• 제목/요약/키워드: Correction Analysis

검색결과 2,485건 처리시간 0.031초

수분 함량별 부풀성 보정식 설정 (Establishment of Correction Equation for Filling Volumn according to Moisture Content)

  • 정한주;김용옥
    • 한국연초학회지
    • /
    • 제27권1호
    • /
    • pp.94-99
    • /
    • 2005
  • To correct the difference of filling volumn for various cut tobacco and puffed stem according to moisture contents, correction equation was estamated by a simple regression analysis. The $R^2$(coefficient of determination) of correction equation was above 0.95. To verify the precision of correction equation, we predicted correction equation of other samples. The filling volumns by the difference of $1\%$ moisture content were $0.018\;~\;0.022cc/g$ (cut tobacco) and 0.060cc/g (puffed stem). The precision of correction equation for various cut tobacco was very high, but that of puffed stem was low due to quality deviation of row stem according to a season.

핵의학 영상의 물리적 인공산물보정: 정규화보정 및 감쇠보정 (Physical Artifact Correction in Nuclear Medicine Imaging: Normalization and Attenuation Correction)

  • 김진수;이재성;천기정
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권2호
    • /
    • pp.112-117
    • /
    • 2008
  • Artifact corrections including normalization and attenuation correction were important for quantitative analysis in Nuclear Medicine Imaging. Normalization is the process of ensuring that all lines of response joining detectors in coincidence have the same effective sensitivity. Failure to account for variations in LOR sensitivity leads to bias and high-frequency artifacts in the reconstructed images. Attenuation correction is the process of the correction of attenuation phenomenon lies in the natural property that photons emitted by the radiopharmaceutical will interact with tissue and other materials as they pass through the body. In this paper, we will review the several approaches for normalization and attenuation correction strategies.

편광 Zeeman 보정 및 D2 보정 방법에 의한 혈중연 측정치의 비교 연구 (A Comparative Study of Blood Lead Measurement by Polarized Zeman Effect Correction AAS and D2 Correction AAS Method)

  • 이석기;안규동;이병국
    • 한국산업보건학회지
    • /
    • 제5권1호
    • /
    • pp.59-67
    • /
    • 1995
  • 현재 국내에서 원자흡광법에 의한 혈중연 분석은 분석선 283.3 nm에서의 $D_2$ 보정 방식을 이용한 흑연로 원자흡광법이 주로 이용되고 있으며, 일반적인 시료중 납에 관한 분석은 217.0 nm에서의 $D_2$ 보정 방식이 보편화되어 있다. 그러나 이들 방식은 바탕 보정에 제한성 때문에 새로운 바탕 보정법에 대해 관심을 가지게 되었다. 그러던 중 1980년대 말부터 혈중연 분석자들은 연 분석에 있어 Zeeman effect 보정방식이 보다 좋은 결과를 나타낸다 하여 이 방법에 대하여 관심을 갖게 되었다. 따라서 본 연구는 국내 대부분의 혈중연 분석기관들이 보유하고 있는 $D_2$ 보정방식 (217.0과 283.3 nm)의 혈중연 측정결과를 편광 Zeeman effect 보정방식의 측정 결과와 비교함으로서 현재 사용 중인 기기 들의 측정결과의 타당성을 검토하기 위하여 시도하였으며 다음과 같은 결과를 얻었다. Zeeman형의 바탕보정 방식을 사용하는 기기의 결과를 편의상 1.00으로 하고, $D_2$ 형 보정 장치의 217.0 nm와 283.3 nm에서의 결과를 짝비교 (paired t-test)를 하였을 때 혈중연 농도가 $20.0{\mu}g/dl$ 이하인 경우에 0.92와 0.90으로 Zeeman형보다 낮은 값으로 분석되었으며 통계적으로 유의하였다.(P<0.001). $20.1-40.0{\mu}g/dl$인 군에서는 $D_2$ 보정방식의 결과간에 차이는 없었다. Zeeman 및 $D_2$ 보정방법에서는 혈중연 증가에 따른 바탕보정장치의 변동이 적었고 혈중연 이외의 다른 금속 즉, 철, 구리, 아연에서는 바탕보정장치에 관계없이 철은 역상관인 것으로 나타났으며, 구리와 아연은 정상관을 갖는 것으로 나타났다. 연구 결과로 미루어보아 두방법간의 차이가 없으므로 혈중연 분석에 있어서 Zeeman형 바탕보정 장치를 사용하거나 $D_2$ 바탕보정 방식(217.0, 283.3nm)의 기기를 사용하여도 무난할 것으로 생각된다.

  • PDF

자세교정프로그램에 따른 자세유지 수행과 자기효능감에 관한 연구 (A Study on the Posture Maintenance Performance and Self-Efficacy in accordance with Posture Correction Program)

  • 장수경
    • 대한물리치료과학회지
    • /
    • 제7권2호
    • /
    • pp.459-474
    • /
    • 2000
  • The purpose of this study is to identify the posture correction program as the development of the posture maintenance performance, and search for the more efficient posture correction program. The data analysis was processed by SPSS. The data was analysed with $x^2$-test, t-test, pearson product moment correlation, and stepwise regression analysis. The finding of this study is as follows: There are the homogeneity between two groups was verified on the know ledges CF=.697, df=2, P>.05), self-efficacy(F=.098, df=2, P>.05) about the posture. The developed posture correction program has proved to enhance the posture maintenance performance(knowledge t=1.60, P<.05 ; posture manintenance t=7.69, P<.01). The type of posture correction program showed some significant differences (t=5.62, P<.01) in the accuracy of movement way among the factors of the posture maintenance performance. The posture maintenance performance affected self-efficacy. Therefore, the major conclusion is as follows: The posture correction program was meaningfully effective on developing the posture maintenance, and with practice created accuracy much more on the posture maintenance movement way. The development of the posture maintenance performance affected the increase of self-efficacy about the posture. The self-efficacy has proved so powerful factor to influence on the posture maintenance performance development. So, the posture correction program should be done systematically and continually, and developing the posture maintenance performance should be done with practice. After the education, it should be reinforced through practice, midterm identification and reeducation and motivated with recognizing the accurate posture measurement. And it should be created the correction program to develop the high self-efficacy about the posture. It needs the strategy to educate the correct posture individually, and to spread to the society for healthy life style.

