• Title/Summary/Keyword: Corrosion effect

Search Result 1,772, Processing Time 0.025 seconds

The Effect of Temperature on Corrosion of Absorption Refrigeration Systems Using LiBr-$H_2O$ Working Fluids (LiBr-$H_2O$계 흡수식냉동기의 부식에 미치는 온도의 영향)

  • 임우조;정기철;윤병두;강성수
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.92-97
    • /
    • 2001
  • This paper was studied on the effect of temperature on corrosion of absorption refrigeration systems using LiBr-$H_2O$ working fluids. In the fresh water and 62 %lithium bromide solution at $70^{\circ}C$, polarization test of SS 400, Cu(Cl220T-OL) and Ni-Al bronze was carried out. And Polarization behavior, polarization resistance characteristics, corrosion rate(mmpy) and corrosion sensitivity of materials forming absorption refrigeration systems was considered. The main results are as following: As the experimental temperature increase, the change of corrosion rate of Ni-Al bronze become duller than SS 400 and Cu in 62 % lithium bromide solution. Open circuit potential of SS 400 is less noble than that of Cu and Ni-Al bronze in fresh water, but that becomes noble than Cu and Ni-Al bronze in 62 % lithium bromide solution. The corrosion sensitivity of Ni-Al bronze was controlled than that of Cu and SS 400 in 62% LiBr solution.

  • PDF

Effect of Tropical Atmosphere on Corrosion of Different Metals

  • Wijesinghe, Sudesh;Zixi, Tan
    • Corrosion Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.273-277
    • /
    • 2017
  • Atmospheric corrosion is clearly the most noticeable of all corrosion processes. A tremendous amount of economic losses are caused by atmospheric corrosion. Thus, it is imperative to know the level of atmosphere's aggressiveness or in other words "corrosivity", before designing or planning any corrosion prevention strategy. In Singapore, corrosivity values were not recorded earlier though the process of measurement and recording was prevalent in other countries. With an aim of filling this gap, three test sites were setup at three locations in Singapore to represent marine, industrial and urban atmospheres or their mixtures. Subsequently, corrosivity readings were measured and recorded according to ISO 9223:2012 for the first time in Singapore. Salient atmospheric constituents or parameters like time of wetness (TOW), $Cl^-$, $SO_2$, $NO_2$, $O_3$, and $HNO_3$ were measured at all sites over a period of time to categorize corrosivity of particular atmosphere. The effect of the atmosphere on corrosion of steel, Cu, Al, and Zn has also been investigated and quantified. "Estimated" and "determined" corrosivities were quantified and compared according to ISO 9223 standard. The study data along with final corrosivity measurements will be presented and discussed in the present work.

Sensitivity to Intergranular Corrosion According to Heat Treatment of 304L Stainless Steel (304L 스테인리스강의 열처리에 따른 입계부식민감도 연구)

  • Jang, Hyung-Min;Kim, Dong-Jin;Kim, Hong-Pyo
    • Corrosion Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.37-42
    • /
    • 2020
  • Even though 304 low-carbon (304L) stainless steel was developed to enhance the resistance to intergranular corrosion and stress corrosion cracking, it is occasionally subject to degradation in harsh environments. The degree of sensitization (DOS) of 304L stainless steel was studied as a function of sensitization using a double-loop electrochemical potentiokinetic reactivation (DL-EPR) method. Sensitizing heat treatment was performed in an Ar atmosphere at 500℃, 600℃, and 700℃, with heat treatment times varying from 0 to 96 h. DOS was measured by the ratio of the peak current density value of the forward scan to that of the reverse scan. After the EPR experiment, the specimen surface was observed by scanning electron microscopy and energy dispersive spectroscopy. The DOS of the specimens heat-treated at 600℃ increased with heat treatment times up to 48 h and then decreased due to a self healing effect. The DOS was higher in specimens heat-treated at 600℃ than those at 500℃ or 700℃. Corrosion of the sensitized specimens occurred mainly at the δ-γ phase boundary. The corrosion morphology at the δ-γ phase boundary changed with sensitizing heat-treatment conditions due to differences in chromium activity in γ austenite and δ ferrite.

