• Title/Summary/Keyword: Correlation test

Search Result 12,446, Processing Time 0.039 seconds

A Study on Comparison and Analysis of Correlation Test Procedure for a Turbofan and Turboshaft Engine Test Cell (터보팬 및 터보샤프트 엔진 시운전실 Correlation 시험 절차 비교와 분석에 관한 연구)

  • Juhyeon Gwon;Kangmyung Ko
    • Journal of Aerospace System Engineering
    • /
    • v.18 no.1
    • /
    • pp.46-52
    • /
    • 2024
  • Engine test cell should provide controlled test environment to properly verify requirements of engine performance and operational characteristics. However, since test cells cannot be perfectly identical to each other, new test cell requires processes to verify reliability of test results and correct differences through correlation testing using a baseline test cell. This paper studies about what should be considered when correlation testing is performed based on commonalities and differences between turbofan and turboshaft engine. It provides examples of correlation test procedure. In the future, it is expected that this study will help set up a standard that can certify test facility according to engine type.

Evaluation of Soil Properties using Pressuremeter Test (공내재하시험을 이용한 지반정수 평가)

  • 한상연;장서만;전성곤;이종규
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.175-182
    • /
    • 2001
  • The PMT test results are compared with other in situ test such as Standard Penetration Test (SPT), Cone Penetration Test (CPT), Field Vane Test (FVT) and the laboratory test in order to investigate the correlationships for the strength parameters obtained from Busan and Incheon areas. Many proposed correlation formulas also make a comparative study and new correlation formulas for domestic soils are introduced. Limit pressure ( $P_1$) could be determined by P-log($\Delta$V/V) and Relative volume Method. PMT for the granular soils showed relatively high correlation with SPT, while CPT has good correlation with PMT for cohesive soil. The predicted undrained shear test ( $S_{u}$) by the PMT test results for Incheon and Busan samples showed low correlativity with proposed equations, therefore, new correlation formulas are proposed for domestic soils.s.

  • PDF

Correlation between Bilateral Reciprocal Leg Press Test and The Balance in Chronic Stroke Patient (뇌졸중 환자의 양하지 교차밀기 근력 검사와 균형의 상관 관계 연구)

  • Jung, Ji-Hoon;Kim, Joong-Hwi
    • The Journal of Korean Physical Therapy
    • /
    • v.25 no.4
    • /
    • pp.180-186
    • /
    • 2013
  • Purpose: This study was to find a correlation between the bilateral reciprocal leg press test and a the balance in chronic stroke patients. Methods: Eighteen patients performed an isokinetic leg press test consisting of a bilateral reciprocal and unilateral mode. Following the isokinetic leg press testing, subjects performed the balance test: Berg Balance Scale (BBS), Timed Up & Go (TUG) test, and stability limit. Pearson product moment correlation coefficients were used to determine the correlation between the mean score of the isokinetic leg press test, balance test in both affected and non-affected side. Results: This study indicated a significant correlation between the bilateral reciprocal leg press test and stability limit. There were significant correlation between non-affected side bilateral leg press(NBL) and BBS (r=0.501), affected side bilateral leg press (ABL) and non-affected side stability limit(NS) (r=0.614), ABL and total stability limit (TS) (r=0.493), NBL and affected side stability limit(AS) (r=0.480), NBL and NS (r=0.560), NBL and TS (r=0.563), among the patients. Conclusion: Measurement of the lower extremity strength using the bilateral reciprocal leg press test can be used as an evaluating tool of the balance test.

The Reliability and Validity of Figure-of-8 Walk Test in Patients with Stroke (뇌졸중 환자에서 Figure-of-8 walk test의 신뢰도와 타당도)

  • Kim, Yang-Ho;Lim, Jae-Heon
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.10 no.1
    • /
    • pp.29-37
    • /
    • 2012
  • Purpose : The purpose of this study was to establish intra-rater, inter-rater, test-retest reliability, and concurrent validity of figure-of-8 walk test in people with stroke. Methods : The subjects of this study were 17 patients who were diagnosed with a stroke. Subjects were tested twice by the same raters, with 1 day between tests. Subjects were assessed by two physical therapists. Test-retest reliability was calculated using intraclass correlation coefficients (ICC). The concurrent validity was demonstrated by spearman correlation of F8WT with 10m walking test (10MWT), timed up and go test (TUG), Berg balance scale (BBS), dynamic gait index (DGI) and four square step test (FSST). Results : Intra-rater, inter-rater, test- retest of F8WT time, showed high reliability. Intra-rater, inter-rater, test-retest of F8WT steps demonstrated high reliability. Intra-rater, inter-rater, test-retest of F8WT total smoothness score showed below moderate reliability. There was a significant positive correlation of F8WT time with 10MWT, TUG, FSST. There was a significant negative correlation of F8WT time with DGI, BBS. There was a significant positive correlation of F8WT steps with 10MWT, TUG, FSST. There was a significant negative correlation of F8WT steps with DGI. There was a significant positive correlation of F8WT test total smoothness score with BBS. Conclusion : The time, and number of steps in F8WT show high inter, intra-rater, test-retest reliability. The F8WT smoothness shows below moderate reliability. The F8WT shows high concurrent validity with other comparable balance, and walking tests. The F8WT is a valid and reliable measure for assessing walking function in patients with a stroke.

