• Title/Summary/Keyword: Count loss

Search Result 249, Processing Time 0.031 seconds

Changes in quality characteristics of sliced garlic with different freezing conditions during storage (냉동조건에 따른 편마늘의 냉동저장 중 품질변화)

  • Kim, Seok-Young;Kim, Hee-Sun;Kim, Jin-Se;Han, Gwi-Jung
    • Food Science and Preservation
    • /
    • v.24 no.6
    • /
    • pp.746-757
    • /
    • 2017
  • This study was performed to evaluate the effect of different freezing conditions and storage periods on physicochemical and microbial characteristics of garlic. Garlics were washed, dried, sliced to 0.3 cm then packed in LDPE+LLDPE film bags. They were treated with still-air freezing at $-20^{\circ}C$ (SAF20), $-40^{\circ}C$ (SAF40) and immersed-liquid freezing at $-40^{\circ}C$ (ILF40). Frozen garlics were stored under frozen storage conditions for 7 months at $-20^{\circ}C$ and quality characteristics were measured monthly during the frozen storage. Freezing rate of garlic was the fastest in ILF 40 (10 min), SAF40 (40 min) and SAF20 (1,600 min) sequentially. In ILF40, drip loss, cutting force, total aerobic bacteria count and pH were the lowest, whereas pyruvic acid and allicin content were the highest (p<0.05) during frozen storage, these results were the most similar characteristics with the fresh garlic. During frozen storage, drip loss, color difference and total organic acid content were significantly fluctuated in SAF20 (p<0.05), while they were not changed in ILF40. Overall, total aerobic bacteria count and pH decreased, cutting force, pyruvic acid and allicin content remained unchanged in all groups. In conclusion, the optimal freezing conditions for garlic with the least quality changes was considered to be ILF40 (immersed liquid freezing), keeping quality characteristics up to 7 months by freezing storage.

Estimation of Internal Motion for Quantitative Improvement of Lung Tumor in Small Animal (소동물 폐종양의 정량적 개선을 위한 내부 움직임 평가)

  • Yu, Jung-Woo;Woo, Sang-Keun;Lee, Yong-Jin;Kim, Kyeong-Min;Kim, Jin-Su;Lee, Kyo-Chul;Park, Sang-Jun;Yu, Ran-Ji;Kang, Joo-Hyun;Ji, Young-Hoon;Chung, Yong-Hyun;Kim, Byung-Il;Lim, Sang-Moo
    • Progress in Medical Physics
    • /
    • v.22 no.3
    • /
    • pp.140-147
    • /
    • 2011
  • The purpose of this study was to estimate internal motion using molecular sieve for quantitative improvement of lung tumor and to localize lung tumor in the small animal PET image by evaluated data. Internal motion has been demonstrated in small animal lung region by molecular sieve contained radioactive substance. Molecular sieve for internal lung motion target was contained approximately 37 kBq Cu-64. The small animal PET images were obtained from Siemens Inveon scanner using external trigger system (BioVet). SD-Rat PET images were obtained at 60 min post injection of FDG 37 MBq/0.2 mL via tail vein for 20 min. Each line of response in the list-mode data was converted to sinogram gated frames (2~16 bin) by trigger signal obtained from BioVet. The sinogram data was reconstructed using OSEM 2D with 4 iterations. PET images were evaluated with count, SNR, FWHM from ROI drawn in the target region for quantitative tumor analysis. The size of molecular sieve motion target was $1.59{\times}2.50mm$. The reference motion target FWHM of vertical and horizontal was 2.91 mm and 1.43 mm, respectively. The vertical FWHM of static, 4 bin and 8 bin was 3.90 mm, 3.74 mm, and 3.16 mm, respectively. The horizontal FWHM of static, 4 bin and 8 bin was 2.21 mm, 2.06 mm, and 1.60 mm, respectively. Count of static, 4 bin, 8 bin, 12 bin and 16 bin was 4.10, 4.83, 5.59, 5.38, and 5.31, respectively. The SNR of static, 4 bin, 8 bin, 12 bin and 16 bin was 4.18, 4.05, 4.22, 3.89, and 3.58, respectively. The FWHM were improved in accordance with gate number increase. The count and SNR were not proportionately improve with gate number, but shown the highest value in specific bin number. We measured the optimal gate number what minimize the SNR loss and gain improved count when imaging lung tumor in small animal. The internal motion estimation provide localized tumor image and will be a useful method for organ motion prediction modeling without external motion monitoring system.

