• Title/Summary/Keyword: Corner column

Search Result 61, Processing Time 0.029 seconds

Evaluation for Progressive Collapse Resistance of a RC Flat Plate System Using the Static and Dynamic Analysis (정적 및 동적 해석을 통한 철근콘크리트 무량판 구조의 연쇄 붕괴 저항 성능 평가)

  • Lee, Seon-Woong;Shin, Sung-Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.2
    • /
    • pp.245-252
    • /
    • 2011
  • Currently, the design guidelines for the prevention of progressive collapse are not available in Korea due to the lack of study efforts in progressive collapse resistance evaluation of RC flat plate system. Therefore, in this study, three types of analysis were conducted to evaluate the progressive collapse resistance of a RC flat plate system. A linear static analysis was carried out by comparing the demand-capacity ratio (DCR) differences of the systems using the alternate load path method, which is the guideline of GSA. A dynamic behavior was investigated by checking the vertical deflection after removal of the column using the linear dynamic analysis. Lastly, a maximum load factor was investigated using the nonlinear static analysis. The finite element (FE) analyses were conducted using various parameters to analyze the results obtained using effective beam width (EB) model and plate element FEM (PF) model. This study results showed that the strength contributions of the slab in the EB models are underestimated compared to those obtained from the PF models. Therefore, a detailed FE analysis considering the slab element is required to thoroughly estimate the progressive collapse resisting capacity of flat plate system. The scenario of the corner column (CC) removal is the most dangerous conditions where as the scenario of the inner column (IC) removal is the least dangerous conditions based on the consideration of various parameters. The analysis results will allow more realistic evaluations of progressive collapse resistance of RC flat plate system.

Water Column Structure and Dispersal Pattern of Suspended Particulate Matter (SPM) in a floating ice-dominated fjord, Marian Cove, Antarctica during Austral Summer (유빙이 점유한 남극 마리안 소만의 하계기간 수층 구조와 부유물질 분산)

  • Yoo, Kyu-Cheul;Yoon, Hoo-Il;Kang, Cheon-Yun;Kim, Boo-Keun;Oh, Jae-Kyung
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.5 no.4
    • /
    • pp.295-304
    • /
    • 2000
  • Vertical measurement of CTDT at about 30 min intervals and spatial surface temperature, salinity, and concentration of suspended particulate matters were conducted to elucidate the character of water column and the dispersal pattern in a floating ice-dominated fjord, Marian Cove, West Antarctica. Marian Cove showed two distinct water layers in terms of turbidity; 1) cold, fresh, and turbid surface plume in the upper 2 m,2) warm, saline, and relatively clean Maxwell Bay inflow between 15-45 m in water depth. Thermal melting of Maxwell Bay inflow and tidewater glacier/floating ices developed the surface mixed layer and the activity of floating ices cause Maxwell Bay inflow to be unstable. Due to the unstable water column, the development of Maxwell Bay inflow and subsequent surface plume are not influenced by tidal frequency. Coastal current generated by strong northwesterly wind may extend warm, saline, and turbid surface plume into the central part of the cove along the northern coast via the western coast of Weaver Peninsula. Terrigenous sediments of meltwaters from the glaciated ice cliffs near the corner of tidewater glacier and some coasts enter into the cove and their dispersion depends upon the hydrographic regimes (tide, wind, wave etc.). At the period of spring tide, the strong wind stress with the northwesterly wind direction reserve suspended sediment-fed surface plume and so allow the possibility of deposition of terrigenous sediments within the basin of cove.

  • PDF

Fire Test of Fiber Cocktail Reinforced High Strength Concrete Columns without Loading (섬유혼입공법을 적용한 고강도콘크리트 기둥의 비재하 내화시험)

