• Title/Summary/Keyword: Coronary

Search Result 2,281, Processing Time 0.032 seconds

CT Imaging Findings in Non-Atherosclerotic Coronary Artery Disease (다양한 비죽상경화 관상동맥 질환의 CT 영상 소견)

  • Jongmin Park;Byunggeon Park;Eun-Ju Kang;Jongmin Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.1
    • /
    • pp.70-83
    • /
    • 2022
  • Acute coronary syndrome (ACS) is mainly caused by atherosclerotic coronary artery disease (CAD); however, it can also occur in patients with non-atherosclerotic CAD. Conventional coronary angiography only shows the lumen of arteries, indicating the presence of stenosis or dilatation. Thus, it has limited value in evaluating the coronary artery wall and offers low specificity for diagnosing CAD. Coronary CT angiography provides additional information, including the depiction of the concerned vessel and the aorta, as well as the pulmonary artery, which permits the diagnosis of non-atherosclerotic CAD and the differentiation of various causes of the disease. In this review, we present the pathophysiology and CT imaging features of non-atherosclerotic CAD.

The Influence of Heart Rate and Coronary Calcification on the Diagnostic Accuracy of 64-slice Multidetector Cardiac CT in Coronary Artery Disease (심박동수 및 관상동맥 석회화가 64 절편 다중검출기 심장 CT의 관상동맥 질환 진단일치도에 미치는 영향)

  • Kang, Yeong-Han;Park, Jong-Sam
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.339-347
    • /
    • 2009
  • Purpose : This study was to investigate the influence of heart rate and coronary calcification on diagnostic accuracy of 64-slice multidetector CT(MDCT) in coronary artery disease. Methods : 178 patients(84 men, 94 women) undergoing cardiac CT were included in this study. 3 coronary arteries(LAD, LCX, RCA) were assessed the presence of significant stenosis($\geq50%$) and the results compared with those of coronary angiography. Results : On a patient-based analysis, the diagnostic accuracy of 64-slice MDCT was 96.6%. The diagnostic accuracy on left anterior descending, left circumflex, right coronary artery were 86.5%, 84.3%, 92.1% respectively. Body mass index and blood pressure were not influenced on diagnostic accuracy of 64-slice MDCT. In less than 60/min of heart rate, accuracy was 90.1% and $\kappa$ value was 0.78. While in more than 70/min of heart rate, accuracy was 75.8% and $\kappa$ value was 0.52. In less than 100 of coronary calcification, accuracy was 91.3% and $\kappa$ value was 0.81. While in more than 400, accuracy was 68.6% and $\kappa$ value was 0.33. Conclusion : 64-slice MDCT shows similar diagnostic accuracy as coronary angiography. But in the context of more than 70/min of heart rate and 400 of coronary calcification, diagnostic accuracy was decreased. So there needs to identify heart rate and coronary calcification in cardiac CT, and if heart rate shows more than 70/min, use beta-blocker to regulate it.

Coronary artery diameter of normal children aged 3 months to 6 years (생후 3개월에서 7세 미만 정상 소아에서의 관상동맥 직경)

  • Yu, Jeong Jin;Cho, Suk Kyung;Park, Yong-Mean;Lee, Ran;Chung, Sochung;Bae, Sun Hwan
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.6
    • /
    • pp.629-633
    • /
    • 2008
  • Purpose : This study was designed to investigate normal domestic values for the diameter of the left main coronary artery (LCA), the left anterior descending coronary artery (LAD) and the right coronary artery (RCA). These data are necessary to define dilatation of coronary arteries in Kawasaki disease cases. Methods : Study subjects were 43 normal healthy children whose ages ranged from 3 months to 6 years. They children visited Konkuk University hospital for echocardiograph examination between March 2005 and November 2007. Measurements of coronary arterial diameters at each branch were done by off-line analyses of recorded images. Simple regression analysis of each the measurements were performed using the body size (body surface area, etc.) as the independent variable. Results : Body surface area was significantly related to the diameters of LCA ($r^2=0.20$, P=0.0038), of LAD ($r^2=0.41$, P<0.0001), and of RCA ($r^2=0.30$, P=0.0002). In the regression model, the estimates of the y-intercept were 1.703, 1.058, and 1.007; the estimates of the regression coefficient were 0.971, 1.175, and 1.177; and the estimates of the standard deviation were 0.315, 0.221, and 0.282 with respect to the three coronary arteries. Conclusion : A the linear regression model of the diameters of three coronary arteries adjusted for body surface area was produced. With these results, the Z-score calculation of the diameter of three coronary arteries, based on normal domestic data, will be possible.