Effect of Microstructure on the Corrosion Resistance of Nd-Fe-B Permanent Magnets

  • Li, Jiajie;Li, Wei;Li, Anhua;Zhao, Rui;Lai, Bin;Zhu, Minggang
    • Journal of Magnetics
    • /
    • v.16 no.3
    • /
    • pp.304-307
    • /
    • 2011
  • High performance Nd-Fe-B magnets can be manufactured by both sintering and hot deformation. The corrosion behaviors of the magnets prepared by the two processes were compared. Effect of microstructure on the corrosion resistance of Nd-Fe-B magnets was also investigated. A neutral salt spray test (NSS) was performed for the different-processed magnets. The weight losses of the samples after the corrosion test were measured. The corrosion microstructures were observed using a scanning electron microscope. It shows that the corrosion resistance of hot deformed magnets is much better than that of the sintered ones because the grain size and the distribution of Nd-rich phases of the hot deformed magnets are much finer and more uniform than those of the sintered ones. The different microstructure between the sintered and the hot deformed magnets causes the different corrosion behavior.

Effect of Delayed Oxygen Evolution in Anodic Polarization on the Passive Film Characteristic and Localized Corrosion Resistance of Titanium Alloys (타이타늄 합금에서 산소발생전위 지연이 부동태 피막 특성과 국부부식 저항성에 미치는 영향)

  • Oh, Yu Soo;Seo, Dong-Il;Lee, Jae-Bong
    • Corrosion Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.156-162
    • /
    • 2020
  • The objective of this study was to investigate delayed oxygen evolution and localized corrosion resistance of titanium alloys by performing potentiodynamic polarization, potentiostatic polarization, and Mott-Schottky measurements. Delayed oxygen evolution was compared among titanium alloys, 316 stainless steel, and platinum. Difference in delayed oxygen evolution between titanium alloys and other metals was attributed to specific surface characteristic of each metal. Delayed oxygen evolution of titanium alloys resulted from the predominant process of ionic conduction over electronic conduction. The effect of oxygen evolution on localized corrosion of titanium alloys was investigated using electrochemical critical localized corrosion temperature (E-CLCT) technique. Mott-Schottky measurement was performed to clarify the difference in film properties between titanium alloys and stainless steels. Titanium alloys were found to have much lower donor density than stainless steels by 1/28. These results indicate that delayed oxygen evolution has little influence on the concreteness of passive film and the resistance to localized corrosion of titanium alloys.

Effect of the Heat treatment and Boron on the Hot Corrosion Resistance of the Al Diffusion Coating (Al 확산피복층의 고온 내식성에 미치는 후열처리와 B첨가의 영향)

  • 김태원;윤재홍;이재현;김현수;변응선
    • Journal of Surface Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.67-77
    • /
    • 1999
  • The Ni base superalloy Mar-M247 substrate was aluminized or aluminized after boronizing by the pack cementation under Ar atmosphere. The hot corrosion resistance and after-heat-treatment effect of aluminized specimens were studied by the cyclic hot corrosion test in $Na_2SO_4$-NaCl molten salt. XRD analysis showed that the $Ni_2Al_3$ phase was formed between the coated layer and substrate below 1273K but the NiAl phase above 1273K. The peak of the NiAl phase was developed after heat treatment. Corrosion test showed that corrosion resistance of the specimen with the NiAl phase was better than that with the $Ni_2Al_3$ phase. Corrosion resistance could be improved by heat treatment to form ductile NiAl phase, where cracks were not formed by thermal shock on coating layer. Moreover, it appeared that heat treatment played a role to improve corrosion resistance of Al diffusion coating above 1273K. The existence of boron in the Al diffusion coating layer obstructed outwared diffusion of Cr from the substrate, and it influenced on corrosion resistance of the coating layer by weakening adherence of the oxide scale.

  • PDF

The Effect of External DC Electric Field on the Atmospheric Corrosion Behaviour of Zinc under a Thin Electrolyte Layer

  • Liang, Qinqin;YanYang, YanYang;Zhang, Junxi;Yuan, Xujie;Chen, Qimeng
    • Corrosion Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.54-59
    • /
    • 2018
  • The effect of external DC electric field on atmospheric corrosion behavior of zinc under a thin electrolyte layer (TEL) was investigated by measuring open circuit potential (OCP), cathodic polarization curve, and electrochemical impedance spectroscopy (EIS). Results of OCP vs. time curves indicated that the application of external DC electric field resulted in a negative shift of OCP of zinc. Results of cathodic polarization curves measurement and EIS measurement showed that the reduction current of oxygen increased while charge transfer resistance ($R_{ct}$) decreased under the external DC electric field. Variation of OCP negative shift, reduction current of oxygen, and $R_{ct}$ increase with increasing of external DC electric field strength as well as the effect of external DC electric field on double-layer structure in the electrode/electrolyte interface and ions distribution in thin electrolyte layer were analyzed. All results showed that the external DC electric field could accelerate the corrosion of zinc under a thin electrolyte layer.

