• Title/Summary/Keyword: Corrosion in chloride environment

Search Result 204, Processing Time 0.023 seconds

The Effect of Surface Treatment Systems on Chloride Penetration in Cracked Concrete (표면도장공법에 의한 균열부 콘크리트의 염소이온 침투제어 특성)

  • Chae, Gyu-Bong;Yoon, In-Seok;Lee, Chang-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.525-528
    • /
    • 2008
  • For well-constructed concrete, its service life is a long term and it has an enough durability performance. However, for cracked concrete, it is clear that cracks should be preferential channel for the penetration of aggressive substance such as chloride ions according to author's previous researches. In order to enhance the lifetime of cracked concrete, critical issues in the performance of the concrete is the risk of chloride-induced corrosion. Even though crack width can be reduced due to the high reinforcement ratio, the question is to which extend these cracks may jeopardize the durability of cracked concrete. If the size of crack is small, surface treatment system can be considered as one of the best options to extend the service life of concrete structures exposed to marine environment simply in terms of cost effectiveness versus durability performance. Thus, it should be decided to undertake an experimental study on the effect of different types of surface treatment system, which are expected to seal the concrete and the cracks to chloride-induced corrosion in particular. In this study, it is examined the effect of surfaced treated systems on chloride penetration through microcracks. Single surface treatments of penetrant or coating and double application were considered as an experimental variation. RCM (Rapid Chloride Migration) testing is accomplished to visualize chloride penetration via cracks.

  • PDF

Influence of Cement Type on the Diffusion Characteristics of Chloride Ion in Concrete (콘크리트의 염소이온 확산특성에 미치는 시멘트 종류의 영향)

  • Park, Jae-Im;Bae, Su-Ho;Lee, Kwang-Myong;Kim, Jee-Sang;Cha, Soo-Won
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.573-576
    • /
    • 2006
  • To predict service life of concrete structures exposed to chloride attack, surface chloride concentration, diffusion coefficient of chloride ion, and chloride corrosion threshold value in concrete, are used as important factors. of these, as the diffusion coefficient of chloride ion for concrete is strongly influenced by concrete quality and environmental conditions of structures and may significantly change the service life of structures, it is considered as the most important factor for service life prediction. The qualitative factors affecting the penetration and diffusion of chloride ion into concrete are water-binder(W/B) ratio, age, cement type and constituents, chloride ion concentration of given environment, wet and dry conditions, etc. In this paper the influence of cement type on the diffusion characteristics of chloride ion in concrete was investigated through the chloride ion diffusion test. For this purpose, the diffusion characteristics in concrete with cement type such as ordinary portland cement(OPC), binary blended cement(BBC), and ternary blended cement(TBC) were estimated for the concrete with W/B ratios of 32% and 38%, respectively. It was observed from the test that the difussion characteristics of BBC containing OPC and ground granulated blast-furnace slag was found to be most excellent of the cement type used in this study.

  • PDF

Particle filter for model updating and reliability estimation of existing structures

  • Yoshida, Ikumasa;Akiyama, Mitsuyoshi
    • Smart Structures and Systems
    • /
    • v.11 no.1
    • /
    • pp.103-122
    • /
    • 2013
  • It is essential to update the model with reflecting observation or inspection data for reliability estimation of existing structures. Authors proposed updated reliability analysis by using Particle Filter. We discuss how to apply the proposed method through numerical examples on reinforced concrete structures after verification of the method with hypothetical linear Gaussian problem. Reinforced concrete structures in a marine environment deteriorate with time due to chloride-induced corrosion of reinforcing bars. In the case of existing structures, it is essential to monitor the current condition such as chloride-induced corrosion and to reflect it to rational maintenance with consideration of the uncertainty. In this context, updated reliability estimation of a structure provides useful information for the rational decision. Accuracy estimation is also one of the important issues when Monte Carlo approach such as Particle Filter is adopted. Especially Particle Filter approach has a problem known as degeneracy. Effective sample size is introduced to predict the covariance of variance of limit state exceeding probabilities calculated by Particle Filter. Its validity is shown by the numerical experiments.