  • Youm, Kwang-Soo;Jeon, Hun-Kyu;Kim, Heung-Youl
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.4
    • /
    • pp.465-471
    • /
    • 2009
  • To prevent the explosive spalling of the high strength concrete and control the rise of temperature in the steel rebar during fire, a fiber cocktail method has been proposed simultaneously with the use of polypropylene and steel fiber. After applying the fiber cocktail (polypropylene and steel fibers) into the mixture of high strength concrete with a compressive strength of between 40 and 100 MPa and evaluating the thermal properties at elevated temperatures, the fire test was carried out on structural members in order to evaluate the fire resistance performance. Two column specimens were exposed to the fire without loading for 180 minutes based on the standard curve of ISO-834. No explosive spalling has been observed and the original color of specimen surface was changed to light pinkish grey. The inner temperature of concrete dropped rapidly starting from 60mm deep. After 60 minutes of exposure to the fire, the temperature gradient of fiber cocktail reinforced high strength concrete was measured as 2.2oC/mm, which is approximately 5 times less than that of normal concrete. The final temperatures of steel rebar after 180 minutes of fire test resulted in 488.0oC for corner rebar, 350.9oC for center rebar, and 419.5oC for total mean of steel rebar. The difference of mean temperature between corner and center rebar was 137.1oC The tendency of temperature rise in concrete and steel rebar changed between 100oC and 150oC The cause of decrease in temperature rise was due to the water vaporization in concrete, the lower temperature gradient of the concrete with steel and polypropylene fiber cocktails, the moisture movement toward steel rebars and the moisture clogging.

The effect of a static magnetic field of Nd-Fe-B magnet on alkaline phosphatase activity of MC3T3-E1 cells (Nd-Fe-B 자석의 정자기장이 MC3T3-E1 세포의 alkaline phosphatase 활성도에 미치는 영향)

  • Kim, Sook-Hee;Kwon, Oh-Won;Ryoo, Hyun-Mo
    • The korean journal of orthodontics
    • /
    • v.30 no.2 s.79
    • /
    • pp.205-214
    • /
    • 2000
  • Recently, the magnetic force has been considered as a method for a more efficient tooth movement. The purpose of this study was to evaluate the effects of different static magnetic fields of Nd-Fe-B magnet on MC3T3-E1 cells by measuring the alkaline phosphatase activity and observing the amount of stained alkaline phosphatase. For measuring of alkaline phosphatase activity, MC3T3-E1 cells were seeded in first and third row of 12 well culture plates. And Nd-Fe-B magnets were positioned under the first column of first and third row to apply different static magnetic fields(first column:100mT ; second column:4.6mT ; third column:0.5mT ; forth column:0.0mT) to the cells for 7, 13, 19, and 25 days. For staining of alkaline phosphatase, MC3T3-E1 cells were seeded in 100mm culture plates. And Nd-Fe-B magnets were positioned under the corner of plates to apply different static magnetic fields(magnet side:100mT : the opposite side:0.5mT) to the cells for 7, 13, 19, and 25 days. The results were as follows : 1. ALP activity was increased until day 19 in biochemical determination as well as in histochemical staining, 2. The application of higher magnetic field(100mT) suppressed ALP activity at day 13, 19, 25. On the contrary, the application of the lower magnetic field(4.6mT, 0.5mT) significantly enhanced the ALP activity. 3. Consistent with enzyme assay, histochemical staining of ALP also demonstrated that higher magnetic field(100mT) suppressed ALP activity, lower one(0.5mT) enhanced.

  • PDF

A Review on Changes in Spatial Formation of the Sangrojun Area in Tongdo Temple (통도사 상로전 영역의 공간구성 변화 고찰)

