• Title/Summary/Keyword: Core compressor

Search Result 43, Processing Time 0.031 seconds

Sensitivity Analysis on Off-Design Performance of Centrifugal Compressor Due to the Parameters of Two-zone Model and TEIS Model (두영역 모델과 직렬두요소 모델의 변수에 의한 원심 압축기 탈설계 성능의 민감도 분석)

  • Yoon, Sung-Ho;Baek, Je-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.6
    • /
    • pp.834-844
    • /
    • 2000
  • In this study, an off-design performance analysis procedure is developed based on Two-zone model and TEIS model. In Two-zone model, there are both primary zone and secondary zone for an isentropic core flow and an average of all non-isentropic streamtubes respectively. The level of the core flow diffusion in an impeller is calculated by using TEIS model which regards the impeller as two successive rotating elements in series. At impeller exit, the mixing process occurs with an increase in entropy, that is to say, a decrease in total pressure. In loss models including Two-zone and TEIS model, some empirical parameters have a great influence on overall performance curve. So these parameters' influences on the overall performance curve are investigated and compared with experimental data.

Analysis of Flow Phenomena in a Centrifugal Compressor Impeller Operating near Stall (스톨 근처에서 원심압축기 임펠러의 내부 유동현상에 관한 연구)

  • Eum, Hark-Jin;Kang, Shin-Hyoung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.3
    • /
    • pp.330-337
    • /
    • 2004
  • Analysis of flow phenomena in a centrifugal compressor impeller has been carried out with numerical simulation to understand the physics of flow near stall. Near stall point, tip leakage flow spills ahead of the leading edge of adjacent blade and other leakage flow passes over the clearance of the adjacent blade instead of rolling up into vortex within the passage. The tip leakage flow at the mid chord of impeller blade impinges against the pressure surface of the adjacent blade and then rolls up into vortex within the passage, which blocks the flow passage and generates viscous loss. The spillage of leakage flow ahead of the adjacent blade generates the recirculation of flow entering the impeller, which causes the power transferred into the flow by the impeller to decrease and blocks the flow passage. Near diffuser hub wall, flow recirculation occurs. As operating point goes to stall point, the core of recirculation approaches the impeller exit The length rises to peak point and then drops with mass flow reduction, while the height steadily rises.

Development of Control System with Android Operation System for Dentistry Integrated Device (치과용 통합공급장치를 위한 안드로이드 운영체제가 내장된 제어시스템 개발)

  • Hwang, Gi-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.3
    • /
    • pp.635-642
    • /
    • 2012
  • In this paper, a real-time control system with Wi-Fi wireless communication was developed for dentistry Integrated Device. The control system is developed based on the Android platform using S3C6410 ARM core that is equipped with Wi-Fi communication, RS-485, Linux 2.6 and Android 2.0. The control system controls a water purifier, compressor and suction in real-time. The experimental results that the control system was controlled by each control modules connected with a water purifier, compressor and suction. The status values are displayed in real-time using RS485.

Development of Somaloy Components for a BLDC Motor in a Scroll Compressor Application

  • Persson, Mats;Nord, Goran;Pennander, Lars-Olov;Atkinson, Glynn;Jack, Alan
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.804-805
    • /
    • 2006
  • Electric scroll-compressor drives are commonly used for e.g. home appliance cooling units. The recent development of hybrid cars with internal combustion engine in combination with electrical propulsion requires new solutions to be able to cool the passenger compartment of cars at stand-still. Both application areas demand efficient motor drives to reach good economy and efficient use of limited battery power as well as competitive volume/weight for a given output. The BLDC motor is a controllable and efficient solution. A major part of the motor is the soft-magnetic core. The powder based $Somaloy^{(R)}$ material shows high resistivity and induction as the result of engineered iron particles with in-organic coating. The unique features of compacted $Somaloy^{(R)}$ components can be utilized to enhance the shape and total volume of the BLDC motor with at least maintained efficiency compared to the use of traditional laminated steel sheet cores. A careful design of the $Somaloy^{(R)}$ components can also simplify assembly and positively influence the coil configuration. This study shows a comparison between a typical laminated BLDC motor and a redesigned, $Somaloy^{(R)}$ based version adapted for a scroll-compressor application.

  • PDF

Development of a Performance Prediction Method for Centrifugal Compressor Channel Diffusers

  • Kang, Jeong-Seek;Cho, Sung-Kook;Kang, Shin-Hyoung
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.8
    • /
    • pp.1144-1153
    • /
    • 2002
  • A hybrid performance prediction method is proposed in the present study. A channel diffuser is divided into four subregions: vaneless space, semi-vaneless space, channel, and channel exit region. One-dimensional compressible core flow and boundary layer calculation of each region with an incidence loss model and empirical correlation of residuary pressure recovery coefficient of a channel predict the performance of diffusers. Three channel diffusers are designed and tested for validating the developed prediction method. The pressure distributions from an impeller exit to the channel diffuser exit are measured and discussed for various operating conditions from choke to nearly surge conditions. The strong non-uniform pressure distribution which is caused by impeller-diffuser interaction is obtained over the vaneless and semi-vaneless spaces. The predicted performance shows good agreement with the measured performance of diffusers at a design condition as well as at off-design conditions.

