Study of Occurrence Tendency and Cause Analysis of Arson (방화의 발생추이와 원인분석)

  • 김동현;김광일
    • Fire Science and Engineering
    • /
    • v.12 no.1
    • /
    • pp.27-33
    • /
    • 1998
  • Arson is one of the serious crime. It shows high increasing rate compared with the past, and the causes of arson are getting diversified and specialized in this modern society. In this thesis, the actual state and tendency of arson during latest 5 years have been analyzed on the basis of 'crime analysis' which is material of the National Police Agency. Based on the above analyzed material, measures for arson in foreign countries are examined and necessary matters to counter arson in Korea are inferred.

  • PDF

A Study on the evaluation of the auditory guide facility under emergency situation (비상시 청각형 유도시설의 유도성능 평가에 관한 연구)

  • Na, Wook-Jung;Jeon, Gyu-Yeob;Hong, Won-Hwa
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1205-1208
    • /
    • 2006
  • Today, our city structure is being complicated from the development of industry. Invisible losses, life and fortune loss caused by arson is embossed in our society. The preparation of counter plan about increasing factors of fire damage is not easy. With respect to mankind life, however, it is very important. Therefore, the focus of this research examine refuge degree in each smoke density level when a fire break out in the space. I evaluated auditory guide facility thorough real scale test. In this thesis, I will propose the efficient refuge deriving facilities.

  • PDF

RSET Analysis According to the Width of Escape Routes in Large Supermarkets (대형마트의 피난로 폭에 따른 RSET 분석)

  • Boohyun Baek;Hongsang Lee;Hasung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.3
    • /
    • pp.29-38
    • /
    • 2024
  • The purpose of this study is to use an evacuation simulation program to measure the change in evacuation time according to the width of the evacuation route due to the installation of an intermediate sales counter and the placement of a shopping cart between the sales counters of a large supermarket and to analyze the results. Currently, the "Distribution Industry Development Act" does not regulate the size and installation method of intermediate sales counters installed between sales counters that serve as practical evacuation routes in the event of a fire at a large supermarket, the size of shopping carts, etc. Considering this, we set evacuation route widths of 40, 50, 60, 70, 80, and 100 cm and compared and analyzed evacuation times according to various variables in the facility space. As a result of the experiment, as the width of the evacuation route was expanded, there was a significant difference in the evacuation time, from a maximum of 468.3 seconds to a minimum of 320.8 seconds. Considering the safety of evacuees in large supermarkets used by many people, it is time to regulate the size of intermediate sales stands installed between sales counters in large supermarkets and shopping carts that can become obstacles in an emergency.

A Study on the Optimum Disaster Mitigation Activity to Establish the Early Counter System on the Industrial Accidents (산업체재난 조기 대응체계 구축을 위한 최적 재해경감활동 방안 연구)

  • Lee, Keun-Jae;Yoon, Myong-O;Lee, Won-Ho
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.9-20
    • /
    • 2010
  • This study indicates direction on establishment of the operational plan for disaster mitigation and its implementation for maintaining business continuity of the local company of the first step, and seeks plans for maintaining their continuity through the establishment of early counter system constructed for achieving lasting safe at the any disaster. For achieving it, we investigated the standard of disaster management selected by the government called "Incident Preparedness and Operational Continuity Plan" Guideline, and investigated a guideline to be easily applied to domestic companies. And, we also studied on how to build the operational plan of disaster mitigation and apply IT techniques to A corporation. Especially, this study indicates the models of establishment of risk assessment, impact analysis, prevention and mitigation plan, response management plan for the establishment of plan among 5 main steps on "Incident Preparedness and Operational Continuity Management" Guideline. We devised the plan to activate the disaster mitigation activity throughout the country. It shows the skills to be prepared to upgrade the level of disaster response in this study.

Numerical Study on the Isothermal Flow Field abound Rectangular Cross Section Bluff Body (사각형 둔각물체 주위의 유동장 특성에 관한 수치적 연구)

  • Lee, Jung-Ran;Lee, Eui-Ju
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.5
    • /
    • pp.35-41
    • /
    • 2012
  • The Numerical simulation was performed on the flow field around the two-dimensional rectangular bluff body in order to complement the previous experimental results of the bluff body stabilized flames [1]. For both fuel ejection configurations against an oxidizer stream, the flame stability was affected mainly by vortex structure and mixing field near bluff body. FDS(Fire Dynamic Simulator) based on the LES(Large Eddy Simulation) was employed to clarify the isothermal mixing characteristic and wake flow pattern around bluff body. The air used atmosphere and the fuel used methane. The result of counter flow configuration shows that the flow field depends on air velocity but the mixing field is influenced on the fuel velocity. At low fuel velocity the fuel mole fraction is below the flammable limit and hence the mixing is insufficient to react. Therefore, as the result, the flame formed at low fuel velocity is characterized by non-premixed flames. For the flow field of co-flow configuration, flame stability was affected by fuel velocity as well as air velocity. the vortex generated by fuel stream has counter rotating direction against the air stream. Therefore, the momentum ratio between air and fuel stream was important to decide the flame blow out limit, which is result in the characteristic of the partially premixed reacting wake near extinction.

