• 제목/요약/키워드: Cord angle

검색결과 64건 처리시간 0.024초

유한요소법을 이용한 코오드-고무 복합판의 동적특성에 관한 연구 (A study on the dynamic characteristics of the cord-rubber laminates rectangular plate by finite element method)

  • 김두만;김항욱
    • 오토저널
    • /
    • 제8권2호
    • /
    • pp.51-64
    • /
    • 1986
  • There has been considerable interest over the last twenty years in the subject of the elastic properties of the cord-rubber laminate. This has been due to the rather intensive study of the composites materials characteristics brought about by the increased use of rigid composites materials characteristics brought about by the increased use of rigid composites in many structural applications. The object of this study is to obtain the natural frequencies and modes of the simply supported cord-rubber laminate plates prior to the study on the analysis of the dynamic properties of the pneumatic tire. To obtain these natural frequencies and modes, the 12 degrees of freedom orthotropic rectangular plate finite elements are developed. By using classical lamination theory, the stress-strain relations are represented. The governing equation for the finite element is derived by energy method. To find the natural frequencies and modes, he eigenvalues and corresponding eigenvectors are computed by the well known Jacobi power method. In order to verify the capability of this present finite element, the results of the specially orthotropic plate and the angle-ply laminate plate are compared with the analytical solution. The analytical and numberical results are in good agreement. The following problems of the simply supported plate are analyzed by the present finite element. a) the natural frequencies and mode shapes of the cord-rubber laminate plate for various aspect ratio. b) The natural frequencies and mode shapes of the orthotropic plate with the rectangular hole in its center.

  • PDF

Load Sharing Mechanism Across Graft-Bone Interface in Static Cervical Locking Plate Fixation

  • Han, In-Ho;Kuh, Sung-Uk;Chin, Dong-Kyu;Jin, Byung-Ho;Cho, Yang-Eun;Kim, Keun-Su
    • Journal of Korean Neurosurgical Society
    • /
    • 제45권4호
    • /
    • pp.213-218
    • /
    • 2009
  • Objective : This study is a retrospective clinical study over more than 4 years of follow up to understand the mechanism of load sharing across the graft-bone interface in the static locking plate (SLP) fixation compared with non-locking plate (NLP). Methods : Orion locking plates and Top non-locking plates were used for SLP fixation in 29 patients and NLP fixation in 24 patients, respectively. Successful interbody fusion was estimated by dynamic X-ray films. The checking parameters were as follows : screw angle (SA) between upper and lower screw, anterior and posterior height of fusion segment between upper and lower endplate (AH & PH), and upper and lower distance from vertebral endplate to the end of plate (UD & LD). Each follow-up value of AH and PH were compared to initial values. Contributions of upper and lower collapse to whole segment collapse were estimated. Results : Successful intervertebral bone fusion rate was 100% in the SLP group and 92% in the NLP group. The follow-up mean value of SA in SLP group was not significantly changed compared with initial value, but follow-up mean value of SA in NLP group decreased more than those in SLP group (p=0.0067). Statistical analysis did not show a significant difference in the change in AH and PH between SLP and NLP groups (p>0.05). Follow-up AH of NLP group showed more collapse than PH of same group (p=0.04). The upper portion of the vertebral body collapsed more than the lower portion in the SLP fixation (p=0.00058). Conclusion : The fused segments with SLP had successful bone fusion without change in initial screw angle, which was not observed in NLP fixation. It suggests that there was enough load sharing across bone-graft interface in SLP fixation.

