• 제목/요약/키워드: Corrosion Condition

검색결과 829건 처리시간 0.023초

Evaluation of Deterioration on Steel Bridges Based on Bridge Condition Ratings

  • Park, Chan-Hee
    • Corrosion Science and Technology
    • /
    • 제3권4호
    • /
    • pp.166-171
    • /
    • 2004
  • Recent developments in Bridge Management Systems (BMS) and in Life-Cycle Cost (LCC) of bridges, have raised the need for evaluation procedure of future condition (Deterioration) of a bridge. Predicting future deterioration is not an easy task due to limited past data to extrapolate from and also due to difficulty in measuring actual deterioration such as section loss of steel on an actual steel bridge. Also, increase in live load and reduction of resistance are random variables, thus a probabilistic approach should be adopted for determining the future deterioration. Due to difficulties in evaluation of future deterioration on steel bridges, accepting uncertainties within a reasonable error, a deterministic procedure using bridge condition rating can be a useful tool for projection of future condition of bridges to identify repair and maintenance needs. The object of this paper is to determine applicability of evaluating deterioration of steel bridge components based on Bridge condition ratings. Bridge condition ratings of bridge components show wide variation for bridges of same age and does not directly correlate well with the age of the bridge and/or deterioration of the bridge. High uncertainty can be reduced by breaking down the rating and by sensitivity analysis. From refined condition rating data, generalized deterioration profile of structures based on age can be derived. Examples are shown for sample bridges in USA. Approximately, 3,000 short to medium span steel bridges were listed in the inventory database. Results show wide variation of rating factors but by subdividing the Bridge condition ratings for various categories general deterioration profiles of steel bridges can be determined.

인공 해수 간헐 조건에서의 방청제 및 혼화재를 사용한 콘크리트 압축강도 및 저항의 특성 (The characteristics of compressive strength resistance of concrete combined with corrosion inhibitors and mineral admixtures under simulated tidal condition)

  • 이용은;장태순;양우석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회논문집(II)
    • /
    • pp.641-646
    • /
    • 1998
  • The structures exposed to marine environment do not show long-term durability due to corrosion of steel and deterioration of concrete by the attack of various salts dissolved in sea water. In this study, Partial substitution of cement with fly ash(20%) or blast furnace slag(40%) was made together with the addition of 4 different corrosion-inhibitors, as a protective measure of concrete structures against chemical attack of salts. Combined effects of mineral and corrosion-inhibiting admixtures were tested by measuring the resistance and compressive strength of concretes under the simulated tidal condition, which consists of alternating 12 hour periods of immersion in artificial sea water and drying in air. Both the strength and concrete resistance were found to decrease in following order, regardless of the corrosion inhibitors the concretes with blast furnace slag, those with fly ash and those without any mineral admixtures. The interrelation between compressive strength of concrete and resistance was investigated.

  • PDF

염화물 환경에 있는 에폭시도막철근의 부식 평가 연구 (Corrosion Evaluation of Epoxy-coated Bars in Chloride Contaminated Concrete Using Linear Polarization Tests)

  • 박영수;최경민;정시영;김병국;최완철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.254-257
    • /
    • 2006
  • Five bench scale specimens were used to evaluate corrosion performance of damaged epoxy-coated bars in chloride contaminated concrete. The test specimens were subjected 48 weekly cycles of ponding with sodium chloride solution and drying. Test results using linear polarization technique show that the current density of specimen with conventional steel becomes $0.715\;{\mu}A/cm^2$ indicating that the steel bars are in moderate or high corrosion condition. However, the corrosion rates of the specimens with damaged epoxy coated bars are much below $0.1\;{\mu}A/cm^2$ and the bars appears to be in passive condition. The corrosion protection performance provided by calcium nitrite is better than that of specimens with the other two inhibitors.