Operation of Coronary AV Fistula: a report of a case (관상동맥정맥루의 외과적 수술 1례)

  • Sim, Yeong-Mok;Hong, Jang-Su;Suh, Kyung-Pill
    • Journal of Chest Surgery
    • /
    • v.14 no.1
    • /
    • pp.91-94
    • /
    • 1981
  • Coronary arterial fistula was first described by Krause in 1865. Since then more than 200 examples of this lesion have been reported In the literature. It is relatively rare disease and it more commonly originate in the right than in the left coronary artery. A 9-year old male was admitted with the chief complaint of cardiac murmur and diagnosed as coronary A-V fistula at middle segment of the right coronary artery by cardiac catheterization and aortography. On the operation field, the right coronary artery was markedly dilated as one cm. in diameter from the aorta to the middle segment at acute angle of the right ventricle. Fistula opening was obliterated by one stitch horizontal mattress suture with pledget. Postoperative course was uneventful and discharged without problem.

  • PDF

Right Coronary Artery Fistula and Occlusion Causing Myocardial Infarction after Blunt Chest Trauma

  • Kim, Kun Il;Lee, Won Yong;Ko, Ho Hyun;Kim, Hyoung Soo;Lee, Hee Sung
    • Journal of Chest Surgery
    • /
    • v.47 no.4
    • /
    • pp.402-405
    • /
    • 2014
  • Myocardial infarction (MI) secondary to coronary artery fistula and the subsequent occlusion of the distal right coronary artery (RCA) after blunt chest trauma is a rare entity. Here, we describe a case of coronary artery fistula and occlusion with an inferior MI that occurred following blunt chest trauma. At the initial visit to the emergency room after a car accident, this patient had been undiagnosed with acute myocardial infarction, readmitted five months after ischemic insult, and revealed to have experienced MI due to RCA-right atrial fistula and occlusion of the distal RCA. He underwent coronary surgery and recovered without complications.

Two-Dimensional Image-Based Respiratory Navigator for Free-Breathing Coronary Magnetic Resonance Angiography

  • Shin, Taehoon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.1
    • /
    • pp.71-77
    • /
    • 2018
  • Purpose: To develop a two-dimensional (2D) image-based respiratory motion correction technique for free-breathing coronary magnetic resonance angiography (MRA). Materials and Methods: The proposed respiratory navigator obtained aliased a 2D sagittal image from under-sampled k-space data and utilized motion correlation between the aliased images. The proposed navigator was incorporated into the conventional coronary MRA sequence including the diaphragm navigator and tested in three healthy subjects. Results: The delineation of major coronary arteries was significantly improved using the proposed 2D motion correction (S/I and A/P) compared to one-dimensional (S/I) correction using the conventional diaphragm navigator. Conclusion: The 2D image-based respiratory navigator was proposed for free-breathing coronary angiography and showed the potential for improving respiratory motion correction compared to the conventional 1D correction.

Unroofed Coronary Sinus Syndrome with Valvular Disease - Report of A Case - (판막질환을 동반한 관상정맥동 천정결손 증후군 - 수술 치험 1례 -)

