• 제목/요약/키워드: Corrosion coupon

검색결과 30건 처리시간 0.024초

Corrosion Rate of Buried Pipeline by Alternating Current

  • Song, H.S.;Kim, Y.G.;Lee, S.M.;Kho, Y.T.;Park, Y.S.
    • Corrosion Science and Technology
    • /
    • 제4권1호
    • /
    • pp.1-7
    • /
    • 2005
  • An alternating current (AC) corrosion on buried pipeline has been studied using coupon and ER probe. Coupons and ER probes were applied to the sites from high value of AC voltage to low value based on the survey of AC voltages on buried gas transmission pipeline over the country. Parameters such as AC current density of coupon, AC voltage, cathodic protection potential, soil resistivity and frequency were monitored continually. Corrosion induced by AC was observed even under cathodically protected condition that met cathodic protection criterion (; below -850 mV vs. CSE). Corrosion rate was affected mainly not by AC voltage but by both of frequency and AC current density. An experimental corrosion rate relation could be obtained according to effective AC current density, in which AC corrosion rate increased linearly with effective AC current density, and its slope was 0.619 in coupon method and 0.885 in ER probes.

교류가 유도되는 매설배관에서의 교류 부식속도 측정에 관한 연구 (Corrosion Rate of Buried Pipeline by Induced Alternating Current)

  • 송홍석;김영근;이성민;고영태;박용수
    • 한국가스학회지
    • /
    • 제5권3호
    • /
    • pp.63-72
    • /
    • 2001
  • 천연가스 공급용 고압 지하 매설배관에 교류가 유도될 때 쿠폰과 전기저항형 박막센서를 이용하여 교류에 의한 부식속도를 평가하고 주요한 인자를 규명하고자 하였다. 전국에 걸쳐 조사된 교류전압 측정결과를 바탕으로 쿠폰과 전기저항형 박막센서를 설치하고, 주요인자를 고찰하기 위하여 다양한 인자들 (교류전압, 교류전류, 토양 비저항, 주파수, 방식전위)을 정기적으로 기록하였다. 황산동 전극기준 -850mV의 방식전위를 충분히 만족하는 상황에서도 교류에 의한 부식이 진행하였으며, 교류에 의한 부식속도는 교류전압과는 관계없이 교류전류밀도와 주파수에 의존하는 것으로 나타났다. 교류에 의한 부식속도는 유효교류전류밀도에 따라 직선적으로 증가하였으며, 쿠폰에 의한 평가결과 직선의 기울기는 0.619, 전기저항형 센서에 의한 직선의 기울기는 0.885로 나타났다.

  • PDF

Involvement of Organic Acid During Corrosion of Iron Coupon by Desulfovibrio desulfuricans

  • Park, Kyung-Ran;Lee, Hyun-Jin;Lee, Hong-Keum;Kim, Yeong-Kwan;Oh, Young-Sook;Choi, Sung-Chan
    • Journal of Microbiology and Biotechnology
    • /
    • 제13권6호
    • /
    • pp.937-941
    • /
    • 2003
  • Microbiologically influenced corrosion (MIC) is an electrochemical process where the participation of microorganisms initiates, facilitates, or accelerates the corrosion reaction. Sulfate-reducing bacteria (SRB) reduce sulfate to sulfide and are known to be the most destructive microorganisms in anaerobic MIC. Accordingly, the current study attempted to elucidate the mechanisms involved and the relative importance of the corrosive products in SRB-induced corrosion. The measured rate of anaerobic corrosion of iron coupons by Desulfovibrio desulfuricans was $89.9{\;}\mu\textrm{g}{\;}\textrm{m}^{-2}{\;}d^{-1}$. Direct contact between the cells and the iron coupon did not seem to be necessary for corrosion to occur, since the corrosion rate was similar ($100.8{\;}\mu\textrm{g}{\;}\textrm{m}^{-2}{\;}d^{-1}$) when the coupon was enclosed in a dialysis bag. The participation of sulfide in the corrosion process was only marginal, as the specific corrosion rate was 2.5 times higher in a sulfate-free pyruvate medium than in an $H_2S-producing$ lactate medium. Acetate (18.8-22.1 mM), the end-product of pyruvate and lactate metabolism, was identified in the culture medium and thus presumed to play a major role in the corrosion process involving Desulfovibrio desulfuricans.

