• Title/Summary/Keyword: Correlation Interference

Search Result 349, Processing Time 0.031 seconds

Haematococcus pluvialis Cell-Mass Sensing Using Ultraviolet Fluorescence Spectroscopy

  • Lababpour, Abdolmajid;Hong, Seong-Joo;Lee, Choul-Gyun
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.12
    • /
    • pp.1922-1929
    • /
    • 2007
  • A simple whole-cell-based sensing system is proposed for determining the cell mass of H. pluvialis using ultraviolet fluorescence spectroscopy. An emission signal at 368 nm was used to detect the various kinds of green, green-brown, brown-red, and red H. pluvialis cells. The fluorescence emission intensities of the cells were highest at 368 nm with an excitation wavelength of 227 nm. An excitation wavelength of 227 nm was then selected for cell-mass sensing, as the emission fluorescence intensities of the cell suspensions were highest at this wavelength after subtracting the background interference. The emission fluorescence intensities of HPLC-grade water, filtered water, and HPLC-grade water containing a modified Bold's basal medium (MBBM) were measured and the difference was less than 1.6 for the selected wavelengths. Moreover, there was no difference in the emission intensity at 368 nm among suspensions of the various morphological states of the cells. A calibration curve of the fluorescence emission intensities. and cell mass was obtained with a high correlation ($R^2=0.9938$) for the various morphological forms of H. pluvialis. Accordingly, the proposed method showed no significant dependency on the various morphological cell forms, making it applicable for cell-mass measurement. A high correlation was found between the fluorescence emission intensities and the dry cell weight with a mixture of green, green-brown, brown-red, and red cells. In conclusion, the proposed model can be directly used for cell-mass sensing without any pretreatment and has potential use as a noninvasive method for the online determination of algal biomass.

The Relationship between Nursing Performance and Leadership Styles of Head Nurses (수간호사의 리더십 유형과 간호사의 직무만족과의 관계 연구)

  • Min, Soon;Kim, Hyun-Sook;Oh, Song-Ja
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.6 no.1
    • /
    • pp.31-54
    • /
    • 2000
  • This study was aimed for effective nursing performance of the nurse to be able dedicate to the development of professional nursing work by understanding correlation between the leadership style of head nurse and the nursing performance of the nurse. The materials have been collected through structured questionnaires for 18 days from Feb. 2, 1999 to Feb. 20 from 234 nurses presently working at 4 hospitals Circumstances aptitude theory of Fleishman (1973) were used as the device of measuring leadership style, and staff nurses nursing performance were done by head nurses utilizing questionnaire adopted from Park. Data was analyzed by frequency, mean, ANOVA, ANCOVA, and Pearson's correlation coefficiency by using SPSS program. The results are as follows ; 1. Head nurse leadership was classified in the following manner : duty and human relationships oriented style of head nurse leadership(3.76), human relationship oriented style(3.30), duty leadership oriented style(3.12), and non-interference leadership style(2.77). Duty and human relationships showed highest score in this category. 2. The mean of nursing performance was 3.66, dependent nursing duty was 3.88, interpersonal relationship 3.78, and independent nursing was 3.34. 3. An education course of nursing performance by general characteristics was statistically significant. Job satisfaction, for seen working periods, and motivation for choosing a nursing job of nursing job characteristics was statistically siginficant. 4. As the degree of independence nursing performance increases, the degree and of dependance and interpersonal relationship of nursing performance increases. 5. The relationship between nurse leadership style and nursing performance were statistically different. The degree of duty and human relationship style of the head nurse were highest in dependent and independent nursing performance. Therefore, it is desirable that the head nurse should demonstrate the leadership style high in the duty and human relationships for effective nursing performance.

  • PDF

A Study on Range-Doppler Processing of Time Shifted LFM Signals based on Quasi Orthogonal Property (준 독립적 특성 기반의 시간이동 LFM 신호를 이용한 거리-도플러 처리에 대한 연구)

  • Suh, Kyoung-Whoan
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.6
    • /
    • pp.125-133
    • /
    • 2016
  • As one of solutions to pursue the efficient use of spectrum resource, we proposed the methodology for the co-channel multi-site radar operations with the synchronous GPS clock. The proposed algorithm, based on a quasi orthogonal property, find a candidate set of the time shifted linear frequency modulation(TSLFM) signals with the minimum acceptable level of the correlation among selected TSLFM signals. To check suggested algorithm, numerical analysis for several radars operating in the same channel with a sawtooth waveform has been performed by using range-Doppler processing for the given system parameters, and computational results are presented and examined in terms of range profile and doppler shift for a targets with velocity and distance. Simulated results have a good agreement with assumed target distance and its velocity, within the error of resolution.