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

Energy Loss of Hydrogen Atom due to Charge Exchange in Neutral Particle Energy Analyzer (중성입자 에너지 분석장치에서 전하교환용 탄소박막에 의한 수소원자의 에너지 손실특성)

  • Kim, Kye-Ryung;Kim, Wan;Lee, Yong-Hyun;Kang, Hee-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.179-187
    • /
    • 1998
  • A neutral particle energy analyzer, which has the carbon stripping foil and the $90^{\circ}$ cylindrical electrostatic deflection plate, was designed and constructed for measuring of ion temperature in plasma. The energy calibration and energy resolution were studied in detail for a hydrogen ion at the $0.5{\sim}3.0\;keV$ energy using a duoplasmatron ion source. An energy of hydrogen ion to the deflection plate voltage at the peak ion count rate could be fitted by the expression $E_{o}(keV)$=3.83V(kV). The measured energy resolution, which was about 2 % at the energy of 3.0 keV and 9 % at the energy of 0.5keV, was better for the increased hydrogen ion energy. For the charge exchanged hydrogen atom due to the carbon stripping foil, the energy calibration, energy loss and resolution were measured to the $0.5{\sim}2.0{\mu}g/cm^{2}$ thickness of the carbon stripping foil. An energy of the charge exchanged hydrogen atom as a function of the deflection plate voltage and carbon foil thickness could be fitted by the expression $E_{o}(keV)=(0.53d+4.4){\cdot}V(kV)$. The energy loss was $0.23{\sim}0.89\;keV $ to the $0.5{\sim}2.0{\mu}g/cm^{2}$ carbon foil thickness and the $0.5{\sim}3.0\;keV$ energy of the incident neutral hydrogen atom, it could be fitted by the expression ${\Delta}E=(0.12d+0.27){\cdot}{E_{o}}^{1/2}(keV)$. The measured energy resolution for the neutral hydrogen atom, which was between 7 % and 35 % in this experiment region, was increased for the increasing neutral hydrogen atom energy and the decreasing carbon stripping foil thickness.

  • PDF

Effect of Ethane 1,2-Dimethane Sulfonate(EDS) on the Apoptosis in the Rat Epididymis (흰쥐 부정소에서의 세포자연사에 미치는 Ethane 1,2-Dimethane Sulfonate(EDS)의 효과)

  • Son, Hyeok-Jun;Lee, Sung-Ho
    • Development and Reproduction
    • /
    • v.10 no.3
    • /
    • pp.203-209
    • /
    • 2006
  • Ethane 1,2-Dimethane sulfonate(EDS), a toxin which specifically kills Leydig cells(LC), has been widely used to prepare the reversible testosterone(T) depletion rat model. Previous studies including our own clearly demonstrated that the dramatic weight loss of the T-dependent accessory sex organs such as epididymis and seminal vesicle in this 'LC knock-out' rats. These weight loss could be derived from massive and abrupt death of the cells via apoptotic process. The present study was performed to test the effect of EDS administration on the expression of some apoptotic genes in the rat epididymis. Adult male Sprague-Dawley rats($300{\sim}350$ g B.W.) were injected with single dose of EDS(75 mg/kg, i.p.) and sacrificed on Weeks 0, 1, 2, 3, 4, 5, 6 and 7. Tissue weights and the numbers of the epididymal sperm were measured. The transcriptional activities of the bcl-2, bax, Fas and Fas ligand(Fas-L) were evaluated by semi-quantitative RT-PCR. As expected, the weights and the sperm counts of epididymis declined progressively after the EDS treatment during Week 1 and 2. These decrements were discontinued with a gradual return towards normal during Weeks $5{\sim}7$, although the maximal recoveries of the epididymal weights(71%) and sperm count(38%) were subnormal on Week 7. The initial level of bcl-2 transcripts persisted to Week 6 then elevated significantly on Week 7. The level of bax transcripts significantly decreased on Week 6, and no remarkable change was found in the rest of the experimental period. The transcripts for the Fas in epididymis elevated during Weeks $1{\sim}2$, returned to normal on Week 3, and the level persisted to the Week 7. Similarly, the level of Fas-L transcripts elevated during Weeks $1{\sim}3$ and returned to normal after Week 4. Our results demonstrated the transient T depletion by EDS administration could induce the changes in expression of the apoptotic genes in rat epididymis. The activation of Fas and Fas-L in the epididymis of EDS-treated rats might be responsible for the initial apototic process and consequently the tissue damage and the sperm loss. Future studies will attempt to determine the precise molecular mechanism(s) of apoptosis in the rat epididymis.