A Study on Total Hazard Level Algorithm Development for Hazardous Chemical Substances (유해화학물질의 종합위해등급 알고리즘 개발에 관한 연구)

  • 고재선;김광일;정상태
    • Fire Science and Engineering
    • /
    • v.14 no.4
    • /
    • pp.7-16
    • /
    • 2000
  • In the study, three criteria(toxicity, fire & explosion, environment) and damage prediction method for each case was set up, and all these criteria were applied to the subject substance that was selected as hazardous level by integrating all criteria through Algorithm. Particularly, the environment criterion is a comprehensive concept, environment index modeling by combining USCG(United State Coast Guard) & MSDS(Material Safety Data Sheet) environment criteria classifications and the environment part of MFPA's health hazardousnes(Nh). And for damage prediction method of each criterion were adopted and they were applied to hazardous chemical substances in use or stored by chemical substance related enterprises located in each region that made possible to set up total hazard level of used substances(inflammability, poisonousness and counteraction on a unit substance, and hazard level & display modeling on environment) & damage prediction in case of accident & solidity setup(CPQRA: Chemical Process Quantitative Risk Assessment, IAEA: International Atomic Energy Agency, VZ eq: Vulnerable Zone) risk counter. Thus it is deemed that it can be applied to toxic substance leakage that can happen during any chemical processing & storage, application as a tool for prior safety evaluation through potential dangerousness computation of fire & explosion.

  • PDF

Counter Measures of the Subway Terrorism through Case Analysis (사례분석을 통한 지하철 테러에 대한 대책)

  • Kwon, Jeong-Hoon;Kim, Tae-Hwan;Choi, Jong-Gyun
    • Korean Security Journal
    • /
    • no.18
    • /
    • pp.1-20
    • /
    • 2009
  • Nowadays most nations around the world including Korea have experienced absolute shortages of available urban space. To solve various problems of the city, each nation constantly tends to extend the underground space. However there is a serious problem in making use of the underground space. Especially new terrorism coming into existence after 9.11 terror turns into the so-called ‘soft target’ which has something to do with public transportation facilities available to most people. Good examples are like these: poisonous gas attacks in Tokyo subway in 1995, Daegu subway station fire in 2003, serial bomb blast of London subway in 2005. In spite of being a concern on incidents related to the underground space it is inevitable to utilize the underground space and the tendency is growing. But Korea lags badly behind in foreign countries in this field and so seeking measures is urgently needed. Therefore the aim of this study is to note visible damages stemmed from the domestic and foreign underground space and propose more effective and adequate measures. Safety measures of terrorism are associated to minimize damage out of terrorism and they are as follows. In the first place, preparing protective equipment for saving a life from fire attacks and poisonous gas is needed urgently. In the second place, counterpart management on the spot and systematic security training should be established in order to minimize injury. In the third place, fire escapes must be provided for a rapid evacuation of potential unspecified individuals. In the fourth place, building up a network of related institutions is required for a systematic omnidirectional counterpart. Finally the Korean government ought to take fast and appropriate actions for the injured and bereaved family of the terror incident.

  • PDF

The Improvement of Evacuation Performance for Discount-Store in Underground (할인점 지하매장의 피난성능 개선에 관한 연구)

  • 김영일;윤명오;김종훈;김운형
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.93-99
    • /
    • 2001
  • This study aims to improve the Evacuation Performance o( the I)inc()unto-store in underground that is rapidly new shopping store in Korea. In this paper, The architectural properties of the floor plan and section was reviewed with egress focus, occupant load density of the Discount-store was surveyed and the procedure and method of performance based egress design for this occupancy was analysed with SIMULEX model and calculation method. As a result of modeling, more longer available safe egress time (ASET) is expected than required safe egress time (RSET)in underground discount-store. In order to improve the Evacuation Performance for this type occupancy, egress capacity including escape stair, aisle width, escape door is calculated with based on occupant load density and review of shopping cart's structure and size and maximum escape capacity of the cash counter.

  • PDF

Effects of Empowerment and Family Function on the Depression of Firefighters (소방공무원의 임파워먼트와 가족기능이 우울에 미치는 영향)

  • Choi, Hee-Chul
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.116-121
    • /
    • 2018
  • This study aimed to provide help to seeking a preventive method of intervention in firefighter's depression by investigating empowerment and family function level of firefighter's on their depression. For this, the study conducted purposive sampling survey among 351 firefighters at Gyeonggi area. As a result of the research, all of empowerment and family function had a significant effect on depression of firefighters. Based on these findings, the study demonstrated the potential for applying each individual's empowerment as an internal resource for their prevention of mental health. The study suggested that diverse counter measures are needed to boost family bond and family functionality of firefighters, and also proposed positive adoption and assistance for preventive and effective implementation of 'work and life balance' policy to derive the recovery of healthiness of families.

Performance Improvement of CO Sensor Signal Conditioner for Early Fire Detection System (조기화재 감시시스템을 위한 CO센서의 시그널컨디셔너 성능개선)

  • Park, Jong-Chan;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.2
    • /
    • pp.82-87
    • /
    • 2017
  • This paper presents performance improvement of CO gas sensor signal conditioner for early fire warning system. The warning system is based on the CO sensor and its advanced signal conditioning modules network that employ electochemical gas sensor. The electochemical has advantage of having a linear output and operating with a low consumption and fast response. This electrochemical gas sensor contains a gas membrane and three electrodes(working, counter, reference electrode) in contact with an electrolyte. To use a three-electrode sensor, a voltage has to be applied between the working and the reference electrode according to the specification of the sensor. In this paper, we designed these requirements that should be considered in temperature compensation algorithm and electrode measurement of CO sensor modules by using advanced signal conditioning method included 3-electrode. Simulation and experimental results show that signal conditioner of CO sensor module using 3-electrode have a advantage linearity, sensitivity and stability, fast response etc..