Performance Analysis of a Receiver for WCDMA Systems (광대역 코드분할 다중화 시스템 수신기의 성능 분석)

  • 박중후
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.6
    • /
    • pp.87-93
    • /
    • 2001
  • As a new type of a linear decorrelating receiver, the Pseudo-Decorrelator was presented for asynchronous code division multiple access systems by the author. In this paper, the concept of the Pseudo-Decorrelator is extended to derive a receiver for WCDMA uplink systems over an additive white Gaussian noise channel. Starting with the analysis of the multiple access components of the decision statistics, a non-square cross-correlation matrix for each bit is obtained. This cross-correlation matrix is then inverted, and the inverted matrix is applied to the decision statistics obtained from a conventional receiver. In this receiver, the detection process can be started after the first three consecutive bits are received. Simulation results are presented for K-user systems over an additive white Gaussian noise channel under the circumstances in which synchronization errors, including time delay errors and carrier phase errors exist. It is shown that the proposed receiver performs better than a conventional receiver and parallel interference canceller.

  • PDF

A Position Revision Method by Path-Loss Factor in GIS based Wireless Sensor Node Deployments (GIS기반 무선 센서노드 배치에서 경로손실을 고려한 위치 보정 방법)

  • Bae, Myung-Nam;Kwon, Hyuk-Jong;Kang, Jin-A;Lee, In-Hwan
    • Spatial Information Research
    • /
    • v.19 no.6
    • /
    • pp.111-121
    • /
    • 2011
  • In this paper, we proposes a sensor node positioning algorithm that utilizes the geo-spatial elements and considers the factors to represent the propagation loss generated by the various obstacles in the urban wireless environments. First, we measures the propagation loss about the radio frequencies in major road of the urban, and defines the correlation between the measured loss and the environment information for the road and its surrounding get from Urban GIS. Secondly, through the utilization of the loss-environment correlation, we describes the detailed instruction for requiring the radio coverage decision and deploy system implementation for the wireless sensor node in urban. By the consideration of interference factor by the building and the linear structure of road, we can evaluate the path loss below 5dB RMS error. And, we proposes the way to revise the sensor node deployment based on the corelation and the measured path loss.

Evaluation of Odor Dispersion from Livestock Building through Field Experiment (현장실험을 통한 축산시설로부터 배출되는 축산악취의 확산 평가)

  • Yeo, Uk-Hyeon;Lee, In-Bok;Ha, Tae-Hwan;Decano, Cristina;Kim, Rack-Woo;Lee, Sang-Yeon;Kim, Jun-Gyu;Choi, Young-Bae;Park, You-Me
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.6
    • /
    • pp.21-30
    • /
    • 2019
  • Livestock odor is comprised of mixed type of odorous compounds. Among these, ammonia ($NH_3$) and hydrogen sulfide ($H_2S$) are the two known major odor causing substances. Because high odor concentration reduces productivity of livestock and causes damage to the surrounding communities, quantitative analysis is needed to manage the odor inside and outside the livestock facilities. It is also necessary to evaluate odor dispersion according to the distance between the receptors taking into account the influence of odor source and weather condition. Therefore, in this study, we tried to evaluate the internal environment and odor dispersion from experimental pig house considering weather conditions. An experimental farm was specifically selected to eliminate the interference of odors generated by adjacent farms. $NH_3$ and complex odor were quantitatively analyzed using a gas detector and air dilution sensory method. The concentration of $NH_3$ and complex odor in pig house showed a distinct concentration difference according to the cleaning and ventilation conditions. $NH_3$ concentration and complex odor was lower than emission standard in the pig house and at the site boundary. The average $NH_3$ concentration (P1~P3) and the $NH_3$ concentration at the site boundary (S1) were strongly correlated with R=0.77. While the correlation for complex odor inside and at the site boundary had R=0.52. The correlation coefficient between $NH_3$ and the complex odor was 0.80.

Correlation Analysis between BLE-based RSSI and SoC Internal or Local Temperature (BLE 기반 RSSI와 SoC 내부 또는 국부 온도의 상관관계)

  • Kim, Seong-Chang;Lee, Min-Jeong;Oh, Sung-Bhin;Kim, Jun-Su;Kim, Jin-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.89-91
    • /
    • 2022
  • Wireless sensor networks(WSN), which are mainly used for indoor positioning, rely on the accuracy of RSSI. This RSSI is sensitive to several factors that cause interference, and there are foreign studies showing that temperature has a large effect on RSSI in indoor/outdoor environment among several factors. The temperature of the indoor space is uneven due to heat sources or air cooling systems indoors, and temperature changes frequently occur at certain locations. In particular, in case of an indoor fire, the accurate positioning system is required to guide an evacuation route, but a high temperature is locally formed due to a fire around the receiver, so the RSSI value could be influenced. In this paper, the effect on RSSI is studied by analyzing the correlation between SoC internal/local temperature and RSSI.

