Power Loss Analysis according to Winding Array Method of High Frequency Transformer (고주파 트랜스포머의 권선배열에 기법 따른 손실해석)

  • Yoon, Shin-Yong;Kim, IL-Nam
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.1
    • /
    • pp.15-19
    • /
    • 2005
  • This paper analyzed the power loss characteristics according to winding thickness and winding method of high frequency transformer. Power loss was analyzed by PExprt using FEM tool. The ferrite core model for analysis be used the EE10 type of TDK cop.. Transformer model objected flyback transformer type applied to flyback converter/inverter. Therefore, analysis results of loss were obtained from inner parameters of DC, AC resistance, leakage inductance, copper loss, core loss, and temperature etc.

Simple Equivalent Circuit for Efficiency Calculation of Brushless DC Motors

  • Ishikawa, Takeo;Tsuji, Takuma;Hashimoto, Seiji;Kurita, Nobuyuki
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.1
    • /
    • pp.54-60
    • /
    • 2014
  • This paper shows a calculation method of several types of loss and the efficiency of brushless DC motors coupled with a load system by using a simple equivalent circuit, in which copper loss, eddy current loss, hysteresis loss, friction loss, viscous loss, and inverter loss are taken into account. We clarify each loss and motor efficiency at different motor speeds and different output torques by using the Microsoft-Excel. Moreover, the calculated results are in good agreement with the measured ones.

Deformation of the Tubes in Copper/Brass Radiator with Rise of Temperature and Pressure (온도 및 압력상승에 따른 동/황동 라디에터 튜브의 변형)

  • 정명진
    • Journal of the Korean Society of Safety
    • /
    • v.8 no.4
    • /
    • pp.16-20
    • /
    • 1993
  • The combined effect of increased pressure/temperature and the reduced material thicknesses act to increase the stress on the radiator componets. The design life of the radiator is influenced by the cyclic stresses and corrosion, which act to weaken the materials, radiator mechanical failure occurs when a tube or solder Joint ruptures, causing coolant loss or insufficient heat rejection. Therefore, in this study, through strain measurement of the tubes in copper/brass radiator, the strain distribution of the tubes in radiator as function of temperature and pressure is obtained.

  • PDF

Corrosion Behaviour of Some Alloys in Tropical Urban and Marine Atmospheres

  • Dang, Vu Ngoan;Bui, Ba Xuan;Nguyen, Nhi Tru
    • Corrosion Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.125-129
    • /
    • 2008
  • Results of corrosion testing for different grades of titanium, copper, zinc, alluminium alloys and steels after two years of outdoor exposure under humid tropical urban and marine conditions have been presented and discussed. Mass loss and corrosion product characteristics for the exposed specimens at Hanoi testing site with high humidity and Nhatrang marine stations (at 100 and 1,000 meters distances from sea) with different airborne salinities (35.9 and $90.0mg/m^2.d$ respectively) have been selected for investigation. From time dependence of the specimen mass loss and corrosion product characteristics, the strong influence of environmental parameters upon durability for the investigated metals and alloys has been demonstrated. Only titanium alloys show high resistance to the marine conditions. All the other specimens (copper, zinc, alluminium alloys and steels) have been underwent strong deterioration under influence of aerosol salinity. Results of corrosion products analysis have been also presented for characterization of environmental impact on the metal degradation processes.

Hydrolysis of Tencel Fabrics by Cellulase Treatment (셀룰라아제 처리에 의한 텐셀직물의 가수분해)

  • 손경희;신윤숙
    • Korean Journal of Human Ecology
    • /
    • v.2 no.1
    • /
    • pp.142-148
    • /
    • 1999
  • Tencel fabrics were treated with cellulase after mechanical prefibrillation treatment. SEM analysis was carried out to study morphological change of the treated fabric. The cellulase-treated Tencel fabrics were evaluated for weight loss and tensile strength. X-ray diffraction method, moisture regain, and K/S value were used to elucidate crystalline structural changes occurred by cellulase treatment. Degree of polymerization and copper number of the cellulase-treated fabrics were also measured to estimate effect of hydrolysis. SEM analysis indicated that with treatment of prefibrillation and cellulase, fibrils were produced and damage occurred deep into the fiber. Increases in concentration and time of cellulase treatment increased weight loss and decreased tensile strength retention of the treated fabrics. As cellulase hydrolysis progressed, degree of crystallinity, moisture regain and K/S value were not much changed. (Korean J Human Ecology 2(1) : 142∼148, 1999)

  • PDF

Microfiltration/ultrafiltration polyamide-6 membranes for copper removal from aqueous solutions

