• 제목/요약/키워드: Corona

검색결과 1,314건 처리시간 0.033초

코로나 잡음 특성을 고려한 초고압 송전선의 다중도체배열방식 연구 (A Study on Multi-conductor Bundle for EHV Transmission Line Considering Corona Noise Characteristics)

  • 민석원;박종근
    • 대한전기학회논문지
    • /
    • 제39권5호
    • /
    • pp.508-515
    • /
    • 1990
  • This paper describes the corona characteristics of conductor bundle for EHV transmission line. To reduce the corona noise, the asymmetric conductor bundle to minimize the electric field of the conductor surface is proposed. The charge simulation method is used to formulate the electric field of conductor surface and the optimal arrangement of subconductor to minimize it is selected to apply the nonlinear successive quadratic programming. Through the analytical comparison and the corona cage test, it is proved that the asymmetric conductor bundle proposed in this paper can reduce the average maximum electric field of the phase conductors and the corona noise more than the conventional symmetric conductor bundle and asymmetric conductor bundle by GE.

  • PDF

Corona방전에 의한 유전체의 열화현상 (The Deterioration Phenomena for Dielectrics Causing Corona Discharge)

  • 성영권;백영학;차균현
    • 전기의세계
    • /
    • 제19권6호
    • /
    • pp.18-25
    • /
    • 1970
  • The object of this project is to manifest the mechanism of deterioration phenomena for dielectrics causing corona discharge and applies it for determine the standard corona detection technique. As the results, we observed that corona discharges may occur more strongly around cylindrical shape electrode in air than hemisphere shape electrode in vacuum, so that it depends on effects such as shape of the electrode, moisture, surface coditions, etc. According to observed the deterioration of dielectrics takes place in following stages. At first the attacked surface by an electron avalanche is uniformly eroded; then pits are formed; after that sharp channels are formed which lead to break-down as a treeing. The test are accelerated with higher frequencies by the cylindrical bar shape electrode in the pulse stright detection method more sensitive than Lissajous patterns. Lissajous patterns detection method is simple but usually insensitive and has disadvantage that the magnitude of the individual discharge is not measured.

  • PDF

코로나 방전을 이용한 고에너지 점화 시스템 개발 (Development of a High Energy Ignition System Using Corona Discharge)

  • 박경석;최두원;강혜현;이종화;박진일
    • 한국자동차공학회논문집
    • /
    • 제23권6호
    • /
    • pp.650-655
    • /
    • 2015
  • A high energy ignition system is essential for lean burn or high EGR gasoline engine, which is getting more and more interest to improve fuel economy. The high energy ignition systems comprise plasma jet, laser beam, corona discharge and so on. In this study, a high energy ignition system using corona discharge is developed and tested in a constant volume combustion chamber. The developed system shows extension of lean limit of propane-air mixture and enhencement of combustion speed. Various shape of corona discharge plugs are also tested and compared in this study.

선대 평판형 플라즈마장치의 코로나 방전 및 오존발생 특성에 미치는 바이어스된 3전극의 영향 (Effect of the Biased Third Electrode of a Wire-Plate Type Plasma Reactor on Corona Discharge and Ozone Generation Characteristics)

  • 정재승;문재덕
    • 전기학회논문지
    • /
    • 제57권4호
    • /
    • pp.648-652
    • /
    • 2008
  • Corona discharge and ozone generation characteristics of a wire-plate plasma reactor, with a biased third electrode, have been investigated with an emphasis on the role of the bias voltage and frequency applied on the third electrode. It was found that the wire-plate plasma reactor, with the biased third electrode, had a switching characteristic on its I-V characteristics for negative and positive discharges, which is very different from that of a conventional wire-plate plasma reactor without the third electrode. As a result, the corona discharge and ozone generation characteristics of the proposed plasma reactor could be controlled by adjusting the bias voltage and frequency of the third electrode. The corona onset and breakdown voltages, and ozone generation and yield, were increased compared with those of without the third electrode. These, however, reveal the effectiveness of the biased third electrode.

Editor's Note Response to Friedman's "The World Before Corona and the World After": A Perspective Raging From the Development of Civilization to the Harmony of East and West, and the Paradigm Shift

  • Park, Han Woo;Chung, Sae Won
    • Journal of Contemporary Eastern Asia
    • /
    • 제19권2호
    • /
    • pp.169-178
    • /
    • 2020
  • Thomas L. Friedman's "Our New Historic Divide: B.C. and A.C. ― The World Before Corona and the World After" column is becoming the talk of the times. Whoever talks about the post-Corona world mentions "BC/AC" as a new concept. However, people seem to be overusing the term "BC/AC" while overlooking the specific context that Friedman emphasized. So, taking into account the cultural differences and contexts of the East and the West highlighted in Friedman's column, we devised the "BC/AC" ten-paradigm hypothesis. We hope these ten cultural shifts will be the first step in examining the post-Corona world.

