• 제목/요약/키워드: Correlated Flow

검색결과 499건 처리시간 0.029초

Electrorheology of Hollow Polyaniline Pimelate Suspension by Conduction Model

  • Choi Ung-Su
    • KSTLE International Journal
    • /
    • 제7권1호
    • /
    • pp.1-4
    • /
    • 2006
  • The electro rheological behavior of the hollow polyaniline pimelate suspension in silicone oil was investigated. Hollow polyaniline pimelate suspension showed a typical ER response (Bingham flow behavior) upon application of an electric field. The shear stress for the suspension exhibited the dependence with a factor equals to 0.84 power on the electric field. The experimental results for the hollow polyaniline pimelate suspension correlated with the conduction models of Tang et al., and this suspension behaved as an ER fluid.

전도성 모델에 의한 인산에스테르셀룰로오즈 현탁액의 전기유변학적 특성 연구 (Electrorheological Properties of Cellulose Phosphate Ester Suspension by Conduction Models)

  • 최웅수;고영건;박용성;권오관
    • Tribology and Lubricants
    • /
    • 제17권2호
    • /
    • pp.124-129
    • /
    • 2001
  • The electrical and rheological behaviors of the cellulose phosphate ester suspension in the silicone oil were investigated. Cellulose phosphate ester suspension showed a typical ER response (Bingham flow behavior) upon application of an electric field. The shear stress for the cellulose phosphate ester suspension exhibited a linear dependence on the volume fraction of particles and a square power of the electric field. On the basis of the experimental results, cellulose phosphate ester suspension correlated with the conduction model of Tang et al, and found to be an ER fluid.

CORRELATION STUDY OF THE MEASURED TUMBLE RATIOS USING THREE DIFFERENT METHODS: STEADY FLOW RIG; 2-DIMENSIONAL PIV; AND 3-DIMENSIONAL PTV WATER FLOW RIG

  • Kim, M.J.;Lee, S.H.;Kim, W.T.
    • International Journal of Automotive Technology
    • /
    • 제7권4호
    • /
    • pp.441-448
    • /
    • 2006
  • In-cylinder flows such as tumble and swirl play an important role on the engine combustion efficiencies and emission formations. The tumble flow, which is dominant in current high performance gasoline engines, is able to effect fuel consumptions and emissions under a partial load condition in addition to the volumetric efficiency under a wide open throttle condition. Therefore, it is important to optimize the tumble ratio of a gasoline engine for better fuel economy, lower emissions, and maximum volumetric efficiency. First step for optimizing a tumble ratio is to measure a tumble ratio accurately. For a tumble ratio measurement, many different methods have been developed and used such as steady flow rig, PIV, PTV, and LDV. However, it is not well known about the relations among the measured tumble ratios using different methods. The purpose of this research is to correlate the tumble ratios measured using three different methods and find out merits and demerits of each measurement method. In this research the tumble flow was measured, compared, and correlated using three different measurement methods at the same engine: steady flow rig; 2-dimensional PIV; and 3-dimensional PTV water flow rig.

이산 웨이블릿 변환을 이용한 3차원 난류 채널 유동에 관한 연구 (A Study of 3-Dimensional Turbulent Channel Flow Using Discrete Wavelet Transform)

  • 김강식;이상환
    • 대한기계학회논문집B
    • /
    • 제29권3호
    • /
    • pp.314-321
    • /
    • 2005
  • Discrete Wavelet Transform (DWT) has been applied to the Direct Numerical Simulation (DNS) data of turbulent channel flow. DWT splits the turbulent flow into two orthogonal parts, one corresponding to coherent structures and the other to incoherent background flow. The coherent structure is extracted from not vorticity field but velocity's since the channel flow is not isoropic. By comparing DWT's result of channel flow with that of isotropic flow, it is shown that coherent structure maintains the properties of original channel flow. The velocity field of coherent structures can be represented by few wavelet modes and that these modes are sufficient to reproduce the velocity probability density function (PDF) and the energy spectrum over the entire inertial range. The remaining incoherent background flow is homogeneous, has small amplitude, and is uncorrelated. These results are compared with those obtained for the same compression rate using large eddy simulation (LES) filtering. In contrast to the incoherent background flow of DWT, the LES subgrid scales have a much larger amplitude and are correlated, which makes their statistical modeling more difficult.

