• Title/Summary/Keyword: Corporation Concentration

Search Result 798, Processing Time 0.025 seconds

Comparison between Head Space Gas Sampling and Purge & Trap Sampling in Water Analysis

  • Nagayanagi, Yutaka;Nakagawa, Katsuhiro;Saito, Yoshihiro;Kim, Poongzag
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.739-744
    • /
    • 1995
  • The two main methods to prepare water samples for analyzing volatile organic compounds(VOC's) were investigated. One is the purge and trap(PT) method and another is the head space(HS) sampling method. Both methods were effective to transfer the low boiling point components from the water sample onto the capillary column. The cryo-focusing at the top of the main capillary column was an effective way to obtain the sharpness of the chromatographic peaks but could be avoided when a semi-wide bore column was used. The recovery from the same amount of the sample was better in PT than in HS but a larger sample volume in HS method could compensate the lower efficiency. Therefore PT is suitable to the analysis of drinking water where the very low concentration must be determined. HS is suitable to waste water analysis because of the easiness of the operation. The repeatability was good and similar in both methods. For the contamination of the former sample, both methods were tough and could be used without any problems. The matrix effect which could change the equilibrium parameters in HS method was find negligible in many components. The actual samples such as tap water and river water were analyzed with both methods concerning 16 components regulated in Korea.

  • PDF

Concentrations of lead, iron, and zinc in blood of coal wokers' pneumoconiosis patients (탄광부 진폐증자의 혈액 중 납, 철 및 아연 농도)

  • Choi, Ho-Chun;Chung, Ho-Keun;Kim, Hae-Jeong
    • Journal of Preventive Medicine and Public Health
    • /
    • v.22 no.4 s.28
    • /
    • pp.486-494
    • /
    • 1989
  • Lead, iron, and zinc concentrations in whole blood were determined by atomic absorption spectrophotometry, using a simple one-step dilution procedure, which were measured in 3 groups, 98 officers unexposed to dust or to metal, 58 coal miners without pneumoconiosis, and 113 coal workers' pneumoconiosis (CWP) patients. The results were as follows : 1. The precisions (C. V.%) of lead, iron, and zinc in blood were $12.65{\pm}6.95%,\;1.47{\pm}1.25%\;and\;6.35{\pm}3.34%$, respectively. 2. Lead and zinc in blood showed the log-normal distribution unlike iron in blood which showed normal distribution. 3. Lead, iron, and zinc concentrations in blood of 3 groups were follows : There was significant difference of concentration for zinc in blood by groups statistically. 4. The difference of lead, iron, and zinc concentrations in blood was not significant (p>0.05) by profusion on chest radiographs.

  • PDF

Simultaneous Extraction of Yttrium and Neodymium from Fly Ash by Two-Step Leaching Process with Aid of Ultrasonic Wave (2단계 침출 과정에서 발생되는 비산회로부터 초음파 활용하여 이트륨과 네오디뮴의 동시 추출)

  • Kim, Jae-Kwan;Park, Seok-Un
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.1
    • /
    • pp.153-159
    • /
    • 2021
  • A two-step process for increasing the leaching efficiency of yttrium and neodymium from coal fly ash were investigated at solid loadings of 5.0 g ash ~1,000 g ash/l of 1.0 N~10.0 N H2SO4, temperature ranging from 30℃ to 90℃, ultrasonic leaching time of 1~10 hours, and ultrasonic power of 25~200 W. The yttrium and neodymium from coal fly ash were effectively leached into ion phases by step change of the first conventional dissolution at room temperature and then the second heating process with the aid of ultrasonic wave, and maximum leaching efficiency of yttrium and neodymium obtained were 66 % and 63 %, respectively. The activation energies for the leaching reaction of yttrium and neodymium at second heating process dependent on leaching time and temperature were derived to be 41.540 kJmol-1 and 507.92 kJmol-1, respectively. The optimum conditions for the maximum leaching of yttrium and neodymium were found to be the solid loading of 250 g ash/l of H2SO4, solvent concentration of 2.0 N H2SO4, and second step process of temperatures of 30℃ for 3 hours and then 90℃ for 4 hours with ultrasonic intensity of 100 W.

Analysis of Potential on Measurement of SO2 and NO2 using Radiative Transfer Model and Hyperspectral Sensor (복사전달모델과 초분광센서를 이용한 아황산가스와 이산화질소의 농도 측정 가능성 분석)

  • Shin, Jung-il;Kim, Ik-Jae;Choi, Min-Jae;Lim, Seong-Ha
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.658-663
    • /
    • 2018
  • Current measuring methods for air quality are based on ground measurement networks and satellite data. New methods of collecting evidence with advanced sensors are needed because current methods have limitations in collecting evidence for the illegal emission of air pollutants at narrow areas or specific sites. This study analyzed the possibility of using an ultraviolet hyperspectral sensor to measure the concentration of nitrogen dioxide and sulfur dioxide. Two types of spectra were used: simulated spectra for gases with various concentrations using a radiative transfer model and observed spectra for each gas for a concentration. To understand the possibility of using a hyperspectral sensor, the differences between the simulated spectra and the observed spectra were analyzed, and the variation of simulated spectra were then analyzed according to the concentration. The results showed good agreement between observed spectra and simulated spectra. In addition, the absorption depth at specific wavelengths in the simulated spectra had a very strong correlation with the gas concentration. The gas concentration could be estimated using the hyperspectral sensor. In the future, validation would be needed to estimate the gas concentration through observations of various concentrations of gases using a hyperspectral sensor.

