• 제목/요약/키워드: Cooling textiles

검색결과 36건 처리시간 0.024초

냉감소재를 사용한 여름철 의류의 구매행동과 디자인 선호도 연구 (A Study on Clothing Purchasing Behaviors and Design Preference of Summer Clothes using Cooling Textiles)

  • 권은순;이미숙
    • 한국의상디자인학회지
    • /
    • 제16권2호
    • /
    • pp.55-70
    • /
    • 2014
  • The purpose of this study was to investigate purchasing behaviors of summer clothes using cooling textiles and clothing design preference in summer season. The subjects were 623 married women aged from 30s to 60s. The research method was a survey and the measuring instruments consisted of purchasing behaviors of summer clothes using cooling textiles, clothing design preference in summer season, and subjects' demographics attributions. The data were analyzed by frequency analysis, multiple response analysis, cross tabs analysis, and $x^2$ test, using SPSS statistical program. The results were as follows. First, important clothing selection criteria were design, price, and textiles. The main items using cooling textiles that female consumers purchased were T-shirts, pants, and outdoor & sportswear. Main information sources of summer clothes using cooling textiles were internet and store display, and purchasing places were fashion outlet, internet, brand store, and department store. Second, female consumers most preferred comfortable and casual style. They mainly preferred white and blue color, pastel and pale tone, plain pattern, and cotton and functional materials in summer season. Third, there were many important differences among 4 age groups on purchasing behaviors of summer clothes using cooling textiles and design preference in summer season.

  • PDF

고온환경 작업을 위한 펠티어 소자 냉각복 개발 및 쾌적성 평가 (Development of Cooling Garment for Extremely Hot Environment Using a Peltier Device and its Comfort Properties)

  • 정예리;채영진;김은애
    • 한국의류학회지
    • /
    • 제36권1호
    • /
    • pp.1-11
    • /
    • 2012
  • This paper reports on a prototype cooling garment applying a cooling module. The cooling module was composed of a Peltier device, a cold sink, a heat sink and two fans. A constant box was used to evaluate the cooling effect of the module. Two cooling modules were attached on each side of the garment. The wear trial was conducted using 10 male subjects in an environmental chamber maintained at $30{\pm}0.5^{\circ}C$, $50{\pm}5%$RH. Subjective sensations of thermal, humidity, and comfort were surveyed. Statistical package SPSS12.0 was used for the t-test and the Wilcoxon signed-rank test. The results showed that most effective cooling module decreased the temperature of the constant temperature box by $-4.9^{\circ}C$. The micro-temperature of the cooling garment with a Peltier device was lower than the control garment during the exercise. In particular, the chest skin temperature was $1.5^{\circ}C$ lower with the cooling garment than the control. The maximum temperature difference was $-2.57^{\circ}C$ on the sides of the $1^{st}$ layer. Subjective thermal sensation from wear trials of the Peltier device attached garment was lower than the control garment. Subjects felt more comfortable with the cooling garment in almost all the periods.

냉각복 개발을 위한 효율적 냉각부위 규명에 관한 연구 (Study of Efficient Cooling Part for Cooling Clothes Development)

  • 최정화;황경숙
    • 한국의류학회지
    • /
    • 제26권6호
    • /
    • pp.771-778
    • /
    • 2002
  • Cooling clothes especially cooling vest are being considered for as an efficient way to reduce heat strain under hot environment. But wearing ice gel or ice-based cooling vest caused discomfort to subjects due to the weight of vest. Therefore, this study was executed to find efficient cooling parts and to reduce vest weight by cooling only these parts. Two male subjects were exposed to heat(40$^{\circ}C$, 30%RH) with A type(breast+back+abdomen+waist), B type(breast+back+waist), C type(breast+back+abdomen) and D type(breast+back) cooling vest that distinguished with cooling part. The results were as follows; When subjects were C type and D type vest, sweat volume was less and skin temperature was low. Heart rate and rectal temperature were low in B type and D type. These results suggest that excessive cooling of breast and abdomen may exert a bad influence to health and cooling of back is desirable.

