• Title/Summary/Keyword: Core Generator

Search Result 213, Processing Time 0.039 seconds

Performance Evaluation in Fin-Tube Heat Exchanger by Tow-In Winglet Pairs (Tow in 와류발생기에 의한 핀-관 열교환기의 성능실험)

  • ;Kahoru Torii
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.2
    • /
    • pp.87-94
    • /
    • 2003
  • To reduce the air side pressure drop in air-cooled heat exchanger, tow-in type winglet vortex generators are applied. A specially designed multiple-channel test core was used in the experiments for the various geometry of winglet vortex generators. The proposed tow-in type vortex generator gives significant separation delay, reduces form drag, and removes the zone of poor heat transfer from near-wake of the tubes. The results show the significant pressure drop reduction for the tow-in win91e1 vortex generators with the similar enhancement of the heat transfer as other vortex generator applications in heat exchanger. In the range of Reynolds number of 350 to 2100 the pressure drop decrease 8∼15% and 34∼55% for the in-line and staggered tube banks, respectively, compared to those without vortex generators.

Heat Transfer Analysis of Ice Slurry Generator (아이스슬러리 제빙장치의 열전달 해석)

  • Shin, You-Hwan;Lee, Yoon-Pyo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.984-989
    • /
    • 2009
  • The present study has been conducted to predict the temperature distribution in the core of the scraper type ice generator. The analytic model was simplified as the flow in the annular type cylinder, which had an inside wall moving in axial direction due to the rotation of screw and a fixed outside wall. The governing equations were arranged by the method of separation of variables. The results corresponded to the exact solutions of the Bessel function. The qualitative results such as general characteristics of heat transfer in annulus flow from outer cylinder wall to the inside wall were obtained. However the amount of the heat transfer was underestimated as low as $1/5{\sim}1/6$ of the designed value.

  • PDF

A Study on Start·Stop System at Water Turbine-Generator for Tidal Power Plant (조력발전용 수차발전기의 기동·정지시스템에 관한 연구)

  • Oh, Min-Hwan;Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.2
    • /
    • pp.113-118
    • /
    • 2014
  • Tidal power is one of new and renewable energy sources. Tidal power is generated by using the gap in the water level between the water outside and inside the embankment. All tidal power plant in Korea were being operated by import of turn-key from abroad. The know-how and technology which are the most important to build predictive control system has become increasingly difficult to obtain from advanced countries because most of them avoid to transfer, which the domestic development of the control system is needed. In this paper, a study on start stop system at water turbine-generator for tidal power plant at the beginning of development was presented. For improvement the efficiency and develope of core technology of the start stop system, the technique and characteristics of tidal power, modeling, maximum generation calculation method, and optimal control of joint control system in Sihwa tidal power plant were studied.

High Efficiency Operation of a Switched Reluctance Generator over a Wide Speed Range

  • Yu, Siyang;Zhang, Fengge;Lee, Dong-Hee;Ahn, Jin-Woo
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.123-130
    • /
    • 2015
  • This paper investigates the high efficiency operation of a switched reluctance generator over a wide speed range. The system efficiency is improved by optimizing the current shape. A modified angle position control (MAPC) method that can be used to optimize the current shape over a wide speed range is proposed. Simulation and experimental results are presented to validate the effectiveness of the proposed control scheme.

A study on the Analysis of Insulation Aging for Generator stator windings (수력발전기 고정자권선의 절연열화 분석)

  • Byun, D.G.;Oh, B.K.;Kang, D.S.;Lim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2072-2074
    • /
    • 2005
  • This test was performed to assess the insulation condition of the stator winding of 3.45kV hydro generator in insulation deterioration condition which was due to long service period(30years) since installed We extracted 12 stator wingdings from the hydro generator core, cut the stator windings into three parts(Middle winding part, slot winding part, end wingding part), and evaluated the insulation condition to know the deterioration condition of each parts. This insulation diagnostic tests include AC current, dissipation factor, and partial discharg test.

  • PDF

Solid Core Suspension Disc Insulators Preventing Puncture Caused by Steep Front Surge Voltage

  • Sangkasaad, Samruay
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.5
    • /
    • pp.165-170
    • /
    • 2003
  • This paper presents development of solid core suspension disc insulators (cap and cap suspension disc insulator) for replacing cap and pin suspension disc insulators in overhead transmission and distribution lines which expose to lightning discharges. By this means the punctured problem caused by steep front surge voltage created by lightning discharge on the lines can be solved. The solid core suspension insulator was designed and constructed based on the dimensions of conventional suspension disc insulators (cap and pin insulators). The insulators are made of alumina porcelain. The electrical and mechanical characteristics of the solid core suspension insulators were carried out. The puncture test was performed in the air by applying steep front impulse voltage with amplitude about 2.5 per unit of 50% flashover (CFO) of the insulator unit at negative standard lightning impulse $1.2/50\;\mu\textrm{s}$ with steepness up to $9200\;kV/\mu\textrm{s}$. The testing results show that solid core suspension disc insulators are not punctured eventhough the steepness of the steep front impulse voltage was increased up to $9200\;kV/\mu\textrm{s}$.

Development of Start·Stop Control System at Water Turbine Generator for Tidal Power Plant (조력발전소를 위한 수차발전기의 기동·정지 제어시스템 개발)

  • Cho, Byong-Og;Park, Chul-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.6
    • /
    • pp.106-112
    • /
    • 2014
  • Recently, tidal power generation has gained much attention. South Korea's tidal power generation systems were imported from abroad by turnkey type and have being operated. Therefore, for efficient operation and technological independence of a tidal power system, development of core technology is required. This paper deals with the start stop control system of water turbine generator in the tidal power plant, as one of our development project results. Using the SCADA system, the status and operations of water turbine generator in the tidal power plant, as well as simulation for calculation of maximum power were carried out. A small model type of start stop control device was also developed. In addition, the control system in Sihwa tidal power plant was modeled, and the results obtained by the dynamic simulation were given in graphics by 2D simulator.

Implementation of a PC based Hardware Simulator with 128 channels (128채널 PC 기반 하드웨어 시뮬레이터 구현)

  • 정갑천;최종현;박성모
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.40 no.5
    • /
    • pp.298-305
    • /
    • 2003
  • This paper describes a 128-channel hardware simulator that is useful for verification and testing of digital circuits. It performs logic analyzer function and signal generator function at the same time. The core module, which implements one channel of the simulator, operates as a controller with independent memory and internal mode. Therefore, we can easily extend the number of channels with addition of core module. Moreover, since the simulator was implemented as a PC based system, one can construct a low-cost system and can configure convenient GUI(Graphic User Interface) environment. The simulator implemented using FPGA operates at 50Mhz and consumes 55W power as average.