• Title/Summary/Keyword: Corona

Search Result 1,313, Processing Time 0.032 seconds

The Simulation of Corona Charging Process in Polytetrafluoroethylene Electret using Finite Element Method (유한요소법을 이용한 PTFE 일렉트렛트의 코로나 대전 과정 시뮬레이션)

  • 이수길;유재웅;박건호;김충혁;이준웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1994.05a
    • /
    • pp.94-98
    • /
    • 1994
  • In this study, the thermally stimulated current(TSC) of corona charged PTFE film was studied and the simulation of corona charging process was also calculated by finite element method. The electrets which were formed by appling high voltages(DC-5∼-8[kV]) to PTFE film were experimented to measure TSC in the temperature range of -100∼+200 [$^{\circ}C$] and then the finite element method was accomplished to examine corona charging process using a obtained physical constants. It is confirmed that the charging negative corona is profitable as the applications are manufactured because the time constant of negative corona is much larger than it of positive corona. And it is attempted to estimate the corona charging process in space using simulation.

  • PDF

Analysis Techniques of Corona Discharges in Air with Needle-Plane Electrode System (침-평판 전극 구조에서 발생하는 기중 코로나 방전의 해석 기법)

  • 강성화;박영국;권순석;정수현;류부형;임기조
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.4
    • /
    • pp.49-53
    • /
    • 1996
  • Corona discharges in air insulated electric power systems cause power loss, produce interfering electromagnetic radiation, and can indicate incipient failure. An understanding of corona discharges in air gap is clearly Important. The Wavelet transformation is an extended method of fourier transformation. The fourier method is a powerful tool for signal analysis, but it can't include information for time. However the wavelet transformation analysis can include on the information of time and frequencies at the same time. In this paper we apply the wavelet transformation to the corona signals in needle-plane air gap for the purpose of analysis of developing aspects of corona discharges. We analyzed the developing aspects of corona discharges, namely, corona discharge current, repetition rates, width of Pulse distribution region, pulseless region and frequencies distribution of corona discharge pulses.

  • PDF

The Characteristics of the Ionic Wind Generation with Corona Electrodes Installed in Form of the Ring (환형 배치된 코로나 전극에 의한 이온풍 발생 특성)

  • Kim, Jin-Gyu;Jung, Jae-Seung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.2
    • /
    • pp.54-59
    • /
    • 2014
  • The electric power can be converted into the mechanical power by a corona discharge system. This way has not stronger force than a electric motor. But it has been applied in various industrial fields because of many advantages, no moving parts, smaller noise, simpler structure, minimizing et al. In this paper, corona discharge system with multiple corona electrode installed in form of the ring, has been studied by focusing on the electrical and mechanical characteristics. Intensity of the corona discharge depends on applied electric field, and electric field is related to the applied voltage, discharge gap spacing(s), distance between each corona electrodes(d). As a result, in the case d/s=0.9, most intensive discharge occurred in this experiments. In the region of d/s<0.9, ionic wind velocity has saturation value in spite of decreasing corona current, because each ion velocities increase by the increasing electric field.

Assessment of the Electrical Environmental Characteristics to Decide Optimal Bundle Type for HVDC ${\pm}500kV$ Overhead Transmission Lines (HVDC ${\pm}500kV$ 가공 송전선로의 최적 도체방식 선정을 위한 전기환경특성 평가)

  • Ju, Mun-No;Kil, Gyung-Suk;Yang, Kwang-Ho;Lee, Sung-Doo;Hwang, Gi-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.11
    • /
    • pp.520-526
    • /
    • 2006
  • Corona interferences, such as radio noise, audible noise and television noise, need to be taken into account in the design of HVDC transmission line conductor configuration. Therefore the line designer requires data from which to estimate the corona performance of any set of conductors. To get a sufficiently complete set of design data, it is necessary to examine the corona test of a large number of conductor geometries. This paper presents the results of corona cage test among three types of candidate conductors. It is quite clear from test results that the conductor geometries play an important role in establishing the magnitude of corona noise. Corona noise data from corona cage test are expressed as a statistical distribution of results obtained over long periods of time and various weather conditions. Therefore we can determine an environmentally-friendly conductor bundle for HVDC overhead transmission line. Based on this finding results, various simulations about HVDC line configurations, such as pole space and pole height, will be conducted. And then finally an optimal configuration for HVDC transmission line will be decided.

Corona Discharge Phenomena on the Dielectric Electrodes in High Field (고전계하에서 유전체 전극에 나타나는 코로나 현상)

  • Kim, Jung-Dal;Lee, Duck-Jin;Joo, Sung-Cheol;Jung, Jang-Gun;Chang, Gi-Hyuk;Lee, Sae-Hun
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1598-1600
    • /
    • 1998
  • When dielectric surface electric field exceed any electric field strength on air, corona discharge is occurred from the dielectric surface. This paper presents corona discharge phenomena on the dielectric in high field were studied under application of ${\pm}DC$ voltage, constitute of the point to plane 20mm gap. The results obtained in experimental are summarized as follow :(1) Corona pulse is appeared periodically after first corona pulse is occurred and the number of corona pulse increases with the instantaneous applied voltage but peak value is not changed greatly.(2)Applied voltage to beccrite and characteristics and peak value of current are almost a straight line. That kind of tendency accorded with characteristics of beccrite resistance.(3)In case of Positive corona, Positive streamers, were progressed greatly to plane electrodes but In case of negative corona, negative streamers smaller than that of Positive corona.

