• Title/Summary/Keyword: Coronal plane

Search Result 139, Processing Time 0.022 seconds

The usability of the image according to the frequency encoding gradient direction conversion in fixation using the non magnetic metal screw (비 자성 금속 screw를 이용한 고정술에서 주파수 부호화 경사 방향 변환에 따른 영상의 유용성)

  • Cho, Jae-Hwan;Lee, Hae-Kag;Park, Cheol-So
    • Journal of Digital Contents Society
    • /
    • v.12 no.1
    • /
    • pp.49-55
    • /
    • 2011
  • Because of causing the geometrical transformation of the magnetic field, the patient implementing the fixation using the nonmagnetic metal screw causes the magnetic susceptibility artifact at an image. Thus, in this research, the distortion measure of the image according to the frequency oblique direction conversion tried to be compared in the magnetic susceptibility artifact occurence. First, the itself phantom inserting the nonmagnetic metal screw of the titanium component was made and the region of interest was set up and the frequency oblique direction the anterior - back side was converted to the right-to-left direction in the axial image and a right-to-left was converted to the upper side - bottom side in the coronal plane and the upper - bottom side was converted to the anterior - back side in the sagittal plane and the distortion measure of the region of interest was compared, it observed. In a result, when converting the frequency oblique direction, the distortion difference of the region of interest could be confirmed and it is considered to enhance the diagnostics efficiency changing the oblique direction appropriately.

The Effects Where the Stroke Shoes Which Use Functional Electric Stimulation Goes Mad to Walking of the Hemiplegia (기능적 전기자극 치료기를 이용한 중풍구두가 편마비 환자의 보행에 미치는 영향)

  • Kim, Jeong-Seon;Park, Ji-Whan
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.13 no.1
    • /
    • pp.36-43
    • /
    • 2007
  • Purpose: An objective analysis and observations were to be done on hemiplegia patients that are wearing a walking support device, Stroke shoes. Their improvements in walking pace, the reduction of distance between the two knee joint, the increase of curve angle of the knee joint and their steps and the reduction of ankle joint upon swing phase were analyzed using a 20 walking analyzer. Methods: An examination was carried out to see the patients' communication skill and independent walking and then let them walk with the Stroke shoes on to get results before and after wearing it. Simi Reality Motion Systems GmbH (Germany, 2007) was used to analyze the results regarding knee joint and ankle joint angle changes of sagitta plane and coronal plane, stepping distances, distances between the knees and walking pace. Results: 1. The articulation angle of ankle joint during swing phase decreased and knee joint has shown a statistically significant increase in such value(p<0.05). 2. Only knee joint showed a significant increase in articulation angle during heel strike(p<0.05). 3. Knee joint showed a significant increase in articulation angle during toe off(p<0.05). 4. The distance between the two knees as well as their foot steps significantly decreased compared with when Stroke shoes were not worn(p<0.05). 5. Stroke shoes with FES have shown positive effects on the patients in improving their walking styles overall. (p<0.05). Conclusion: There was an improvement in rotation walking pattern by a reduction in the distance between the knees after wearing Stroke shoes with FES. Plantar flexion reduced that occurred in ankle joint during walking and flexion angle increased in knee joint, both of which improved foot drop which was a major problem in hemiplegia patients. Also it is believed that the device will have some positive influences on knee joint stiffening paralysis to aid in improving inefficient walking phases.

  • PDF

The Effects of Maintained Muscle Contraction of Abdominal and Pelvic Floor Muscles on 3D Pelvic Stability in Individuals with Chronic Low Back Pain During Gait

  • Yu, Min;Choi, Yu-Ri;Choi, Jeong-Eun;Jeon, Seong-Yeon;Kim, Yong-Wook
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.17 no.3
    • /
    • pp.23-30
    • /
    • 2022
  • PURPOSE: This study was designed to investigate the effects of keeping contraction of abdominal and pelvic floor muscles on 3D pelvic stability in individuals with nonspecific chronic low back pain (CLBP) during normal speed walking. METHODS: The subjects were 20 adults with CLBP deformity and had moderate pain intensity of the visual analog scale. A three-dimensional camera capture system was used to collect kinematic pelvic motion data with and without contraction of the abdominal and pelvic floor muscles during gait. The subjects were asked to walk on a walkway in the lab room and they were attached 40 reflective markers to their pelvic segment and lower extremities. A Visual3D Professional V6 program and Vicon Nexus software were used to analyze 3D pelvic kinematic data. RESULTS: There were significant differences between with and without contraction of the abdominal and pelvic floor muscles of the pelvic depression and the total pelvic motion in coronal plane during gait (p < .05). However, there were no significant differences in any of the maximal motion of the pelvic segment in sagittal and transverse motion plane according to the different muscle contraction conditions (p > .05). CONCLUSION: The results of this study suggest that maintaining co-contraction of the abdominal and pelvic floor muscles in individuals with CLBP increased pelvic stability and contributed to preventing excessive pelvic movements during gait.