Effect of Stress on the Polarization Characteristic of Al-brass (Al-황동의 분극특성에 미치는 응력의 영향)

  • Lim, Uh-Joh;Jeong, Hae-Kyoo;Sim, Kyong-Tae
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.2
    • /
    • pp.1-5
    • /
    • 2004
  • Al-brass is the raw material of mnufacturing tubes for heat exchanger of vessel where seawater is used to coolant because it has high level of heat coductivity and excellent mechanical properties and high level of corrosion resistance due to cuprous oxide($Cu_2O$) layer against seawater. However, damage of Al-brass tubes for heat exchanger of vessel is reported that local corrosion such as stress corrosion cracking occurred by synergism effect between mechanical factor and corrosion environment. In this study, to investigate on the effect of stress on the polarization characteristics of Al-brass. At the stress of 0% and 95% yield strength by constant displacement tester, in 3.5% NaCl + 0.1% $NH_4OH$ solution, the polarization tests were carried out. And thus open circuit potential, corrosion current density, anodic polarization, cyclic polarization and dezincification behavior of Al-brass are investigated.

Chemical Cleaning of Copper Corrosion Product Using EDTA.2Na Salt and Effect of Surface Treatment by NALCO-39L (EDTA.2Na를 이용한 구리 부식생성물의 화학세정 및 NALCO-39L에 의한 표면처리효과)

  • 이한철;이창우;현성호
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.1
    • /
    • pp.86-92
    • /
    • 1999
  • This study was carried out to investigate the effect of chemical cleaning of corrosion product on cooling system made of copper as a basic material and using cooling water as pure water. We studied chemical cleaning condition that minimizes the influence on basic material by means of EDTA solution so as to eliminate the slurry in cooling system. In addition, the proper amount of NALCO-39L (Nitrite-Borate-BZT mixture) as a inhibitor was determined in order to protect the copper in cooling system against corrosion after chemical cleaning and the effect of corrosion resistance on the copper surface treated was excelent in comparison with surface untreated. As a result, we found that the main components of sludge in cooling system produced by corrosion of copper were $Cu_2O$, CuO, Cu, and Fe. The optimum condition of chemical cleaning was 400ppm EDTA solution at $60^{\circ}C$. Inhibitor concentration needed to treat the surface of pure copper was 15~20ppm per unit area and corrosion rate of copper treated with 500ppm inhibitor solution for 72 hrs at $60^{\circ}C$ was remarkably decreased as compared with that of pure copper.

  • PDF

Evaluation of Corrosion Protective System for Reinforced Concrete Structures Constructed With Sea Sand (해사 혼입된 콘크리트 구조물의 부식도 평가)

  • 김웅희;홍기섭;오승모;장지원;최응규;최완철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.04a
    • /
    • pp.203-209
    • /
    • 1997
  • An experimental study to evaluate to evaluate corrosion protection systems was undertaken with 44 reinforced concrete slab specimens subjected to cyclic wet and dry saltwater exposure. Corrosion measurements included monitoring macrocell corrosion currents, which are genrerally accecpted in United States practice. Test results indicate that specimens containing 2 kg/$\textrm{m}^3$ of NaCl and exposed to wet(outdoor) and dry(indoor) conditions but not to saltwater show very low values of corrosion measurements regardless applying any corrosion protective systems. Corrosion currents of the specimens exposed at 10 percent of NaCl were higher than that of the specimen exposed at 5 percent of NaCl, so the density of the salt water had an influential effect on the test. For the specimens with water repellent membrane currents kept relatively low numerical values, but test specimens with surface corrosion inhibitor protective system showed high values of corrosion current. It would be expected that evaluation of the corrosion protective systems need long-term measurement.

  • PDF