  • 박성달
    • Journal of Chest Surgery
    • /
    • v.23 no.1
    • /
    • pp.162-168
    • /
    • 1990
  • Unroofed coronary sinus syndrome is an uncommon anomaly which is caused by incomplete formation of the left atriovenous fold and it is usually associated with persistent left superior vena cava. It may be diagnosed by cardiac catheterization and cineangiography but, if it is not diagnosed, it can bring out significant complications due to right to left shunt, such as brain abscess, cerebral embolism, transient ischemic attack, arterial desaturation and there will reduced patient`s life expectancy. Therefore corrective operation was needed. A case of unroofed coronary sinus syndrome which combines with valvular heart disease was experienced at the department of thoracic & cardiovascular surgery of Kosin medical college. The patient was 49 years old female and she complained dyspnea on exertion for 2 yrs. Cardiac catheterization with cineangiography and both superior venacavogram were performed for diagnosis and she was diagnosed as unroofed coronary sinus syndrome combined with mitral and tricuspid regurgitation. Surgical correction was accomplished by reroofing of coronary sinus with pericardial patch, closure of atrial septal defect and annuloplasty of both atrioventricular valves. Postoperative results were satisfactory and course of recovery was uneventful. We report a case of unroofed coronary sinus syndrome with review.

  • PDF

Coronary Artery Fistula Associated with Valvular Heart Disease (심장판막증에 동반된 관상동맥루 -1례 보고-)

  • 백완기
    • Journal of Chest Surgery
    • /
    • v.23 no.1
    • /
    • pp.158-161
    • /
    • 1990
  • A congenital coronary artery fistula is an uncommon anomaly which has a direct communication between a coronary artery and the lumen of any one of the four cardiac chambers, or the coronary sinus, or its tributary veins or the superior vena cava. The right coronary artery is involved most frequently, and the abnormal communication in most often is to the right ventricle followed in incidence by drainage into the right atrium and the pulmonary artery. Recently. we experienced a case of congenital coronary artery fistula associated with valvular heart disease. The fistulous communication was noted between the left circumflex artery and the left atrial appendage. Under the cardiopulmonary bypass, the internal obliteration of the left atrial appendage, mitral valve replacement, and aortic valve exploration were accomplished. Postoperative hospital course was uneventful and the patient was discharged without any problems.

  • PDF

관상정맥동 천정결손증 3례 보고

  • 임창영;김요한;이인성;김광택;김형묵
    • Journal of Chest Surgery
    • /
    • v.20 no.1
    • /
    • pp.218-222
    • /
    • 1987
  • Unroofed coronary sinus syndrome is an uncommon anomaly, Unroofed coronary sinus syndrome is caused by incomplete formation of the left atriovenous fold, and it usually is associated with Left SVC. If it is not diagnosed, a residual reversed or bidirectional shunt will result, and its complications will reduce life expectancy. We experienced 3 cases of unroofed coronary sinus syndrome which combines TOF with PLSVC, partial ECD, primum type ASD. In case of Unroofed coronary sinus syndrome which combines TIF with PLSVC, preoperative diagnosis was not made. In corrective operation for TOF of this case, pump weaning was failed due to hypoxia and cardiac arrest, and he expired at operation room. At autopsy of this case, complete unroofed coronary sinus was found. In the other 2 cases, partial unroofed coronary sinus syndrome was found in operation field and corrective operation was performed successfully. We report these 3 experiences with its review. ^u ++ Noninvasive Assessment of Pressure Gradients across Prosthetic Heart Valve by Doppler Ultrasound - A comparative study of the Duromedics Bileaflet Valves in mitral position and Normal Mitral Valves -with its review.

  • PDF

Flexibile Analysis of Coronary Stents due to Loading Directions (하중 방향에 따른 관상동맥용 스텐트의 유연성 해석)

  • 조승관;조은정;김한성
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.331-334
    • /
    • 2004
  • In clinical use, coronary stents keep coronary arteries open after expansion with a balloon catheter and prevent the expanded artery from collapsing. Coronary stents are positioned in artery by catheter with a balloon along a guide wire to the lesion site. Flexibility is one of important ability for delivery. In this paper, Palmaz-Schatz stent and Tenax complete stent were selected because these are the most representative of tubular stents. Finite element analyses for the stent system were performed using ABAQUS/Standard code. The present study estimated the flexibility of coronary stents due to loading directions. Moreover the present paper suggests a numerical method to test the flexibility of stents. In conclusion this paper shows how the finite element analysis can be effectively organized in the stent development.

  • PDF