  • PDF

에폭시수지와 아질산형 하이드로칼루마이트를 병용한 폴리머 시멘트 모르타르의 강도 및 방청성 (Strengths and Corrosion-Inhibition of Epoxy-Modified Mortars Contaning Nitrite-Type Hydrocalumite)

  • 김주영;김완기
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.53-55
    • /
    • 2013
  • Nitrite-Type hydrocalumite (calumite) is a material that can provied a self-corrosion inhibition function to the reinforce concrete. In this study, bisphnol A·F type epoxy-midified mortars without hardner contaning calumite is prepared with various polimer-binder ratios, calumite contents and tow types of curing condition, and tested for flexural and compressive strength tensile strength and corrosion-inhibition. As a result, in the case of wet/dry curing condition, strengths of bisphnol A·F type epoxy-modified mortars without hardener contaning calumite is inclined to decrease with increasing of polymer-binder ratio and calumite content. However, dry cured specimens are slightly improved by using bisphnol A·F type epoxy resin. Finally, regardless of polymer-binder ratios and calumite contents, corrosion-inhibition of bisphnol A·F type epoxy-modified mortars without hardener containing calumite is superior than that of unmodified mortar.

  • PDF

고분자 전해질 연료전지 금속분리판 316L 스테인리스강의 부식거동 및 기체확산층(GDL)과의 계면접촉저항 측정 (Corrosion Behaviors of 316L Stainless Steel Bipolar Plate of PEMFC and Measurements of Interfacial Contact Resistance(ICR) between Gas Diffusion Layer(GDL) and Bipolar Plate)

  • 오인환;이재봉
    • Corrosion Science and Technology
    • /
    • 제9권3호
    • /
    • pp.129-136
    • /
    • 2010
  • The corrosion behaviors of 316L stainless steel were investigated in simulated anodic and cathodic environments for proton exchange membrane fuel cell (PEMFC) by using electrochemical measurement techniques. Interfacial contact resistance(ICR) between the stainless steel and gas diffusion layer(GDL) was also measured. The possibility of 316L was evaluated as a substitute material for the graphite bipolar plate of PEMFC. The value of ICR decreased with an increase in compaction stress(20 N/$cm^2$~220 N/$cm^2$) showing the higher values than the required value in PEMFC condition. Although 316L was spontaneously passivated in simulated cathodic environment, its passive state was unstable in simulated anodic environment. Potentiostatic and electrochemical impedance spectroscopy (EIS) measurement results showed that the corrosion resistance in cathodic condition was higher and more stable than that in anodic condition. Field emission scanning electron microscopy (FE-SEM), and inductively coupled plasma(ICP) were used to analyze the surface morphology and the metal ion concentration in electrolytes.

Crevice Corrosion Resistance of Stainless Steels in Natural Sea Water with different Post Welding Treatment

  • Lee, Y.H.;Kim, Y.H.;Kim, H.
    • Corrosion Science and Technology
    • /
    • 제2권5호
    • /
    • pp.219-224
    • /
    • 2003
  • Crevice corrosion of stainless steels in natural seawater was investigated for several post weld treatments; as-annealed, as-welded, pickled, and ground. The results confirmed the effect of the biofilm on the cathodic reaction leading to an ennoblement of the rest potential. The degree of ennoblement of corrosion potential depends on the surface finish. As-annealed and pickled samples show stable corrosion potential approaching to 200 ~ 300 mV (SCE) while as-welded and ground samples show the fluctuating corrosion potential. This points to a situation where there are conflicting effects determining the trend in free corrosion potential. Crevice corrosion initiation will tend to pull the free corrosion potential in the active direction, whereas the presence of biofilm will tend to ennoble corrosion potential. There was no visible attack on UNS S31803, S32550, and 2205W. Therefore, those stainless steel grades appeared to be resistant to crevice corrosion in natural seawater on condition of weld metal.

EVALUATION OF PH CONTROL AGENTS INFLUENCING ON CORROSION OF CARBON STEEL IN SECONDARY WATER CHEMISTRY CONDITION OF PRESSURIZED WATER REACTOR

