• Title/Summary/Keyword: Correlation Interference

Search Result 348, Processing Time 0.033 seconds

Data Transmission Rate Improvement Scheme in Power Line Communication System for Smart Grid (스마트 그리드를 위한 전력선 통신 시스템에서의 데이터 전송률 향상 기법)

  • Kim, Yo-Cheol;Bae, Jung-Nam;Kim, Yoon-Hyun;Kim, Jin-Young
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.12B
    • /
    • pp.1183-1191
    • /
    • 2010
  • In this paper, I propose an adaptive OFDM CP length algorithm for in PLC systems for smart grid. The proposed scheme calculates the channel delay information at the CP controller of the receiver by taking correlation between a received data frame and the following delayed one. The CP controller, immediately, feeds back the channel delay information to the transmitter. Then, the transmitter adapts CP length for next data frame. As an impulsive noise model, Middleton Class A interference model was employed. The performance is evaluated in terms of packet data rate, cumulative packet data rate, and bit error rate (BER). The simulation results showed data gain (which is the amount of the reduced bits) gets larger as the number of packets increase, but the amount of data gain reduced as the number of branches ($N_{br}$) increase. In respects of BER for the cases $N_{br}$ is 3, 4, and 5, performance of the adaptive CP length algorithm and the fixed CP scheme are similar. Therefore, it is confirmed the proposed scheme achieved data rate increment without BER performance reduction compared to the conventional fixed CP length scheme.

Validated HPLC Method for the Pharmacokinetic Study of Atenolol and Chlorthalidone Combination Therapy in Korean Subjects

  • Kang, Hyun-Ah;Kim, Hwan-Ho;Kim, Se-Mi;Yoon, Hwa;Cho, Hea-Young;Oh, Seaung-Youl;Choi, Hoo-Kyun;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.5
    • /
    • pp.331-338
    • /
    • 2006
  • A rapid, selective and sensitive reverse-phase HPLC methods for the determination of atenolol and chlorthalidone in human serum and whole blood were validated, and applied to the pharmacokinetic study of atenolol and chlorthalidone combination therapy. Atenolol and an internal standard, pindolol, were extracted from human serum by liquid-liquid extraction, and analyzed on a $\mu$-Bondapak C18 $10-{\mu}$ column in a mobile phase of methanol-0.01 M potassium dihydrogenphosphate(30:70, v/v, adjusted to pH 3.5) and fluorescence detection(emission: 300 nm, excitation: 224 nm). Chlorthalidone and an internal standard, probenecid, were extracted form human whole blood by liquid-liquid extraction, and analyzed on a Luna C18 $5-{\mu}$ column in a mobile phase of acetonitrile containing 77% 0.01 M sodium acetate and UV detection at 214 nm. These analysis were performed at three different laboratories using the same quality control(QC) samples. The chromatograms showed good resolution, sensitivity, and no interference by human serum and whole blood, respectively. The methods showed linear responses over a concentration range of 10-1,000 ng/mL for atenolol and 0.05-20 ${\mu}g/mL$ for chlorthalidone, with correlation coefficients of greater than 0.999 at all the three laboratories. Intra- and inter-day assay precision and accuracy fulfilled international requirements. Stability studies(freeze-thaw, short-, long-term, extracted sample and stock solution) showed that atenolol and chlorthalidone were stable. The lower limit of quantitation of atenolol and chlorthalidone were 10 ng/mL and 0.05 ${\mu}g/mL$, respectively, which was sensitive enough for pharmacokinetic studies. These methods were applied to the pharmacokinetic study of atenolol and chlorthalidone in human volunteers following a single oral administration of Hyundai $Tenoretic^{\circledR}$ tablet(atenolol 50 mg and chlorthalidone 12.5 mg) at three different laboratories.

Electrochemical determination of chloramphenicol using a glassy carbon electrode modified with dendrite-like Fe3O4 nanoparticles

