• Title/Summary/Keyword: Correct 3D depth

Search Result 37, Processing Time 0.024 seconds

Nonlinearity effect on the dynamic behavior of the clayey basin edge

  • Hadi Khanbabazadeh
    • Geomechanics and Engineering
    • /
    • v.36 no.4
    • /
    • pp.367-380
    • /
    • 2024
  • Investigations has shown that the correct estimation of the effective amplification period is as important as the amplification value itself. It gets more important in 2D basins. This study presents a quantitative coefficient for consideration of the nonlinearity effect in terms of amplification value and the shift in its period which is missing or ineffectively considered in the previous studies. To attain this goal, by the application of a time domain fully nonlinear method, the deviation of the more common equivalent linear results from the basin nonlinear behavior under strong ground motions is investigated quantitatively. Also, despite the increase in the damping ratio, the possibility of the increase in the amplification due to the increase in motion strength is shown. To make the results useful in engineering practice, by introducing nonlinearity ratio, the effect of the nonlinearity is quantitatively estimated for two soft and stiff clayey basins with three different depths under a set of motions scaled to two target spectrum. Results show that at the 100 m depth soft clayey basin, while the nonlinearity ratio shows a 35% deviation at the basin edge part under DD1 motion level, its effect moves to the central part with 20% effect under DD3 motion level. By the increase in depth to 150 m, the results show a decrease in the overall effect of the nonlinear behavior for both clay types. At this depth, the nonlinearity ratio gives a 30% and 17% difference on a limited distance from outcrop at the soft clayey basin under DD1 and DD3 motion levels, respectively. At the 30 m depth basins, the nonlinearity ratio shows up to 25% difference for different cases. The presented ratio would be introduced as nonlinearity coefficients for consideration of the nonlinearity effects in the codes. The presented quantitative margins will help the designer to have a better understanding of the amplification period change because of nonlinearity over 2D basin surface.

Hybrid Camera System with a TOF and DSLR Cameras (TOF 깊이 카메라와 DSLR을 이용한 복합형 카메라 시스템 구성 방법)

  • Kim, Soohyeon;Kim, Jae-In;Kim, Taejung
    • Journal of Broadcast Engineering
    • /
    • v.19 no.4
    • /
    • pp.533-546
    • /
    • 2014
  • This paper presents a method for a hybrid (color and depth) camera system construction using a photogrammetric technology. A TOF depth camera is efficient since it measures range information of objects in real-time. However, there are some problems of the TOF depth camera such as low resolution and noise due to surface conditions. Therefore, it is essential to not only correct depth noise and distortion but also construct the hybrid camera system providing a high resolution texture map for generating a 3D model using the depth camera. We estimated geometry of the hybrid camera using a traditional relative orientation algorithm and performed texture mapping using backward mapping based on a condition of collinearity. Other algorithm was compared to evaluate performance about the accuracy of a model and texture mapping. The result showed that the proposed method produced the higher model accuracy.

Eye Contact System Using Depth Fusion for Immersive Videoconferencing (실감형 화상 회의를 위해 깊이정보 혼합을 사용한 시선 맞춤 시스템)

  • Jang, Woo-Seok;Lee, Mi Suk;Ho, Yo-Sung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.7
    • /
    • pp.93-99
    • /
    • 2015
  • In this paper, we propose a gaze correction method for realistic video teleconferencing. Typically, cameras used in teleconferencing are installed at the side of the display monitor, but not in the center of the monitor. This system makes it too difficult for users to contact each eyes. Therefore, eys contact is the most important in the immersive videoconferencing. In the proposed method, we use the stereo camera and the depth camera to correct the eye contact. The depth camera is the kinect camera, which is the relatively cheap price, and estimate the depth information efficiently. However, the kinect camera has some inherent disadvantages. Therefore, we fuse the kinect camera with stereo camera to compensate the disadvantages of the kinect camera. Consecutively, for the gaze-corrected image, view synthesis is performed by 3D warping according to the depth information. Experimental results verify that the proposed system is effective in generating natural gaze-corrected images.