Assessment of Imaging Distortion in Magnetic Resonance Imaging for Stereotactic Radiosurgery: Through Phantom Study (뇌정위 방사선수술 시스템을 위한 자기공명영상의 공간적 왜곡의 측정 : 모형실험을 통한 연구)

  • 박선원;한문희;김동규;정현태;송인찬
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.1
    • /
    • pp.7-13
    • /
    • 2000
  • Purpose : To assess the distortion of MRI with the Leksell stereotactic radiosurgery system in variable pulse sequence and imaging plane through phantom study, to find most adequate imaging plane and pulse sequence for stereotactic radiosurgery system. Materials and methods : We made the phantoms for MRI and get images in variable conditions and analyzed the image distortion using image analysis program, and statistically using paired student t-test. Results : The transeverse plane images had acceptable error ranges bless than 1.5mm) in all pulse sequence in both the analysis of fiducial marker in stereotactic G-frame and the phantom study. The coronal plane images had unacceptable large errors (more than 1.7mm) in the analysis of fiducial marker in the stereotactic G-frame, but had corrected small errors (less than 1.5mm) in the phantom study. Conclusion : We find from the phantom study that the present MR machines are adequate for stereotactic surgery system in frequently used pulse sequences, and imaging planes.

  • PDF

Condylar positioning changes following unilateral sagittal split ramus osteotomy in patients with mandibular prognathism

  • Kim, Myung-In;Kim, Jun-Hwa;Jung, Seunggon;Park, Hong-Ju;Oh, Hee-Kyun;Ryu, Sun-Youl;Kook, Min-Suk
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.37
    • /
    • pp.36.1-36.7
    • /
    • 2015
  • Background: This study was performed to evaluate three-dimensional positional change of the condyle using three-dimensional computed tomography (3D-CT) following unilateral sagittal split ramus osteotomy (USSRO) in patients with mandibular prognathism. Methods: This study examined two patients exhibiting skeletal class III malocclusion with facial asymmetry who underwent USSRO for a mandibular setback. 3D-CT was performed before surgery, immediately after surgery, and 6 months postoperatively. After creating 3D-CT images by using the In-vivo $5^{TM}$ program, the axial plane, coronal plane, and sagittal plane were configured. Three-dimensional positional changes from each plane to the condyle, axial condylar head axis angle (AHA), axial condylar head position (AHP), frontal condylar head axis angle (FHA), frontal condylar head position (FHP), sagittal condylar head axis angle (SHA), and sagittal condylar head position (SHP) of the two patients were measured before surgery, immediately after surgery, and 6 months postoperatively. Results: In the first patient, medial rotation of the operated condyle in AHA and anterior rotation in SHA were observed. There were no significant changes after surgery in AHP, FHP, and SHP after surgery. In the second patient, medial rotation of the operated condyle in AHA and lateral rotation of the operated condyle in FHA were observed. There were no significant changes in AHP, FHP, and SHP postoperatively. This indicates that in USSRO, postoperative movement of the condylar head is insignificant; however, medial rotation of the condylar head is possible. Although three-dimensional changes were observed, these were not clinically significant. Conclusions: The results of this study suggest that although three-dimensional changes in condylar head position are observed in patients post SSRO, there are no significant changes that would clinically affect the patient.

Formulation of a reference coordinate system of three-dimensional head & neck images: Part II. Reproducibility of the horizontal reference plane and midsagittal plane (3차원 두부영상의 기준좌표계 설정을 위한 연구: II부 수평기준면과 정중시상면의 재현성)

  • Park, Jae-Woo;Kim, Nam-Kug;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.35 no.6 s.113
    • /
    • pp.475-484
    • /
    • 2005
  • This study was performed to investigate the reproducibility of the horizontal and midsagittal planes, and to suggest a stable coordinate system for three-dimensional (3D) cephalometric analysis. Eighteen CT scans were taken and the coordinate system was established using 7 reference points marked by a volume model, with no more than 4 points on the same plane. The 3D landmarks were selected on V works (Cybermed Inc., Seoul, Korea), then exported to V surgery (Cybermed Inc., Seoul, Korea) to calculate the coordinate values. All the landmarks were taken twice with a lapse of 2 weeks. The horizontal and midsagittal planes were constructed and its reproducibility was evaluated. There was no significant difference in the reproducibility of the horizontal reference planes, But, FH planes were more reproducible than other horizontal planes. FH planes showed no difference between the planes constructed with 3 out of 4 points. The angle of intersection made by 2 FH planes, composed of both Po and one Or showed less than $1^{\circ}$ difference. This was identical when 2 FH planes were composed of both Or and one Po. But, the latter cases showed a significantly smaller error. The reproducibility of the midsagittal plane was reliable with an error range of 0.61 to $1.93^{\circ}$ except for 5 establishments (FMS-Nc, Na-Rh, Na-ANS, Rh-ANS, and FR-PNS). The 3D coordinate system may be constructed with 3 planes; the horizontal plane constructed by both Po and right Or; the midsagittal plane perpendicular to the horizontal plane, including the midpoint of the Foramen Spinosum and Nc; and the coronal plane perpendicular to the horizontal and midsagittal planes, including point clinoidale, or sella, or PNS.