  • PDF

Performance Analysis of GNSS Residual Error Bounding for QZSS CLAS

  • Yebin Lee;Cheolsoon Lim;Yunho Cha;Byungwoon Park;Sul Gee Park;Sang Hyun Park
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제12권3호
    • /
    • pp.215-228
    • /
    • 2023
  • The State Space Representation (SSR) method provides individual corrections for each Global Navigation Satellite System (GNSS) error components. This method can lead to less bandwidth for transmission and allows selective use of each correction. Precise Point Positioning (PPP) - Real-Time Kinematic (RTK) is one of the carrier-based precise positioning techniques using SSR correction. This technique enables high-precision positioning with a fast convergence time by providing atmospheric correction as well as satellite orbit and clock correction. Currently, the positioning service that supports PPP-RTK technology is the Quazi-Zenith Satellite System Centimeter Level Augmentation System (QZSS CLAS) in Japan. A system that provides correction for each GNSS error component, such as QZSS CLAS, requires monitoring of each error component to provide reliable correction and integrity information to the user. In this study, we conducted an analysis of the performance of residual error bounding for each error component. To assess this performance, we utilized the correction and quality indicators provided by QZSS CLAS. Performance analyses included the range domain, dispersive part, non-dispersive part, and satellite orbit/clock part. The residual root mean square (RMS) of CLAS correction for the range domain approximated 0.0369 m, and the residual RMS for both dispersive and non-dispersive components is around 0.0363 m. It has also been confirmed that the residual errors are properly bounded by the integrity parameters. However, the satellite orbit and clock part have a larger residual of about 0.6508 m, and it was confirmed that this residual was not bounded by the integrity parameters. Users who rely solely on satellite orbit and clock correction, particularly maritime users, thus should exercise caution when utilizing QZSS CLAS.

An Algorithm for Baseline Correction of SELDI/MALDI Mass Spectrometry Data

  • Lee, Kyeong-Eun
    • Journal of the Korean Data and Information Science Society
    • /
    • 제17권4호
    • /
    • pp.1289-1297
    • /
    • 2006
  • Before other statistical data analysis the preprocessing steps should be performed adequately to have meaningful results. These steps include processes such as baseline correction, normalization, denoising, and multiple alignment. In this paper an algorithm for baseline correction is proposed with using the piecewise cubic Hermite interpolation with block-selected points and local minima after denoising for SELDI or MALDI mass spectrometry data.

  • PDF

KOMPSAT-3 영상을 활용한 도심지 그림자 영역의 탐지 및 보정 방법 (Shadow Detection and Correction Method for Urban Area using KOMPSAT-3 Image)

  • 박숭환;이규석;정형섭
    • 대한원격탐사학회지
    • /
    • 제33권6_3호
    • /
    • pp.1197-1213
    • /
    • 2017
  • 본 연구는 KOMPSAT-3 위성영상의 도심지역에 나타나는 그림자 영역을 보정하기 위하여 실시되었다. 이를 위하여, 인공구조물에 의해 나타나는 그림자 영역에 대한 특성을 분석하여 그림자 영역을 본그림자와 반그림자로 구분하였으며, 각각의 영역을 정확하게 탐지하여 오분류의 가능성을 줄이기 위한 방법을 제시하였다. 또한 본그림자 영역으로부터 반그림자 영역과 비그림자 영역을 각각 탐지하였으며, 선형상관보정방법과 과보정 저감계수를 적용하여 탐지된 그림자 영역에 대한 보정을 수행하였다. 그 결과 시각적으로 자연스러운 보정된 영상을 획득할 수 있었으며, 프로파일 분석을 통하여 정량적으로도 그림자 영역이 효과적으로 보정됨을 확인하였다.

지역 위성항법시스템 항법메시지 및 광역 보정정보 성능 분석을 위한 MATLAB GUI 기반 소프트웨어 개발 (Development of MATLAB GUI-based Software for Performance Analysis of RNSS Navigation Message and WAD-RNSS Correction)

  • 박재욱;김부겸;기창돈;김동욱
    • 한국항행학회논문지
    • /
    • 제27권5호
    • /
    • pp.510-518
    • /
    • 2023
  • 본 논문에서는 지역 위성항법시스템의 항법메시지와 광역 보정정보 성능 분석을 위해 MATLAB GUI (graphic user interface) 기반으로 개발된 소프트웨어에 대해 소개한다. 본 소프트웨어는 한반도 및 주변 지역에 서비스를 제공하는 가상의 지역 위성항법시스템의 감시국 및 기준국 배치에 따른 항법메시지와 광역 보정정보의 위성 궤도/시각 관련 성능을 분석하기 위해 개발되었다. 본 소프트웨어 구동 시 항법메시지 및 광역 보정정보가 MATLAB 파일 형식으로 출력된다. 개발된 소프트웨어의 출력을 검증한 결과, 궤도 및 시계 예측 오차가 통계적 예측에 부합하며, 파라미터 피팅 오차가 cm 수준임을 확인하였다. 또한, 광역 보정정보가 측정치 차원의 오차를 81.9% 개선함을 확인하여 유효한 항법메시지 및 광역 보정정보 성능 분석이 가능함을 확인하였다.