• Title/Summary/Keyword: Correlation test

Search Result 12,446, Processing Time 0.041 seconds

Experimental characterization of a smart material via DIC

  • Casciati, Sara;Bortoluzzi, Daniele;Faravelli, Lucia;Rosadini, Luca
    • Smart Structures and Systems
    • /
    • v.30 no.3
    • /
    • pp.255-261
    • /
    • 2022
  • When no extensometer is available in a generic tensile-compression test carried out by a universal testing machine (for instance the model BIONIX from Material Testing Systems (MTS)), the test results only provide the relative displacement between the machine grips. The test does not provide any information on the local behaviour of the material. This contribution presents the potential of an application of Digital Image Correlation (DIC) toward the reconstruction of the behaviour along the specimen. In particular, the authors test a Ni-Ti shape memory alloys (SMA) specimen with emphasis on the coupling of the two measurement techniques.

Reliability and Validity Study of Inertial Sensor-Based Application for Static Balance Measurement

  • Park, Young Jae;Jang, Ho Young;Kim, Kwon Hoi;Hwang, Dong Ki;Lee, Suk Min
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.3
    • /
    • pp.311-320
    • /
    • 2022
  • Objective: To investigate the reliability and validity of static balance measurements using an acceleration sensor and a gyroscope sensor in smart phone inertial sensors. Design: Equivalent control group pretest-posttest. Methods: Subjects were forty five healthy adults aged twenty to fifty-years-old who had no disease that could affect the experiment. After pre-test, all participants wore a waist band with smart phone, and conducted six static balance measurements on the force plate twice for 35 seconds each. To investigate the test-retest reliability of both smart phone inertial sensors, we compared the intra-correlation coefficient (ICC 3, 1) between primary and secondary measurements with the calculated root mean scale-total data. To determine the validity of the two sensors, it was measured simultaneously with force plate, and the comparision was done by Pearson's correlation. Results: The test-retest reliability showed excellent correlation for acceleration sensor, and it also showed excellent to good correlation for gyroscope sensor(p<0.05). The concurrent validity of smartphone inertial sensors showed a mostly poor to fair correlation for tandem-stance and one-leg-stance (p<0.05) and unacceptable correlation for the other postures (p>0.05). The gyroscope sensor showed a fair correlation for most of the RMS-Total data, and the other data also showed poor to fair correlation (p<0.05). Conclusions: The result indicates that both acceleration sensor and gyroscope sensor has good reliability, and that compared to force plate, acceleration sensor has unacceptable or poor correlation, and gyroscope sensor has mostly fair correlation.

Fault detection of logic circuit by use of M-sequence correlation method

  • Miyata, Chikara;Kashiwagi, Hiroshi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10b
    • /
    • pp.24-29
    • /
    • 1993
  • In this paper, the estimation of the structure of a logic circuit under test is made from the observation of the input-output correlation function by use of M-sequence, from which we can estimate whether or not any fault exist in the logic circuit. Especially, investigation was made in case of the 2_stage logic circuit. We checked theoretically the sequence of correlation function, and we have shown that the correlation function is a function of period of M-sequence only, land the appearing number of correlation function in a period is a constant value depending on the logic circuit only. And by computer simulations we have shown that the structure of the circuit under test can be estimated from the observation of sequence of correlation function.

  • PDF

A study on the correlation between V charpy absorbed energy and critical COD value in the welded parts of high tensil strength steel under various welding methods (고장력강 용접부에 있어서 한계 COD값과 V charpy충격치와의 상관성에 관한 연구)

  • 김영식;김충해
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.57-67
    • /
    • 1988
  • Although handicapped by the inability to bridge the size gap between small laboratory sample and large engineering component, the V charpy test sample method does possess certain advantages, such as each of preparation, simplicity of test method, speed, low cost in test machinery, and low cost per test. On the other hand, the COD test method does posses advantages, which reduce the size gap between the laboratory sample and actual engineering component. Consequently, the correlation between V charpy absorbed energy and the critical COD value is required for estimating critical COD value from the simple V charpy test results. In this paper, the high tensile strength steel AH36 plate specimens having a single edge cracked notch were investigated to find out the correlation between V charpy absorbed energy and critical COD value in the welded parts under such various welding methods as shielded metal arc welding, the submerged arc welding and the electro gas welding by means of V charpy impact test and static 3-point bending test. Main results obtained are as follow ; 1. The relationships between V charpy absorbed energy Wc' and critical COD value ($\delta_c$)show; $\delta_c$=0.0065 Wc'+0.1906. 2. Ductile- brittle transition behaviours can be estimated by means of fracture appearance and general yielding behaviours. 3. The V charpy absorbed energy of SMAW is higher than that of SAW, EGW and similar relationships are obtained in the COD tests.