여름철 작업자들의 고체온증 예방을 위한 액체냉각복 개발 및 효과적인 냉각온도와 인체 냉각부위 탐색 (Developing Liquid Cooling Garments to Alleviate Heat Strain of Workers in Summer and Exploring Effective Cooling Temperature and Body Regions)

  • 정재연;강주호;설선홍;이주영
    • 한국의류산업학회지
    • /
    • 제22권2호
    • /
    • pp.250-260
    • /
    • 2020
  • The purpose of the present study was to explore the most effective body region and cooling temperature to alleviate heat strain of workers in hot environments. We developed liquid cooling hood, vest, sleeves and socks and applied the water temperatures of 10, 15, 20, and 25℃ through the liquid cooling garments in a hot and humid environment (33℃ air temperature and 70% RH air humidity). A healthy young male participated in a total of 16 experimental trials (four cooling garments × four cooling temperatures) with the following protocol: 10-min rest, 40-min exercise on a treadmill and 10-min recovery. The results showed that rectal temperature, mean skin temperature, and ratings of perceived exertion during exercise; heart rate and diastolic blood pressure during recovery; and total sweat rate were lower for the vest condition than other garment conditions(p < .05). However, there was no differences in mean skin temperature among the four cooling garments when we compared the values converted by covering area(%BSA). When we classified the results by cooling temperature, there were no consistent differences in thermoregulatory and cardiovascular responses among the four temperatures, but 25℃ water temperature was evaluated as being the most ineffective cooling temperature in terms of subjective responses. In conclusion, the results indicated that wearing cooling vest with < 20℃ cooling temperature can alleviate heat strain of workers in hot and humid environments. If the peripheral body regions are cooled with liquid cooling garments, larger cooling area with lower cooling temperature than 10℃ would be effective to reduce heat strain of workers. Further studies with a vaild number of subjects are required.

여름철 농민의 서열 부담 경감을 위한 냉각조끼의 성능 평가 (Efficacy of Cooling Vests for Alleviating Heat Strain of Farm Workers in Summer)

  • 최정화;김명주;이주영
    • 한국의류학회지
    • /
    • 제29권8호
    • /
    • pp.1176-1187
    • /
    • 2005
  • The purpose of this study was to evaluate the efficiency of cooling vests developed for farm workers harvesting red pepper in summer. The study was performed using the following two steps: 1) Climatic chamber test, 2) Field test. For the chamber test, a work environment was simulated as $33^{\circ}C$ and $65\%$RH, and the thermo-physiological and subjective responses were measured with and without cooling vests. Twelve young males participated as subjects. For the field test, three farmers participated while harvesting red pepper on the form, in summer. The measurements used were same as in the chamber test. Subjects were tested without any cooling vests, as a control. They were tested wearing vests with 2 frozen gel packs (CV2: Cooling area, $308cm^2$), and vests with 4 frozen gel packs (CV4: Sooting area, $616cm^2$). As a result of the chamber test, rectal temperature($T_{re}$) and mean skin temperature( $T_{sk}$) were lower in both CVs than in Control, and this tendency was statistically significant in CV4 (p<.05). Clothing microclimate temperature ($T_{clo}$) and total sweat rate (TSR) were significantly lower when wearing cooling vests (p<.05) Heart rate (HR) was also lower in wearing cooling vests than in Control, and the speed of recovery to the comfort level was faster when the subjects wore cooling vests. In addition, subjects felt 'less hot, less humid, and less uncomfortable' in both CVs than in Control. Field tests showed a similar tendency with the chamber tests. In particular, wearing the cooling vest was effective in restraining the raise of $T_{clo}$ on the back. It can be concluded that the cooling vest was effective in alleviating heat strain and discomfort in both the chamber test and the field test, despite the cooling area of the cooling vest being just $3.4\%$ of the body surface area ($616cm^2$).