이산 웨이블릿 변환을 이용한 3차원 난류 채널 유동에 관한 연구 (A Study of 3-Dimensional Turbulent Channel Flow using Discrete Wavelet Transform)

  • 김강식;이상환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1813-1818
    • /
    • 2004
  • Discrete Wavelet Transform (DWT) has been applied to the Direct Numerical Simulation (DNS) data of turbulent channel flow. DWT splits the turbulent flow into two orthogonal parts, one corresponding to coherent structures and the other to incoherent background flow. The coherent structure is extracted from not vorticity field but velocity's since the channel flow is not isotropic. By comparing DWT's result of channel flow with that of isotropic flow, it is shown that coherent structure maintains the properties of original channel flow. The velocity field of coherent structures can be represented by few wavelet modes and that these modes are sufficient to reproduce the velocity probability distribution function (PDF) and the energy spectrum over the entire inertial range. The remaining incoherent background flow is homogeneous, has small amplitude, and is uncorrelated. These results are compared with those obtained for the same compression rate using large eddy simulation (LES) filtering. In contrast to the incoherent background flow of DWT, the LES subgrid scales have a much larger amplitude and are correlated, which makes their statistical modeling more difficult.

  • PDF

A Laboratory Study of the Effect of Phytoplankton Concentration, Water Flow and Their Interaction on the Growth of the Sandy Shore Suspension Feeding Clam Gafrarium tumidum

  • Shin, P.K.S.;Cheung, S.G.
    • Journal of Ecology and Environment
    • /
    • 제30권2호
    • /
    • pp.127-133
    • /
    • 2007
  • The effects of water flow rate and phytoplankton concentration on the growth of the sandy shore clam Gafrarium tumidum was investigated in a laboratory flume study using a $3{\times}3$ factorial design. After 60 days, shell length, shell weight and tissue dry weight increased significantly with phytoplankton concentration. For the effect of flow rate, growth was faster when flow rate increased from low to medium level; further increases in flow rate, however, either did not sustain faster growth or resulted in a reduction in growth. The condition index (CI) of a standard-sized clam was significantly higher at low flow rate than at medium and high flow rates and was negatively correlated with phytoplankton concentration. The uncoupled growth of shell and tissue in response to flow rate and phytoplankton concentration may be adaptations to low food environments, so that energy can either be stored to sustain life or reserved for gametogenesis during the reproductive period.

고빈도 진동 환기가 동맥혈의 호흡성 가스에 미치는 영향 (Factors influencing arterial $CO_2$ tension in cats during high frequency oscillation ventilation)

  • 도준영;이재익;이관호;김영조;정재천;이현우;이석강
    • Journal of Yeungnam Medical Science
    • /
    • 제6권2호
    • /
    • pp.47-55
    • /
    • 1989
  • 고빈도 진동환기가 동맥혈의 가스분압에 미치는 영향을 알아보고자 저자들은 9마리의 고양이를 대상으로 진동빈도, 일회분출량 및 bias flow를 다양하게 변화시켜 아래와 같은 결과를 얻었다. 1) 일회분출량과 bias flow를 고정시킨 후 진동빈도를 점차 증가시켜 도 $PaCO_2$의 변동은 없었다(Table 1). 2) 진동빈도를 고정시킨 후 일회분출량과 bias flow를 변화시켜 관찰하였던 바 $PaCO_2$는 bias flow의 변화와는 상관관계가 없으나, 일회분출량의 변화와는 유의한 상관관계가 있었다(p<0.01)(Table 2, Fig. 1). 3) $PaCO_2$는 진동빈도를 15Hz로 고정시킨 상태하에서는 1회 분출량 및 bias flow를 증가시켜도 큰 변동없이 정상으로 유지되었다(Table 2). 이상의 결과로 고빈도 진동환기법에서 $PaCO_2$의 결정인자는 진동빈도와 bias flow와는 무관하였고 일회분출량과는 상관관계가 있음을 알 수 있었다.

