• 제목/요약/키워드: Cost of energy

검색결과 4,591건 처리시간 0.032초

확률계획법을 활용한 원자력 대체비용의 분석 (Analysis on the Replacement Cost of Nuclear Energy Using a Stochastic Programming Model)

  • 정재우;민대기
    • 경영과학
    • /
    • 제30권1호
    • /
    • pp.139-148
    • /
    • 2013
  • A nuclear energy has been one of the most important sources to securely supply electricity in South Korea. Its weight in the national electricity supply has kept increasing since the first nuclear reactor was built in 1978. The country relies on the nuclear approximately 31.4% in 2012 and it is expected to increase to 48.5% in 2024 based on the long-term electricity supply plan announced by the Korean government. However, Fukushima disaster due to 9.0 magnitude earthquake followed by the tsunami has raised deep concerns on the security of the nuclear power plants. The policy makers of the country are much interested in analyzing the cost structure of the power supply in the case that the nuclear is diminished from the current supply portion. This research uses a stochastic model that aims to evaluate the long-term power supply plan and provides an extensive cost analysis on the changes of the nuclear power supply. To evaluate a power supply plan, the research develops a few plausible energy mix scenarios by changing the installed capacities of energy sources from the long-term electricity supply plan. The analyses show that the nuclear is still the most attractive energy source since its fuel cost is very much stable compared to the other sources. Also the results demonstrate that a large amount of financial expenditure is additionally required every year if Koreans agree on the reduction of nuclear to increase national security against a nuclear disaster.

Reduce on the Cost of Photovoltaic Power Generation for Polycrystalline Silicon Solar Cells by Double Printing of Ag/Cu Front Contact Layer

  • Peng, Zhuoyin;Liu, Zhou;Chen, Jianlin;Liao, Lida;Chen, Jian;Li, Cong;Li, Wei
    • Electronic Materials Letters
    • /
    • 제14권6호
    • /
    • pp.718-724
    • /
    • 2018
  • With the development of photovoltaic industry, the cost of photovoltaic power generation has become the significant issue. And the metallization process has decided the cost of original materials and photovoltaic efficiency of the solar cells. Nowadays, double printing process has been introduced instead of one-step printing process for front contact of polycrystalline silicon solar cells, which can effectively improve the photovoltaic conversion efficiency of silicon solar cells. Here, the relative cheap Cu paste has replaced the expensive Ag paste to form Ag/Cu composite front contact of silicon solar cells. The photovoltaic performance and the cost of photovoltaic power generation have been investigated. With the optimization on structure and height of Cu finger layer for Ag/Cu composite double-printed front contact, the silicon solar cells have exhibited a photovoltaic conversion efficiency of 18.41%, which has reduced 3.42 cent per Watt for the cost of photovoltaic power generation.

미래형 대형풍력발전기 개발 추세 (Europe 지역의 Case Study)

  • 오철수
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1998년도 춘계 학술발표회 논문집
    • /
    • pp.271-277
    • /
    • 1998
  • 1. Why Wind Power\ulcorner Advantages of Wind Energy : free cost, non-pollutant, free waste large unit is possible Disadvantages : intermittent of energy density limited sites Unit Capacity of various Power Plant Solar PP : 10 - 500㎾ Wind PP : 200 - 2000 ㎾ Nuclear PP 700 - 1000 MW Installation Cost of Power Plants Nuclear PP : $ 2,500/㎾ Solar PP : $ 6,000/㎾ Wind PP : $ 1.000 /kw.

  • PDF

ASSESSMENT OF THE COST OF UNDERGROUND FACILITIES OF A HIGH-LEVEL WASTE REPOSITORY IN KOREA

  • Kim, Sung-Ki;Choi, Jong-Won
    • Nuclear Engineering and Technology
    • /
    • 제38권6호
    • /
    • pp.561-574
    • /
    • 2006
  • This study presents the results of an economic analysis for a comparison of the single layer and double layer alternatives with respect to a HLW-repository. According to a cost analysis undertaken in the Korean case, the single layer option was the most economical alternative. The disposal unit cost was estimated to be 222 EUR/kgU. In order to estimate such a disposal cost, an estimation process was sought after the cost objects, cost drivers and economic indicators were taken into consideration. The disposal cost of spent fuel differs greatly from general product costs in the cost structure. Product costs consist of direct material costs and direct labor and manufacturing overhead costs, whereas the disposal cost is comprised of construction costs, operating costs and closure costs. In addition, the closure cost is required after a certain period of time elapses following the building of a repository.