Canonical Correlation: Permutation Tests and Regression

  • Yoo, Jae-Keun;Kim, Hee-Youn;Um, Hye-Yeon
    • Communications for Statistical Applications and Methods
    • /
    • v.19 no.3
    • /
    • pp.471-478
    • /
    • 2012
  • In this paper, we present a permutation test to select the number of pairs of canonical variates in canonical correlation analysis. The existing chi-squared test is known to be limited to normality in use. We compare the existing test with the proposed permutation test and study their asymptotic behaviors through numerical studies. In addition, we connect canonical correlation analysis to regression and we we show that certain inferences in regression can be done through canonical correlation analysis. A regression analysis of real data through canonical correlation analysis is illustrated.

A Detection Scheme for GNSS Repeat-back Jamming Signal Using Correlation Ratio Test Metric of C-PRN Signal (통합의사잡음 신호의 상관비 실험을 이용한 GNSS 재방송재밍 신호 검출기법)

  • Yoo, Seungsoo;Yeom, Dong-Jin;Jee, Gyu-In;Kim, Sun Yong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.8
    • /
    • pp.665-670
    • /
    • 2016
  • This paper proposes a repeat-back jamming signal detection scheme using a correlation ratio test metric of a combined pseudo-random noise signal for global navigation satellite systems. The correlation ratio test metric allows for the monitoring of possible distortions in the signal correlation. The proposed scheme is a modified version of the correlation ratio test metric to detect a repeat-back jamming signal in a multipath environment. Through a Monte-Carlo simulation, it is confirmed that the proposed scheme detects almost the whole case, which is received a repeat-back jamming signal under the 6 dB jamming to signal power ratio.

Correlation between Colon Transit Time Test Value and Initial Maintenance Dose of Laxative in Children with Chronic Functional Constipation

  • Kim, Mock Ryeon;Park, Hye Won;Son, Jae Sung;Lee, Ran;Bae, Sun Hwan
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.19 no.3
    • /
    • pp.186-192
    • /
    • 2016
  • Purpose: To evaluate the correlation between colon transit time (CTT) test value and initial maintenance dose of polyethylene glycol (PEG) 4000 or lactulose. Methods: Of 415 children with chronic functional constipation, 190 were enrolled based on exclusion criteria using the CTT test, defecation diary, and clinical chart. The CTT test was performed with prior disimpaction. The laxative dose for maintenance was determined on the basis of the defecation diary and clinical chart. The Shapiro-Wilk test and Pearson's and Spearman's correlations were used for statistical analysis. Results: The overall group median value and interquartile range of the CTT test was 43.8 (31.8) hours. The average PEG 4000 dose for maintenance in the overall group was $0.68{\pm}0.18g/kg/d$; according to age, the dose was $0.73{\pm}0.16g/kg/d$ (<8 years), $0.53{\pm}0.12g/kg/d$ (8 to <12 years), and $0.36{\pm}0.05g/kg/d$ (12 to 15 years). The dose of lactulose was $1.99{\pm}0.43mL/kg/d$ (<8 years) or $1.26{\pm}0.25mL/kg/d$ (8 to <12 years). There was no significant correlation between CTT test value and initial dose of laxative, irrespective of the subgroup (encopresis, abnormal CTT test subtype) for either laxative. Even in the largest group (overall, n=109, younger than 8 years and on PEG 4000), the correlation was weak (Pearson's correlation coefficient [R]=0.268, p=0.005). Within the abnormal transit group, subgroup (n=73, younger than 8 years and on PEG 4000) correlation was weak (R=0.267, p=0.022). Conclusion: CTT test value cannot predict the initial maintenance dose of PEG 4000 or lactulose with linear correlation.