The Analysis of Welding Deformation in Arc-spot Welded Structure (II) - Displacement Monitoring and Deformation Analysis - (아크 점용접 구조물의 정밀 용접 열변형 해석에 관한 연구 (II) - 변위 모니터링 및 변형 모델 정립 -)

  • 장경복;조상명
    • Journal of Welding and Joining
    • /
    • v.21 no.4
    • /
    • pp.80-86
    • /
    • 2003
  • Arc-spot welding is generally used in joining of precise parts such as case and core in electric compressor. It is important to control joining deformation in electric compressor because clearance control of micrometer order is needed for excellent airtightness and anti-nose. The countermeasures for this deformation in field have mainly been dependent on rule of try and error by operator's experience because of productivities. For control this deformation problem without influence on productivities, development of exact simulation model should be needed. In this study, on the basis of previous study, the analysis model io predict deformation of precise order in arc-spot welded structure with non-uniform stiffness is brought up through feedback and tuning between monitoring data and analysis results. For this, deformation monitoring system was built and boundary condition considering mechanical melting temperature was applied.

A Simplified Method to Calculate the EMF Characteristics of Multi-disk Axial-gap PM Motor using 2-D & 3-D FEM

  • Kim, Young-Kwan;Lee, Ju
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.3
    • /
    • pp.34-39
    • /
    • 2008
  • The purpose of this paper is characteristic analysis of multi-disk axial-gap pm motor for turbo compressor. The axial-gap permanent magnet motor has shown a growing interest in high-speed application for its high-efficiency, compact size and low vibration characteristics due to core-less structure. To achieve high-power, the axial-gap PM motor has multi-disk structure of stator and rotor disk. Because of its complicated magnetic flux path, it is not easy to calculate a dynamic characteristics using finite element analysis. In this paper, the simplified 2-D unfolded model to predict EMF characteristic is presented. To verify thesuggested 2-D unfolded model analysis of back-EMF characteristic was calculated and compared 3-D finite element. Finally the proposed method is verified by experimental results and shows good agreement with test results.

A Study on the MED-TVC Operating Performance Characteristics of using the Thermo-Compressor (열압축기를 채용한 다중효용 담수설비의 운전특성에 관한 연구(1보))

  • Choi, Du-Youl;Jin, Chang-Fu;Song, Young-Ho;Choi, Soon-Ho;Chung, Han-Shik;Kim, Pil-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.8
    • /
    • pp.1185-1191
    • /
    • 2008
  • The core design technology for the multi-effect desalination plant using the thermo compressor (MED-TVC) was investigated by the performance test of multi effect desalination plant in this paper. The final G.O.R (gain of output ratio) of MED-TVC type desalination plant is strongly affected by the performance of thermo-vapor compressor. The present experiments for the desalinating capacity and G.O.R were obtained for the range of the motive steam pressure, 266.0, 250.0, 230.0 and 200.0 kPa. And as a practical problem, to investigate the influence of the sea water temperature to the G.O.R, the inlet steam temperature of the suction water vapor was changed in the range of $311.2{\sim}324.2$ K in the present experiment. Through the experiments, the maximum value of G.O.R was 8.5 at the condition of the motive steam pressure, 136.0 kPa and the minimum value of G.O.R was 8.1 at the condition of the motive steam pressure, 266.0 kPa. And it was confirmed that the range of desalination capacity was $355.2{\sim}264.0$ ton/day in the normal operation condition.

Development of Test Facility for Micro Gas Turbine (마이크로 가스터빈 시험 장치 개발)

  • Lim, Hyung-Soo;Choi, Bum-Seog;Park, Moo-Ryong;Hwang, Soon-Chan;Park, Jun-Young;Seo, Jeongmin;Bang, Je-Sung;Lim, Young-Chul;Oh, In-Kyun;Kim, Byung Ok;Cho, Ju Hyeong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.5
    • /
    • pp.42-48
    • /
    • 2015
  • To improve the core technology of the micro gas turbine, the performance test facility was developed. This paper is focusing on the explanation of the characteristics of micro gas turbine and its assist devices. Major part of micro gas turbine were radial type of compressor, annular type of combustor, radial type of turbine, thrust foil bearing, radial foil bearing and generator. The assist devices were consist of exhaust duct, inverter, data acquisition system, load bank and test cell. Before building up the test facility, the component test was previously conducted to confirm the component performance. After the test facility was prepared, the motoring test was conducted to investigate the rotor dynamic characteristics of the micro gas turbine. Also, the part load performance test was performed. With a developed micro gas turbine test facility, the improved core technology about the micro gas turbine can be suggested to the related industries.

Analysis on Harmonic Loss of IPMSM for the Variable DC-link Voltage through the FEM-Control Coupled Analysis

  • Park, Hyun Soo;Jeung, Tae Chul;Lee, Jae Kwang;Lee, Byoung Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.225-229
    • /
    • 2017
  • This paper describes the loss analysis based on load conditions of the air conditioning compressor motors using variable dc-link voltage. The losses of PMSM (Permanent Magnet Synchronous Motor) should be analyzed by the PWM (Pulse Width Modulation) output of inverter. The harmonic loss by the PWM cannot consider that using the current source analysis of the inverter. In addition, when the voltage of dc-link is variable with the condition of variable speed and load conditions in motor, the losses of motor are also changeable, however it is hard to analyze those losses by only electromagnetic finite element method (FEM). Therefore, this paper proposes the analysis method considering the carrier frequency of the inverter and the varying state of the dc-link voltage through the FEM-control coupled analysis. Using proposed analysis method, additional core loss and eddy current loss of permanent magnet caused by PWM could be analyzed. Finally, the validity of the proposed analysis method is verified through the comparison the result of coupled analysis with experiment.