더운환경에서의 냉각조끼의 착용효과에 관한 연구 (Effectiveness of Cooling Vest in Hot Environment)

  • 최정화;황경숙
    • 한국의류학회지
    • /
    • 제25권1호
    • /
    • pp.83-90
    • /
    • 2001
  • Cooling garments are being considered for reducing heat strain in hot environment. We evaluated the effectiveness of ice gel-based cooling vest in hot environment both resting and exercising. Four male subjects were exposed to heat(4$0^{\circ}C$, 50%RH) with vest or without it. The results were as follows; In case of the trial wearing ice gel-based cooling vest, total body weight loss, and local sweat volume were less than those without it. Mean skin temperature, rectal temperature, pulse, energy expenditure, temperature of inside clothes, and humidity of inside also were lower than those without cooling vest. By subjective thermal sensation, subjective humidity sensation, and thermal comfort sensation, it was proved that non-wearing vest decreased comfort than wearing that. These results suggested that wearing ice gel-based cooling vest reduced human heat strain in hot environment both resting and exercising.

  • PDF

열적 쾌적성 증대를 위한 부위별 냉각 효과 비교 (Comparison of Cooling Effects by Body Part to Increase Thermal Comfort)

  • 박소영;이예진
    • 한국의류학회지
    • /
    • 제48권3호
    • /
    • pp.501-510
    • /
    • 2024
  • This study aimed to compare the cooling effect of specific body parts to increase workers' thermal comfort. The parts to be cooled comprised the head and neck; the coolant was a phase change material. The participants were ten men in their 20s of average size according to the 8th Size Korea. The experiment was conducted under the following conditions: 28.0 ± 0.5℃, 60.0 ± 5.0% RH, and 0.2 ± 0.1m/s. The exercise consisted of participants moving for 15 min at a constant speed of 80 BPM; later, a subjective sensation was performed, and the clothing surface temperature was measured. In doing so, heat, wetness, and discomfort after exercise were confirmed to have increased without a coolant. Significant differences over time appeared only when no coolant was used, showing that thermal comfort decreased. Despite the addition of coolant, the clothing surface temperature gradually increased over time, but it decreased with coolant rather than without it. Therefore, additional coolant areas, a lower temperature, and simultaneous cooling convection were required to improve thermal comfort.

냉감소재로 제작한 여성 스포츠 언더웨어의 피트성과 착용시 주관적 평가 (Subjective Wear Test and Fit of Women's Sports Underwear Made of Cool-Touch Fabric)

  • 김소영;이희란;최지영;홍경희
    • 한국지역사회생활과학회지
    • /
    • 제28권4호
    • /
    • pp.505-514
    • /
    • 2017
  • Although studies on the development of cool touch fabrics have been conducted widely, the effects of fitted pattern on enhancing the cooling sensation are insufficient. To investigate the effect of cool-touch fabric and fit of women's sports underwear, 3D and 2D patterns of sleeveless top and sports leggings were constructed. The performance of cool touch was tested by the Qmax value and wear test with nine subjects. Objective fit evaluation was observed by 3D virtual clothing using Clo software. Subjects rated wearing sensation such as 'cooling sensation, fit, wear comfort and preferences of purchase' using Likert's scale in the environmental chamber at $25^{\circ}C$, 45 %RH. The Qmax value of the cool touch fabric was higher than that of the PET fabric, which was well reflected in 'cooling sensation', especially in the case of a tight-fitted 3D pattern. The cooling sensation of the cool-touch fabric was not significantly elevated with 3D tight pattern as long as the size of the 2D pattern was similar to that of 3D pattern. However, the purchase preference was highly correlated with 3D fit and wear comfort.