토양 특성 및 전기방식에 따른 연료 가스용 강관의 부식 차이에 관한 연구 (A Study on the Corrosivity according to Soil Characteristics and Electrolytic Protection for the Materials of Fuel Gas Pipe)

  • 임상식;김지선;류영돈;이진한
    • 한국가스학회지
    • /
    • 제20권6호
    • /
    • pp.16-22
    • /
    • 2016
  • 연료가스용 탄소강관이 지하에 매설되는 경우 부식을 방지하기 위해 피복강관을 사용하고 있으며, 피복강관의 결함, 타공사, 시공시 피복의 손상에 대비하여, 방식전위를 이용하여 환원 분위기를 강제로 조성한다. 일반적으로 연료가스용 탄소강관이 지하에 매설된 경우 두 방법이 병행되어 사용되지만, 토양환경의 변화를 예측 할 수 없는 불확실성과 부식 정도 또는 피복의 손상 등 배관의 결함에 대해 육안으로 직접 관찰하기 어려운 문제가 공존한다. 매설배관의 부식이 발생하는 것을 직접적으로 관찰하기 어렵기 때문에, 이를 직접적으로 관찰하기 위한 방법 중 하나가 부식쿠폰을 이용한 방법이다. 본 연구에서는 3가지 토양(마사토, 진흙, 모래)과 방식전위 사용 여부에 따라 작성된 6가지의 시나리오를 토대로 약 1년간 부식쿠폰의 부식 정도를 파악하였다. 그 결과 방식전위가 흐르는 환경의 부식쿠폰은 부식이 전혀 발생하지 않았으며, 미방식 부식쿠폰은 모두 부식이 발생하였다. 토양에 따라서는 진흙에서 가장 적은 부식속도를 보였으며, 모래와 마사토는 유사한 경향을 갖는 것으로 확인되었다. 진흙의 경우 높은 함수량에 의해 국부부식이 발생하였으며, 모래에서 부식이 발생한 것은 모래에 함유된 화학적 성분에 기인한 것으로 확인되었다.

교류가 유도되는 매설배관에서의 교류 부식속도 측정에 관한 연구 (Corrosion Rate of Buried Pipeline by Induced Alternating Current)

  • 송홍석;김영근;이성민;고영태;박용수
    • 한국가스학회:학술대회논문집
    • /
    • 한국가스학회 2001년도 추계학술발표회 논문집
    • /
    • pp.45-57
    • /
    • 2001
  • An alternating current (AC) corrosion using coupon has been studied. Coupons were applied in terms of AC voltage from high value to low value through the survey of AC voltages on buried gas transmission pipeline over the country. Parameters such as AC current density of coupon, AC voltage, cathodic protection potential, soil resistivity and frequency were monitored continually. Corrosion induced by AC was observed even under cathodically protected condition that met cathodic protection criterion(: below -850mv vs. CSE). Corrosion rate was affected mainly not by AC voltage but by both of frequency and AC current density. An experimental corrosion rate relationship could be obtained statistically, in which AC corrosion rate increased linearly with effective AC current density and its slope was 0.619.

