• Title/Summary/Keyword: Corrosion protection

Search Result 562, Processing Time 0.029 seconds

Evaluation of High Temperature Particle Erosion Resistance of Vanadium-Boride Coating (Vanadium-Boride코팅의 고온 내입자침식성 평가)

  • Lee, E.Y.;Kim, J.H.;Jeong, S.I.;Lee, S.H.;Eum, G.W.
    • Corrosion Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.76-84
    • /
    • 2015
  • The components in ultra super critical (USC) steam turbine, which is under development for high efficient power generation, are encountering harsher solid particle erosion by iron oxide scales than ones in the existing steam turbines. Therefore, the currently used boride coating will not be able to hold effective protection from particle erosion in USC system and should be replaced by new particle erosion resistant coatings. One of the best protective coatings developed for USC steam turbine parts was found to be vanadium-boride (V-boride) coating which has a hardness of about 3000 HV, much higher than that of boride, 1600~2000 HV. In order to evaluate particle erosion resistance of the various coatings such as V-boride, boride and Cr-carbide coatings at high temperature, particle erosion test equipments were designed and manufactured. In addition, erosion particle velocity was simulated using FLUENT software based on semi-implicity method for pressure linked equations revised (SIMPLER). Based on experimental results of this work, the vanadium-boride coating was found to be superior to others and to be a candidate coating to replace the boride coating.

A Study on the System Integrity of Gas Pipeline by High Voltage Power Line in Submarine Tunnel (절점망 해석프로그램을 이용한 해저터널 내 고전압 전력케이블에 의한 가스배관의 안전성 평가 연구)

  • Bae Jeong-Hyo,;Ha Tae-Hyun,;Lee Hyun-Goo,;Kim Dae-Kyeong,
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.4 s.16
    • /
    • pp.21-26
    • /
    • 2001
  • Because of the continuous growth of energy consumption, and also tile tendency to site power lines and pipelines along the same routes, the close proximity of high voltage structures and metallic pipelines has become more and more frequent. Recently, the results of assessment about a system integrity are needed in korea also when a gas pipeline is running parallel with high voltage power line in same submarine tunnel, Therefore, we analyze the system integrity(AC corrosion of pipe, melting of pipeline coating, safety of insulation flange, especially cathodic protection system which are rectifier and CI(cathodic Isolator)) resulting from the influence of high voltage power system.

  • PDF

Effects of Polyurethane Coatings on 304 Stainless Steel Formed by Thermoset for Safety Management of Industrial Disaster (산업 재해의 안전관리를 위한 열경화에 의한 304 스테인레스 스틸에 대한 폴리우레탄 도료의 영향)

  • Kim, Ki-Jun;Lee, Joo-Youb
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.317-322
    • /
    • 2012
  • The microstructures were examined by SEM, FT-IR spectra, tensible properties mole % of [NCO/OH], and particle size analyzer. Growing concerns in the environment-friendly industries have led to the development of solvent-free formulations that can be cured. We had synthesized the polyurethane resin having the ability to protect stainless steel against corrosion. Compared with general packing materials and coatings, this resin is highly stronger in intensity and longer durability. Polyurethane resins were composed of polyols, IPDI, silicone surfactant, catalyst and crosslink agent. Moreover, thermal fillers such as $Al_2O_3$, fume silica and $ZrO_2$ not only accelerated the curing rate but also improved the physical property as thermal barriers. The rigid segments of polyurethane in mechanical properties were due to crosslink agent and the increase of [NCO/OH]. In conclusion, the polyurethane microstructure with crosslink agent can be good material for themoset coating of metal substrates such as stainless steel.

A Study on the High Performance Waterborne Epoxy Resin for Surface Coating (표면 코팅을 위한 고성능 수용성 에폭시 수지에 관한 연구)

  • Kim, Yong-Ho;Lee, Kwang-Won;Kim, Young-Jae
    • Elastomers and Composites
    • /
    • v.35 no.2
    • /
    • pp.89-97
    • /
    • 2000
  • Waterborne epoxy resins have been developed in order to meet environmental regulations for reduction of the emission of organic solvents from coating industry As each generation has filled a performance gap in the previous technology, new waterborne epoxy resin has developed. Initially, waterborne epoxy resins were used primarily on masonry, but the subsequent generations have found utility for the protection of metallic substrates as well. Indeed, the third generation systems have been formulated to produce the high performance industrial maintenance primers which possess the desirable combination of good corrosion resistance and low volatile organic compound levels. This paper outlines the important guidelines for formulating waterborne epoxy primers from waterborne epoxy resin that has recently developed in our company. The importance of using the appropriate resin-curing agent system at the optimized epoxy to amine ratio is stressed.

