In-vitro investigation of the mechanical friction properties of a computer-aided design and computer-aided manufacturing lingual bracket system under diverse tooth displacement condition

  • Kim, Do-Yoon;Ha, Sang-Woon;Cho, Il-Sik;Yang, Il-Hyung;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.49 no.2
    • /
    • pp.73-80
    • /
    • 2019
  • Objective: The purpose of this study was to compare the static (SFF) and kinetic frictional forces (KFF) of a computer-aided design and computer-aided manufacturing lingual bracket (CAD/CAM-LB) with those of conventional LB (Con-LB) and Con-LB with narrow bracket width (Con-LB-NBW) under 3 tooth displacement conditions. Methods: The samples were divided into 9 groups according to combinations of 3 LB types (CAD/CAM-LB [Incognito], Con-LB [7th Generation, 7G], and Con-LB-NBW [STb]) with 3 displacement conditions (no displacement [control], maxillary right lateral incisor with 1-mm palatal displacement [MXLI-PD], and maxillary right canine with 1-mm gingival displacement [MXC-GD]; n = 6/group). While drawing a 0.016-inch copper or super-elastic nickel-titanium archwire with 0.5 mm/min for 5 minutes in a chamber maintained at $36.5^{\circ}C$, SFF and KFF were measured. The Kruskal-Wallis method with Bonferroni correction was performed. Results: The Incognito group demonstrated the highest SFF, followed by the 7G and STb groups ([STb-control, STb-MXLI-PD, Stb-MXC-GD] < [7G-MXC-GD, 7G-MXLI-PD, 7G-control] < [Incognito-MXLI-PD, Incognito-control, Incognito-MXC-GD]; p < 0.001). However, there were no significant differences in SFF among the 3 displacement conditions within each bracket group. Within each displacement condition, the Incognito group demonstrated the highest KFF, followed by the 7G and STb groups ([STb-control, STb-MXLI-PD] < Stb-MXC-GD < 7G-MXLI-PD < [7G-control, 7G-MXC-GD] < [7G-MXC-GD, Incognito-MXLI-PD, Incognito-control] < [Incognito-control, Incognito-MXC-GD]; p < 0.001). MXC-GD exhibited higher KFFs than MXLI-PD in the same bracket group. Conclusions: The slot design and ligation method of the CAD/CAM-LB system should be modified to reduce SFF and KFF during the leveling/alignment stage.

Development of exothermic system based on internet of things for preventing damages in winter season and evaluation of applicability to railway vehicles

  • Kim, Heonyoung;Kang, Donghoon;Joo, Chulmin
    • Smart Structures and Systems
    • /
    • v.29 no.5
    • /
    • pp.653-660
    • /
    • 2022
  • Gravel scattering that is generated during operation of high-speed railway vehicle is cause to damage of vehicle such as windows, axle protector and so on. Especially, those are frequently occurred in winter season when snow ice is generated easily. Above all, damage of vehicle windows has not only caused maintenance cost but also increased psychological anxiety of passengers. Various methods such as heating system using copper wire, heating jacket and heating air are applied to remove snow ice generated on the under-body of vehicle. However, the methods require much run-time and man power which can be low effectiveness of work. Therefore, this paper shows that large-area heating system was developed based on heating coat in order to fundamentally prevent snow ice damage on high-speed railway vehicle in the winter season. This system gives users high convenience because that can remotely control the heating system using IoT-based wireless communication. For evaluating the applicability to railroad sites, a field test on an actual high-speed railroad operation was conducted by applying these techniques to the brake cylinder of a high-speed railroad vehicle. From the results, it evaluated how input voltage and electric power per unit area of the heating specimen influences exothermic performance to draw the permit power condition for icing. In the future, if the system developed in the study is applied at the railroad site, it may be used as a technique for preventing all types of damages occurring due to snow ice in winter.

Covid-19 disaster text notificatioin service using location-based (위치기반을 이용한 코로나 재난 문자 알림 서비스)

  • Kim, Ga-eul;Moon, Seon-yun;Lee, Tae-heon;Park, Min-sook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.395-396
    • /
    • 2021
  • We have changed a lot in our lives because of a disease called Covid-19.One of the biggest changes is to check the "disaster notification character" service spent in the country every time it is sent in real time. By the way, we cannot accept the characters of other regional disasters other than the area where we live. After visiting other areas, when we returned to the area where we relocated, we experienced difficulty in confirming the flow lines because we could not receive the characters of the flow lines of the corona confirmed persons in the visited areas separately. And if you use the broadcast-type broadcast service, you will not receive unnecessary copper wire information, and you will be able to obtain the characters of the disaster only where we visited. We try to provide app services to provide the public with more accurate and reliable information.