Single Stage Circumferential Cervical Surgery (Selective Anterior Cervical Corpectomy with Fusion and Laminoplasty) for Multilevel Ossification of the Posterior Longitudinal Ligament with Spinal Cord Ischemia on MRI

  • Son, Seong;Lee, Sang-Gu;Yoo, Chan-Jong;Park, Chan-Woo;Kim, Woo-Kyung
    • Journal of Korean Neurosurgical Society
    • /
    • 제48권4호
    • /
    • pp.335-341
    • /
    • 2010
  • Objective : Anterior cervical corpectomy with fusion (ACF) or laminoplasty may be associated with substantial number of complications for treating multilevel cervical ossification of the posterior longitudinal ligament (OPLL) with significant cord compression. For more safe decompression and stabilization in multilevel cervical OPLL with prominent cord compression, we propose circumferential cervical surgery (selective ACF and laminoplasty) based on our favorable experience. Methods : Twelve patients with cervical myelopathy underwent circumferential cervical surgery and all patients showed multilevel OPLL with Signal change of the spinal cord on magnetic resonance imaging (MRI). A retrospective review of clinical, radiological. and surgical data was conducted. Results : There were 9 men and 3 women with mean age of 56.7 years and a mean follow up period of 15.6 months. The average corpectomy level was 1.16 and laminoplasty level was 4.58. The average Japanese Orthopedic Association score for recovery was 5.1 points and good clinical results were obtained in 11 patients (92%) (p < 0.05). The average space available for the cord improved from 58.2% to 87.9% and the average Cobb's angle changed from 7.63 to 12.27 at 6 months after operation without failure of fusion (p < 0.05). Average operation time was 8.36 hours, with an estimated blood loss of 760 mL and duration of bed rest of 2.0 days. There were no incidences of significant surgical complications, including wound infection. Conclusion : Although the current study examined a small sample with relatively short-term follow-up periods, our study results demonstrate that circumferential cervical surgery is considered favorable for safety and effectiveness in multilevel OPLL with prominent cord compression.

Short Segment Anterior Correction of Adolescent Idiopathic Scoliosis

  • Han, In-Ho;Chin, Dong-Kyu;Kim, Keun-Su
    • Journal of Korean Neurosurgical Society
    • /
    • 제44권1호
    • /
    • pp.52-56
    • /
    • 2008
  • Objective : The purpose of this study was to introduce our surgical experiences of scoliosis and to evaluate the effectiveness of anterior correction and fusion in adolescent idiopathic scoliosis (AIS). Methods : Between August 2004 and August 2007, four patients with AIS were treated with anterior segmental fusion and fixation at our hospital. Mean follow-up period was 9 (6-12) months. The average age was 14.0 (13-15) years. According to Lenke classification, three patients showed Lenke 1 curve and one patient with Lenke 5 curve. Single rod instrumentation was performed in one patient, dual rod instrumentation in one patient and combined rod instrumentation in two patients. Coronal Cobb measurements were performed on all curves in thoracic, thoracolumbar and, lumbar spine and the angle of hump was measured by a scoliometer pre- and postoperatively. Results : The average operative time was 394 minutes (255-525) with an average intraoperative blood loss of 1,225 ml (1,000-1,700). The mean period of hospital stay was 19.3 days and there was no complication related to the surgery. The mean Cobb angle was reduced from $43.3^{\circ}$ to $14.8^{\circ}$ (65.8% correction) postoperatively and the rib hump corrected less than $5^{\circ}$. All patients and their parents were satisfied with the deformity correction. Conclusion : Anterior spinal correction and fusion of AIS with Lenke 1 and 5 curve showed excellent deformity correction without any complications. In particular, we recommend anterior dual rod instrumentation because of mechanical stability, better control of kyphosis, and a higher fusion rate.

다익 홴/스크롤 시스템의 형상변수와 내부 유동장 특성과의 관계 (Some Relations Between the Geometric Parameters and Internal Flow Field Characteristics in Multiblade Fan/Scroll System)

  • 맹주성;유달현;이광호;박인규
    • 대한기계학회논문집B
    • /
    • 제24권9호
    • /
    • pp.1139-1147
    • /
    • 2000
  • This paper describes that the size of inactive zone can be directly applied to design multiblade fan/scroll system. From the experimental studies using a five hole pitot tube and smoke test, it is found that the size of inactive zone has linear relations with the mean velocity of impeller inlet and cut-off angle gives a great influences to the fan efficiency. For the practical design, a function related with geometric parameters(i.e. inner radius, cord length, cut-off clearance and cut-off angle) of fan/scroll system is suggested. By using these formulas, the size and distribution of inactive zone can be predicted without the measurements through the full domain, it can be possible to use them to know the efficiency improvement for new model designed.