Computation of Refractive Indices of Corona Viruses through Reverse Calculation

  • Kuppuswamy, Srinivasan;Swain, Kaliprasanna;Nayak, Suryakanta;Palai, Gopinath
    • Current Optics and Photonics
    • /
    • 제4권6호
    • /
    • pp.566-570
    • /
    • 2020
  • The present paper computes the refractive indices of different corona viruses (H5N1, H5N2, H9N2, H4N6, FAdV and IBV) through reflectance analysis of a virus solution. The computational analysis indicates that the refractive indices of all viruses are negative at the signal of 412 nm. Further the numerical output shows that the infectious bronchitis viruses (family of novel corona viruses, COVID-19) have higher negative refractive indices as compared to other corona viruses. Finally refractive indices of the family of COVID-19 are investigated with respect to the EID (Electronic infusion Device) concentration of the viruses, showing that the refractive index which ranges from "-0.96725 to -0.999998" corresponds to '0.01 to 10000' EID virus concentration.

Characteristics of a Corona between a Wiring Clamp(Dead End Clamp) and a Porcelain Insulator Used in a 154[kV] Power Receptacle

  • Han, Un-Ki;Kim, Jong-Min;Bang, Sun-Bae;Kim, Han-Sang;Choi, Hyeong-Jun
    • 조명전기설비학회논문지
    • /
    • 제21권9호
    • /
    • pp.57-63
    • /
    • 2007
  • The occurrence of a corona is that electrical discharge due to the heterogeneity that occurs when an electrical field is concentrated in an electrode due to a cusp formed on said electrode. Wire treatment at the end of a 154[kV] dead end clamp for end users accelerates the occurrence of corona, which in turn leads to power loss and noise. In this study, the characteristics of the corona which occurs between porcelain insulators and support clamps of overhead lines used in 154[kV] power receiving facilities for end users were investigated. The corona, which cannot be identified by one common method, was measured utilizing a UV image camera. A risk assessment for fire damage and its status was suggested. The stress distribution of the electrical field by length of bare wire was suggested by means of the finite element method(FEMLAB). As a result, it was found to affect a porcelain insulators. These results can be utilized for the enhancement of clamp installation and safety in power facilities.

코로나 모터를 이용한 송풍장치의 특성 연구 (The Study of Wind Blower Characteristics Using a Blade Type Corona Motor)

  • 정재승;김형표;김진규
    • 조명전기설비학회논문지
    • /
    • 제27권11호
    • /
    • pp.76-81
    • /
    • 2013
  • In this paper, a corona motor with blade type electrodes has been employed as a wind blower. The rotation speed was influenced significantly by the polarity of applied voltage and the number of blades. Therefore the effect of polarity of applied voltage and the number of blades on the electrical and mechanical fundamental properties of corona motor were investigated experimentally. The rotation speed decreased for increasing of number of blades, because the mass of blades increased. But the amount of air blow increased despite decreasing of the rotation speed, because air volume is not only influenced by rotation speed but also the number of blades and ionic wind which generated between blade tips and a induction electrode. Although space occupied by blades of the corona motor is smaller than the whole area of the blast pipe, wind rises a whole range of a wind blower for such reasons.

수중 펄스코로나 방전에 의한 메틸오렌지 제거 특성 (Degradation of methyl orange by pulsed corona discharges in aqueous solution)

  • 이현돈;김종오;김형갑;정재우
    • 상하수도학회지
    • /
    • 제26권1호
    • /
    • pp.69-76
    • /
    • 2012
  • A laboratory experiment on methyl orange degradation in pulsed corona discharges was carried out. Effects of operating parameters such as applied voltage, pH, conductivity and initial concentration on methyl orange degradation were investigated. The pulsed corona discharges decreased the pH of solution and increased conductivity, probably due to products generated from methyl orange degradation by corona discharges. The decrease of initial pH enhanced the methyl orange degradation. The methyl orange degradation was fastest in $100{\mu}S/cm$ conductivity solution, followed by 50 and $200{\mu}S/cm$, indicating that $100{\mu}S/cm$ is the most favorable in the aspect of radical generation among the experimented conditions. The methyl orange of initial concentration from 20 to 60mg/L was effectively degraded in pulsed corona discharges. The lower initial concentration of methyl orange, the faster degradation was observed.

Motor Function Recovery in Stroke Patients with Corona Radiata Infarct: 4 Case Studies

  • Kim, Chung-Sun;Kwon, Jung-Won
    • The Journal of Korean Physical Therapy
    • /
    • 제22권3호
    • /
    • pp.31-35
    • /
    • 2010
  • Purpose: The aim of this study was to use fMRI and clinical prognosis criteria to evaluate therapeutic interventions in stroke patients with corona radiata infarct and acquire fundamental information about recovery mechanisms. Methods: Four subjects (2 men, 2 women) who had strokes with corona radiata infarct were recruited. For all subjects, motor functions such as motricity index (MI), modified brunnstrom classification (MBC), functional ambulatory category (FAC), and bathel index (BI) were evaluated. Evaluations were done at least 4 times over a period of approximately 6~7 months from stroke onset. We compared the final evaluation with the first. Results: All patients with corona radiata infarct showed improvement in motor outcomes with the passing of time. The strength of all patients improved from zero or trace levels to normal or good levels in the MI (Motricity Index) test. Other motor outcomes including the modified brunnstrom classification (MBC), the functional ambulatory category (FAC), and the bathel index (BI) also improved with the passing of time. Conclusion: Stroke patients with corona radiata infarcts change for the better over time. Therefore, one can introduce clinical interventions by the aspect of progress in functional motor recovery.