  • Giribabu, Krishnan;Jang, Sung-Chan;Haldorai, Yuvaraj;Rethinasabapathy, Muruganantham;Oh, Seo Yeong;Rengaraj, Arunkumar;Han, Young-Kyu;Cho, Wan-Seob;Roh, Changhyun;Huh, Yun Suk
    • Carbon letters
    • /
    • v.23
    • /
    • pp.38-47
    • /
    • 2017
  • In this study, magnetite ($Fe_3O_4$) nanoparticles were electrochemically synthesized in an aqueous electrolyte at a given potential of -1.3 V for 180 s. Scanning electron microscopy revealed that dendrite-like $Fe_3O_4$ nanoparticles with a mean size of < 80 nm were electrodeposited on a glassy carbon electrode (GCE). The $Fe_3O_4/GCE$ was utilized for sensing chloramphenicol (CAP) by cyclic voltammetry and square wave voltammetry. A reduction peak of CAP at the $Fe_3O_4/GCE$ was observed at 0.62 V, whereas the uncoated GCE exhibited a very small response compared to that of the $Fe_3O_4/GCE$. The electrocatalytic ability of $Fe_3O_4$ was mainly attributed to the formation of Fe(VI) during the anodic scan, and its reduction to Fe(III) on the cathodic scan facilitated the sensing of CAP. The effects of pH and scan rate were measured to determine the optimum conditions at which the $Fe_3O_4/GCE$ exhibited the highest sensitivity with a lower detection limit. The reduction current for CAP was proportional to its concentration under optimized conditions in a range of $0.09-47{\mu}M$ with a correlation coefficient of 0.9919 and a limit of detection of $0.09{\mu}M$ (S/N=3). Moreover, the fabricated sensor exhibited anti-interference ability towards 4-nitrophenol, thiamphenicol, and 4-nitrobenzamide. The developed electrochemical sensor is a cost effective, reliable, and straightforward approach for the electrochemical determination of CAP in real time applications.

An Efficient Coding Technique of Holographic Video Signal using 3D Segment Scanning (분할영역의 3차원 스캐닝을 이용한 홀로그래픽 비디오 신호의 효율적인 부호화 기술)

  • Seo, Young-Ho;Choi, Hyun-Jun;Kim, Dong-Wook
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.2C
    • /
    • pp.132-140
    • /
    • 2007
  • In this paper, we proposed a new technique to encode and decode the digital hologram. Since the digital hologram (or fringe pattern) is generated by interference of light, it has much different property from natural 2D (2 dimensional) images. First, we acquisite optical-sensed or computer-generated hologram by digital type, and then extract a chrominance component. The extracted digital hologram for coding is separated into segments to use multi-view properties. The segmented hologram shows the similar characteristics with picturing an object with 2D cameras in various point of view. Since fringe pattern is visually observed like as noise, we expect that the fringe pattern has poor coding efficiency. To obtain high efficiency, the segment is transformed with DCT (Discrete Cosine Transform) which resembles hologram generation process with high performance. Each transformed segment passes the 3D scanning process according to time and spatial correlation, and is organized into a video stream. Since the segment which correspond to frame of a video stream consists of the transformed coefficients with wide range of value, it is classified and re-normalized. Finally it is compressed with coding tools. The proposed algorithm illustrated that it has better properties for reconstruction of 16 times higher compression rate than the previous researches.

Comparison of SqueeSAR Analysis Method And Level Surveying for Subsidence Monitoring at Landfill Site (매립지 지반침하 모니터링을 위한 SqueeSAR 해석법과 수준측량의 비교)

  • Kim, Dal-Joo;Lee, Yong-Chang
    • Journal of Cadastre & Land InformatiX
    • /
    • v.48 no.2
    • /
    • pp.137-151
    • /
    • 2018
  • Recently, National interest has been rising due to earthquakes in Gyeongju and Pohang, disasters caused by landslides, landslides, and sinkholes around construction sites, and damage caused by disasters. SAR is able to detect ground displacement in mm for wide area, collect data through satellite, predict timeliness of crustal change by time series analysis, and reduce disaster and disaster damage. The purpose of this study is to investigate the latest SAR interference analysis technique (SqueeSAR analysis technique) of Sentinel-1A satellite (SAR sensor) of European ESA for about 3 years by selecting the 1st landfill site in the metropolitan area in Incheon, The settlement amount was calculated in a time series. Especially, in order to examine the accuracy of the subsidence and subsidence tendency by the SqueeSAR analysis method, the ground level survey was compared and analyzed for the first time in Korea. Also, the tendency of the subsidence trend was predicted by analyzing the time series and correlation trend of the subsidence for three years. Through this study, it is expected that disaster prevention and disaster prevention such as sinkhole and landslide can be utilized from time series monitoring of crustal variation of the land.