Body Segment Length and Joint Motion Range Restriction for Joint Errors Correction in FBX Type Motion Capture Animation based on Kinect Camera (키넥트 카메라 기반 FBX 형식 모션 캡쳐 애니메이션에서의 관절 오류 보정을 위한 인체 부위 길이와 관절 가동 범위 제한)

  • Jeong, Ju-heon;Kim, Sang-Joon;Yoon, Myeong-suk;Park, Goo-man
    • Journal of Broadcast Engineering
    • /
    • v.25 no.3
    • /
    • pp.405-417
    • /
    • 2020
  • Due to the popularization of the Extended Reality, research is actively underway to implement human motion in real-time 3D animation. In particular, Microsoft developed Kinect cameras for 3D motion information can be obtained without the burden of facilities and with simple operation, real-time animation can be generated by combining with 3D formats such as FBX. Compared to the marker-based motion capture system, however, Kinect has low accuracy due to its lack of estimated performance of joint information. In this paper, two algorithms are proposed to correct joint estimation errors in order to realize natural human motion in motion capture animation system in Kinect camera-based FBX format. First, obtain the position information of a person with a Kinect and create a depth map to correct the wrong joint position value using the human body segment length constraint information, and estimate the new rotation value. Second, the pre-set joint motion range constraint is applied to the existing and estimated rotation value and implemented in FBX to eliminate abnormal behavior. From the experiment, we found improvements in human behavior and compared errors between algorithms to demonstrate the superiority of the system.

EEG Signal Characteristic Analysis for Monitoring of Anesthesia Depth Using Bicoherence Analysis Method (바이코히어런스 분석 기법을 이용한 마취 단계별 뇌파의 특성 분석)

  • Park Jun-Mo;Park Jong-Duk;Jeon Gye-Rok;Huh Young
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.1
    • /
    • pp.35-41
    • /
    • 2006
  • Although reachers have studied for a long time, they don't make criteria for anesthesia depth. anesthetists can't make a prediction about patient's reaction. Therefor, patients have potential risk such as poisonous side effect late-awake, early-awake and strain reaction. EEG are received from twenty-five patients who agreed to investigate themselves during operation with Enflurane-anesthesis in progress of anesthesia. EEG are divided pre-anesthesia, before incision of skin, operation 1, operation 2, awaking, post-anesthesia by anesthesia progress step. EEG is applied pre-processing, base line correct, linear detrend to get more reliable data. EEG data are handled by electronic processing and the EEG data are calculated by bicoherence. During pre-anesthesia and post anesthesia, appearance rate of bicoherence value is observed strong appearance rate in high frequency range($15\~30Hz$). During the anesthesia of patient, a strong appearance rate is revealed the low frequency area(0~10Hz). After bicoherence is calculated by percentage of a appearance rate, that is, Bicpara$\#$1, Bicpara$\#$2, Bicpara$\#$3 and Bicpara$\#$4 parameter are extracted. In result of bicoherence analysis, Bicpara$\#$2 and Bicpara#4 are considered that the best parameter showed progress of anesthesia effectively. And each separated bicoherence are calculated by average bicoherence's numerical value, divide by 2 area, appear by each BicHz$\#$1, BicHz$\#$2, and observed BicHz$\#$1/BicHz$\#$2's change. In result of bicoherence analysis, BicHz$\#$1, BicHz$\#$2 and BicHz$\#$1/BicHz$\#$2 are considered that the best parameter showed progress of anesthesia effectively. In conclusion, I confirmed the anesthesia progress phase, concluded to usefulness of parameter on bispectrum and bicoherence analysis and evaluated the depth of anesthesia. In the future, it is going to use for doctor's diagnosis and apply to protect an medical accident owing to anesthesia.

Distributed Coding Scheme for Multi-view Video through Efficient Side Information Generation

  • Yoo, Jihwan;Ko, Min Soo;Kwon, Soon Chul;Seo, Young-Ho;Kim, Dong-Wook;Yoo, Jisang
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1762-1773
    • /
    • 2014
  • In this paper, a distributed image coding scheme for multi-view video through an efficient generation of side information is proposed. A distributed video coding technique corrects the errors in the side information, which is generated with the original image, by using the channel coding technique at the decoder. Therefore, the more correct the generated side information is, the better the performance of distributed video coding. The proposed technique is to apply the distributed video coding schemes to the image coding for multi-view video. It generates side information by selectively and efficiently using both 3-dimensional warping based on the depth map with spatially adjacent frames and motion-compensated temporal interpolation with temporally adjacent frames. In this scheme the difference between the adjacent frames, the sizes of the motion vectors for the adjacent blocks, and the edge information are used as the selection criteria. From the experiments, it was observed that the quality of the side information generated by the proposed technique was improved by the average peak signal-to-noise ratio of 0.97dB than the one by motion-compensated temporal interpolation or 3-dimensional warping. The result from analyzing the rate-distortion curves revealed that the proposed scheme could reduce the bit-rate by 8.01% on average at the same peak signal-to-noise ratio value, compared to previous work.

