• 제목/요약/키워드: Copper tube

검색결과 264건 처리시간 0.02초

Numerical Predictions of Heat Transfer in the Fluidized Bed Heat Exchanger

  • Ahn, Soo-Whan
    • 농업생명과학연구
    • /
    • 제44권4호
    • /
    • pp.29-43
    • /
    • 2010
  • The numerical analysis by using CFX 11.0 commercial code was done for proper design of the heat exchanger. The present experimental studies were also conducted to investigate the effects of circulating solid particles on the characteristics of fluid flow, heat transfer and cleaning effect in the fluidized bed vertical shell and tube type heat exchanger with counterflow, at which a variety of solid particles such as glass ($3mm{\Phi}$), aluminum ($2{\sim}3mm{\Phi}$), steel ($2{\sim}2.5mm{\Phi}$), copper ($2.5mm{\Phi}$) and sand ($2{\sim}4mm{\Phi}$) were used in the fluidized bed with a smooth tube. Seven different solid particles have the same volume, and the effects of various parameters such as water flow rates, particle diameter, materials and geometry were investigated. The present experimental and numerical results showed that the flow velocity range for collision of particles to the tube wall was higher with heavier density solid particles, and the increase in heat transfer was in the order of sand, copper, steel, aluminum, and glass. This behavior might be attributed to the parameters such as surface roughness or particle heat capacity.

변형하는 가스 이송관 내에서 전파하는 탄화수소화염의 수치 해석 모델링 (Numerical simulation on propagation of hydrocarbon flame in a deformable tube)

  • 곽민철;여재익
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2012년도 제38회 춘계학술대회논문집
    • /
    • pp.304-308
    • /
    • 2012
  • 본 연구는 에틸렌-공기 혼합물로 채워져 있는 변형 가능한 구리 관에서의 초음속 화염 전파를 수치적으로 살펴보았다. 탄화수소의 화염 전파를 해석하기 위하여 지배방정식으로 Navier-Stokes 방정식과 Arrhenius 형태의 1단계 화학 반응식을 활용하였으며 변형 가능한 관을 해석하기 위하여 Inviscid Euler 방정식을 활용하였다. 또한, 두 물질 간 경계면 추적을 위하여 Level-set 기법을, 경계값 결정을 위하여 ghost fluid 기법을 사용하였다. 이러한 수치적 기법을 바탕으로 관의 변화에 따른 초음속 화염 내 팽창파의 전파 및 그에 따른 간섭 현상을 밀도 및 속도 변화를 통해 확인하였으며 초음속 화염 전파에도 안전성이 확보되는 최소 관 두께를 예측할 수 있는 수치적 기반을 마련하였다.

  • PDF

균일한 열유속에서의 수직동관내의 강제대류 열전달에 관한 연구 (A study on the forced convection heat transfer in the vertical copper tube at uniform wall heat flux)

  • 백고길;차지영;서정윤
    • 대한설비공학회지:설비저널
    • /
    • 제8권4호
    • /
    • pp.213-220
    • /
    • 1979
  • A number of methods has been developed for calculation of heat transfer in the vertical round tube under conditions of forced convection with uniform heat flux at wall. I would like to express hereby one of applications of this study in the design of heat exchanger instruments for water flow at $15.8^{\circ}C(p_r=8)$ used frequently in our daily life. Also all the results are investigated for forced convective heat transfer in the case of heated water-flow at uniform wall heat flux in the vortical round copper tube, where the ratio of length to diameter will be 44. They are well in agreement with Gratz and Kraussold equation respectively in laminar and transition flow range. In turbulent flow in the range from Re=10,000 to 65,000, the experimental formula Is show as follows ; Nu=0.023 $R_e^{0.814}\;P_r^{0.4}$. And this is agreed with Dittus - Boelter equation when Reynolds number exponent increases from 0.80 to 0.814.

  • PDF

세관내 R-22와 R-410A의 응축 압력강하 (The Condensation Pressure Drop of R-22 and R-410A in Small Diameter Tube)

  • 손창효
    • 한국수소및신에너지학회논문집
    • /
    • 제19권2호
    • /
    • pp.156-162
    • /
    • 2008
  • The condensation pressure drop for R-22 and R-410A flowing in a small diameter tube was investigated. The test section is a counterflow heat exchanger with refrigerant flowing in the inner tube and coolant flowing in the annulus. The test section consists of 1220 mm length with horizontal copper tube of 3.38 mm outer diameter and 1.77 mm inner diameter. The refrigerant mass fluxes ranged from 450 to $1050\;kg/m^2{\cdot}s$ and the average inlet and outlet qualities were 0.05 and 0.95, respectively. The main experimental results were summarized as follows : In the case of two-phase flow, the pressure drop increases with increasing mass flux and decreasing quality. The pressure drop of R-22 is slightly higher than that of R-410A for the same mass flux. Most of correlations proposed in the large diameter tube showed enormous deviations with experimental data.

Study on Heat Transfer Characteristics according to Flowing Particles in a Cold Water Tube

  • Park, Ki-Won;Kim, Myoung-Jun;Jung, Sung-Chan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권3호
    • /
    • pp.243-251
    • /
    • 2007
  • This experiment was conducted to investigate the effect of particles on the heat transfer characteristics of fluids flowing in a cold water tube. Plastic beads with 3 different sizes were used as flowing particles with cold water. An experimental test section was composed of concentric double tubes having diameters of 25mm for the inner tube and 50mm for the outer tube. The materials for the inner and outer tubes are copper and PVC respectively. It was found that the particles enhanced the heat transfer coefficient by random and vortex motion in the fluid. Hence the heat transfer coefficients for the fluid with 2mm, 5mm and $2{\times}6mm$ particles were $7%{\sim}37%$ higher than the fluid without the particles.