  • PDF

A Study on the Analysis of the Trends and Expression Techniques of Flower Jewelry (플라워 주얼리의 디자인 트렌드와 표현기법 분석에 관한 연구)

  • Kim, Yeon Hee;Kim, Mi Jin;Yun, Suk Young;Choi, Byung Jin
    • Journal of the Korean Society of Floral Art and Design
    • /
    • no.43
    • /
    • pp.123-138
    • /
    • 2020
  • This study found Flower Jewelry works in the monthly magazine specializing in flower decoration for nine years from 2011 to 2019. Based on the analysis of the type of expression, method of expression, type and number of plant materials used, and the type and number of non-plant materials used for the flower jewelry found, it was conducted to find out the trend of flower jewelry in Korea. By expression type, a total of 96 works were analyzed as 20.83% for headdresses, 57.29% for necklaces, 5.21% for earrings, 6.25% for lists, and 10.42% for other works(χ2=94.833, p<.001). According to the analysis of the frequency of use of expression techniques, headdresses, necklaces, and lists for each work were produced using five to six different expression techniques and earrings were produced using two to four expression techniques. Material coupling techniques 34.43%, flower and leaf utilization 30.17%, visual techniques 16.63%, collectivization techniques 14.12%, technical highlighting techniques 4.26%, and other 0.39% (χ2=455.222, p<.001). The most frequently used techniques were framing techniques 16.63% and knotting techniques 16.44%. Plant materials used in flower jewelry were found to be 22.61% for Phalaenopsis spp., 13.48% for Gomphrena globosa, 9.57% for Gloriosa rothschildiana, 7.39% for Epidendrum cinnabarinum, 6.96% for Chamelaucium uncinatum and 4.78% for Craspedia globosa (χ2=718.104, p<.001). In the case of branch, the most common was used with 70.00% of the Cornus walteri, and 10.00% of Actinidia arguta, Celastrus orbiculatus, and Salix pseudolasiogyne were used respectively (χ2=10.800, p=.013). In the case of foliage, 24.65% Aspidistra elatior, 24.62% Asparagus asparagoides, 11.54% Senecio rowleyanus, and 6.15% Ceropegia woodii (χ2=269.385, p<.001). In the case of berries, 44.44% of the fruits of the Smilax china, 33.33% of the Hypericum patulum, and 11.11% of the Phytolacca americana were found (χ2=11.444, p =.022). Non-planting materials used in the manufacture of flower jewelry were found to be 47.34% of 2mm aluminium wire, 33.73% of copper wire and 10.06% of 1mm aluminum wire (χ2=186.704, p<.001). The figure was 53.57% for pearls, 12.50% for ribbons, and 4.14% for spangles and feathers.

A Study on the Characteristics Analysis of Hybrid Choke Coil with Reduced Parasitic Capacitance suitable for LED-TV SMPS (LED-TV용(用) 전원장치에 적합한 기생 커패시턴스 저감형 Hybrid 초크 코일의 특성 해석에 관한 연구)

  • Lee, Jong-Hyeon;Kim, Gu-Yong;Kim, Jong-Hae
    • Journal of IKEEE
    • /
    • v.22 no.1
    • /
    • pp.185-188
    • /
    • 2018
  • This paper describes the parasitic capacitance modeling according to the coil structure, section bobbin and winding method for hybrid choke coil with reduced parasitic capacitance capable of the EMI attenuation of broad bands from lower frequency to higher frequency applied in the EMI attenuation filter of LED-TV SMPS. Especially, the hybrid choke coil with reduced parasitic capacitance($C_p$) proposed in this paper can reduces the parasitic capacitance($C_p$) by adopting the winding methods of rectangular copper wire, compared to the conventional common mode choke coil with the winding method of automatic type. The first resonant frequency of the proposed hybrid choke coil has a tendency to increase as the parasitic capacitance is smaller and its impedance characteristics, especially in the high frequency bands, improves as the first resonant frequency increases. In the future, the proposed hybrid choke coil with reduced parasitic capacitance shows it can be actually utilized in not only LED-TV SMPS but also various applications such as LED Lighting, Note-PC Adapter, and so forth.