Comparison of mandibular arch forms of Korean and Vietnamese patients by using facial axis points on three-dimensional models

  • Lee, Kil-Jun;Trang, Vu Thi Thu;Bayome, Mohamed;Park, Jae Hyun;Kim, Yong;Kook, Yoon-Ah
    • The korean journal of orthodontics
    • /
    • v.43 no.6
    • /
    • pp.288-293
    • /
    • 2013
  • Objective: This study was aimed at comparing the mandibular arch forms of Korean and Vietnamese patients by using facial axis (FA) points on three-dimensional (3D) models. Methods: Mandibular casts of 68 Korean (Class I malocclusion, 30; Class II malocclusion, 38) and 78 Vietnamese (Class I malocclusion, 41; Class II malocclusion, 37) patients were scanned in their occluded positions and grouped according to arch form (tapered, ovoid, and square). The FA point of each tooth was digitized on the 3D mandibular models. The measurements and frequency distributions of the arch forms were compared between the ethnic groups. Results: The Vietnamese patients had significantly greater intercanine depth and intercanine and intermolar width-to-depth ratios than the Korean patients (p < 0.05). The frequency distributions of the arch forms were also significantly different (p = 0.038), but no sexual dimorphism was found. Conclusions: Vietnamese people tend to have deeper and wider arches than Korean people. The three arch forms are evenly distributed in Korean people, but Vietnamese people frequently have square arches. Clinicians should identify the correct arch form of an ethnic group before initiating orthodontic treatment.

Finite Element Simulation of Laser-Generated Ultrasound and Interaction with Surface Breaking Cracks (유한요소법을 이용한 레이저 유도 초음파와 표면 균열과의 상호작용 모델링)

  • Jeong, Hyun-Jo;Park, Moon-Cheol
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • A finite element method is used to simulate interaction of laser-based ultrasounds with surface breaking tracks in elastic media. The laser line source focused on the surface of semi-infinite medium is modeled as a shear dipole in 2-D plane strain finite elements. The shear dipole-finite clement model is found to give correct directivity patterns for generated longitudinal and shear waves. The interaction of surface waves with surface breaking cracks (2-D machined slot) is considered in two ways. Both the source and receiver are fixed with respect to the cracks in the first case, while the source is moving in another case. It is shown that the crack depth tested in the range of 0.3-5.0mm $({\lambda}_R/d=0.21{\sim}3.45)$ can be measured using the corner reflected waves produced by the fixed laser source. The moving laser source is found to cause a large amplitude change of reflected waves near crack, and the crack whose depth is one order lower than the wavelength ran be detected from this change.

Contemporary Approach to Autotransplantation of Teeth with Complete Roots Using 3D-printing Technology (3D 프린팅 기술을 이용한 치근단 완성 치아의 자가이식에 대한 최신 접근)

  • Park, Jungha;Lee, Sangho;Lee, Nanyoung;Jih, Myoungkwan;Cheong, Hyeran
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.4
    • /
    • pp.461-468
    • /
    • 2017
  • Autotransplantation of teeth with complete roots is being increasingly performed for orthodontic treatment or for replacement of unsalvageable teeth, but this procedure has lower survival and success rates than those obtained following transplantation of teeth with incomplete root formation. While previous autotransplantation procedures used only models of the donor tooth and recipient site, surgical guide templates created using 3D-printing technology are now available. They allow shaping of the recipient site in proper direction and to the correct depth, thereby reducing the treatment time and improving the success and survival rates. Herein, we report a case involving autotransplantation of a tooth with complete roots at the site of a congenitally missing permanent tooth using surgical guide templates generated with 3D-printing technology. The procedure resulted in favorable healing of the transplanted tooth.

Underwater Hybrid Navigation Algorithm Based on an Inertial Sensor and a Doppler Velocity Log Using an Indirect Feedback Kalman Filter (간접 되먹임 필터를 이용한 관성센서 및 초음파 속도센서 기반의 수중 복합항법 알고리듬)

  • 이종무;이판묵;성우제
    • Journal of Ocean Engineering and Technology
    • /
    • v.17 no.6
    • /
    • pp.83-90
    • /
    • 2003
  • This paper presents an underwater hybrid navigation system for a semi-autonomous underwater vehicle (SAUV). The navigation system consists of an inertial measurement unit (IMU), and a Doppler velocity log (DVL), accompanied by a magnetic compass. The errors of inertial measurement units increase with time, due to the bias errors of gyros and accelerometers. A navigational system model is derived, to include the scale effect and bias errors of the DVL, of which the state equation composed of the navigation states and sensor parameters is 20. The conventional extended Kalman filter was used to propagate the error covariance, update the measurement errors, and correct the state equation when the measurements are available. Simulation was performed with the 6-d.o,f equations of motion of SAUV, using a lawn-mowing survey mode. The hybrid underwater navigation system shows good tracking performance, by updating the error covariance and correcting the system's states with the measurement errors from a DVL, a magnetic compass, and a depth sensor. The error of the estimated position still slowly drifts in the horizontal plane, about 3.5m for 500 seconds, which could be eliminated with the help of additional USBL information.