• 제목/요약/키워드: Counter Flow

검색결과 492건 처리시간 0.031초

대향류와 평행류형 판형 증발기에서 운전방식에 따른 성능특성 분석 (Analysis of Performance Characteristics in the Counter and Parallel Type Plate Evaporator with Operating Methods)

  • 배경진;차동안;권오경
    • 동력기계공학회지
    • /
    • 제17권3호
    • /
    • pp.50-56
    • /
    • 2013
  • The analysis of performance characteristics was carried out in the plate type evaporator with counter and parallel flow. To investigate performance of evaporator with water inlet temperature and refrigerant mass flow rate were changed. As a result, when the inlet temperature of water is $8^{\circ}C$, capacity of parallel flow evaporator higher than counter flow is 0.35%. But as the inlet temperature of water rises from $8^{\circ}C$ to $16^{\circ}C$, capacity of counter flow type evaporator higher than parallel flow type is 0.12%, 0.27%, 1.1%, 1.6%, respectively. The findings showed that counter flow type evaporator has a larger capacity than those that were parallel flow type evaporator. As the refrigerant mass flow rate rises, capacity and pressure drop increases in the counter and parallel flow type evaporator.

엇회전식 축류팬의 비정상 유동특성에 관한 실험적 연구 (Experimental Study on the Unsteady Flow Characteristics of the Counter-Rotating Axial Flow Fan)

  • 조이상;최현민;강정식;조진수
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제29회 추계학술대회논문집
    • /
    • pp.305-310
    • /
    • 2007
  • 엇회전식 축류팬의 복잡한 유동특성을 이해하고 설계, 공력 해석 및 소음 특성 예측에 활용될 수 있는 3차원 비정상 유동장을 측정하였다. 엇회전식 축류팬의 3차원 비정상 유동장은 작동 영역인 설계점에서 $45^{\circ}$ 경사 열선을 이용하여 전단 동익의 전방, 전단 동익과 후단 동익 사이 그리고 후단 동익의 후방의 수직 유로 단면에서 측정되었다. 엇회전식 축류팬의 전단 동익과 후단 동익에 의해 발생되는 후류, 팁 와류 및 팁 누설 유동의 비정상 특성을 속도 벡터와 속도 윤곽을 통해 나타내었다.

  • PDF

Drag Reduction Effect by Counter-flow Jet on Conventional Rocket Configuration in Supersonic/Hypersonic Flow

  • Kim, Yongchan;Kim, Duk-Min;Roh, Tae-Seong;Lee, Hyoung Jin
    • 항공우주시스템공학회지
    • /
    • 제14권4호
    • /
    • pp.18-24
    • /
    • 2020
  • The counter-flow jet from a supersonic/hypersonic vehicle causes a structural change in the shock wave generated around the aircraft, which can lead to reduced drag and heat loads. Since the idea is to mount a counter-flow jet device for drag reduction in the aircraft, it is necessary to understand the effect of such a device on the entire aircraft. In this study, the effect of drag reduction due to counter-flow jet on a conventional rocket configuration was analyzed through CFD analysis. The results showed that the drag reduction effect was the largest in the blunt region and that the counter-flow jet also affected the downstream of the aircraft. The analysis indicated that the drag reduction effect by the counter-flow jet was about 10 to 25 % when targeting the entire rocket-shaped area, while the effect was as high as 50% when targeting only blunt objects.

고성능 엇회전식 축류팬의 공력특성에 대한 전산해석 (Numerical analyses on the Aerodynamic Characteristics of a Counter-rotating Axial Flow Fan)

  • 조이상;조진수
    • 융복합기술연구소 논문집
    • /
    • 제5권1호
    • /
    • pp.37-40
    • /
    • 2015
  • Numerical analyses on the aerodynamic characteristics of a counter rotating axial flow fan is carried out using the frequency domain panel method. Front rotor and rear rotor blades of a counter rotating axial fan are designed by using the simplified meridional flow analysis method with the radial equilibrium equation and the free vortex design condition, according to design requirements. Performance characteristics of a counter rotating axial flow fan are estimated for the variation of design parameters such as the hub to tip ratio, the taper ratio and the solidity. Pressure losses were higher at leading edge and hub region of rotor blades. Characteristic curve of the counter rotating fan was overpredicted without consideration of viscous effect.

엇회전식 축류팬의 3차원 비정상 유동에 관한 실험적 연구 (Experimental Study on the Three Dimensional Unsteady Flow in a Counter-Rotating Axial Flow Fan)

  • 박현수;조이상;조진수
    • 대한기계학회논문집B
    • /
    • 제28권9호
    • /
    • pp.1005-1014
    • /
    • 2004
  • Experiments were done for the three dimensional unsteady flow in a counter-rotating axial flow fan under peak efficiency operating condition. Flow fields in a counter rotating axial flow fan were measured at cross-sectional planes of the upstream and downstream of each rotor. Cross sectional flow patterns were investigated through the acquired data by the 45$^{\circ}$ inclined hot-wire. Flow characteristics such as tip vortex, secondary flow and tip leakage flow were confirmed through axial, radial and tangential velocity vector plot. It has been found that the radial and tangential velocity components disappeared, while the axial velocity component highly increased as soon as the tip vortex was generated. It has been observed that secondary flow and turbulence intensity which were increased by the front rotor were dissipated passing through the rear rotor. As the result the energy loss of the counter rotating axial flow fan decreased at the downstream of rear rotor. Also, it has been verified that tip vortex pattern of the rear rotor was dampened because the tip vortex generated by front rotor was mixed with that of the rear rotor.

