Effect of ERP Implementation for Public Owner - Based on Case Study (공공발주기관의 ERP 적용효과 평가방안 - 사례연구중심으로)

  • Kim, Hyoun Young;Park, Hee-Sung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.2
    • /
    • pp.749-755
    • /
    • 2013
  • The public corporations have already implemented ERP to improve productivity, quality, and cost saving. This paper presents the result of business process improvement based on implementation of ERP. Therefore, this paper performed case study of K corporation. Survey was conducted to define the degree of improvement and evaluation method was presented using AHP. The weights for each business area is assigned based on AHP. Then ERP is evaluated in efficiency, work transparency, information sharability, and easy of use. It is meaningful achievement considering its short term implementation. The human resource management shows a relatively larger improvement than other management processes. However, information sharability shows relatively low improvement than others. This quantified result of user-oriented subjective evaluation on ERP implementation will contribute to evaluate the impact of ERP for owner organizations.

Influences of the Surface Pollution Cause by the Marine Growth on Ship Hulls on Engine Performance and Output (선체 해양생물의 선저오염이 엔진성능과 출력에 미치는 영향)

  • Jung, Kyun-Sik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.399-404
    • /
    • 2015
  • The cost of fuel in ships has recently increased due to a rapid increase in international oil prices and international restrictions regarding the greenhouse effect generated from the burning of fuel. Therefore, different methods for changing the hull designs for improving energy efficiency, developing coating for reducing friction resistances, developing additives for improving engine thermal efficiency, and low-speed operation for reducing fuel consumption have been considered. The developments of high-speed, large-scale, and energy-saving vessels are deemed essential to adapt to the recent high oil price era. Therefore, it is important to analyze Precisely the qualitative and quantitative changes in the resistance value of the local areas of the hull surface. In this study, the engine performance before and after docking was analyzed to examine friction resistance caused by marine growth on the hull as a basic study for improving the energy efficiency. The result was then presented by comparing it with the previous data for 2.5 years between docks to investigate the performance of the main engine, the change in friction resistances and loads, the fuel consumption and ship speed.

Reuse of Exhaust Heat and Improvement in Fuel Efficiency of Grain Dryer (곡물(穀物) 건조기(乾燥機)의 배기열(排気熱) 재이용(再利用) 및 열효율(熱効率) 개선(改善)에 관(關)한 연구(硏究))

  • Keum, Dong Hyuk;Lee, Yong Kook;Lee, Kyou Seung;Han, Jong Ho
    • Journal of Biosystems Engineering
    • /
    • v.9 no.2
    • /
    • pp.65-73
    • /
    • 1984
  • While most of researches on the performance of high temperature grain dryer have dealt mainly with improving dryer capacity and drying speed during the last twenty years, energy efficiency, in fact, has not been emphasized. Current fuel supplies and energy cost have shifted the emphasis to reducing the energy consumption for grain drying while maintaining dryer capacity and grain quality. Since the energy input for drying is relatively large, the recovery and reuse of at least part of the exhaust energy can significantly reduce the total energy consumption in existing drying systems. Unilization of exhaust heat in grain dryer either through direct recycling or by a thermal coupling in heat exchanger have been subject of a number of investigators. However, very seldom research in Korea has been done in this area. Three drying tests(non-recycling, 0.22 recycle ratio, and 0.76 recycle ratio)were performed to investigate the thermal efficiency and heat loss factors of continuous flow type dryer, and to analyze the effect of recycle ratio (weight of exhaust air recycled/total weight of input air) on the energy requriements for rough rice drying. The test results showed that when the exhaust air was not recycled, the energy lost from furnace was 15.3 percent of input fuel energy, and latent and sensible heat of exhaust air were 61.4 percent and 11.2 percent respectively. The heat which was required in raising grain temperature and stored in dryer was relatively small. As the recycle ratio of exhaust air was increased, the drying rate was suddenly decreased, and thermal efficiency of the kerosene burner was also decreased. Drying test with 0.76 recycle ratio resulted in 12.4% increase in fuel consumption, and 38.4% increase in electric power consumption as compared to the non-recycled drying test. Drying test of 0.22 recycle ratio resulted in 6.8% saving in total energy consumption, 8.0% reduction in fuel consumption, and 2.5% increase in electric power consumption as compared to the non-recycled drying test.