PSO를 이용한 물 재이용 펌프시스템의 에너지 비용 제어 (Energy Cost Saving Control of Water Reuse Pumping System Using Particle Swarm Optimization)

  • 부창진;김호찬;강민제
    • 한국산학기술학회논문지
    • /
    • 제16권1호
    • /
    • pp.860-867
    • /
    • 2015
  • 본 논문은 PSO 알고리즘을 이용하여 물 재이용 펌프 시스템의 에너지비용을 최소화 할 수 있는 방법을 제안한다. 1시간 단위의 시간대에서 펌프제어를 위해 계시별 요금제를 기반으로 하여 최적화 구간을 설정하고 PSO알고리즘을 이용하여 에너지 비용을 절감할 수 있도록 펌프동작을 제어한다. 물 재이용 펌프시스템에서 고정된 유량을 출력하는 펌프와 입력전력을 가변할 수 있는 펌프에 대해 TOU 기반에서 에너지 비용을 최대로 줄일 수 있도록 시스템을 동작시킨다. 시뮬레이션을 통해 제안한 에너지 비용 절감 방법이 기존 수위기반의 제어방법보다 비용을 절감할 수 있음을 확인할 수 있다.

대체에너지기술의 환경비용 고찰

  • 김부호
    • 태양에너지
    • /
    • 제13권2_3호
    • /
    • pp.151-156
    • /
    • 1993
  • The comparison of solar energy technologies with conventional technologies involves more than just comparing the costs of supplying energy and provding capacity. Solar technologies supply energy in a sustainable manner while having minimal effects on the environment. When choosing between solar energy technologies and conventional technologies, first cost is a important factor. The environmental and other social benifits of using solar energy technologies contrasts sharply with the environmental degradation and social costs resulting from the use of conventional technologies. These hidden costs, sometimes called "social cost", are not included in conventional economics. This paper is emphasized that the consideration of social costs effects comparisons between renewable and conventional energy technologies is of importance.

  • PDF

신뢰도 비용을 고려한 송전요금 할당 (Transmission Cost Allocation Considering Reliability Cost)

  • 박영현;김동민;김진오
    • 전기학회논문지
    • /
    • 제57권4호
    • /
    • pp.576-581
    • /
    • 2008
  • Electricity Market in Korea can't provide locational price signal through energy price because energy market is CBP(Cost Based Pool) using uniform price. Generators don't want to locate in a densely populated load area(like the metropolitan area). Because they are paid more fixed cost in metropolitan area. This situation has loss and congestion occurred in power system. However energy market without price signal can't lead generator to the metropolitan. So, market participants should be provided price signal through the transmission price instead of energy price. This paper proposes transmission pricing method considering reliability cost in order to offer price signal. Also, it proposes the method to allocate the transmission cost to each transmission line user through a fair and a reasonable manner. The transmission price is decided by the reliability value of each line. If a transmission line of high reliability value is broke, users using that line will get a loss and a discomfort. So, it is fair that users using a transmission line of high reliability value pay more than the other users. Also, it is reasonable that a transmission line owner get paid more form users using that line.

Assessment of Reliability in the Distribution System of an Industrial Complex

  • Choi, Sang-Bong
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권2호
    • /
    • pp.201-207
    • /
    • 2007
  • As the power industry moves towards open competition, there has been a need for methodology to evaluate distribution power system reliability by using customer interruption costs, particularly in power supply zones under the competitive electricity market. This paper presents an algorithm to evaluate system average interruption duration index, expected energy not supplied, and system outage cost taking into consideration failure rate of the distribution facility and industrial customer interruption cost. Also, to apply this algorithm to evaluate system outage cost presented in this paper, the distribution arrangement of a dual supply system consisting of mostly high voltage customers in an industrial complex in Korea is used as a sample case study. Finally, evaluation results of system interruption cost, system average interruption duration index, and expected energy not supplied in the sample industrial complex area are shown in detail.

복합열병합 발전에 대한 전기 및 열 원가산정 (Cost Accounting of Electricity and Heat on Combined Cycle Cogeneration)

  • 김덕진;이근휘
    • 설비공학논문집
    • /
    • 제16권7호
    • /
    • pp.673-682
    • /
    • 2004
  • The cost accounting of products on energy system is important for evaluating the economical efficiency and deciding the reasonable sale price. In the present, the suggested OECOPC method was applied to a combined cycle cogeneration, and each unit cost of electricity and heat products was calculated. In addition, the previous thermoeconomic methods were applied and calculated to equal system. As a result of comparing various methods, the unit costs by OECOPC method were calculated in the middle value of those. This result tells that OECOPC methods are most moderate. The suggested OECOPC method can apply any energy system. Hence this method is expected to make contribution to cost accounting on energy System.

거시적인 접근방법을 통한 공급지장비 추정에 관한 연구 (A Study on the Outage Cost Assessment by using Macro Approach)

  • 박영신;전동훈;박정제;오태곤;조경희;최재석
    • 전기학회논문지
    • /
    • 제59권10호
    • /
    • pp.1703-1711
    • /
    • 2010
  • Electric power utilities are facing increasing uncertainties regarding the economic, political, societal, environmental constraints under they operate and plan their future systems. The utilities have to integrate consumers' interruption cost representing reliability worth of electricity into the process of determining the optimum investment level. In order to do so, the estimated outage cost must be included into quantitative index corresponding to system capital and operation investment cost to establish an optimal expansion plan. This paper is a study on the outage cost assessment by using macro approach for calculating IEAR(Interrupted Energy Assessment Rates) and the TRELSS(Transmission Reliability Evaluation for Large-Scale Systems) program was used to calculate EENS(Expected Energy Not Served).