  • PDF

Effect of Seasonal Distribution Temperature on Storability of Modified Atmosphere Packaged Baby Leaf Beet (계절별 수송 온도가 MA 포장한 어린잎 비트의 저장성에 미치는 영향)

  • Choi, In-Lee;Han, Su Jung;Kim, Ju Young;Ko, Young-Wook;Kim, Yongduk;Hwang, Myung-Keun;Yu, Wanggun;Kang, Ho-Min
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.24 no.2
    • /
    • pp.85-89
    • /
    • 2018
  • The effects of distribution temperature due to season all changes on quality and storability of baby leaf beet (Beta vulgaris L.) was examined in modified atmosphere (MA) packages. The beet leaf had been harvested at the 10 cm leaf length stage and packaged with an oxygen transmission rate (OTR) film of $1,300cc{\cdot}m^{-2}{\cdot}day^{-1}{\cdot}atm^{-1}$ and then held at 4 different distribution temperatures which were $-2^{\circ}C$, $4^{\circ}C$, $20^{\circ}C$, or $30^{\circ}C$ for 5 hrs and then stored for 18 days at $8^{\circ}C$. The loss of fresh weight of packged baby leaf beet was lowest at the $4^{\circ}C$ treatment, and below 0.6% in all distribution temperature treatments. The atmosphere composition in packages did not show any significant differences among treatments. The oxygen conc. was the highest at 18.0% after the $4^{\circ}C$ treatment, carbon dioxide conc. showed the maximum value of 4% at the $30^{\circ}C$ and $-2^{\circ}C$ treatments, and ethylene conc. was highest at the $10^{\circ}C$ treatment after 10 days in storage. The hardness was the highest at the $4^{\circ}C$ treatment on the final storage day. The $4^{\circ}C$ treatment showed the highest visual quality and the lowest off-odor and aerobic plate count. Therefore, it is necessary to establish a low-temperature distribution system which is controlled under $4^{\circ}C$, because the baby leaf beet's storability and microbial growth are effected even during a short time of 5 hrs during the distribution process.

The Inflammatory Response in Mouse Lung after Acute Sulfur Dioxide Exposure (급성 아황산가스 폭로후 흰쥐의 폐에 유발된 염증반응에 관한 연구)

  • Chin, Young-Joo;Park, Nam-Gyu;Lee, Hyeon-Suk;Kim, Dae-Soo;Earm, Jae-Ho;Cho, Myeong-Chan;Yoon, Sei-Jin;Jeong, Hwa-Sook;Song, Hyung-Geun;Sung, Ro-Hyun;Lee, Sang-Do
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.4
    • /
    • pp.328-338
    • /
    • 1994
  • Background: Effect of sulfur dioxide($SO_2$) exposure on airway is well known but little about the effect of $SO_2$ exposure on lung parenchyme. This study is to determine if short tenn exposure to $SO_2$ in concentration commonly found in industrialized environment cause potentially harmful effect on the lung parenchyme, and to evaluate the exposure time-response relationship between short tenn exposure to $SO_2$ and the inflammatory response in mouse lung. Method: 5ppm $SO_2$ gas was used and 48 mice were grouped into control(10), 30(9), 60(11), and 120 minute exposure(18) group. In each group, bronchoalveolar lavage(BAL) was done immediately after and at 1,2,3 days after exposure. Histological examination was performed in control and 120 minute exposure group. Results: 1) Cell response in bronchoalveolar lavage fluid. In 30 and 60 minute exposure group, compared to the control group, lymphocyte count has significantly increased(p<0.05) at 1 day after exposure but did not differ at 2 days after exposure. In 120 minute exposure group, also compared to the control group, there was significant increase in total cell, macrophage, and lymphocyte count at 1 day after exposure, (p<0.05) which lasted for 2 days but did not significantly differ at 3 days after exposure. 2) Histological findings in 120 minute exposure group. In the airway, mild epithelial cell damage and ciliary loss were noted but there was no evidence of inflammatory cell infiltration. Interstitial inflammatory infiltration was noted at 1 day after exposure, which lasted for 3 days after exposure and there was no evidence of edema or fibrosis in the interstitium Conclusions: These data indicate potentially noxious effect of $SO_2$ on the lung parenchyme as well as the airway at exposure level that are regarded as relatively safe, and the duration of injury depends on the exposure time.