  • PDF

A Study on Correlation Between Accelerated Corrosion Test and Long-term Exposure Test According to the Temperature Condition (온도조건에 따른 철근부식 촉진시험과 장기폭로시험의 상관성에 관한 연구)

  • Park, Sang-Soon;So, Byung-Tak
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.2
    • /
    • pp.203-208
    • /
    • 2016
  • In this study, to clarify the differences rebar corrosion beginning, through the actual corrosion accelerated test in corrosion time and laboratory test chamber of the structure of the marine environment results in both environments, it is an object of correlation coefficient derived. The accelerated corrosion test was carried out by two case, I.e., one is $20^{\circ}C$ of low temperaure codition(case 1), and the other is $65^{\circ}C$ of high temperaute codition(case 2). Whether corroions occurs, it was measures using half-cell potential method. The results indicated that case 2 is to acclerate the corrosion of rebar about 1.7~1.8 times as compared with case 1, thenthe corrosion of rebar embadded in concrete occurred according to the order of OPC60, FA, BS, OPC35. Correlation coefficient between acclerated corrosion test and long-term exposure test, case 1 is 2.45 to 2.94, and case 2 is 4.37~4.99.

Development of The New Instrument for Measuring of Trunk-Hip Forward Flexion (새로운 체전굴 측정 방법의 개발)

  • Lee, Gun-Bum
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.245-257
    • /
    • 2002
  • The purpose of this study was to develop a simple, valid, and reliable instrument for measuring forward flexion of trunk-hip joint. The subject included 44 females for sports major of volunteers at D. Women's University. In establishing the validity, objectivity the reliability of the new flexibility test(NF-test) for trunk-hip joint, Takei- flexometer(modified Leighton flexometer) was administered as the reference instrument, and test-retest method was utilized with the best scores. Intraclass correlation coefficient was obtained to use two way-mixed effect model and this value was average measure. The Pearson product correlation coefficient of L in this study were; the new flexibility test and Takei-flexometer as the reference tool correlated r = .962 in the first test, r = .960 in the second test. The intraclass correlation coefficient of the new flexibility test between in the initial test and in the retest were R = .994 for L, R =.993 for Y, and the intraclass correlation coefficient of the new flexibility test between L and Y were R =.985 in the initial test, and R =.986 in the retest. Based on the above findings, the following conclusions are presented. It was found the new flexibility test (NF test) was a valid, reliable, objective tool for measuring forward flexion of trunk-hip joint, and possible to be recommended as he test for measuring trunk-hip flexibility in the field.

Evaluation of correlation between Strain mudulus (Ev2) and Deformation modulus (ELFWD) Using Cyclic Plate loading Test and LFWD (소형 FWD와 반복평판재하시험에서의 변형계수(Ev2)와의 상관관계 평가)

  • Choi, Chan-Yong;Lee, Sung Hyok;Bae, Jae Hun;Park, Doo Hee
    • Journal of the Korean Geosynthetics Society
    • /
    • v.10 no.3
    • /
    • pp.33-41
    • /
    • 2011
  • In this study, it conducted a compaction quality control test in 29 domestic construction sites and investigated the relationship between classical method (Cyclic Plate bearing test) and LFWD test with subgrade materials which consist in sandy soil and gravelly soil. According to the test results, the most of soil types were mostly satisfied with specification criterion and gravelly soils were easily satisfied with values over 3 times greater than specification criterion. In term of the correlation relation of soil modulus with the two compaction quality control test methods, it is shown that the sandy soil types were a good correlation, while gravelly soil types with a high stiffness materials were indicated less correlation. After the compensation for stress condition, a linear regression for elastic modulus were higher correlation.