  • Hong, Jae-Dong
    • Journal of architectural history
    • /
    • v.10 no.3 s.27
    • /
    • pp.45-60
    • /
    • 2001
  • The Tongdo temple have been transformed continuously since its first establishment about 1300 years ago. Nevertheless three critical elements specified by 'Jajangyulsa', founder of the temple have not varied over the times but rather strengthened and strongly combined. All elements and doctrines of the religion coexist and form a harmony within the whole of the temple. This researcher examined what changes, or combinations, in spatial formation were sought for such unique structures of the Tongue temple by focusing mainly on the Sangrojun area of the temple to obtain the following findings. First. unlike a work by a Japanese researcher 'Sekino Tadashi', the east yard of the main building was found located on the section line which corresponded to the separation line of Yungkuncheokdo(營建尺度=measure running) from the edge of the Keumkangkyedan(金剛戒壇 =Buddhist platform) embankment to the corner column of the Kamrodang. This was confirmed as a result of the review of photos shown in [Chosun Kojukdobo]. Second, the number of stairs used for the Keumkangkyedan was thought to become three when the temple was firstly restored in 1379 as a result that this researcher reviewed Chinese literature 'DoSun' and [Kyedandokyung(戒壇圖經)], records by 'Lee saek' and 'Jung Shihan', studies of Yungkun measure and actual changes in the temple. Then the temple was forth restored in 1705 when the second of the stairs was changed in area and height and at the same time grounded hard for a space for a Buddhist service. Third, the roof of the main building was probably changed in shape during the Koryo period when the plane structure, furnish arrangement, emphasized front, stone lanterns of the building and political factors of that time were all considered. Fourth, the main building was Initially designed to provide a Buddhist sermon service which was assumedly followed by a similar service at a Keumkangkyedan. Thus the main building had a small window on the northern side which might be opened up to look out or otherwise go outside like a door. However, the window was probably locked up like a surrounding wall since the main building was entirely repaired after the end of Japanese invasion of Korea in 1592.

  • PDF

The Site Plan and the Design of Daeungjeon(Main Buddhist Hall) of Songgwangsa Temple Seen by Yi Ok, in the Late Joseon Period (이옥이 본 조선 후기 완주 송광사의 가람배치와 대웅전의 구조)

  • Tahk, Kyung-Baek
    • Journal of architectural history
    • /
    • v.26 no.2
    • /
    • pp.43-52
    • /
    • 2017
  • While going into troops for writing in the vignette style(小品文) in opposition to the Classical Chinese(古文), Yi Ok stopped by Songgwangsa Temple in Wanju. The things he felt during this stop were recorded in the Temple Chapter("寺觀") written in 1795. Therefore, the present dissertation evaluates the Songgwangsa Temple of the time based on this Temple Chapter. Data in the Temple Chapter draws attention to the fact that it records the layout of the temple in detail. Thus the study was able to confirm the change in layout by reviewing relevant records about repair. This reveals that the form of layout in general has been maintained although there were changes involving the relocation of the buildings and their names. Furthermore, the original Buddhist building was changed to a quarter for the monks. Also, in terms of layout after the 18th century, there are frequent name changes of the Myeongbujeon(冥府殿) and Nahanjeon(羅漢殿). After two repairs, in order to find the appearance of a Daeungjeon(Main Buddhist hall) with a two-storied structure of five bays at the front, the study evaluated the Geugnakjeon at Muryangsa Temple and the Daeungbojeon at Magoksa Temple. The evaluation revealed that the 'Jeol' used in the Temple Chapter were small pillars erected on a ridgepole just like the Geugnakjeon at Muryangsa Temple, and that the angle rafters were installed to corner bays in rectangular form. The intellectual Yi Ok left behind invaluable architectural data that reveals the Songgwangsa Temple of the 18th century.

Study of apartment plan technology adopting structural element of Hanok (공동주택에 적용 가능한 한옥 평면기술에 관한 연구)

  • Park, Kyung Hyun;Roh, Young-Sook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.10
    • /
    • pp.6366-6371
    • /
    • 2014
  • This study examined the structural elements of Korean-style houses (Hanok) and proposed formula accounting for their similar patterns and regular behavior. The design of modern apartment buildings adopts many aesthetic elements from Hanok but those are only for interior decoration. In this study, the projected Hanok eaves were examined in terms of the length of solar insolation. Leaning pillars toward the inside of the building were analyzed in detail not only for the front and back pillar, side pillar, but also the corner pillar. This study also suggested a design element from the Hanok structure, such as the elevated balcony, porch flooring, and inner garden in porch area. In addition, the new apartment plan improved air circulation, ventilation and natural lighting.