신체 부위별 냉각허용한계온도에 관한 연구 (Permissible Safety Limits in Local Cooling Focused on the Parts of Human Body)

  • 황경숙;최정화;김경란
    • 한국의류학회지
    • /
    • 제31권1호
    • /
    • pp.119-130
    • /
    • 2007
  • The objects of this study were to investigate responses and peculiarity during local cooling by parts of the human body and to show permissible safety limits without injurious to his health because of excessive cooling when he works hot environments. It were measured rectal temperature, skin temperature, heart rate, total body weight loss, local sweat in back and thigh, clothing microclimate and subjective sensation on 8 subjects and cooling parts were head, neck, chest, abdomen, back, waist, hip, upper arm, forearm, hand, thigh, calf and foot. According to above-mentioned the first experiment, we chose permissible safety limits by parts of the human body for one hour. In the second experiment, it was showed permissible safety limits by parts which examined their safety about health through 4 hours cooling test on 3 subjects. The results are as follows: 1. As a result of the first experiment, we chose permissible safety limits by parts, as follows, head $25^{\circ}C$, neck $20^{\circ}C$, chest $27^{\circ}C$, abdomen $25^{\circ}C$, back $20^{\circ}C$, waist $20^{\circ}C$, upper arm $20^{\circ}C$, forearm $20^{\circ}C$, hand $23^{\circ}C$, thigh $20^{\circ}C$, calf $20^{\circ}C$ and foot $23^{\circ}C$ in $37^{\circ}C$, 50%R.H. environment for 1 hour. 2. As a result of the second experiment, cooling on these safety limits temperatures except chest didn't have a bad effect on health. So it was proved that right permissible safety limits of chest was $28^{\circ}C$. From these results, it has been suggested that skin temperature didn't fall below permissible safety limits when human body was to be cool by parts.

상변화물질 농도변화에 따른 의복내 공기층의 열적 특성 (Thermal Characteristics of the Garment Air-layers by PCM Concentration Changes)

  • 유화숙;임지혜;김은애
    • 한국의류학회지
    • /
    • 제32권6호
    • /
    • pp.991-998
    • /
    • 2008
  • 본 연구는 상변화물질의 농도가 의복내 공기충의 온도변화에 미치는 영향을 연구하고자 하였다. 상변화물질로는 노나데칸을 사용하였으며 농도는 아크릴 바인더 대비 10%, 20%, 30%로 조절하여 면직물에 코팅처리하였다. 동적 열전달 측정장치인 Human-Clothing-Environment Simulator을 사용하여 고온에서 저온 이동시 다시 고온이동시의 의복내 온도변화를 측정하였다. 외부 환경온도는 고온은 34도, 저온은 5도와 10도를 하였으며 먼저 34도에서 한시간 동안 컨디셔닝한 후에 5도 또는 10도에 30분 동안 노출시켜 의복내 온도변화를 측정하였고 다시 34도에 노출시켜 30분동안 의복내 공기층에서의 상변화물질의 열적거동을 살펴보았다. 그 결과 상변화물질처리된 직물로 이루어진 의복내 공기층은 고온에서 저온이동시 상변화물질의 발열효과로 인해 미처리 직물보다 높은 온도를 나타내었으며, 저온에서 고온이동시에는 흡열효과로 인해 미처리 직물보다 온도상승이 느리게 나타났다. 농도가 증가할수록 상변화물질에 의한 발열효과는 증가하는 것으로 나타났으며 흡열효과의 경우에는 20%에서 큰 변화를 갖는 것으로 나타났다. 농도변화에 따른 미처리와 처리직물 사이의 차이를 보면, 10%에서 20% 증가시에 나타난 차이가 20%에서 30% 농도변화시에 나타난 차이보다 크게 나타났다. PCM 처리된 모든 직물들이 상변화를 겪는 것은 아니었으며 직물층에 따라 상변화를 하였고 최외곽층의 경우에는 상변화물질에 의한 흡열발열현상외에도 외부로의 열손실을 겪기 때문에 이에 대한고찰이 있어야하는 것을 알 수 있었다.