Effects of the Flex-OA Functional Shoe and the Standardized Shoe on Ranges of Hip and Knee Joint During Gait in Healthy Individuals (정상 성인에서 Flex-OA 기능성 신발과 일반 신발이 보행 중 엉덩관절과 무릎관절의 가동범위에 미치는 효과)

  • Kim, Yongwook
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.6 no.3
    • /
    • pp.33-42
    • /
    • 2018
  • Purpose : The purpose of this study was to investigate the characteristics of the Flex-OA shoe, a specific functional shoe, in terms of the range of motion (ROM) of hip and knee joint during walking when compared to a standardized shoe. Methods : Twenty-six healthy adults (18 males, 6 females) participated in this study. Subjects performed 8 walking trials consisting of two different shoe conditions to evaluate the hip and knee ROM using a three-dimensional motion capture system. Visual 3D motion analysis software was finally used to coordinate the kinematic data. Result : The total ROM and maximal abduction range of the hip joint in the coronal planes when wearing the Flex-OA shoe were significantly increased during walking compared to wearing a standard shoe (p<.05). On the other hand, significantly increased ROM was observed in the sagittal plane when wearing the Flex-OA shoe in the knee joints compared to a standard shoe (p<.05). Conclusion : Although clinical application of the specific functional shoe has known clearly positive effects on knee moments, the results of this study could provide important clues to explain the background of these effects in terms of the hip and knee joints when applying a specific functional shoe.

Ultrasonographic evaluation of extrusion of medial meniscus of the knee -A Case Report- (초음파를 이용한 슬관절 내측 반월상 연골 탈출의 진단 -1례 보고-)

  • Kim, Jung Man;Song, Chol
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.1 no.1
    • /
    • pp.14-17
    • /
    • 2008
  • Meniscal extrusion is defined as a distance of 3 mm or more between the peripheral border of the meniscus and the edge of the tibial plateau on the coronal plane, associated with degeneration or tear of meniscus, effusion, osteophyte, osteoarthritis. There are many advantages of ultrasonography, including cost, dynamic real-time assessment. We evaluated a patient with anteromedial mass of the knee by ultrasonography, which was proved to be the extrusion of medial meniscus. We report a case of extrusion of medial meniscus evaluated by ultrasonography with review of the related literatures.

  • PDF

Stress distribution of oval and circular fiber posts in amandibular premolar: a three-dimensional finite element analysis

  • Er, Ozgur;Kilic, Kerem;Esim, Emir;Aslan, Tugrul;Kilinc, Halil Ibrahim;Yildirim, Sahin
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.434-439
    • /
    • 2013
  • PURPOSE. The aim of the present study was to evaluate the effects of posts with different morphologies on stress distribution in an endodontically treated mandibular premolar by using finite element models (FEMs). MATERIALS AND METHODS. A mandibular premolar was modeled using the ANSYS software program. Two models were created to represent circular and oval fiber posts in this tooth model. An oblique force of 300 N was applied at an angle of $45^{\circ}$ to the occlusal plane and oriented toward the buccal side. von Mises stress was measured in three regions each for oval and circular fiber posts. RESULTS. FEM analysis showed that the von Mises stress of the circular fiber post (426.81 MPa) was greater than that of the oval fiber post (346.34 MPa). The maximum distribution of von Mises stress was in the luting agent in both groups. Additionally, von Mises stresses accumulated in the coronal third of root dentin, close to the post space in both groups. CONCLUSION. Oval fiber posts are preferable to circular fiber posts in oval-shaped canals given the stress distribution at the postdentin interface.

Comparison of 3-D structures of Halo CMEs using cone models

  • Na, Hyeon-Ock;Moon, Y.J.;Jang, Soo-Jeong;Lee, Kyoung-Sun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.1
    • /
    • pp.95.1-95.1
    • /
    • 2012
  • Halo coronal mass ejections (HCMEs) are major cause of geomagnetic storms and their three dimensional structures are important for space weather. In this study, we compare three cone models: an elliptical cone model, an ice-cream cone model, and an asymmetric cone model. These models allow us to determine the three dimensional parameters of HCMEs such as radial speed, angular width, and the angle (${\gamma}$) between sky plane and cone axis. We compare these parameters obtained from three models using 62 well-observed HCMEs from 2001 to 2002. Then we obtain the root mean square error (RMS error) between maximum measured projection speeds and their calculated projection speeds from the cone models. As a result, we find that the radial speeds obtained from the models are well correlated with one another (R > 0.84). The correlation coefficients between angular widths are less than 0.53 and those between ${\gamma}$ values are less than 0.47, which are much smaller than expected. The reason may be due to different assumptions and methods. The RMS errors of the elliptical cone model, the ice-cream cone model, and the asymmetric cone model are 213 km/s, 254 km/s, and 267 km/s, respectively. Finally, we discuss their strengths and weaknesses in terms of space weather application.

  • PDF