  • PDF

온도변화에 따른 주석 도금한 전기 커넥터의 미동마멸 부식 거동 (Fretting Corrosion Behavior of Tin-plated Electric Connectors with Variation in Temperature)

  • 오만진;강세형;이만석;김호경
    • Tribology and Lubricants
    • /
    • 제30권3호
    • /
    • pp.146-155
    • /
    • 2014
  • In this study, we conduct fretting corrosion tests on tin-plated brass coupons to investigate the effect of temperature on fretting corrosion for various span amplitudes. We prepare a coupled fretting corrosion specimens using a tin-plated brass coupon with a thickness of $10{\mu}m$. One specimen is a flat coupon and the other specimen is a coupon with a protuberance in 1 mm radius, which is produced using 2 mm diameter steel ball. We conduct fretting corrosion tests at $25^{\circ}C$, $50^{\circ}C$, $75^{\circ}C$, $100^{\circ}C$ by rubbing the coupled coupons together at the contact between the flat and protuberance coupons. We measure electric resistance of the contact during the fretting corrosion test period. There is increase in resistance with fretting cycles. It is found that rate of increase in electric resistance becomes faster with increase in testing temperature. Magnitude of friction coefficient increases with fretting span amplitudes. And, change in friction coefficient becomes desensitized to the increment in span amplitude. Assuming that failure cycle is the cycle with an electric resistance of $0.01{\Omega}$, we find that failure lifetime ($N_f$) decreases with increase in testing temperature. Furthermore, based on the assumption that the damage rate of the connector is inversely related to the failure cycle, we calculate the activation energy for fretting damage to be 13.6 kJ/mole by using the Arrhenius equation. We propose a method to predict failure cycle at different temperatures for span amplitudes below $30{\mu}m$. Friction coefficients generally increase with increase in span amplitude and decrease in testing temperature.

Corrosion behavior of aluminum alloy in simulated nuclear accident environments regarding the chemical effects in GSI-191

  • Da Wang ;Amanda Leong;Qiufeng Yang ;Jinsuo Zhang
    • Nuclear Engineering and Technology
    • /
    • 제54권11호
    • /
    • pp.4062-4071
    • /
    • 2022
  • Long-term aluminum (Al) corrosion tests were designed to investigate the condition that would generate severe Al corrosion and precipitation. Buffer agents of sodium tetraborate (NaTB), trisodium phosphate (TSP) and sodium hydroxide (NaOH) were adopted. The insulation materials, fiberglass and calcium silicate (Ca-sil), were examined to explore their effects on Al corrosion. The results show that significant precipitates were formed in both NaTB/TSP-buffered solutions at high pH. The precipitates formed in NaTB solution raise more concerns on chemical effects in GSI-191. A passivation layer formed on the surfaces of coupon in solution with the presence of insulations could effectively mitigate Al corrosion. The Fe-enriched intermetallic particles (IPs) embedded in coupon appeared to serve as seeds to readily induce precipitation via providing extra area for heterogeneous Al hydroxide precipitation. X-ray spectroscopy (EDS) and X-ray diffraction (XRD) analyses indicate that the precipitates are mainly boehmite (γ-AlOOH) and no direct evidence confirms the presence of sodium aluminum silicate or calcium phosphate.

소석회와 CO2를 이용한 상수관로의 부식제어(II) - 관종별 부식특성 평가 (Corrosion Control in Water Distribution System using Lime and Carbon Dioxide(II) - Evaluation on the Characteristics of Corrosion as a Function of Pipe Material)