Determination of lercanidipine in human plasma by LC-MS/MS (LC-MS/MS를 이용한 혈장 중 레르카니디핀의 분석)

  • Jang, Moon-Sun;La, Sookie;Chang, Kyu Young;Kang, Seung Woo;Han, Sang Beom;Lee, Kyung Ryul;Lee, Hee Joo
    • Analytical Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.34-40
    • /
    • 2008
  • Liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the quantitative determination of lercanidipine in human plasma. After addition of internal standard (amlodipine), plasma was precipitated with acetonitrile and the supernatant was evaporated. The residues were dissolved in 50 % acetonitrile and analyzed by LC-MS/MS. Using MS/MS with multiple reaction monitoring(MRM) mode, lercanindipine were selectively detected without severe interference from human plasma. The standard calibration curve for lercanidipine was linear (r = 0.9994) over the concentration range 0.05-20.0 ng/mL in human plasma. The intra- and inter-day precision over the concentration range of lercanidipine was lower than 11.7 % (correlation of variance, CV), and accuracy was between 94.4-114.8 %. This method has been successfully applied to the pharmacokinetic study of lercanidipine in human plasma.

Vegetation Structure and Main Characteristics in Habitat of Sarcodon impricatus (향버섯 발생지의 식생구조 및 주요 특성)

  • Mi-Ji Lee;Nam-In Koo;Kang-Hyeon Ka;Min-Su Kim
    • Korean Journal of Environment and Ecology
    • /
    • v.38 no.2
    • /
    • pp.156-168
    • /
    • 2024
  • This study was carried out to provide fundamental data for forest land and the environment by investigating the vegetation structure and soil properties of forest land where Sarcodon impricatus are present. The study area was divided into the Quercus mongolica community, dominated by Q. mongolica and the Quercus variabilis community, a mixed forest with Q. variabilis, Q. mongolica and Pinus densiflora. Also, Calamagrostis arundinacea in the former community and Disporum smilacinum and Carex siderosticta in the latter community showed significant levels as indicator species. Both communities showed a strong correlation between available phosphate and pH, sand, and clay, and the high organic matter content and slightly acidic pH of the soil are believed to be related to the development of S. impricatus. The species appearing at the lower layer continue to dominate because the species appearing at the upper layer have secured realized niches. The site was distributed in a relatively humid place in a north-east direction, and soil was developed with a thin litter layer and low rock exposure. In the selected S. impricatus growing areas, vegetation centered on highly adaptable species to disturbance or external interference was developed. Therefore, it is expected to be used as fundamental data to promote the occurrence of S. impricatus during artificial cultivation, as it is possible to identify the stand where S. impricatus occurs indirectly.

Investigation of an Acceptable Hemolysis Index Using Re-collected Samples (재채혈된 검체를 이용한 허용 Hemolysis Index에 대한 연구)

  • Hong Bum KIM;Dong Il WON;Kyoung Ae SON;Jin Man KIM;Yu Jin WOO
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.56 no.1
    • /
    • pp.32-42
    • /
    • 2024
  • This study compared the results of hemolyzed samples and re-collected samples to investigate a hemolysis influence and an acceptable hemolysis index (HI). Before and after hemolysis, alkaline phosphatase (ALP), aspartate aminotransferase (AST), alanine aminotransferase (ALT), amylase (Amy), direct bilirubin (D-bil), total bilirubin (T-bil), creatine phosphokinase (CK), gamma glutamyl transferase (GGT), iron, potassium (K), lactate dehydrogenase (LDH), magnesium (Mg), phosphorus (Phos), total protein (TP), and uric acid (UA) showed significant results in the paired t-test. LDH, K, iron, AST, CK, GGT, TP, Amy and Phos had a high correlation between the degree of hemolysis and the results of samples. When comparing Roche's cut-off HI with HIQChigh obtained using quality control (QC) high standard deviation (SD), AST, D-bil, CK, and LDH were similar, but Amy, GGT, K, iron, Phos, and TP were lower than the cut-off HI of Roche, while ALP and ALT were higher. Some analytes which showed no significant results in the paired t-test, were found to have significant results in HI>200. Hence, it is suggested that the hemolyzed sample should be rejected if HI>200. Based on this study that some analytes were affected when HI<100, we recommend to set the standard of hemolysis starting from HI>50.