  • PDF

The Clinical Effects of Leukocyte-Depleting Filter on Cardiopulmonary Bypass (체외순환 시 백혈구 제거필터 사용의 임상효과)

  • 박경택;최석철;최국렬;정석목;최강주
    • Journal of Chest Surgery
    • /
    • v.34 no.6
    • /
    • pp.454-464
    • /
    • 2001
  • Background: It has been recognized that systemic inflammatory reaction and oxygen free radical formed by activated leukocyte in the procedure of cardiopulmonary bypass(CPB) frequently produce postoperative cardiac and pulmonary dysfunction. The purpose of this study was to evaluate the efficacy of leukocyte-depleting filters in the cardiopulmonary bypass circuit for patients undergoing open heart surgery(OHS). Material and method: The study involved 15 patients who underwent OHS with a Leukoguard-6 leukocyte filter placed in the arterial limbs of the bypass circuit(filter group, n=15) and 15 patients who did not have the filter(control group, n=15). We analyzed the differences between the groups in intraoperative changes of peripheral blood leukocyte and platelet counts, pre- and postbypass changes of malondialdehyde(MDA), troponin-T(TnT), 5'-nucleotidase(5'-NT) in coronary sinus blood, spontaneous recovery rate of heart beat after CPB, pre-and postoperative cardiac index(Cl) and pulmonary vascular resistance(PVR), and the amounts of postoperative bleeding and sternal wound complication. Result: During CPB, total leukocyte count of the filter group(9,567$\pm$ 842/㎣) was significantly less than that of the control group(13,573+1,167/㎣) (p<0.01), but there was no significant difference in platelet count between the groups. Postoperative levels of MDA(3.78+0.32 $\mu$mol/L vs 5.86+0.65 $\mu$mo1/L, p<0.01), TnT(0.40$\pm$0.04 ng/mL vs 0.59$\pm$0.08 ng/mL, p<0.05) and 5'-NT(3.88$\pm$0.61 U/L vs 5.80$\pm$0.90 U/L, p<0.05) were all significantly lower in the filter group than the control group. Postoperative Cl was higher in the filter group than the control group(3.26$\pm$0.18 L/$m^2$min vs 2.75$\pm$0.17 L/$m^2$/min, p=0.05). PVR of the filter group was lower than that of the control group(65.87$\pm$7.59 dyne/sec/cm$^{5}$ vs 110.80+12.22 dyne/sec/cm$^{5}$ , p<0.01). Spontaneous recovery rate of heart beat in the filter group was higher than that in the control group(12 patients vs 8 patients, p<0.05). Postoperative wound infection occurred in one case in the filter group and 4 case in the control group(p<0.05). Postoperative 24 hour blood loss of the filter group was more than that of the control group (614$\pm$107 mL vs 380+71 mL, p=0.05).