  • PDF

Performance Evaluation of Antioxidizing Device for Protection of Car Body (자동차 차체 보호를 위한 산화방지 장치의 성능 평가)

  • Kim, Hae Sik;Yun, Yeong Jin;Ji, Jong Gi
    • Journal of the Korean Chemical Society
    • /
    • v.46 no.5
    • /
    • pp.444-456
    • /
    • 2002
  • To protect the occurrence of the oxidation of car body, we developed antioxidizing device made with sacrificial anode. Because car body is made of iron and iron-alloy and oxidation potential of Mg, Al and Zn is higher than that of iron, sacrificial anodes were made with Mg, Al and Zn. Accordingly, Mg, Al and Zn are better oxidizing than car body, iron and iron-alloy can be protected from oxidizing. We have made an antioxidizing device and evaluated their anti-corrosive effect for iron piece in the solution of hydrochloric, nitric and sulfuric acid using balance, SEM and XPS. When iron pieces were connected with antioxidizing device of car body, weight loss by oxidation was remarkably reduced and surface corrosion of iron piece was protected. It was shown that the surface of iron pieces which is not con-nected to the device was changed to iron(Ⅲ) oxide, Fe$_2$O$_3$. Therefore, if this device is attached to car body, corrosion and oxidation of car body will be reduced, considerably.

Analysis of Induced Voltage on the Gas Pipeline at the Fault in a Underground Power Cables (지중전력케이블에서 고장발생시 인근 가스배관에 유도되는 전압 해석)

  • Bae J. H.;Kim D. K.;Kim K. J.
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.3 s.11
    • /
    • pp.26-32
    • /
    • 2000
  • Because of the continuous growth of energy consumption, and also the tendency to site power lines and pipelines along the same routes, the close proximity of high voltage structures and metallic pipelines has become more and more frequent. Moreover, normal steady state and fault currents become higher as electric networks increase in size and power Therefore, there has been and still is a growing concern(safety of people marking contact with pipeline, risk of damage to the pipeline coating, the metal and equipment connected to pipeline, especially cathodic protection system) about possible hazards resulting from the influence of high voltage power system on metallic structures(gas pipeline, oil pipeline and water pipeline etc.). Therefore, we analyze the interference problems when the gas pipeline is buried with power cable in the same submarine tunnel. This paper present the results of the study about interference mechanism, AC corrosion limitation of safety voltage and analysis of induction voltage.

  • PDF

Effectiveness study of a cement mortar coating based on dune sand on the carbonation of concrete

  • Korichi, Youssef;Merah, Ahmed;Khenfer, Med Mouldi;Krobba, Benharzallah
    • Advances in concrete construction
    • /
    • v.13 no.4
    • /
    • pp.315-325
    • /
    • 2022
  • Reinforced concrete structures are exposed throughout their lifetime to the phenomenon of carbonation, which considerably influences their durability by causing corrosion of the reinforcements. The fight against this phenomenon is usually ensured by anti-carbonation coatings which have the possibility of limiting the permeability to carbon dioxide or with coatings which absorb the CO2 present in the air. A coating with good crack-bridging (sealing) capacity will prevent water from entering through existing cracks in concrete. Despite the beneficial effect of these coatings, their durability decreases considerably over time with temperature and humidity. In order to use coatings made from local materials, not presenting any danger, available in abundance in our country, very economical and easy to operate is the main objective of this work. This paper aim is to contribute to the formulation of a corrected dune sand-based mortar as an anti-carbonation coating for concrete. The results obtained show that the cement mortar based on dune sand formulated has a very satisfactory compressive strength, a very low water porosity compared to ordinary cement mortar and that this mortar allows an improvement in the protection of the concrete against the carbonation of 60% compared to ordinary cement mortar based on alluvial sand. Moreover, the formulated cement mortars based on dune sand have good adhesion to the concrete support, their adhesion strengths are greater than 1.5MPa recommended by the standards.