The Study on the Durability Estimation of Concrete Contained Chloride ion by Individual and Combined Deterioration (단독 및 복합열화 환경하에서 염화물을 함유한 콘크리트의 내구성 평가에 관한 연구)

  • Kim Young Sun;Moon Hyung Jae;Cho Bong Suk;Kim Jae Hwan;Kim Gyu Yong;Kim Moo Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.503-506
    • /
    • 2005
  • Recently, corrosion of reforcement of reinforced concrete structures and carbonation is raised problem of durability because of exhaustion of river sand and rapid increase of sea sand and also, concrete structure of sea environment is attacked to combined deterioration according to penetration of chloride ion and carbonation, change of temperature, repetition of dryness and wetness. Therefore, In this study, data base were presented to solve the problem about using sea sand to concrete structure situated in combined deterioration environment by exposuring concrete specimen contained chloride ion under the individual and combined deterioration.

  • PDF

Corrosion Resistance of Cr-bearing Rebar to Macrocell Corrosion Caused by Concrete with Crack (피복 콘크리트의 균열 발생에 기인한 매크로셀 부식 환경하에서의 Cr강방식철근의 방식성)

  • Tae, Sung-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.4
    • /
    • pp.79-86
    • /
    • 2006
  • This study was investigated to corrosion resistance of Cr-bearing rebars to macrocell corrosion caused by concrete with crack. Ten types of steel bars having different Cr contents were embedded in concretes with imitation crack. The corrosion resistance of the Cr-bearing rebar was examined by measuring half-cell potential, macrocell corrosion current, corrosion area and weight loss up to 105 cycles of salt spray testing. The results revealed that the Cr content required for corrosion resistance in a macrocell corrosion environment caused by chloride ion gap of $3kg/m^3$ was 9% or more. The corrosion-resisting performance of Cr-bearing rebar was particularly noticeable with a Cr content of 11% or more.

An Experimental Study on the Salt Resistance Properties with Concrete Materials under Marine Exposure Environment (I) (해양환경에 폭로한 콘크리트의 내염특성에 대한 실험적 연구 (I))

  • 신도철;김영웅;김용철;김동철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.51-56
    • /
    • 2002
  • Protection against salt attack in seawater is obtained by using a dense, quality concrete with a low water-cement ratio, and a components appropriate for producing concrete having the needed salt resistance. The objective of this study is to evaluate the feature of corrosion with using the various concrete materials under marine exposure environment. According to the test results, slag powder and anti -corrosion inhibitor showed high chloride resistance effect. Also concre crack have an influence on corrosion of steel in spite of mixed design for salt resistance concrete. The requirement for low permeability is essential not only to delay the effect of salt attack, but also to afford adquate protection to reinforcement with admixtures.

  • PDF

Effect of cavitation on surface damage of 16.7Cr-10Ni-2Mo stainless steel in marine environment (해양 환경 하에서 16.7Cr-10Ni-2Mo 스테인리스강의 표면 손상에 미치는 캐비테이션의 영향)

  • Chong, Sang-Ok;Han, Min-Su;Kim, Seong-Jong
    • Corrosion Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.239-246
    • /
    • 2015
  • Stainless steel is generally known to have characteristics of excellent corrosion resistance and durability, but in a marine environment it can suffer from localized corrosion due to the breakdown of passivity film due to chloride ion in seawater. Furthermore, the damage behaviors are sped up under a cavitation environment because of complex damage from electrochemical corrosion and cavitation-erosion. In this study the characteristics of electrochemical corrosion and cavitation erosion behavior were evaluated on 16.7Cr-10Ni-2Mo stainless steel under a cavitation environment in natural seawater. The electrochemical experiments have been conducted at both static conditions and dynamic conditions inducing cavitation with different current density parameters. The surface morphology and damage behaviors were compared after the experiment. After the cavitation test with time variables morphological examinations on damaged specimens were analyzed by using a scanning electron microscope and a 3D microscope. the galvanostatic experiment gave a cleaner surface morphology presented with less damage depth at high current density regions. It is due to the effect of water cavitation peening under the cavitation condition. In the cavitation experiment, with amplitude of $30{\mu}m$ and seawater temperature of $25^{\circ}C$, weight loss and cavitation-erosion damage depth were dramatically increased after 5 hours inducing cavitation.