  • PDF

Radiation Absorbed Dose Measurement after I-131 Metaiodobenzylguanidine Treatment in a patient with Pheochromycytoma (갈색세포종 환자에서 Medical Internal Radiation Dose법을 이용한 I-131 Metaiodobenzylguanidine 치료 후 흡수선량 평가)

  • Yang, Weon-Il;Kim, Byeung-Il;Lee, Jae-Sung;Lee, Jung-Rim;Choi, Chang-Woon;Lim, Sang-Moo;Hong, Sung-Woon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.422-429
    • /
    • 1999
  • Purpose: The measurement of radiation absorbed dose is useful to predict the response after I-131 labeled metaiodobenzylguanidine (MIBG) therapy and determine therapy dose in patients with unresectable or malignant pheochromocytoma. We estimated the absorbed dose in tumor tissue after high dose I-131 MIBG in a patient with pheochromocytoma using a gamma camera and Medical Internal Radiation Dose (MIRD) formula. Materials and Methods: A 64-year old female patient with pheochromocytoma who had multiple metastases of mediastinum, right kidney and periaortic lymph nodes, received 74 GBq (200 mCi) of I-131 MIBG. We obtained anterior and posterior images at 0.5, 16, 24, 64 and 145 hours after treatment. Two standard sources of 37 and 74 MBq of I-131 were imaged simultaneously. Cummulated I-131 MIBG uptake in tumor tissue was calculated after the correction of background activity, attenuation, system sensitivity and count loss at a high count rate. Results: The calculated absorbed radiation dose was 32-63 Gy/ 74 GBq, which was lower than the known dose for tumor remission (150-200 Gy). follow-up studies at 1 month showed minimally reduced tumor size on computed tomography, and mildly reduced I-131 MIBG uptake. Conclusion: We estimated radiation absorbed dose after therapeutic I-131 MIBG using a gamma camera and MIRD formula, which can be peformed in a clinical nuclear medicine laboratory. Our results suggest that the measurement of radiation absorbed dose in I-131 MIBG therapy is feasible as a routine clinical practice that can guide further treatment plan. The accuracy of dose measurement and correlation with clinical outcome should be evaluated further.

  • PDF

Prospective Observation Study on Hyperthyroidism Patients Treated with Korean Medicine (한의치료를 받은 갑상선 기능 항진증 환자에 대한 전향적 관찰연구)

  • Choi, Yu-jin;Shin, Seon-mi;Han, Yang-hee;Ahn, Se-young;Cho, Chung-sik
    • The Journal of Internal Korean Medicine
    • /
    • v.39 no.1
    • /
    • pp.84-96
    • /
    • 2018
  • Objective: This is aprospective clinical case study that includes the administration of Ahnjeonbaekho-tang (AJBHT) to patients who have suffered from Graves' disease for the 8 weeks of the clinical research. Methods: Without administration of an antithyroid drug, AJBHT was administered 3 times a day for 8 weeks. In Case 1, AJBHT without modification was administered and in Case 2, in accordance with the patients' symptoms, a dose of Gypsum Fibrosum was increased by 4g from the beginning of week 2, and further increased by 16 g, for a total of 20 g between week 6 and week 8. Body mass index (BMI), thyroid function test (TFT), thyroid autoantibody test, complete blood cell count (CBC), and blood chemistry (BC) tests were conducted at an interval of 4 weeks, for a total of 3 times during the study. The clinical manifestations, a spectrum of symptoms of the patients, was observed by Wayne's Index, Euro-QOL-5 Dimension (EQ-5D), and Perceived Stress Scale (PSS). Results: In both cases, an acceptable significance of reduction of value in T3, fT4, Thyroid stimulating antibody (TSAb) and Thyroid stimulating hormone receptor antibody (TSH-R-Ab) was observed. After treatment, in TFT, T3 decreased by 31.66%, fT4 decreased by 32.82% in Case 1, and T3 decreased by 43.42%, and fT4 decreased by 37.32% in Case 2. In the thyroid autoantibody test, TSAb decreased by 7.59%, and TSH-R-Ab decreased by 53.19% in Case 1, and TSAb decreased by 33.45%, TSH-R-Ab decreased by at least 7.75% in Case 2. Besides this, there was a decreasing trend of Wayne's index, and a loss of typical symptoms of hyperthyroidism also declared the efficacy. Conclusion: From these results, AJBHT is very effective in the regulation of TFT and improving the symptoms of hyperthyroidism, and is also expected to be an effective alternative to antithyroid drugs for patients who have side effects or drug intolerance.