The change of oral volatile sulfur compounds(VSC) concentration after periodontal treatment (치주치료 후 구강 내 Volatile Sulfur Compounds(VSC)의 변화)

  • Kim, Sung-Hyun;Chae, Gyeong-Jun;Jung, Ui-Won;Kim, Chang-Sung;Choi, Seong-Ho;Cho, Kyoo-Sung;Chai, Jung-Kyu;Kim, Chong-Kwan;Bang, Eun-Gyeong
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.3
    • /
    • pp.653-659
    • /
    • 2006
  • Oral malodor may cause a significant social or psychological handicap to those suffering from it. Oral malodor has been correlated with the concentration of volatile sulfur compounds (VSC) produced in the oral cavity. Specific bacteria identified in the production of VSC have been reported and many of these bacteria are commonly suspected periodontal pathogens. The aim of this study was to estimate the change of the VSC concentration after periodontal treatment, Twenty subjects with probing depth $(PD)\;{\geq}5mm$ (experimental group) and 20 subjects with PD<5mm (control group) participated. VSC concentration measurement was made with gas chromatography. VSC concentration was measured at pre-treatment, 2 weeks after scaling and 1 month after periodontal treatment(root planning and flap operation). Maximum probing depth and bleeding on probing(BOP) were also examed at pretreatment and 1 month after periodontal treatment, The conclusions were as follow: 1. In the experimental group VSC concentration and CH3SH/H2S ratio were higher than control group. (p<0.05) 2. Both VSC concentration and CH3SH/H2S ratio showed decrease after periodontal treatment, But only CH3SH/H2S ratio after 1 month periodontal treatment was statistically significantly different from pre-treatment. (p<0.05) 3. CH3SH/H2S ratio tended to be on increase according to maximum probing depth and bleeding on probing. Periodontal disease could be a factor that caused oral malodor and oral malodor could be decreased after periodontal treatment.

Evaluating Ecotoxicity of Surface Water and Soil Adjacent to Abandoned Metal Mines with Daphnia magna and Eisenia fetida

  • Kim, Dae-Bok;Choi, Won-Suk;Hong, Young-Kyu;Kim, Soon-Oh;Lee, Sang-Woo;Lee, Byung-Tae;Lee, Sang-Hwan;Park, Mi-Jung;Kim, Sung-Chul
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.49 no.1
    • /
    • pp.81-86
    • /
    • 2016
  • Heavy metal pollution in agricultural fields at the abandoned metal mines has been serious problems in Korea. In order to manage heavy metal pollution in surface water and soil, numerous remediation strategies have been established. Therefore, main purpose of this research was to examine feasibility of ecological toxicity assessment for establishing management strategy in heavy metal polluted agricultural fields. Heavy metal concentration in surface water and soil was monitored along with ecotoxicity experiment with Daphnia magna and Eisenia fetida. Result showed that high toxicity was observed in heavily polluted agricultural field with heavy metals. In case of mortality of Daphnia magna (85%) and Eisenia fetida (6.7%), the highest ratio was observed when heavy metal concentration in surface and soil was high. Calculated ecotoxicity index (EI) ranged 0.06-0.30 and the highest EI was observed in heavily polluted sites among 5 abandoned metal mines. Overall, ecological toxicity assessment is necessary to evaluate heavy metal pollution in agricultural fields near at the abandoned metal mines along with chemical concentration analysis.

Membrane Process Development for $CO_2$ Separation of Flaring Gas (Flaring 가스의 $CO_2$ 분리를 위한 분리막 공정 기술개발)

  • Kim, Se Jong;Kim, Hack Eun;Cho, Won Jun;Ha, Seong Yong
    • Membrane Journal
    • /
    • v.23 no.5
    • /
    • pp.384-391
    • /
    • 2013
  • We prepared composite membrane which was made with polysulfone supported hollow fiber membrane coated with Hyflon AD to eliminate $CO_2$ gas from mixed-gases which were generated in DME manufacturing processes. The performance of module about simulated flaring gas was measured by using manufactured composite membrane. 1-stage evaluation result shows $CO_2$ concentration was below 3% at 1.2 MPa and at Stage cut 0.24 above. In addition $CO_2$ removal rate and $CH_4$ recovery rate was 80% respectively at the same condition. 2-stage evaluation result shows, when the $CO_2$ concentration of product gas was fixed at 5%, recycled $CO_2$ at stage cut 0.074 had the same concentration as the feed gas and the recovery rate of $CH_4$ was 99% at the moment.