LiBr 수용액을 이용한 수평관 유하액막 증발의 촉진관 전열향상 특성 (Heat Transfer Enhancement Characteristics for Falling-Film Evaporation on Horizontal Enhanced Tubes with Aqueous LiBr Solution)

  • 김동관;김무환
    • 대한기계학회논문집B
    • /
    • 제22권9호
    • /
    • pp.1267-1276
    • /
    • 1998
  • Falling-film evaporation experiments with aqueous lithium bromide (LiBr) solution were performed to investigate the heat transfer characteristics of enhanced copper tubes. Enhanced tubes (a knurled tube, a spirally grooved tube, and a tube coated with $20{\mu}m$ aluminum particles) and a bare tube were selected as test specimens. Averaged evaporation fluxes of water were obtained from horizontal tubes with various film Reynolds numbers, system pressures, LiBr concentrations and degrees of wall superheat. The enhanced performance of steam generation was compared between tubes with varying parameters. The knurled tube geometry showed the most excellent performance among the tubes tested. The specified enhanced tubes were more useful for generating steam on a low grade heat source such as waste heat.

태양열 집열판의 레이저용접을 위한 공정변수 평가 (Evaluation of Process Parameter to Laser Welding of Solar Panel)

  • 김용;박기영;김부환
    • 한국레이저가공학회지
    • /
    • 제14권4호
    • /
    • pp.9-13
    • /
    • 2011
  • The solar panel that consists of copper plate and copper tube was successfully welded by ultrasonic seam welding. However it was not only expensive the copper material but also ultrasonic welding has many problem such as high error rate, difficulty of dissimilar material welding, noise, etc. At this study, the laser welding of solar panel with aluminum plate instead of copper. The welding were carried out with the pulsed Nd:YAG laser and the weld bead geometry was measured with the variation of pulse energy. Consequently, there was no difference between the ultrasonic and the laser welding on the performance of heat transfer capacities. Also the formation of intermetalic compound such as CuAl2 was increased with the pulse energy.

  • PDF

HCFC-123의 수평 평활관내 응축 전열 특성에 관한 연구 (Condensation Heat Transfer Characteristics of HCFC - 123 inside Horizontal Smooth Tube)

  • 권옥배;오후규;오종택;김성규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제17권3호
    • /
    • pp.24-32
    • /
    • 1993
  • Experimental data on the heat transfer characteristics of HCFC-123 and CFC-11 during condensation in horizontal smooth tube are presented. The experimental apparatus consisted of a closed working fluid loop, coolant loop, and measuring system. The major components of the working fluid loop made of a refrigerant pump, boiler, superheater, refrigerant flow meter, receiver and test section. The tube-in-tube type test section was made of smooth tube which were constructed form 9.52 mm outer diameter of smooth copper tube with 50 mm outside diameter of PVC tube duct. The ranges of parameter, such as refrigerant mass velocity, coolant flow rate, and quality were 90-325kg/($m^2$.s), 60-360kg/h, 5-95% respectively. Data were obtained under steady state condition for annular flow. As a result of these, the condensation heat transfer coefficients for HCFC-123 were slightly lower than those of CFC-11 from 8% to 15% inside horizontal smooth tube. Furthermore, a new generalized correlation for the heat transfer coefficients of HCFC-123 and CFC-11 during condensation inside horizontal smooth tube is proposed.

  • PDF

표면처리를 이용한 단일진공관과 기존 이중진공관 태양열집열기의 성능비교 연구 (Study on Performance Comparison for Solar Collectors with Single Evacuated Tube using Surface Treatment and Commercial Double Evacuated Tube)

  • 전태규;양영준;이경희;안영철
    • 한국기계가공학회지
    • /
    • 제12권5호
    • /
    • pp.149-156
    • /
    • 2013
  • The performances of solar collectors with single and double evacuated tube were experimentally compared. The solar collector with single evacuated tube using surface treatment in this study consists of radiation fin, heat pipe, absorber plate, glass tube, cap and regulating valve, and so on. Surface treatment was conducted for heat pipe and absorber plate with black chrome plating and copper black coating. As the results, the performance of solar collector with single evacuated tube using surface treatment showed good results compared that of double evacuated tube. Absorber plate played a positive role in performance and showed increase of about 28%. Further performance depends on vacuum degree and vacuum degree has to be considered economical efficiency in solar collector.

티타늄 평활관 및 전열촉진관에서 R-l34a의 관외측 풀비등 열전달 특성에 대한 연구 (Pool Boiling Heat Transfer Characteristics of R-l34a in Titanium Horizontal Plain and Low Finned Tubes)

  • 허재혁;윤린;정진택;문영준;김용찬
    • 대한기계학회논문집B
    • /
    • 제29권7호
    • /
    • pp.854-860
    • /
    • 2005
  • Pool boiling heat transfer characteristics of R-134a were investigated in titanium plain and low finned tubes. The diameter of test tube was 15.88 mm and the fin density was 33 fpi. Tests were conducted at saturation temperatures of $20^{\circ}C$ and $30^{\circ}C$. Heat fluxes varied from 5000 W/$m^2$ to 50,000 W/$m^2$ based on surface area of the plain tube. The pool boiling heat transfer coefficients of the titanium horizontal plain tube are lower than those of the copper plain tube by $8.2\%$. The boiling heat transfer coefficients of the low finned tube are averagely higher than those of the plain tubes by $34\%$. The average deviation of the Slipcevic correlation from the present data for the low finned tube is $20\%$.