Characteristics of Electomigration & Surface Hardness about Tungsten-Carbon-Nitrogen(W-C-N) Related Diffusion Barrier (W-C-N 확산방지막의 전자거동(ElectroMigration) 특성과 표면 강도(Surface Hardness) 특성 연구)

  • Kim, Soo-In;Hwang, Young-Joo;Ham, Dong-Shik;Nho, Jae-Kue;Lee, Jae-Yun;Park, Jun;Ahn, Chan-Goen;Kim, Chang-Seong;Oh, Chan-Woo;Yoo, Kyeng-Hwan;Lee, Chang-Woo
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.3
    • /
    • pp.203-207
    • /
    • 2009
  • Copper is known as a replacement for aluminum wire which is used for semiconductor. Because specific resistance of Cu ($1.67{\mu}{\Omega}$-cm) is lower than that of Al ($2.66{\mu}{\Omega}$-cm), Cu reduce RC delay time. Although melting point of Cu($1085^{\circ}C$) is higher than melting point of Al, Cu have characteristic to easily react with Silicon(Si) in low temperature, and it isn't good at adhesive strength with Si. For above these reason, research of diffusion barrier to prevent reaction between Cu and Si and to raise adhesive strength is steadily advanced. Our study group have researched on W-C-N (tungsten-carbon-nitrogen) Diffusion barrier for preventing diffusion of Cu through semiconductor. By recent studies, It's reported that W-C-N diffusion barrier can even precent Cu and Si diffusing effectively at high temperature. In this treatise, we vaporized different proportion of N into diffusion barrier to research Cu's Electromigration based on the results and studied surface hardness in the heat process using nano scale indentation system. We gain that diffusion barrier containing nitrogen is more stable for Cu's electromigration and has stronger surface hardness in heat treatment process.

A Study for Frequency Characteristics of Solenoid-Type RF Chip Inductors (크기에 따른 솔레노이드 형태 RF 칩 인덕터의 주파수 특성 연구)

  • Kim, Jae-Wook
    • Journal of IKEEE
    • /
    • v.11 no.4
    • /
    • pp.145-151
    • /
    • 2007
  • In this work, small-size, high-performance solenoid-type RF chip inductors utilizing a low-loss ${Al_2}{O_3}$ core material were investigated. The size of the chip inductors fabricated in this work were $0.86{\times}0.46{\times}0.45m^3$, $1.5{\times}1.0{\times}0.7m^3$, $2.1{\times}1.5{\times}1.0m^3$, and $2.4{\times}2.0{\times}1.4m^3$ and copper (Cu) wire with $27{\sim}40{\mu}m$ diameter was used as the coils. High frequency characteristics of the inductance, quality factor, and impedance of developed inductors were measured using an RF Impedance/Material Analyzer (HP4291B with HP16193A test fixture). It was observed that the developed inductors with the number of turns of 7 have the inductance of 13 to 100nH and exhibit the self-resonant frequency (SRF) of 6.4 to 1.1GHz. The SRF of inductors decreases with increasing the inductance and the inductors have the quality factor of 50 to 80 in the frequency range of 300MHz to 1.3GHz. In this study, small-size solenoid-type RF chip inductors with high inductance and high quality factor were fabricated successfully.

  • PDF

Improvement of Consolidation Characteristics around PVD Using the Thermal Method (열적 방법을 이용한 연직배수재 주변의 압밀특성 연구)

  • Bergado, Dennes T.;Shin, Eun-Chul;Park, Jeong-Jun
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.10
    • /
    • pp.5-11
    • /
    • 2007
  • This paper is to investigate the removal of the smear at elevated temperatures. This study utilized both small cylinder cell and large consolidometer apparatus to investigate the combination of PVD with heat and without heat. Two types of heaters are used in this study. The heater drain made of copper tube is used for all tests except large consolidometer and flexible wire heater is used for large consolidometer. Specimens demonstrated volume contraction upon heat and without heat. This contraction is dependent on temperature magnitude. When the specimen is heated, the magnitude of settlements is higher and rate of consolidation is faster. After treatment using PVD combined without heat and with heat for undisturbed specimens the $C_h$ values obtained were $3.45m^2/yr$ and $3.83m^2/yr$, respectively, from $3.2m^2/yr$ before treatment. The $K_h/K_s$ ratios were 3 for the specimen without heat and 2 for the specimen with heat. Similarly, in reconstituted specimens without heat and with heat, the $C_h$ values were $2.1m^2/yr$ and $2.5m^2/yr$ with $K_h/K_s$ ratios of 1.75 and 1.5, respectively.