  • 이두진;김영일;송영일;박현아
    • 상하수도학회지
    • /
    • 제22권3호
    • /
    • pp.379-387
    • /
    • 2008
  • The pH & alkalinity adjustment method by lime and carbon dioxide($CO_2$) for corrosion control in water distribution system was investigated to evaluate the corrosion characteristics of metal pipes, such as galvanized iron, copper, stainless steel, and carbon steel. When the pH in sand filtered and ozone+GAC treated water was increased with lime and $CO_2$ from 7.5 to 8.0, the concentration of residual chlorine decreased at higher pH and longer reaction time; the concentration of trihalomethane increased. The corrosion rate of coupons with corrosion control using lime and carbon dioxide was showed much smaller than those without corrosion control using pilot-scale simulated distribution system. The galvanized iron was corroded much faster than carbon steel, copper, and stainless steel. Especially, copper and stainless steel coupons were hardly corroded. The galvanized iron and carbon steel coupons with corrosion control were produced the corrosion products less than those without corrosion control by the results of environmental scanning electron microscope(ESEM) and energy dispersive x-ray spectroscopy(EDS) analyses. The galvanized iron coupon with pH and alkalinity adjustment by lime and carbon dioxide was detected about 30 percent of zinc, when the carbon steel was detected about 30 percent of calcium by calcium carbonate products formation. For the results of X-ray diffraction(XRD) analyses, the goethite(${\alpha}$-FeOOH) was identified as primary corrosion product of galvanized iron without corrosion control, while the Zinc oxide(ZnO) was found on corrosion products of galvanized iron coupon with corrosion control as the results of EDS analyses. However, the carbon steel corrosion products regardless of corrosion control were composed predominantly of maghemite(${\gamma}-Fe_2O_3$) and hematite(${\alpha}-Fe_2O_3$).

Experimental and numerical studies on the behaviour of corroded cold-formed steel columns

  • Nie, Biao;Xu, Shanhua;Zhang, Haijiang;Zhang, Zongxing
    • Steel and Composite Structures
    • /
    • 제35권5호
    • /
    • pp.611-625
    • /
    • 2020
  • Experimental investigation and finite element analysis of corroded cold-formed steel (CFS) columns are presented. 11 tensile coupon specimens and 6 stub columns of corroded CFS that had a channel section of C160x60x20 were subjected to monotonic tensile tests and axial compression tests, respectively. The degradation laws of the mechanical properties of the tensile coupon specimens and stub columns were analysed. An appropriate finite element model for the corroded CFS columns was proposed and the influence of local corrosion on the stability performance of the columns was studied by finite element analysis. Finally, the axial capacity of the experimental results was compared with the predictions obtained from the existing design specifications. The results indicated that with an increasing average thickness loss ratio, the ultimate strength, elastic modulus and yield strength decreased for the tensile coupon specimens. Local buckling deformation was not noticeable until the load reached about 90% of the ultimate load for the non-corroded columns, while local buckling deformation was observed when the load was only 40% of the ultimate load for the corroded columns. The maximum reduction of the ultimate load and critical buckling load was 57% and 81.7%, respectively, compared to those values for the non-corroded columns. The ultimate load of the columns with web thickness reduced by 2 mm was 53% lower than that of the non-corroded columns, which indicates that web corrosion most significantly affects the bearing capacity of the columns with localized corrosion. The results predicted using the design specifications of MOHURD were more accurate than those predicted using the design specifications of AISI.

$CaCO_3$침전능 조절에 의한 금속시편에서의 부식방지 (The Corrosion Control Using CCPP(Calcium Carbonate Precipitation Potential )Index in Metallic Coupons)

  • 이재인;임진경;서상훈;김동윤;신춘환
    • 한국환경과학회지
    • /
    • 제9권6호
    • /
    • pp.505-509
    • /
    • 2000
  • The purpose of this study was to evaluate the effects of $Ca(OH)_2$ and $CO_2$ additions on the corrosion of metal coupons(ductile iron, galvanized steel, copper and stainless steel). Corrosion rate and released metal ion concentration of ductile iron and galvanized steel decreased by adjusting alkalinity, calcium hardness and pH with $Ca(OH)_2$ & $CO_2$ additions on copper and stainless steel were less than those on ductile iron and galvanized steel. When ductile iron coupon was exposed to water treated with Ca(OH)$_2$&$CO_2$, additions, the main components of corrosion product formed on its surface were $CaCO_3$ and $Fe_2 O_3 or Fe_2 O_4$ which often reduce the corrosion rate by prohibiting oxygen transport to the metal surface.

  • PDF