Changes in Chemical Composition of Korean Red Ginseng (Panax ginseng C.A. Meyer) Extract With Alcohol Extraction

  • Shin, Kwang-Soon;Oh, Sung-Hoon;Kim, Tae-Young;Yoon, Brian;Park, Sung-Sun;Suh, Hyung-Joo
    • Preventive Nutrition and Food Science
    • /
    • v.13 no.3
    • /
    • pp.212-218
    • /
    • 2008
  • We extracted red ginseng with various alcohol concentrations and evaluated total carbohydrate, uronic acid, polyphenols compounds and ginsenoside contents, and yields of alcohol extract. The water extraction (0% alcohol extraction) showed a high level of total carbohydrate content. 10% and 20% alcohol extraction showed the highest uronic acid contents (7,978.8 and $7,872.7\;{\mu}g/mL$ of extract, respectively). The efficiency order of the red ginseng extract (RGE) preparations in liberating polyphenols was: $0{\sim}50%$ alcohol${\geq}\;60%$ alcohol> $70{\sim}90%$ alcohol. Solid contents in RGE were decreased with increased alcohol concentration; the same tendency as with the results of total carbohydrate content. Total ginsenoside contents in $20{\sim}50%$ alcohol extracts showed similar levels ($442,962.9{\sim}47,930.8\;{\mu}g/mL$ of extract). Water extraction showed the lowest ginsenoside content ($14,509.4\;{\mu}g/mL$ of extract). The ginsenoside contents at above 60% alcohol were decreased with increased alcohol concentration. Generally, ginsenoside (Rg2, Rg1, Rf, Re, Rd, Rb2, Rc and Rb1) contents were increased with increased alcohol concentrations. However, Rg3 content was decreased with increases in alcohol concentration.

Effect of Bacteria in Soil on Microbiologically Influenced Corrosion Behavior of Underground X65 Pipeline (토양 속 박테리아가 지하매설 X65 배관의 미생물 부식 거동에 미치는 영향)

  • Choe, Byung Hak;Han, Sung Hee;Kim, Dae Hyun;Kim, Woosik;Kim, Cheolman;Choi, Kwang Su
    • Korean Journal of Materials Research
    • /
    • v.32 no.3
    • /
    • pp.168-179
    • /
    • 2022
  • Microbiologically Influenced Corrosion (MIC) occurring in underground buried pipes of API 5L X65 steel was investigated. MIC is a corrosion phenomenon caused by microorganisms in soil; it affects steel materials in wet atmosphere. The microstructure and mechanical properties resulting from MIC were analyzed by OM, SEM/EDS, and mapping. Corrosion of pipe cross section was composed of ① surface film, ② iron oxide, and ③ surface/internal microbial corrosive by-product similar to surface corrosion pattern. The surface film is an area where concentrations of C/O components are on average 65 %/16 %; the main components of Fe Oxide were measured and found to be 48Fe-42O. The MIC area is divided into surface and inner areas, where high concentrations of N of 6 %/5 % are detected, respectively, in addition to the C/O component. The high concentration of C/O components observed on pipe surfaces and cross sections is considered to be MIC due to the various bacteria present. It is assumed that this is related to the heat-shrinkable sheet, which is a corrosion-resistant coating layer that becomes the MIC by-product component. The MIC generated on the pipe surface and cross section is inferred to have a high concentration of N components. High concentrations of N components occur frequently on surface and inner regions; these regions were investigated and Na/Mg/Ca basic substances were found to have accumulated as well. Therefore, it is presumed that the corrosion of buried pipes is due to the MIC of the NRB (nitrate reducing bacteria) reaction in the soil.

Influence of Heavy Metal on Riparian Vegetation in Downstream Areas of Disused Metal Mines (폐금속광산지역의 하천퇴적물에서 중금속이 식물에 미치는 영향에 관한 연구)

  • Ahn, Tae Woong;Lee, Joung An;Oh, Jong Min
    • Journal of Environmental Impact Assessment
    • /
    • v.18 no.4
    • /
    • pp.209-218
    • /
    • 2009
  • The purpose of this study was to accumulation of the heavy metals by riparian vegetation throughout analysis of the heavy metal concentration in riparian vegetation, water, and sediment near mine drainage. According to analyzing concentration of the heavy metals in riparian vegetation, water, and sediment the heavy metal was indicated at the leaf significantly. Compared with the concentration of sediment soil, the maximum concentration of the As, Cd, CN, Pb, Zn was higher 2.6, 2.6, 25, non-detect, and 15 times in leaf. Also those concentration have 9.6, 16.6, 25, 1.6, and 25 times in root. As the results, the author can know the sediment has a very relative to vegetation in mine drainage. because, the increasing of concentration of heavy metal in sediment gives the more accumulative concentration of heavy metal in vegetation. Compared with the concentration of conta minated site and non-contaminated site. As, Cd, CN, Pb, Zn the maximum concentration in sediment soil was higher 5.7, 258.1, 10.9, 370.0, and 298.3 times respectively. In case of vegetation, the maximum concentration of the As, Cd, CN, Pb, Zn was higher 5.6, 62.3, 5.0, non-detect, and 30.6 times in leaf. Also those concentration have 8.5, 63.3, 2.6, 60.7, and 62.1 times in root. In this study, the author can surmise that there indicated a lot of adsorption with the heavy metal concentration in contaminated mine drainage.