Relationship between Insomnia and Depression in Type 2 Diabetics (2형 당뇨병 환자에서 불면증과 우울 증상의 관련성)

  • Lee, Jin Hwan;Cheon, Jin Sook;Choi, Young Sik;Kim, Ho Chan;Oh, Byoung Hoon
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.27 no.1
    • /
    • pp.50-59
    • /
    • 2019
  • Objectives : Many of the patients with type 2 diabetes are associated with sleep problems, and the rate of insomnia is known to be higher in the general population. The aims of this study were to know the frequency and clnical characteristics of insomnia, and related variables to insomnia in patients diagnosed with type 2 diabetes. Methods : For 99 patients from 18 to 80 years of age (65 males and 34 females) with type 2 diabetes, interviews were performed. Total sleep time and sleep latency was evaluated. Insomnia was evaluated using the Korean Version of the Insomnia Severity Index (ISI-K). Severity of depressive symptoms were evaluted using the Korean version of the Hamilton Depression Scale (K-HDRM). According to the cutoff score of 15.5 on the ISI-K, subjects were divided into the group of type 2 diabetics with insomnia (N=34) and those without insomnia (N=65) at first, and then statistically analyzed. Results : TInsomnia could be found in 34.34% of type 2 diabetics. Type 2 diabetics with insomnia had significantly more single or divorced (respectively 11.8%, p<0.05), higher total scores of the K-HDRS ($11.76{\pm}5.52$, p<0.001), shorter total sleep time ($5.35{\pm}2.00hours$, p<0.001), and longer sleep latency ($50.29{\pm}33.80minutes$, p<0.001). The all item scores of the ISI-K in type 2 diabetics with insomnia were significantly higher than those in type 2 diabetics without insomnia, that is, total ($18.38{\pm}2.69$), A1 (Initial insomnia) ($2.97{\pm}0.76$), A2 (Middle insomnia) ($3.06{\pm}0.69$), A3 (Terminal insomnia) ($2.76{\pm}0.61$), B (Satisfaction) ($3.18{\pm}0.72$), C (Interference) ($2.09{\pm}0.97$), D (Noticeability) ($2.12{\pm}1.09$) and E (Distress) ($2.21{\pm}0.81$) (respectively p<0.001). Variables associated with insomnia in type 2 diabetics were as following. Age had significant negative correlation with A3 items of the ISI-K (${\beta}=-0.241$, p<0.05). Total scores of the K-HDRS had significant positive correlation, while total sleep time had significant negative correlation with all items of the ISI-K (respectively p<0.05). Sleep latency had significant positive correlation with total,, A1, B and E item scores of the ISI-K (respectively p<0.05). Conclusions : Insomnia was found in about 1/3 of type 2 diabetics. According to the presence of insomnia, clinical characteristics including sleep quality as well as quantity seemed to be different. Because depression seemed to be correlated with insomnia, clinicians should pay attention to early detection and intervention of depression among type 2 diabetics.

Development of Extracting Solution for Soil Chemical Analysis Suitable to Integrated Ion-selective Micro-electrodes (집적형 이온선택성 미세전극 센서에 적합한 토양화학 분석용 침출액 종 개발)

  • Shin, Kook-Sik;Lim, Woo-Jin;Lee, Sang Eun;Lee, Jae Seon;Cha, Geun Sig
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.42 no.6
    • /
    • pp.513-521
    • /
    • 2009
  • The primary goal of this research was to develop an optimized analytical procedure for soil analysis based on ion-selective microelectrodes for agricultural purposes, which can perform on-site measurement of various ions in soil easily and rapidly. For the simple and rapid on-site diagnosis, an analysis of soil chemicals was performed employing a multicomponent-in-situ-extractant and an evaluation of ionselective microelectrodes were conducted through the regressive correlation method with a standard analytical approach widely employed in this area. Examination of sensor responses between various soil nutrient extractants revealed that 0.01M HCl and 1M LiCl provided the most ideal Nernstian response. However, 1M LiCl deteriorated the selective response for analytes due to high concentration (1M) of lithium cation. Thus, employing either 0.1M HCl as an extractant followed by 10 times dilution, or 0.01M HCl as an extractant without further dilution was chosen as the optimal extractant composition. A study of regressive correlation between results from ion-selective microelectrodes and those from the standard analytical procedure showed that analyses of $K^+$, $Na^+$, $Ca^{2+}$, and $NO_3{^-}$ showed the excellent consistency between two methods. However, the response for $NH_4{^+}$ suffered the severe interference from $K^+$. In addition, the selectivity for $Mg^{2+}$ over $Ca^{2+}$ was not sufficient enough since available ionophores developed so far do not provide such a high selectivity for $Mg^{2+}$. Therefore, as an agricultural on-site diagnostic instrument, the device in development requires further research on $NH_4{^+}$ analysis in the soil sample, development of $Mg^{2+}$-selective ionophore, and more detailed study focused on potassium, one of the most important plant nutrients.