jong-Chul;Hwang, Young-Kyu;Kim, Youn-J.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.493-496
    • /
    • 2006
  • Rarefied gas flows through two-dimensional micro channels are studied numerically for the performance optimization of a nanomembrane-based Knudsen compressor. The effects of the wall temperature distributions on the thermal transpiration flow patterns are examined. The flow has a pumping effect, and the mass flow rates through the channel are calculated. The results show that a steady one-way flow is induced for a wide range of the Knudsen number. The DSMC(direct simulation Monte Carlo) method with VHS(variable hard sphere) model and NTC(no time counter) techniques has been applied in this work to obtain numerical solutions.

  • PDF

A Study on the Development of the Netherlands' Contemporary Art Furniture (현대 네덜란드 아트퍼니처 전개 양상에 관한 연구)

  • Choi, Byung Hoon;Jung, Jaenah
    • Journal of the Korea Furniture Society
    • /
    • v.26 no.4
    • /
    • pp.291-300
    • /
    • 2015
  • The Netherlands' contemporary Art Furniture has drawn large attention from design and art fields all around the world because of Dutch designers' intriguing themes and experimental approaches. Its successful achievement not comes from certain policies or personalities, but the result of ceaseless internal criticisms and self examinations. After World War II, Modernism was the most common notion of furniture design for mass production in the Netherlands like other nations, but Dutch designers and critics put modernist canon up for discussion since 1960s. They have searched counter modernist design for expression of human element and warmth using art works, craft, and Postmodernism theory, etc. Throughout design debate of modernism, free design, design as art and conceptual design, now we could observe Dutch designer's unique and distinguished Art Furniture in the influential places. By analyzing the development of the Netherlands' contemporary Art Furniture in chronological sequences, we could understand them better and learn something useful to Art Furniture in South Korea.

Active Flow Control Using the Synthetic Jet Actuator (Synthetic Jet Actuator를 이용한 능동 유동 제어)

  • Noh Jongmin;Kim Chongam
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.65-69
    • /
    • 2005
  • Curretly, the development of MEMS(Micro Electronic Mechanical System) technology awakes many research's interest for the aerodynamics. This work presents the development of a compact synthetic jet actuator for flow separation control at the flat plate. The formation and evolution of fluidic actuators based on synthetic jet technology are investigated using Reynolds-Averaged Navier-Stokes equations. Also, 2-Dimensional, unsteady, incompressible Navier-Stokes equation solver with single partitioning method for Multi-Block grid to analyze and a modeled boundary condition in developed fo. the synthetic jet actuator. Both laminar and turbulent jets are investigated. Results show very good agreement with experimental measurements. A jet flow develops, even though no net mass flow is introduced. Pair of counter-rotating vortices are observed near the jet exit as are observed in the experiments.

  • PDF

Design of X-Y Actuator with High Vibration Resistance lot Probe-based Data Storages (탐침형 정보저장장치용 이차원 구동기의 내진 구조)

  • Lee, Kyoung-Il;Kim, Seong-Hyun;Cho, Jin-Woo;Choi, Young-Jin;Shin, Jin-Koo
    • 정보저장시스템학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.195-196
    • /
    • 2005
  • We report the new design of a miniature electromagnetic actuator for probe-based data storage with anti-vibration mechanism. The actuator consists of a media substrate, silicon frame, 2 pairs of magnets, a spacer, and a printed circuit board (PCB). The total area of the device is $11.2{\times}11.2 mm^2$ while the data recording area is $7.4{\times}7.4 mm^2$. A net momentum fee structure was included for high vibration resistance. The simulation shows that the lateral vibration can be reduced to below 100 nm for 1 G acceleration if the counter mass is adjusted with $1\%$ difference. The peak power for ${\pm}50 {\mu}m$ displacement is below 50 mW for a actuator with a resonance at 200 Hz.

  • PDF

Numerical Analysis on Thermal Transpiration Flows for a Micro Pump (열천이 현상을 이용한 마이크로 펌프내의 희박기체유동 해석)

  • Heo, Joong-Sik;Lee, Jong-Chul;Hwang, Young-Kyu;Kim, Youn-J.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.5
    • /
    • pp.27-33
    • /
    • 2007
  • Rarefied gas flows through two-dimensional micro channels are studied numerically for the performance optimization of a nanomembrane-based Knudsen compressor. The effects of the wall temperature distributions on the thermal transpiration flow patterns are examined. The flow has a pumping effect, and the mass flow rates through the channel are calculated. The results show that a steady one-way flow is induced for a wide range of the Knudsen number. The DSMC(direct simulation Monte Carlo) method with VHS(variable hard sphere) model and NTC(no time counter) techniques has been applied in this work to obtain numerical solutions. A critical element that drives Knudsen compressor Is the thermal transpiration membrane. The membranes are based on aerosol or machined aerogel. The aerogel is modeled as a single micro flow channel.

이젝터가 부착된 냉동시스템의 성능실험

  • 이원희;김윤조;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.10
    • /
    • pp.993-1001
    • /
    • 2001
  • Experimental investigation on the performance of dual-evaporator refrigeration system with an ejector has been carried out. In this study, a hydrofluorocarbon (HFC) refrigerant R134a is chosen as a working fluid. The condenser and two-evaporators are made as concentric double pipes with counter-flow type heat exchangers. Experiments were performed by changing the inlet and outlet temperatures of secondary fluids entering condenser, high-pressure evaporator and low-pressure evaporator at test conditions keeping a constant compressor speed. When the external conditions (inlet temperatures of secondary fluid entering condenser and one evaporator) are fixed, results show that coefficient of performance (COP) increases as the inlet temperature of the other evaporator rises. It is also shown that the COP decreases as the mass flaw rate ratio of suction fluid to motive fluid increases. The COP of dual-evaporator refrigeration system with an ejector is superior to that of a single-evaporator vapor compression system by 3 to 6%.

  • PDF