  • El-Gendi, Ayman;Ali, Sahar;Abdalla, Heba;Saied, Marwa
    • Membrane and Water Treatment
    • /
    • v.7 no.1
    • /
    • pp.55-70
    • /
    • 2016
  • Microfiltration/ultrafiltration (MF/UF) Adsorptive polyamide-6 (PA-6) membranes were prepared using wet phase inversion process. The prepared PA-6 membranes are characterized by scanning electron microscopy (SEM), porosity and swelling degree. In this study, the membranes performance has examined by adsorptive removal of copper ions from aqueous solutions in a batch adsorption mode. The $PA-6/H_2O$ membranes display sponge like and highly porous structures, with porosities of 41-73%. Under the conditions examined, the adsorption experiments have showed that the $PA-6/H_2O$ membranes had a good adsorption capacity (up to 120-280 mg/g at the initial copper ion concentration ($C_0$) = 680 mg/L, pH7), fast adsorption rates and short adsorption equilibrium times (less than 1.5-2 hrs) for copper ions. The fast adsorption in this study may be attributed to the high porosities and large pore sizes of the $PA-6/H_2O$ membranes, which have facilitated the transport of copper ions to the adsorption. The results obtained from the study illustrated that the copper ions which have adsorbed on the polyamide membranes can be effectively desorbed in an Ethylene dinitrilotetra acetic acid Di sodium salt ($Na_2$ EDTA) solution from initial concentration (up to 92% desorption efficiency) and the PA-6 membranes can be reused almost without loss of the adsorption capacity for copper ions. The results obtained from the study suggested that the $PA-6/H_2O$ membranes can be effectively applied for the adsorptive removal of copper ions from aqueous solutions.

Selection of Optimal Values in Spatial Estimation of Environmental Variables using Geostatistical Simulation and Loss Functions

  • Park, No-Wook
    • Journal of the Korean earth science society
    • /
    • v.31 no.5
    • /
    • pp.437-447
    • /
    • 2010
  • Spatial estimation of environmental variables has been regarded as an important preliminary procedure for decision-making. A minimum variance criterion, which has often been adopted in traditional kriging algorithms, does not always guarantee the optimal estimates for subsequent decision-making processes. In this paper, a geostatistical framework is illustrated that consists of uncertainty modeling via stochastic simulation and risk modeling based on loss functions for the selection of optimal estimates. Loss functions that quantify the impact of choosing any estimate different from the unknown true value are linked to geostatistical simulation. A hybrid loss function is especially presented to account for the different impact of over- and underestimation of different land-use types. The loss function-specific estimates that minimize the expected loss are chosen as optimal estimates. The applicability of the geostatistical framework is demonstrated and discussed through a case study of copper mapping.

Loss Modeling in order to Predict the Efficiency Performance of Induction Motor Drive System (유도전동기 드라이브 시스템의 효율성능을 예측하기 위한 손실 모델링)

  • 정동화;박기태;이정철
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.4
    • /
    • pp.56-61
    • /
    • 2000
  • The precise and reliable loss model for induction motor and converter system is very important in order to predict the efficiency performance of variable speed drives. This paper proposes an accurate loss model of induction motor and converter system. The motor losses, such as stator and rotor copper loss, core loss and stray loss, are considered for fundamental and harmonic frequencies. Also considered are the skin effect on rotor resistance, temperature effect on bath stator and rotor resistance, magnetizing inductance saturation, and friction and windage loss. All the above features are incorporated in a synchronous frame dynamic d-q equivalent circuit. The converter system, consisting of a diode rectifier and PWM transistor inverter, is modeled accurately for conduction and switching losses. Validity of the models, in both steady state and transient conditions, is verified by simulations.

  • PDF

Effect of Pt Layers on the Photoelectrochemical Properties and Stability of a Copper Oxide/n-Si Electrode (Copper oxide/n-Si 전극의 광전기화학 변환 특성과 안정성에 미치는 Pt 층의 영향)

  • 윤기현;홍석건;강동헌
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.3
    • /
    • pp.263-270
    • /
    • 2000
  • The Pt/copper oxide/n-Si electrodes were fabricated by depositing copper oxide thin film of 500${\AA}$ and very thin Pt layer on the n-type (100) Si substrate. hotoelectrochemical properties and stability profiles of the electrodes were investigated as a function of deposition time of Pt layer. As the deposition time of Pt layer increased up to 10 seconds, the photocurrent and quantum efficiency were increased and then decreased with further depositing time. The better cell stability was observed for the electrode with longer deposition time. The improvements in above photoelectrochemical properties indicate that Pt layer acts as a catalyst layer at electrode/electrolyte interface as well as a protective layer. The decreasing tendency of the photocurrent and efficiency for the electrode with Pt layer deposited above 20 seconds was explained as an increases in probbility of electron-hole pair recombination and also the absorbing photon loss at electrode surface due to the excessive thickness of Pt layer. The results were confirmed by impedance spectroscopy, mutiple cycle voltammograms and microstructural analyses.

  • PDF

Magnetic Field Distribution Analysis for Core Loss Estimation of Permanent Magnet Machine (영구자석 기기의 철손 예측을 위한 자계 거동 해석)

  • Jang, Seok-Myeong;Ko, Kyoung-Jin;Choi, Jang-Young;Park, Ji-Hoon;Lee, Sung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.10c
    • /
    • pp.93-95
    • /
    • 2008
  • Nowadays more attention is paid to the developing high efficiency electrical machines for energy saving and protection of natural resources. In general, the electromagnetic losses appearing in electrical machines are widely classified into copper loss, core loss and rotor loss. Particularly, in permanent magnet (PM) machines, core loss forms a larger portion of the total losses than in another machine. So, satisfactory prediction of core loss at the design or analysis stage of PM machines is essential to active high efficiency and high performance. This paper deals with analysis of magnetic field distribution due to geometry of stator core for magnetic core loss calculation of multi-pole PM synchronous machine.

  • PDF