엇회전식 축류팬의 작동조건 변화에 따른 비정상 유동에 관한 실험적 연구 (Experimental Study on the Unsteady Flow under Various Operating Conditions of a Counter Rotating Axial Flow Fan)

  • 강현구;조이상;조진수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1389-1394
    • /
    • 2004
  • Experiments were done for the unsteady flow in a counter rotating axial flow fan near peak efficiency and stall point. Flow fields in a counter rotating axial flow fan were measured at cross-sectional planes of the upstream and downstream of each rotor. Cross sectional passage flow patterns were investigated through the acquired data by the $45^{\circ}$ inclined hot-wire. Comparison of flow characteristics between two different operating conditions such as tip vortex, secondary flow and turbulence intensity were performed through the analyses of axial, radial and tangential velocity distributions. As a result, tip vortex and secondary flows are enforced and measured obviously at stall point.

  • PDF

엇회전식 축류팬의 3 차원 비정상 유동에 관한 실험적 연구 (Experimental Study on the Three Dimensional Unsteady Flow in a Counter Rotating Axial Flow Fan)

  • 박현수;조이상;강현구;조진수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.822-827
    • /
    • 2003
  • Experiments were done for the three dimensional unsteady flow in a counter rotating axial flow fan under stable operating condition. Flow fields in a counter rotating axial flow fan were measured at cross-sectional planes of the upstream and downstream of each rotor. Cross sectional flow patterns were investigated through the acquired data by the $45^{\circ}$ inclined hot-wire. Flow characteristics such as tip vortex, secondary flow and tip leakage flow were confirmed through axial, radial and tangential velocity vector plot. Swirl velocity, which was generated by the front rotor, was recovered in the form of static pressure rise by the rear rotor except for hub and tip regions.

  • PDF

유동방향 변화에 따른 고분자 전해질 연료전지의 성능 및 전달특성에 대한 3차원 수치해석적 연구 (Three Dimensional Computational Study on Performance and Transport Characteristics of PEMFC by Flow Direction)

  • 이필형;한상석;황상순
    • 전기화학회지
    • /
    • 제11권1호
    • /
    • pp.51-58
    • /
    • 2008
  • 고분자 전해질 연료전지의 성능향상을 위한 방법으로 유동채널의 형상을 변경한 많은 연구가 진행되어 왔으나 동일한 유동채널 형상에서 유동방향 변경에 따른 연구는 많이 진행되지 못하였다. 본 연구에서는 동일한 반응면적과 동일한 유동채널의 고분자 전해질 연료전지의 수소와 산소의 유동방향을 Co-flow에서 Counter-flow로 변경될 경우의 연료전지의 성능변화를 분석하기 위하여 연료극과 공기극이 포함된 3차원 수치해석모델을 개발하였다. 개발된 수치해석모델을 활용하여 Co-flow와 Counter-flow의 유동채널 내부의 압력손실, 반응물질의 농도분포, 고분자 전해질 막을 통한 Water Transport, 고분자 전해질 막의 이온전도도 및 I-V 성능곡선을 비교하였다. 그 결과 반응물질의 농도분포, Water Transport, 고분자 전해질 막의 이온전도도가 우수한 Counter-flow 유동조건에서의 성능이 Co-flow 유동조건에 비하여 더욱 우수하였다.

다수의 계수구역간의 검사체적을 이용한 소형 세포농도센서 (Micro Cell Counter Using a Fixed Control Volume Between Double Electrical Sensing Zones)

  • 이동우;이소연;조영호
    • 대한기계학회논문집A
    • /
    • 제29권12권
    • /
    • pp.1615-1620
    • /
    • 2005
  • We present a novel flow-rate independent cell counter using a fixed control volume between double electrical sensing zones. The previous device based on the single electrical cell sensing in a given flow-rate requires an accurate fluid volume measurement or precision flow rate control. The present cell counter, however, offers the flow-rate independent method for the cell concentration measurement with counting cells in a fixed control volume of $22.9{\pm}0.98{\mu}{\ell}$. In the experimental study, using the RBC (Red Blood Cell), we have compared the measured RBC concentrations from the fabricated devices with those from Hemacytometer. The previous and present devices show the maximum errors of $20.3\%\;and\;16.1\%$, which are in the measurement error range of Hemacytometer (about $20\%$). The present device also shows the flow-rate independent performance at the constant flow-rates ($5{\mu}{\ell}/min$ and $10{\mu}{\ell}/min$) and the varying flow-rate (4, 2, and $4{\mu}{\ell}/min$). Therefore, we demonstrate that the present cell counter is a simple and automated method for the cell concentration measurement without requiring an accurate fluid measurement and precision flow-rate control.

엇회전식 축류 펜의 공력 특성에 관한 실험적 연구 (Experimental Study on the Aerodynamic Characteristics of a Counter-Rotating Axial Flow Fan)

  • 최진용;조이상;조진수;원유필
    • 대한기계학회논문집B
    • /
    • 제26권2호
    • /
    • pp.201-210
    • /
    • 2002
  • Experiments were done for performance and flow characteristics of a counter-rotating axial flow fan. Performance curves of a counter-rotating axial flow fan were obtained and compared by varying the blade pitch angles. The fan characteristic curves were obtained following the Korean Standard Testing Methods for Turbo Fans and Blowers (KS B 6311). The fan flow characteristics were measured using a five-hole probe and a slanted hot-wire. The velocity profiles between the hub and tip of the fans were measured and analyzed at the peak efficiency point. The peak efficiency of the counter-rotating axial flow fan was improved about 15% respectively, compared with the single rotating axial fan. The single rotating axial flow fan showed relatively law efficiency due to the swirl velocities behind rotor exit which produced pressure losses. The counter-rotating axial flow fan showed that the swirl velocity generated by the front rotor was eliminated by the rear rotor and the associated dynamic pressure is recovered in the from of the static pressure rise.