  • PDF

Taxonomic implications of floral morphology in the subfamily Asclepiadoideae (Apocynaceae s.l.) in Korea

  • NAM, Bo-Mi;CHUNG, Gyu Young
    • Korean Journal of Plant Taxonomy
    • /
    • v.48 no.3
    • /
    • pp.172-184
    • /
    • 2018
  • We examined the floral morphology of 15 taxa of five genera (Cynanchum, Marsdenia, Metaplexis, Tylophora, and Vincetoxicum) in Korean Asclepiadoideae using a stereoscopic and scanning electronic microscope to clarify and describe the floral characteristics. In this study, the corolla and corona types, the types of corona lobes, appendages on the corona lobes, and the apex shape of the style head are considered as diagnostic characteristics at the generic level. The genus Vincetoxicum, which is treated as a synonym of the genus Cynanchum in Korea, is distinguished from Cynanchum by the interstaminal part on the corona, fleshy and mainly triangular or ellipsoid corona lobes, and various corolla colors. In Cynanchum, various corona types have been observed, while Vincetoxicum have similar corona types among the taxa. In addition, the main floral characteristics at the species level were as follows: flowering time, inflorescence, corolla color, trichomes on the corolla surfaces, apex shape of the corona lobe, and trichomes on the ovary. This study presents the taxonomic importance of floral morphology by providing descriptions and diagnostic characteristics among the genera and species investigated.

The effect of magnet fields on the corona discharge (코로나 방전에 대한 자계의 영향)

  • 박재윤;정장근;김익균
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.3
    • /
    • pp.51-56
    • /
    • 2001
  • In this paper, the effect of magnetic field on corona discharge phenomena was experimentally investigated in the needle-plate electrode geometry. Needle-plate geometry discharge system with magnetic field at a right angle to the electric field was made. The corona discharge characteristics with magnetic field were investigated and compared with the corona characteristics without magnetic field in atmospheric pressure. As a result, in case of positive DC corona discharge with magnetic field, corona discharge zone was significantly wider, corona current was lower, and breakdown voltage was higher than those without magnetic field. However, in case of negative DC corona discharge with magnetic field, corona current was slightly higher and breakdown voltage was lower than those without magnetic field. It is thought that this result is due to cyclotron motion of charged particles such as electron and ion by magnetic field.

  • PDF

The Comparison of Adhesion Properties on Polyester Fabric by AC and DC Corona Treatment (AC와 DC 코로나 처리에 따른 폴리에스테르 직물의 접착성질 비교)

  • Lee, Jae Ho
    • Journal of Adhesion and Interface
    • /
    • v.17 no.3
    • /
    • pp.104-109
    • /
    • 2016
  • Compare AC corona and DC corona treatment effects, polyester fabrics were AC corona treated with different current intensity (5, 10, 15 A) and feeding speed (5, 10, 15 m/min) as the same DC corona treatment conditions of the preceding research. We confirmed the surface change of polyester fabrics using scanning electron microscopy (SEM) and X-ray photoelectron spectrometer (XPS), and the change of physical properties through measuring the dry and wet bonding strength. The surface changes of polyester fabrics by treating in air atmosphere with AC corona discharge are shown similar tendency with DC corona discharge. Generally dry bonding strength were increased with increasing current intensity and feeding speed, but wet bonding strength were increased with increasing current intensity and decreasing feeding speed in both AC and DC corona treatment. When the current is 20 A, carbonization occurs in DC corona discharge but carbonization does not occur in DC corona discharge.

Water Droplet Ejection Characteristics of a Wet Porous Point-Plate Airgap (다공성 수침-평판전극간의 수적 방출 특성)

  • Jung, Jae-Seung;Lee, Woo-Seok;Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.2005-2010
    • /
    • 2009
  • Water droplet ejection characteristics of a point-to-plate airgap, with a wet porous point as a corona electrode, has been investigated. And the water droplet traces, charge, mass and number were measured experimentally. More particles are observed with wet porous point than metal point because the corona-discharging wet porous point can eject a number of water droplets. The water droplets ejected from the positive-corona-discharging wet porous point showed very fine traces as compared with those from the negative-corona-discharging wet porous point. Moreover, the water droplets ejected from the AC-corona-discharging wet porous point showed granular-like larger traces. It was shown that the weak corona discharge can eject smaller water droplets with larger ratio of mass-to-charge than the intense corona discharge.

Characteristics of DC Surface Discharge for the Development of UV Camera (자외선 카메라 개발을 위한 직류 연면방전 특성)

  • Pang, Man-Sik;Choi, Jae-Hyeong;Kim, Woo-Jin;Kim, Young-Seok;Kim, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.5
    • /
    • pp.98-103
    • /
    • 2011
  • Recently, UV(ultra-violet rays) camera has attracted a great deal of interest from the view point of easy judgement in inspections and diagnoses of the safety of power equipment. Especilly, UV camera is applied the inspection of UV with corona discharge. One of the most important and difficult problems is the basic research of filter design, materials and corona discharge. In this paper, we will report on the UV generation, corona pulse count and the polarity effect of positive and negative DC surface discharge in air. Also, corona discharge characteristics are analyzed using prototype UV camera of Korea. UV generation and corona pulse count due to surface discharge in positive needle is higher than that of negative needle.