  • PDF

Correlations between the Respiratory Function and Cervical and Lumbar Range of Motion in Elderly People

  • Park, Du-Jin;Kim, Jun-Seok;Hwang, Young-In
    • 대한물리의학회지
    • /
    • 제16권3호
    • /
    • pp.29-36
    • /
    • 2021
  • PURPOSE: The respiratory function and range of joint mobility deteriorate due to aging, respectively, and the respiratory function may be related to the range of joint mobility. To the best of the authors' knowledge, there has been little research on how the deterioration of the range of joint mobility caused by aging is related directly to the respiratory function. This study investigated the relationship between the respiratory function and the range of joint motion in the cervical and lumbar regions of older adults. METHODS: Thirty-two older adults participated in the study. The forced vital capacity (peak expiratory flow: PEF and forced expiratory volume in 1 second: FEV1) and the range of cervical joint motion were assessed in all subjects. The results were analyzed using the Pearson's correlation coefficient. RESULTS: The respiratory function moderately correlated with age. A moderate correlation was observed between FEV1 and right cervical lateral flexion. PEF was moderately correlated with the lumbar lateral flexion. In addition, FEV1 correlated strongly with lumbar lateral flexion. CONCLUSION: The respiratory function was correlated with the cervical and lumbar lateral flexion. Therefore, rehabilitation of the respiratory function should involve improving the limited range of motion of the joints, and a stretching program is needed for older adults.

수직축을 중심으로 회전하는 직관과 정지한 곡관 내부의 발달하는 층류 유동의 유사성에 관한 수치적 연구 (A Numerical Study on the Similarity of the Developing Laminar Flows between in Orthogonally Rotating Square Duct and Stationary Curved Square Duct)

  • 이공희;백제현
    • 한국전산유체공학회지
    • /
    • 제6권1호
    • /
    • pp.21-30
    • /
    • 2001
  • A numerical study on the similarity of the developing laminar flows between in a straight duct rotating about an axis perpendicular to that of the duct and in a stationary curved duct was carried out. In order to clarify the analogy of two flows, dimensionless parameters K/sub LR/ = Re/(equation omitted) and Rossby number, Ro, in a rotating straight duct were used as a set corresponding to Dean number K/sub LC/ = Re/(equation omitted), and curvature ratio, λ, in a stationary curved duct. For the large values of Ro and λ, it is shown that the flow field satisfies the 'asymptotic invariance property', that is, there are strong quantitative similarities between the two flows such as flow patterns, friction factors, and maximum axial velocity magnitudes for the same values of K/sub LR/ and K/sub LC/ if they are correlated with dimensionless axial distances Z/sub R/ = z/(equation omitted) for a rotating duct flow and Z/sub C/ = z/(equation omitted) for a stationary curved duct flow.

  • PDF

대구지방 하천의 집중 강우후의 수계환경의 변화 (Environmental Changes of the Rivers in Taegu Area after a Heavy Rain)

  • Lyu, Seung-Won;Song, Seung-Dal
    • The Korean Journal of Ecology
    • /
    • 제6권2호
    • /
    • pp.81-89
    • /
    • 1983
  • The change of environmental factors with flow rates were studied quantitatively for two rivers, the Nakdong River and the Sin stream, which have different basins in ecosystem structures, during short period after a heavy rain. In the Nakdong River, transparency, DO, alkalinity and hardness were negatively correlated with the flow rate by logarithmic function, but the concentration of SiO2 was relatively constant regardless of the flow chage. In the Sin stream, transparency, alkalinity, hardness and the concentration of NH3-N, NO2-N and SO4= showed negative correlation with the flow rate by logarithmic function. The ratios of maximum to minimum values for aquatic environmental factors during the samller than that for flow rate in the respective rivers (28 in the Nakdong R.; 50 in the Sin S.). Immediately after the heavy rain, the concentrations of NO2-N, NH3-N and PO4-P in the Sin stream were 8, 6 and 1 times as high as those in the Nakdong River, respectively, but in the stable flow state, those became 94, 25 and more than 10 times, respectively. The load for most of the dissolved environmental constituents changed similarly to the flow rate in both rivers. It is notable that, at the stable flow state, the loads for NH3-N (59g/sec) and NO2-N (3.3g/sec) in the Sin stream were 4.3 and 1.3 times as high as those in the Nakdong River.

  • PDF