Case Study on the Explosive Demolition of the KOGAS Office Building in Bundang District (한국가스공사 분당사옥 발파해체 시공사례)

  • Kim, Sang-min;Park, Keun-sun;Son, Byung-min;Kim, Ho-jun;Kim, Hee-do;Kim, Gab-soo
    • Explosives and Blasting
    • /
    • v.36 no.4
    • /
    • pp.48-61
    • /
    • 2018
  • This case study is concerned with the project of the explosive demolition for the KOGAS office building located in Bundang district in Seongnam city. Since the office building was a kind of long-span beam structures, a mechanical demolition method using jacking support systems was considered in the beginning of the project. With consideration of the excessive reinforcement cost, uncertainty of safety, and prolonged construction period, however, the original plan was later changed to use an explosive demolition method. For the purpose of protecting nearby buildings and facilities during the collapse process, the explosive initiation sequence was elaborately designed to bring down the building structure towards its front left corner. A total of over 550 electronic detonators (Unitronic 600) was used to sequentially initiate the explosives installed at appropriate columns in the first, second, and fifth floors. To diminish dust production, water bags of small and large sizes were respectively installed at each column and on the floors to be blasted. As such, every effort was exercised to mitigate overall noise, dust, and shock vibrations that could be generated during the explosive demolition process for the office building.

Properties of Components for the Dapogye of Hipped and Gable Roof Wooden Buildings (합각지붕 사찰 주불전의 규모에 따른 기둥 및 처마부 관계분석 연구)

  • Go, Jung-Ju;Lee, Jeong-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.3192-3202
    • /
    • 2014
  • This study has its purposes on analyzing specific features of the elements according to scales of 32 main buddhist sancta among wooden temples with gable roof that are nationally designated as cultural assets, and analyzing influences and proportional relations between main and submaterials, so that it could be basic and objective data for restore and repair cultural assets in the future. Results of the study are following. First of all, the average plane proportion of doritong (facade) and yangtong (side) in 3-room building is about 1.31:1, while it is 1.70:1 in 5-room building. Secondly, as a result of analyzing the locational proportion and thickness of pillars at each location, floor room turned out to have wider space between pillars than that of edge room or side room in both cases of 3 and 5-room buildings. In the mean time, for the average thickness of the pillars in 3-room building, it was 491mm for corner pillars, 433mm for general pillars in cases of 3-room building, while it was 595 and 511mm respectively in cases of 5-room building. The reason why corner pillars are 60~80mm thicker than general ones in average, is determined to considered structural stability and optical illusion. For the third, as a result of analyzing the influences on pillar thickness, eaves projection and eaves height according to the scale(dimension) of buildings, 3-room buildings have outstanding correlation as its scale(dimension) goes bigger, while 5-room ones are not very much influenced by its scale(dimension). For the fourth, as a result of the relation between pillars and eaves, both of 3 and 5-room buildings have longer-projected and higher eaves as their pillars go taller; especially height of eaves turns out to have very close relation between length of pillars. In addition to that, both of 3 and 5-room buildings have much projected eaves as the eaves go higher.

Shear Behavior of Precast Prestressed Inverted-Tee Concrete Beams with Dapped Ends (프리캐스트 프리스트레스트 콘크리트 역티형보의 댑단부 전단거동)

  • 유승룡
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.1
    • /
    • pp.46-53
    • /
    • 2001
  • Two full scale precast pretensioned dapped ended rectangular beams designed by PCI design handbook for a major domestic live load of market and parking building - 500kgf/㎡ and 1,200kgf/㎡ were investigated experimentally. The bottom length of beams was 60cm which was same to the length of rectangular column in the base of five-story market or parking buildings. The height of dap was web hight plus half of the flange height within the allowable limit of PCI method. Shear tests were performed on four beam ends. Followings were obtained from the experimental study. All of the specimens were fully complied with the PCI design handbook. Two of four specimens which were designed for live load of 1,200kgf/㎡ showed crackings at the re-entrant corner of dap before the full service loadings, and failed by direct shear at the load level much less than their calculated nominal strength. The specimens designed for live load of 1,200kgf/㎡ failed at 772 tonf and 78.36tonf by direct shear crackings. This strength was less than PCI limit of 81.9 tonf and higher than ACI limit of 65.62tonf. Thus, the limit suggested by ACI seems more reasonable in regard of safety in view of this test results. According to load-strain curves, the strain of hanger reinforcement reached almost yield strain. It is recommended to use more inclined hanger reinforcement of improve the strength and serviceability.