  • PDF

A Study on the Precautions Effects of the Enclosure Integrity Test for the Gaseous Extinguishing Systems: Focusing on the Power Plant (가스계 소화설비의 밀폐도 시험에 영향을 미치는 사전조치에 관한 연구: 발전소를 중심으로)

  • Kim, Young-Chul;Jo, Il-Hyun;Lee, Su-Kyung
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.60-66
    • /
    • 2015
  • The present study was aimed to analyze enclosure integrity test, which is the performance experiment of soaking time, in a fire zone equipped with gaseous extinguishing system in an effort to find understand the effect of precaution factors upon the success of fire extinguishment. To achieve the goal of this study, it divided the fire zones of internal and external power plants into ones taking precaution measures and not taking them and then enclosure integrity test was given respectively. Therefore, this study examined the success rate if the test according to the presence and absence of the precaution measure and confirmed the failure factors, designed concentration soaking time and proportion of leakage area to total volume area by type of gaseous extinguishing system and rooms. Precaution measures were applied to the fire zones without them to confirm the increase of the success rate of enclosure integrity test. By doing so, it was found that reduced number of experiments caused by failure led to cost saving.

A Two-Demensional Nonlinear Analysis of Precast Segmental PSC-I Girder with Dry Joint (건식접합부를 갖는 프리캐스트 세그먼트 PSC-I형 거더의 2차원 비선형해석)

  • Kim, Kwang-Soo;Kim, Tae-Wan;Park, Jun-Myung;Park, Sun-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.5
    • /
    • pp.99-106
    • /
    • 2007
  • To satisfy with the increased requirements of cost reduction, labor saving, and rapid construction, the purpose of this study is to investigate the structural behavior of PSC monolithic and spliced girders. Three tests were conducted on small-scale girder specimens. This paper presents the result of experimental studies in terms of the load-deflection behavior. Different joint type and tendon amount were investigated as major variables. The monolithic girder was arranged with three tendons. The spliced girder consisted of five segments connected by three tendons. In addition, five-segmented girders connected by more than three tendons were built to examine the effect of the tendon amount. The experimental results show the difference of behavior between monolithic and spliced girders. Moreover, nonlinear finite element method analysis was utilized to verify the experimental result.

Experimental study on seismic behavior of reinforced concrete column retrofitted with prestressed steel strips

  • Zhang, Bo;Yang, Yong;Wei, Yuan-feng;Liu, Ru-yue;Ding, Chu;Zhang, Ke-qiang
    • Structural Engineering and Mechanics
    • /
    • v.55 no.6
    • /
    • pp.1139-1155
    • /
    • 2015
  • In this study, a new retrofitting method for improving the seismic performance of reinforced concrete column was presented, in which prestressed steel strips were utilized as retrofitting stuff to confine the reinforced concrete column transversely. In order to figure out the seismic performance of concrete column specimen retrofitted by such prestressed steel strips methods, a series of quasi-static tests of five retrofitted specimens and two unconfined column specimen which acted as control specimens were conducted. Based on the test results, the seismic performance including the failure modes, hysteresis performance, ductility performance, energy dissipation and stiffness degradation of all these specimens were fully investigated and analyzed. And furthermore the influences of some key parameters such as the axial force ratios, shear span ratios and steel strips spacing on seismic performance of those retrofitted reinforced concrete column specimens were also studied. It was shown that the prestressed steel strips provided large transverse confining effect on reinforced concrete column specimens, which resulted in improving the shearing bearing capacity, ductility performance, deformation capacity and energy dissipation performance of retrofitted specimens effectively. In comparison to the specimen which was retrofitted by the carbon fiber reinforced plastics (CFRP) strips method, the seismic performance of the specimens retrofitted by the prestressed steel strips was a bit better, and with much less cost both in material and labor. From this research results, it can be concluded that this new retrofitting method is really useful and has significant advantages both in saving money and time over some other retrofitting methods.

Development of Analysis Model of Pressure·Flow-controlled Swash Plate Type Pump for Evaluating Feasibility of Design (설계 타당성 검토를 위한 압력·유량 제어형 사판식 피스톤 펌프의 해석모델 개발)

  • Lee, Geun-Ho;Noh, Dae-Kyung;Park, Sung-Su;Lee, Dae-Hee;Jin, Jung-Man;Jang, Joo-Sup
    • Journal of the Korea Society for Simulation
    • /
    • v.25 no.4
    • /
    • pp.53-63
    • /
    • 2016
  • This study aims to verify the feasibility of design by developing pressure flow-controlled swash plate type pump with the use of SimulationX, a computer analysis program. Developing analysis model based on design drawing data has a cost-saving effect because it is possible to figure out the effectiveness of design through the work and it never falls into repeated inaccuracies in the production process. Analysis model is developed in the following order. First, the structure of each part such as valve and rotating unit which have dynamic factor is analyzed and the modeling of single component is carried out, reflecting drawing data. Second, the modeling of pump assembly is carried out with the combination of each analysis model and a work is conducted to determine whether the modeling can perform pressure flow control function according to load condition smoothly based on design intent. At the end of the modeling process, the feasibility of design is verified by showing the parts which are moving as expected mechanism.