An Experimental Study on Piping Feasibility of PE Compound Pipe for Fire Protection Service (PE 이종강관의 소방용 배관 적용성에 관한 실험적 연구)

  • Park, Jeong-Hwa;Oh, Cheon-Young;Kwark, Ji-Heon;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.55-61
    • /
    • 2016
  • In this study, to determine whether it is possible to apply Polyethylene (PE) compound pipe, which was developed to solve the problem caused by the corrosion of the fire protection piping currently in usein water based fire extinguishing systems, we performed an actual mockup fire test. Since no test standard was available related to the developed compound pipe, we compared and analyzed domestic and international technical materials and test standards and selected suitable fire test standards to evaluate the performance of the PE compound pipe. we applied two fire test standards to the PE compound pipe, viz. those for CPVC and metallic pipes, and conducted a total of 6 experiments to evaluate its performance. According to the results of the first and second fire tests based on the test standard for the CPVC pipe, neither the fitting nor the piping was damaged or deformed and no leakage was observed in the pressure test, which was performed for 5 minutes. For the fire test based on the metallic pipe test standard, a total of 4 experiments were conducted. The first two experiments were conducted to simulate the wet piping system. In the results of this fire test, neither leakage nor rupture was observed from the PE compound pipe and no damage was caused, such as the secession of the PE material. However, in the next two experiments, which simulated the dry system, the PE compound pipe suffered damage and rupture, including deformation before the fire fighting water was discharged. Therefore, we found that the piping performance of the PE compound pipe did not undergo any deterioration, including fusion, deformation, or damage, in the wet piping system simulated fire test.

Improvement of Hot Dip Galvanizing Process by Additive to Flux Solution (플럭스액의 첨가제에 의한 용융아연도금 공정개선)

  • Moon, Kyung-Man;Jeong, Jae-Hyun;Park, Jun-Mu;Lee, Myeong-Hoon;Baek, Tae-Sil
    • Journal of the Korean institute of surface engineering
    • /
    • v.49 no.6
    • /
    • pp.513-520
    • /
    • 2016
  • Many surface protection methods have been developed to apply to constructional steels which have been used under severe corrosive environments. One of these methods, hot dip galvanizing is being widely used to the numerous constructional steels such as a guard rail of high way, various types of structural steel for manufacturing ship and for some other industrial fields etc.. Recently, the cost of zinc is getting higher and higher, thus, it is considered that improvement of hot dip galvanizing process to reduce the cost of production should be developed possibly. In this study, additives such as acid cleaning solution, $NH_4OH$, $Al(OH)_3$ and $H_2O_2$ were added to flux solution, and omission of water washing treatment after acid cleaning was investigated with some types of flux solutions added with some additives mentioned above. The decrement of pH by adding the acid cleaning solution could be controlled due to neutralization reaction with addition of $NH_4OH$. The flux solution added with both $NH_4OH$ and $Al(OH)_3$ exhibited nearly the same color and pH value as those of orignal flux solution with no added, and the sample dipped to the flux solution which was added with additives mentioned above indicated a relatively good corrosion resistance compared to other samples. However, the flux solution added with $NH_4OH$, $Al(OH)_3$ and $H_2O_2$ exhibited a different color, sediment and a bad corrosion resistance. Consequently, it is considered that omission of water washing treatment may be able to perform by adding optimum additives to the original flux solution.

A Study on the Amendments of the Cathodic Protection Criteria Considering IR Drops (전압강하를 고려한 전기방식 기준 개정에 관한 연구)

  • Ryou, Young-don;Lee, Jin-han;Jo, Young-do;Kim, Jin-Jun
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.4
    • /
    • pp.50-57
    • /
    • 2016
  • According to the urban gas business legislation, cathodic protection systems should be applied for buried steel gas pipelines to prevent corrosion. In advanced countries including United States, the criteria for Cathodic Protection Potential is at least -850mV with respect to a saturated copper/copper sulfate electrode(CSE) when the CP applied, and the IR drops must be considered for valid interpretation. However, the IR drop through the pipe to soil boundary has been neglected in Korea. According to KGS code, a reference electrode must be placed in proximity to gas pipelines possible when measuring the CP potential. In this study, we have installed several solid reference electrodes around the buried pipeline(1.2m depth), lower surface(0.5m depth), and the surface individually in order to measure the CP potentials through the each reference electrode and find out the IR drops according to the location of each reference electrode. We have found the IR drop is the greatest when measuring the CP potential through the electrode placed on the ground and the IR drop is the smallest through the electrode installed near pipeline. Therefore, we have suggested the solid reference electrode should be installed as close as possible to buried pipeline in order to measure the correct CP potential without IR drop. We have also suggested the amendment of CP criteria considering IR drop.