경부 전산화단층촬영상에서 후두계측 (Laryngeal Measurement on Neck CT)

  • 유영채;오재식
    • 대한기관식도과학회지
    • /
    • 제2권1호
    • /
    • pp.71-81
    • /
    • 1996
  • 1992년 1월부터 1994년 12월까지 전남대학병원에서 경부 전산화단층촬영을 시행한 환자 중 경부에 종양, 염증성 질환 등 기질적인 질환 및 경부외상의 기왕력이 없는 45례의 경부 전산화단층촬영상에서 캘리퍼스 및 분도기를 이용하여 후두의 좌우 대칭성, 설골 및 성문의 위치, 후두의 길이 및 좌우 갑상 연골이 이루는 각도 등을 계측하여 다음과 같은 결과를 얻었다. 1. 대부분의 경우에서 후두구조는 어느 정도 비대칭성을 보였고 우측편위가 좌측편위보다 많았으며 성별 및 연령별에 따라 의의있는 차이는 없었다. 2. 설골의 높이는 제 2-3경추 부위에서 제 5-6경추 부위까지 위치하고 있었고 제 3-4경추 부위 가 가장 흔한 부위였다. 3. 성문의 높이는 제 4경추 부위에서 제 6-7경추간까지 위치하고 있었고 제 5경추 부위가 가장 흔한 부위였다. 4. 양측 갑상연골이 이루는 각도는 58도에서 100도까지 다양하였고 평균 81.5도였으며, 평균각도는 남성에서 77.24도, 여성에서 87.88도였다.

  • PDF

척수손상 흰 쥐의 운동기능 회복에 미치는 손상부위 직접자극을 통한 기능적 자기자극치료 효과 (The Effect of Direct Functional Magnetic Stimulation of the Lesion on Functional Motor Recovery in Spinal Cord Injured Rat)

  • 조윤우;김수정;박해운;서정민;황세진;장성호;이동규;안상호
    • The Journal of Korean Physical Therapy
    • /
    • 제23권1호
    • /
    • pp.53-58
    • /
    • 2011
  • Purpose: The purpose of this study was to determine the effect of direct functional magnetic stimulation (FMS) of affected spinal cord on motor recovery following spinal cord injury in rats. Methods: After a contusion injury at the spinal level T9 using an NYU Impactor, functional magnetic stimulation was delivered by a magnetic stimulator through a round prototype coil (7 cm in diameter). Stimulation parameters were set as follows: repetition rate = 50 Hz (stimulus intensity 100% = 0.18 T), stimulation time = 20 min. Functional magnetic stimulation was administered twice a day, 5 days per week for 8 weeks starting 4 days after spinal cord injury. Functional magnetic stimulationwas delivered directly to the affected spinal cord. Outcomes of locomotor performance were assessed by the Basso Beattie Bresnahan (BBB) locomotor rating scale and by an inclined plane test weekly for 8 weeks. Results: In the BBB test, hindlimb motor function in the Functional magnetic stimulation group improved significantly more compared to the control group at 3, 4, 6, 7, and 8 weeks (p<0.05). In the inclined plane test, the angle of the plane in the functional magnetic stimulation group increased significantly more compared to the control group at 4, 5, 7, and 8 weeks (p<0.05). Conclusion: Our results demonstrate that direct Functional magnetic stimulation of the lesional site may have beneficial effects on motor improvement after spinal cord injury.

Ganglioglioma in Brainstem : Case Report and a Review of Literatures

  • Kim, Sung-Duk;Kim, Jong Hyun;Lee, Cheol-Young;Kim, Hyun-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • 제55권3호
    • /
    • pp.164-166
    • /
    • 2014
  • Ganglioglioma is an infrequent tumor of the central nervous system (CNS); mostly supratentorial region. But, they can occur anywhere in the central nervous system such as brainstem, cerebellopontine angle (CPA), thalamus, optic nerve and spinal cord. Although it occurs rarely, ganglioglioma should be included in the differential diagnosis of a posterior fossa mass because early recognition is important for treatment and patient counseling.