  • PDF

Evaluation of Detection Ability of a Quantitative Light-Induced Fluorescence Digital Device for Initial Secondary Caries Lesion (Quantitative Light-Induced Fluorescence-Digital을 이용한 와동 내벽의 초기 이차우식병소 탐지 능력 평가)

  • Kim, Young Seok
    • Journal of dental hygiene science
    • /
    • v.17 no.2
    • /
    • pp.116-122
    • /
    • 2017
  • The purpose of this study was to evaluate the detection ability of secondary caries using qunatitative light-induce fluorescence-digital (QLF-D) device. Twenty bovine teeth with cavity on surface were demineralized during 21 days for secondary caries lesion of cavity wall. After 21 days, cavity was filled using composite resin and cut the specimen in half with disc. Fluorescence loss of lesion on surface by time flow, cross sectional lesion, and lesion of filled or unfilled surface were analyzed using analysis software. ${\Delta}F$ (value of fluorescence loss) of the lesion on surface assessed by the QLF-D increased significantly over time up to 21 days. And ${\Delta}F$ value of lesion of filled surface is significantly lower than that of unfilled surface (p<0.001). ${\Delta}F$ of filled surface is 1.31 times of cross section lesion. The correlation of between ${\Delta}F$ of filled surface lesion and ${\Delta}F$ of cross section lesion was showed low agreement (0.026) and correlation of between ${\Delta}F$ of unfilled surface lesion and ${\Delta}F$ of cross section lesion was showed high agreement (0.613). In conclusion, secondary caries can be detected on surface using QLF-D. However, interference of fluorescence of filling material is the points to be especially considered for exact analysis of secondary caries lesion.

Application of Digital Signal Analysis Technique to Enhance the Quality of Tracer Gas Measurements in IAQ Model Tests

  • Lee, Hee-Kwan;Awbi, Hazim B.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.E2
    • /
    • pp.66-73
    • /
    • 2007
  • The introduction of tracer gas techniques to ventilation studies in indoor environments provides valuable information that used to be unattainable from conventional testing environments. Data acquisition systems (DASs) containing analogue-to-digital (A/D) converters are usually used to function the key role that records signals to storage in digital format. In the testing process, there exist a number of components in the measuring equipment which may produce system-based inference to the monitored results. These unwanted fluctuations may cause significant error in data analysis, especially when non-linear algorithms are involved. In this study, a pre-processor is developed and applied to separate the unwanted fluctuations (noise or interference) in raw measurements and to reduce the uncertainty in the measurement. Moving average, notch filter, FIR (Finite Impulse Response) filters, and IIR (Infinite Impulse Response) filters are designed and applied to collect the desired information from the raw measurements. Tracer gas concentrations are monitored during leakage and ventilation tests in the model test room. The signal analysis functions are introduced to carry out the digital signal processing (DSP) work. Overall the FIR filters process the $CO_2$ measurement properly for ventilation rate and mean age of air calculations. It is found that, the Kaiser filter was the most applicable digital filter for pre-processing the tracer gas measurements. Although the IIR filters help to reduce the random noise in the data, they cause considerable changes to the filtered data, which is not desirable.

Aequorin Based Functional Assessment of the Melanin Concentrating Hormone Receptor by Intracellular Calcium Mobilization

  • Lee, Sung-Hou
    • Biomolecules & Therapeutics
    • /
    • v.18 no.2
    • /
    • pp.152-158
    • /
    • 2010
  • Melanin concentrating hormone is a neuropeptide highly expressed in the brain that regulates several physiological functions mediated by receptors in the G-protein coupled receptor family, especially plays an important role in the complex regulation of energy balance and body weight mediated by the melanin concentrating hormone receptor subtype 1 (MCH1). Compelling pharmacological evidence implicating MCH1 signaling in the regulation of food intake and energy expenditure has generated a great deal of interest by pharmaceutical companies as MCH1 antagonists may have potential therapeutic benefit in the treatment of obesity and metabolic syndrome. Although fluorescence-based calcium mobilization assay platform has been one of the most widely accepted tools for receptor research and drug discovery, fluorescence interference and shallow assay window limit their application in high throughput screening and have led to a growing interest in alternative, luminescence-based technologies. Herein, a luminescence-based functional assay system for the MCH1 receptor was developed and validated with the mitochondrial targeted aequorin. Aequorin based functional assay system for MCH1 presented excellent Z' factor (0.8983) and high signal-to-noise ratio (141.9). The nonpeptide MCH1 receptor antagonist, SNAP 7941 and GSK 803430, exhibited $IC_{50}$ values of 0.62 ${\pm}$ 0.11 and 12.29 ${\pm}$ 2.31 nM with excellent correlation coefficient. These results suggest that the aequorin based assay system for MCH1 is a strong alternative to the traditional GPCR related tools such as radioligand binding experiments and fluorescence functional determinations for the compound screening and receptor research.