A Study on Public Enterprise Workers with Wage Peak System -Population, Economic and Organizational Aspects- (인구·경제·조직 측면에서 공기업 임금피크 근로자 분석)

  • Youn, Jae-Hee;Lee, Su-Gyeong
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.1
    • /
    • pp.174-186
    • /
    • 2019
  • This study was designed to examine the demographic, economic and organizational characteristics of wage peak workers in public enterprises and their relationship between wage peak system and retirement, which is faster than other areas where the number of elderly workers is growing. The study targets 211 wage peak workers in 19 public enterprises engaged in the wage peak system, considering the level of aging and the size of wage peak workers. According to the demographic and economic characteristics, the results of the study showed that the education level, household income, post retirement cost, retirement saving and investment amount had an effect on wage peak satisfaction, wage peak acceptance, retirement preparation and retirement attitude. Next, aspects of organizational characteristics, there were differences according to position, job title, working period, remaining retirement age, participation in retirement preparation program and wage peak application. Based on these findings, effective wage peak system for the aged society was required to discuss the need for follow-up research by job group, position rank, economic level, and educational level of aged people such as welfare, education and former support.

Environmental Assessment of Smart Grid Station Project Centered on Pilot Project of Korea Electric Power Corporation Building

  • Park, Sun-Kyoung;Son, Sung-Yong;Kim, Dongwook;Kim, Buhm-Kyu
    • Journal of Climate Change Research
    • /
    • v.7 no.3
    • /
    • pp.217-229
    • /
    • 2016
  • Increased evidences reveal that the global climate change adversely affect on the environment. Smart grid system is one of the ways to reduce greenhouse gas emissions in the electricity generation sector. Since 2013, Korea Electric Power Corporation (KEPCO) has installed smart grid station in KEPCO office buildings. The goal of this paper is two folds. One is to quantify the reduction in greenhouse gas emissions through smart grid stations installed in KEPCO office buildings as a part of pilot project. Among components of smart grid stations, this research focused on the photovoltaic power system (PV) and energy storage system (ESS). The other is to estimate the reduction in greenhouse gas emissions when PV is applied on individual houses. Results show that greenhouse gas emissions reduce 5.8~11.3% of the emissions generated through the electricity usage after PV is applied in KEPCO office buildings. The greenhouse gas emissions reduction from ESS is not apparent. When PV of 200~500 W is installed in individual houses, annual greenhouse gas emission reduction in 2016 is expected to be approximately $2.2{\sim}5.4million\;tCO_2-eq$, equivalent to 6~15% of greenhouse gas emissions through the electricity usage in the house hold sector. The saving of annual electricity cost in the individual house through PV of 200 W and 500 W is expected to be 47~179 thous and KRW and 123~451 thousand KRW, respectively. Results analyzed in this study show the environmental effect of the smart grid station. In addition, the results can be further used as guidance in implementing similar projects.

Application of Chemical Dust Suppressants for Control of Fugitive Dust in Ash pond of Thermal Power Plant (화력발전소의 회처리장 내 비산먼지 저감을 위한 화학적 먼지억제제 적용 연구)

  • Choi, Yu-Lim;Choi, Jong-Soo;Yang, Jae-Kyu;Park, Sun-Hwan;Joo, Hyun Soo;Chang, Yoon-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.23 no.6
    • /
    • pp.82-89
    • /
    • 2018
  • The objective of this study is to evaluate efficiencies of chemical suppressants for control of fugitive dust in ash pond of thermal power plant. In this study, $MgCl_2$, PAM (polyacrylamide), and PVA (poly vinyl alcohol) that are generally applied to suppression of fugitive dust generated from unpaved road, coal mining, storage piles and etc, were employed as chemical dust suppressants. The coal ash (coal combustion residuals) were sampled from the ash pond of Yeongheung power division in Incheon, South Korea. The characterization of the sample including particle size distribution, pH, $pH_{PZC}$ and pore volume as well as XRF analysis were carried out. The suppressant treated-samples were investigated with the wind tunnel experiments to estimate and compare the effect of suppressants on stabilization of the surface of coal ash samples. According to the results, the stability of suppressant-treated samples were significantly improved compared to water-treated samples. Among the three kinds of suppressants, PAM and PVA showed higher efficiencies and cost saving than $MgCl_2$.