A Study on The Compressive Strength Correlation by Various Nondestructive Test Method (각종 비파괴 검사법에 의한 압축강도 상관연구)

  • 최원호;신도철;이대우
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10b
    • /
    • pp.767-772
    • /
    • 1998
  • schumidt hammer and ultra-sonic method are commonly used for concrete compressive strength test in a construction field. At present, various kinds of equations for estimation of strength are present, which have been used in a construction field. The purpose of this study is to evaluate the correlation between estimation strength by presentation equations and destructive strength to test specimen, and find out which is a suitable equation for this construction site. In this study, a strength test was carried out destructive test by means of core sampling. Non destructive test was conducted Schumidt hammer and ultra-sonic method, the experimental parameter were concrete age, test method and strength level. It is demonstrated that the correlation behavior of concrete strength in this study good due to the performs analysis of correlation between core strength and nondestructive strength.

  • PDF

A Study of Correlation between Electromyography(EMG) and the Heart Rate Variability(HRV) Test, and Their Role as Predicting Factors for Peripheral Facial Palsy Prognosis (말초성 안면신경마비 환자에서 EMG(Electromyography)와 HRV(Heart Rate Variability)의 임상적 예후인자로서의 유용성 및 상관성 연구)

  • Kim, Chan-Young;Kim, Jong-In;Lee, Sang-Hoon;Park, Dong-Suk;Koh, Hyung-Kyun
    • Journal of Acupuncture Research
    • /
    • v.25 no.2
    • /
    • pp.189-197
    • /
    • 2008
  • Objectives : This study was performed in order to investigate the effectiveness of electromyography and the Heart Rate Variability(HRV) test as prognosis factors, and to clarify correlation between Electromyography and the Heart Rate Variability test. Methods : 44 Bell's palsy patients who were graded V on the House-Brackmann scale and underwent HRV and EMG testing were retrospectively reviewed based on medical records. Results from both tests were analyzed via simple linear regression, and bivariate correlation analysis was performed to investigate the correlation between results from the two tests. The severity of the facial palsy at onset and at 2 weeks after treatment were evaluated with the H-B grade and Yanagihara grading system, and was converted into improvement scores. Results : Mean axonal loss according to electromyography showed a statistically significant correlation in predicting peripheral facial palsy improvement(p<0.01). HR, SDNN, TP, LF, HF, VLF, and LF/HF ratio on the Heart Rate Variability test showed no significant correlation in predicting peripheral facial palsy improvement. Mean axonal loss determined by electromyography, and HR, SDNN, TP, LF, HF, VLF, and LF/HF ratio recorded with the Heart Rate Variability test was analyzed with the bivariate correlation analysis method. Mean axonal loss and SDNN showed a statistically significant correlation(p<0.01) Conclusions : The Heart Rate Variability test has no statistical significance in predicting peripheral facial palsy improvement. SDNN has a statistically significant correlation with mean axonal loss as determined by electromyography.

  • PDF

Correlation of single leg vertical jump, single leg hop, and single leg squat distances in healthy persons

  • Shin, Seung-Ho;Woo, Hyunjae
    • Physical Therapy Rehabilitation Science
    • /
    • v.2 no.1
    • /
    • pp.57-61
    • /
    • 2013
  • Objective: To determine the correlation among three functional tests: single leg vertical jump (SLVJ), single leg hop for distance (SLHD), and single leg squat (SLSQ). Design: Cross sectional study. Methods: Twenty healthy men (n=10) and women (n=10) with no history of lower extremity dysfucntion participated in this study and performed in university research laboratory. The procedures consisted of a general warm-up, a task-specific warm-up, actual testing, and a cool down. All participants performed the three tests in random order. Each test was performed three times for the dominant and non-dominant lower extremity (LE). SLVJ, SLHD, SLSQ were measured using a standard tape measure. Results: Statistically significant difference was presented between dominant LE and non-dominant LE in each function test (p<0.05). The strongest correlation was between SLVJ and SLSQ, 0.939 and 0.883 for dominant and non-dominant LE, respectively (p<0.05). The weakest correlation was between SLVJ and SLHD, 0.713 for dominant (p<0.05) and between SLSQ and SLHD, 0.739 for non-dominant (p<0.05). Conclusions: There is a strong correlation between SLVJ and SLSQ, suggesting that each test measures similar constructs of function and can be substitutive, while weak correlation between SLSQ and SLHD suggest these two tests do not measure the same functional components and could be paired as outcome measures for the clinical assessment of LE function. It will provide physical therapist with scientific evidence for effective test combination of LE function assessment in clinical practice.

  • PDF