  • Rhee, In Hyoung;Jung, Hyunjun;Cho, Daechul
    • Nuclear Engineering and Technology
    • /
    • 제46권3호
    • /
    • pp.431-438
    • /
    • 2014
  • The effect of various pH agents on the corrosion behavior of carbon steel was investigated under a simulated secondary water chemistry condition of a pressurized water reactor (PWR) in a laboratory, and the steel's corrosion performance was compared with the field data obtained from Uljin NPP unit 2 reactor. All tests were carried out at temperatures of $50^{\circ}C-250^{\circ}C$and pH of 8.5 - 10. The pH at a given temperature was controlled by adding different agents. Laboratory data indicate that the corrosion rate of carbon steel decreased as the pH increased under the test conditions and the highest corrosion rate was measured at $150^{\circ}C$. This high corrosion rate may be related to high dissolution and instability of Fe oxide ($Fe_3O_4$) at $150^{\circ}C$. It was also found that an addition of ethanolamine (ETA) to ammonia was more effectivefor anticorrosion than ammonia alone, and that mixed treatment reduced 50% of iron or more at pHs of 9.5 or higher, especially in the steam generator (SG) and the moisture separator & re-heater (MSR).

Metal 건식각 후처리에 따른 부식 특성에 관한 연구 (A Study on the corrosion property by post treatment in the metal dry etch)

  • 문성열;강성준;정양희
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2007년도 추계종합학술대회
    • /
    • pp.747-750
    • /
    • 2007
  • 본 연구는 부식을 방지하기 위해서는 metal line식각 후 염소 잔유물 과 plasma charge up을 식각 조건, PR strip조건 및 후속 세정 조건을 최적화함으로써 제거해야 한다고 제안 하였다. Metal line에 다량 분포하는 charge up은 후속 세정의 적정 PH와 만났을 때, 하부 tungsten plug의 부식을 유발 하게 된다. Metal line식각 및 PR strip후 세정에 있어 약액의 종류는 부식에 결정적인 영향을 미친다. Galvanic corrosion을 최소화하기 위한 적정 PH, metal attack을 최소화 할 수 있는 chemistry선택, 높은 식각 부산물 제거 효율의 약액, 최적의 $H_2O$처리 조건 등이 metal부식방지에 있어 결정적인 요소임을 확인하였다.

  • PDF

Cr 첨가가 고망간강의 중성 수용액 환경 내 유동가속부식 거동에 미치는 영향 (Effect of Cr Addition to High Mn Steel on Flow-Accelerated Corrosion Behaviors in Neutral Aqueous Environments)

  • 정영재;박진성;방혜린;이순기;최종교;김성진
    • Corrosion Science and Technology
    • /
    • 제20권6호
    • /
    • pp.373-383
    • /
    • 2021
  • The effect of Cr addition to high Mn steel on flow-accelerated corrosion (FAC) behavior in a neutral aqueous environment was evaluated. For comparison, two types of conventional ferritic steels (API X70 steel and 9% Ni steel) were used. A range of experiments (electrochemical polarization and impedance tests, weight loss measurement, and metallographic observation of corrosion scale) were conducted. This study showed that high Mn steel with 3% Cr exhibited the highest resistance to FAC presumably due to the formation of a bi-layer scale structure composed of an inner Cr enriched Fe oxide and an outer Mn substituted partially with Fe oxide on the surface. Although the high Mn steels had the lowest corrosion resistance at the initial corrosion stage due to rapid dissolution kinetics of Mn elements on their surface, the kinetics of inner scale (i.e. Cr enriched Fe oxide) formation on Cr-bearing high Mn steel was faster in dynamic flowing condition compared to stagnant condition. On the other hand, the corrosion scales formed on API X70 and 9% Ni steels did not provide sufficient anti-corrosion function during the prolonged exposure to dynamic flowing conditions.

Inhibition Effect of Nevirapine an Antiretroviral on the Corrosion of Mild Steel Under Acidic Condition

  • Bhat, J. Ishwara;Alva, Vijaya D.P.
    • 대한화학회지
    • /
    • 제55권5호
    • /
    • pp.835-841
    • /
    • 2011
  • Corrosion inhibition of mild steel by nevirapine, an antiretroviral has been investigated using potentiodynamic polarization, electrochemical impedance spectroscopy technique and weight loss methods. The experimental results suggested, nevirapine is a good corrosion inhibitor for mild steel in 1M hydrochloric acid medium and the inhibition efficiency increased with increase in inhibitor concentration. The kinetic parameters for corrosion process and thermodynamic parameters for adsorption process were calculated and discussed. The adsorption of the inhibitor on the surface of mild steel followed Langmuir adsorption isotherm.