A Study on Relationship Between Fear During Pregnancy and Person and Environmental Variables in Pregnant Women (임부의 공포와 개인 및 환경변인의 상오관계에 관한 연구)

  • 정송자
    • Journal of Korean Academy of Nursing
    • /
    • v.4 no.2
    • /
    • pp.131-143
    • /
    • 1974
  • Antenatal care is zoomed toward3 assisting the Individual to achieve safe and wholesome state of health during pregnancy. Nature of fear is assumed to be rooted to complex interaction between past experiences, human relationship and present state of health, however. specific relationship between fear and the variables have not yet been ascertained. This study is designed to investigate the nature of fear of pregnancy, and the correlation between fear and the personal and environmental variables such as personal characteristics past experiences. and psycho-social factors. During the period from October 23 to November 5, 215 pregnant and 104 non-pregnant women of similar chronological are group residing in Seoul were interviewed according to check-list by random General anxiety test, general personality test and test for fear of pregnancy, family according to specific variables such as past experiences of Pregnancy and childbirth, structure of family, family relationship and month of pregnancy was done to the group of pregnant women. To non-pregnant group, general anxiety test was performed to compare with pregnant group. Results of the study are as follows; 1. Hypothesis 1; Degree of general anxiety will be higher e pregnant women compared to that of non-pregnant women. There is no significant difference between the general anxiety of pregnant women and that of non-pregnant women. Therefore, hypothesis I is rejected. 2. Hypothesis 2: Fear of pregnancy and general anxiety will be correlated with personality factors. Through test for fear of pregnancy and general anxiety, a meager contra-correlation between fear and only two personal factors (R and E factor) is revealed but there is no significant correlation between fear and other personal factors (A.S. and T factor). Degree of fear of pregnancy tends to b: higher in the group with low personality factors; responsibility and emotional stability expect the correlation between ascendancy, sociability, and confidence-inferiority. non-significant. Through general anxiety test, level of general anxiety tends to be higher in the group. with low personality factors; responsibility. emotional stability, and confidence except ascendency and sociability, non-significant. Hypothesis 2 is partially supported. 3. Hypothesis 3; General anxiety and fear of pregnancy will be correlated with the past experience-ol pregnancy, and child-birth experience. Though general anxiety test and test for fear of pregnancy, non-significant difference is revealed by P〉.05 level Hypothesis 3 is rejected. 4. Hypothesis 4: General anxiety and fear of pregnancy will be correlated with the month at pregnancy will be correlated with the month of pregnancy. Through tests of general anxiety and fear, significant correlation is revealed degree of fear by-P〈.05 level (CR=1.98) and level of general anxiety by P〈.005 level (CR=3. 11) is higher in the earlier stage of pregnancy. Hypothesis 4 is supported. 5. Hypothesis 5, 6, 7; General anxiety and fear of pregnancy will be correlated with socio-economic status, family structure, and family relationship. Through general anxiety test and tear of pregnancy test, non-significant is revealed by P〉.05 level. Hypothesis 3.6.7 are rejected. Conclusion and recommendation Level of general: anxiety and degree of fear of pregnancy is shown not to be correlated with variables of past experiencers of pregnancy and child-birth. and family factors except the month of - pregnancy. Personal characteristics are shown to be partially contra-correlated meagerly with genera anxiety and fear of pregnancy. This study revealed contrasted results, in regard to presence of correlation between general anxiety and fear of pregnancy to other thesis. In this context. further studies under controlled environment is recommended.

  • PDF

The Study on the Variation of Pass-by-Noise level due to ISO Road (ISO 노면의 Pass-by-Noise Level 편차에 관한 연구)

  • 김기전;배철용;노국희
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.371-376
    • /
    • 2003
  • The objective of this paper is to compare the site-to-site variability of ISO 10844 pass-by-noise test sites. In order to investigate the site-to-site variance of test surfaces, European commercial tires are tested at seven different test sites. Three Korea test sites and four Europe test sites are selected.. The pass by noise test is executed according to a 2001/43/EC regulation. A]though the ISO surface has a very specific track composition, it does not reduce the variation of pass-by-noise measurements over the surface of test sites. This paper shows that the test results of pass-by-noise level are different depending on the test sites. The correlation obtained in this work is able to predict the pass by noise level for certain test site using the data measured from another test site. 17he prediction value is range with an error within 1dB(A).

  • PDF

Modal teat/analysis result correlation of folding fin (접는 날개에 대한 모드시험/해석결과 보정)

  • 양해석
    • Journal of KSNVE
    • /
    • v.6 no.3
    • /
    • pp.305-315
    • /
    • 1996
  • Present paper aims at the correlation of modal characteristics of folding fin between test and analysis using an optimization theory. Folding fin is composed of a movable fin, a base fin, and many functional components related to the folding mechanism. Joint parts of folding fin in FEM are initially modeled as rigid elements resulting some difference between test and analysis in modal characteristics. Therefore, some equivalent springs representing joint parts are introduced to improve the FEM model. The springs were set as design variables, while the frequency difference between test and analysis was set as the object function. Bayesian procedure was ujsed for the minimization.

  • PDF