흉요추 방출성 압박골절의 Z-plate를 이용한 고정술후 추적검사 결과 (Follow-up Results of Z-plate Fixation in the Thoracolumbar Burst Fracture)

  • 심병수;김근수;이정청
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권6호
    • /
    • pp.763-771
    • /
    • 2000
  • Objectives : Thoracolumbar burst fractures(TBLF) result in not only compressive deformity of vertebral body but also spinal cord compression by bony fragments. Many thoracolumbar burst fractures demand both anterior decompression and intervertebral fusion. Most of spinal surgeons use anterior instrumentation for anteior intervertebral bony fusion. The use of Z-plate has been increased recently, however there has been only a few reports regarding its clinical long-term strength. We studied nineteen patients with TBLF to find out the long-term stability of Z-plate. Methods : We have operated 19 patients from March 1996 to August 1998. They were treated with anterior decompression through either a transthoracic, retroperitoneal extrapleural or retroperitoneal approach. Retropulsed bony fragments were removed completely by corpectomy. Iliac bone graft was used for interbody fusion in all of the cases. They were evaluated by plain X-ray films including flexion and extention lateral films. Cobbs angle was used to evaluate kyphotic and lateral wedging deformity. Results : Burst fractured sites were T11 in two, three T12, nine L1, and five L2. Mean follow-up duration was fifteen months. Preoperative average kyphotic angle was 23.7 degree. Immediate postoperative kyphotic angle was 10.2 degree. Follow-up resluts of average kyphotic angles revealed 14 degrees. Four patients(21%), including two spinal 3-column injury, showed increasement of kyphotic angle more than 5 degree or breakage of intrumentation. Two patients showed the difference of kyphotic angle more than 3 degree. Five patients(26%) revealed lateral wedging deformity more than 3 degrees. Postoperative complications were two meralgia parestheticas, one pulmonary atelectasis and two donor site infections. Four of the eight patients, who initially showed incomplete spinal cord deficits, were nerologically improved by Frankel's grade. Conclusion : Z-plate fixation and iliac bone graft after anterior decompression in thoracolumbar burst fractures is a safe and easy method. Immediate postoperative results revealed excellent correction of posttraumatic kyphosis, but long-term follow-up evalution showed insufficient strength. Therefore we believe that use of Z-plate should be carefully decided, especially in the case of large lumbar fracture or 3-column injury.

  • PDF

전침자극이 중추신경계 손상 흰쥐에서 CK, ALP, IgG 효소활성도에 미치는 영향 (The Effect of Electroacupuncture on Concentration and Activity of CK, ALP, and IgG in Serum and Central Nervous System of Rats)

  • 하미숙;박래준
    • The Journal of Korean Physical Therapy
    • /
    • 제22권2호
    • /
    • pp.47-53
    • /
    • 2010
  • Purpose: This study investigated the effect of electroacupuncture stimulation on changes in blood biochemistry in spinal cord injury (SCI) rats whose cords were damaged by 6-hydroxydopamine (6-OHDA). Methods: Twenty-one Sprague-Dawley adult male rats were assigned to one of three groups: normal (n=7), control (n=7) and experimental group (n=7). The experimental group received electroacupuncture (Es-160, ITO, Japan) for 15 minutes in the form of low frequency (2 Hz) stimulation to the zusanli point. After treatment, we observed motor behavior recovery using the inclined plane test. We also measured serum and CNS concentrations and activities of enzymes including creatine kinase (CK), alkaline phosphatase (ALP), and Immunoglobulin G (IgG). Statistical analysis was done using one-way analysis of variance (ANOVA). Results: Concentrations of CK, ALP and IgG were lower in the experimental group than in the control group. Functional recovery was evaluated by the maximal angle of the inclined board on which rats could maintain their initial position. This allowed us to monitor progressive locomotor recovery. The maximal angles of the inclined plane test were higher in the experimental group than in the control group (p<0.05). Conclusion: The results of this study showed that electroacupuncture to the zusanli point has a therapeutic effect on functional recovery after SCI.