Corrosion Inhibition of Steel for Water Pipe Line by Adding a Non-Toxic Spearmint Extracts

  • Farooq, Hina;Kim, Jae-Yeon;Lee, Do-Il;Byeon, Jai-Won
    • Journal of Applied Reliability
    • /
    • v.17 no.2
    • /
    • pp.122-128
    • /
    • 2017
  • Purpose: To investigate the corrosion inhibition effect of the natural spearmint oil extracted from Mentha Spicata plants on 304 stainless steel in different concentrations of hydrochloric acid. Method: The anti-corrosive effect has been investigated in 0.5m, 1m and 2m HCl using weight loss test and electrochemical polarization method as a function of inhibitor concentration and immersion time in strong chloride environment. The surface morphology was analysed by scanning electron microscopy (SEM). Results: The corrosion rate of steel decreased and inhibition efficiency increased with the increase in inhibitor concentration. Microscopic evaluation revealed significant corrosion in the specimens immersed in uninhibited conditions. Potentiodynamic polarization test results showed an increase in corrosion potential (Ecorr) and decrease in corrosion current (icorr) value with increasing concentration of inhibitor. Conclusions: Immersion of steel in higher concentration of inhibitor resulted in greater surface coverage value and hence lesser number of surface corrosion sites/pores were formed; thus lowering the corrosion rate.

Assessment of Atmospheric Corrosivity at Jeju Island (제주도 대기환경의 부식성 평가)

  • KIM GUI-SHIK;YANG KYEONG-CHO;HU CHUL-GOO;SONG JEONG-HWA
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.253-259
    • /
    • 2004
  • The Jeju Island in Korea is the clean area which the tradition culture is preserved locally well with the nature environment of Heaven's blessing. An air pollution is becoming recently serious problem as the industrial development is proceeded with the urbanization. This study investigates that the atmosphere environment at Jeju area influences on the metal corrosion. A study of the atmosphere corrosion for carbon steel, copper, zinc ana aluminium exposed on five test sites indoors and outdoors. Corrosion results are treated statistically and adjusted to a model previously proposed for carbon steel, copper, zinc and aluminium based on the influence of environmental parameters and main pollutants($SO_2$ and chlorides) on tire atmosphere corrosion of metals. Through this study, we try to set the standards atmosphere corrosion at Jeju Island.

  • PDF

Distribution properties of seasonal airborne sea salt in the seashore (해안가의 계절별 비래염분량의 분포 특성)

  • Lee, Jong-Suk;Choi, Won-Sung;Moon, Han-Young
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.237-240
    • /
    • 2004
  • When the concrete structures are in contact with seawater, concentration of chloride for estimating chloride diffusion coefficient can be defined as the chloride concentration of sea water. However, in case the concrete structures, constructed in the seashore, aren't directly in contact with seawater, it is difficult to establish the interface concentration of chloride. In addition, marine concrete structures are greatly affected by salt attack such as rebar corrosion, among the cause of salt attack, airborne sea salt is primary factor. Therefore, in this study, salt attack environment by airborne sea salt was investigated in terms of a seasonal distribution at 33 spots, 6 areas in the East, West, South coast for 1 year. Results indicated that in the South coast, the amount of the airborne sea salt is comparatively higher in summer. in the West coast. higher in winter. On the other hand, in the East coast, the amount of the airborne sea salt is rarely affected by a season.

  • PDF