Reduction of Artifacts in Magnetic Resonance Imaging with Diamagnetic Substance (반자성 물질을 이용한 자기공명영상검사에서의 인공물 감소)

  • Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.581-588
    • /
    • 2019
  • MRI is superior when contrasted to help the organization generate artifacts resolution, but also affect the diagnosis and create a image that can not be read. Metal is inserted into the tooth, it is necessary to often be inhibited in imaging by causing the geometric distortion due to the majority and if the difference between the magnetic susceptibility of a ferromagnetic material or paramagnetic reducing them. The purpose of this study is to conduct a metal artefact in accordance with the analysis using a diamagnetic material. The magnetic material include a wire for the orthodontic bracket and a stainless steel was used as a diamagnetic material was used copper, zinc, bismuth. Testing equipment is sequenced using 1.5T, 3T was used was measured using a SE, TSE, GE, EPI. A self-produced phantom material was used for agarose gel (10%) to a uniform signal artifacts causing materials are stainless steel were tested by placing in the center of the phantom and cover inspection of the positive cube diamagnetic material of 10mm each length.After a measurement artefact artifact zone settings area was calculated using the Wand tool After setting the Low Threshold value of 10 in the image obtained by subtracting images, including magnetic material from a pure tool phantom images using Image J. Metal artifacts occur in stainless steel metal artifact reduction was greatest in the image with the bismuth diamagnetic materials of copper and zinc is slightly reduced, but the difference in degree will not greater. The reason for this is thought to be due to hayeotgi offset most of the susceptibility in bismuth diamagnetic susceptibility of most small ferromagnetic. Most came with less artifacts in image of bismuth in both 1.5T and 3T. Sequence-specific artifact reduction was most reduced artifacts from the TSE 1.5T 3T was reduced in the most artifacts from SE. Signal-to-noise ratio was the lowest SNR is low, appears in the implant, the 1.5T was the Implant + Bi Cu and Zn showed similar results to each other. Therefore, the results of artifacts variation of diamagnetic material, magnetic susceptibility (${\chi}$) is the most this shows the reduced aspect lower than the implant artificial metal artifacts criteria in the video using low bismuth susceptibility to low material the more metal artifacts It was found that the decrease. Therefore, based on the study on the increase, the metal artifacts reduction for the whole, as well as dental prosthesis future orthodontic materials in a way that can even reduce the artifact does not appear which has been pointed out as a disadvantage of the solutions of conventional metal artifact It is considered to be material.

Analysis of Heavy Metals in $[^{201}Tl]$TICI Injection Using Polarography (폴라로그래피를 이용한 $[^{201}Tl]$염화탈륨 주사액의 중금속 분석)

  • Chun, Kwon-Soo;Suh, Yong-Sup;Yang, Seung-Dae;Ahn, Soon-Hyuk;Kim, Sang-Wook;Choi, Kang-Hyuk;Lee, Dong-Hoon;Lim, Sang-Moo;Yu, Kook-Hyun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.336-343
    • /
    • 2000
  • Purpose: Thallous-201 chloride produced at Korea Cancer Center Hospital(KCCH) is used in detecting cardiovascular disease and cancer. Thallium impurity can cause emesis, catharsis and nausea, so the presence of thallium and other metal impurities should be determined. According to USP and KP, their amounts must be less than 2 ppm in thallium and 5 ppm in total. In this study, the detection method of trace amounts of metal impurities in $[^{201}Tl]$TICI injection with polarography was optimized without environmental contamination. Materials and Methods: For the detection of metal impurities, Osteryoung Square Wave Stripping Voltammetry method was used in Bio-Analytical System (BAS) 50W polarograph. The voltammetry was composed of Dropping Mercury Electrode (DME) as a working electrode, Ag/AgCl as a reference electrode and Pt wire as a counter electrode. Square wave stripping method, which makes use of formation and deformation of amalgam, was adopted to determine the metal impurities, and pH 7 phosphate buffer was used as supporting electrolyte. Results: Tl, Cu and Pb in thallous-201 chloride solution were detected by scanning from 300 mV to -800 mV Calibration curves were made by using $TINO_3,\;CuSO_4\;and\;Pb(NO_3){_2}$ as standard solutions. Tl was confirmed at -450 mV peak potential and Cu at -50 mV Less than 2 ppm of Tl and Cu was detected and Pb was not detected in KCCH-produced thallous-201 chloride injection. Conclusion: Detection limit of thallium and copper is approximately 50 ppb with this method. As a result of this experiment, thallium and other metal impurities in thallous-201 chloride injection, produced at Korea Cancer Center Hospital, are in the regulation of USP and KP Polarograph could be applied for the determination of metal impurities in the quality control of radiopharmaceuticals conveniently without environmental contamination.