• Title/Summary/Keyword: Cooling pad

Search Result 61, Processing Time 0.024 seconds

Analysis of Temperature Gradients in Greenhouse Equipped with Fan and Pad System by CFD Method (CFD 기법을 이용한 팬 앤 패드 냉방 온실의 온도경사 분석)

  • Nam Sang Woon;Giacomelli Gene A.;Kim Kee Sung;Sabeh Nadia
    • Journal of Bio-Environment Control
    • /
    • v.14 no.2
    • /
    • pp.76-82
    • /
    • 2005
  • Evaporative cooling pad system is one of the main cooling methods in greenhouses and its efficiency is very high. However, it has some disadvantages such as greenhouse temperature distributions are not uniform and installation cost is expensive. In this study, a CFD simulation model f3r predicting the air temperature distribution in the fan and fad cooling greenhouse was developed. The model was calibrated and validated against experimental data and a good fit was obtained. The influence of different outside wind, fan and pad height, ventilation rate, shading, and greenhouse length, were then examined. In order to reduce the internal temperature gradients, it is desired that the prevail wind direction and the fan and pad heights are considered. The simulation indicates that high ventilation rates and shading contribute to reduce the temperature gradients in the fan and pad cooling greenhouse. In order to maintain the desired greenhouse temperature, the pad-to-fan distance should be restricted according to the design climate conditions, shading and ventilation rates. The developed CFD model can be a useful tool to evaluate and design the fan and pad systems in the greenhouses with various configurations.

Heating and Cooling Channel Design of Cross-Shaped Die for Warm Forming of Magnesium Alloy Sheet (Mg 온간성형을 위한 십자형상 금형의 가열/냉각 채널 설계)

  • Choi, S.C.;Ko, D.S.;Kim, H.Y.;Kim, H.J.;Hong, S.M.;Ryu, S.Y.;Shin, Y.S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.05a
    • /
    • pp.370-373
    • /
    • 2008
  • It is known that the temperatures of die, punch, holder and punch pad need to be kept different to get better formability in Mg sheet forming processes. Heating and cooling channels are usually equipped in each tool to assign different temperature. This study focused on the optimal design of the heating and cooling channels for a cross-shaped deep drawing die set. While the die and blankholder were heated to and kept at $250^{\circ}C$ by using heat cartridges, the punch and punch pad were kept at much lower temperature than that of the die and blankholder by water circulating through cooling channels. All the approaches were done by numerical analyses, aiming to maximize the cup height and to minimize the punch corner radius without any failure.

  • PDF

Application of CFD Simulation to Cooling System Design of Agricultural Products Processing Center Workplace (농산물산지유통센터 작업장의 냉방 설계를 위한 CFD 시뮬레이션 적용)

  • Kwon, Jin-Kyung;Lee, Sung-Hyun;Moon, Jong-Pil;Lee, Su-Jang;Kim, Keyong-Won
    • Journal of Bio-Environment Control
    • /
    • v.19 no.4
    • /
    • pp.195-202
    • /
    • 2010
  • Cooling air-conditioning of APC (Agricultural Products processing Center) workplace is important to improve the working environment in the summer season. As existing cooling systems for air-conditioning of whole workplace are inefficient because of their high equipment operating costs, relatively inexpensive cooling system is required. The objectives of this study were to simulate the thermal flow fields in APC workplace having the positive and negative pressure type fan and pad systems and spot cooling system by using CFD software (FLUENT, 6.2) and estimate the cooling effectiveness of respective cooling systems. The results showed that the negative pressure type fan and pad system was inappropriate for the present APC workplace because of excessive outside air influx from open gateway and the positive pressure type fan and pad system created relatively low temperature field but non-uniform velocity field at worker positions. The spot cooling system could supply cool air to worker positions with relatively constant air velocity and temperature.

The Effect of Pad Groove Density on CMP Characteristics (패드 그루브의 밀도변화가 연마특성에 미치는 영향)

  • Park Kihyun;Jung Jaewoo;Lee Hyunseop;Seo Heondeok;Jeong Seokhun;Lee Sangjik;Jeong Haedo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.8 s.173
    • /
    • pp.27-33
    • /
    • 2005
  • Polishing pads play an important role in chemical mechanical polishing(CMP) which has recently been recognized at the most effective method to achieve global planarization. In this paper, we have investigated CMP characteristics as a change of groove density of polishing pads. The parameter $(K_n)$ is proposed to estimate groove density of pad. The $K_n$ is defined as groove area divided by pitch area. As the groove density value increased, removal rate increased to some point and then gradually saturated in case of increasing the groove density excessively. In addition Within wafer non-uniformity(WIWNU) worse as groove density increased excessively, although WIWNU improved as groove density increased. Also the uniformity of temperature of pad surface decreased as the groove density increased. It was because that the cooling effect increased as groove density increased. In other words, increasing the groove density which means the apparent contact area of pad has influence on amount of discharge of slurry during polishing process.

The Cooling Characteristics of a Gas Deflector Using Water Spray Cooling System in Launch Pad (물 분사 냉각시스템을 이용한 발사대 화염유도로의 냉각특성)

  • Lee, Kwang-Jin;Chung, Yong-Gahp;Cho, Nam-Kyung;Nam, Jung-Won;Jung, Il-Hyung;Ra, Seung-Ho
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.756-762
    • /
    • 2011
  • A gas deflector cooling system plays an important role in the suppression of shock wave generated during the ignition of a launch vehicle engine. Also, this system decrease a large vibration of damaging the payload and structure of the launch vehicle. The gas deflector cooling system in the launch pad of NARO space center was constructed to directly inject water into the plume of the launch vehicle engine. The flight test result of NARO space launch vehicle showed that this method had a good performance on the viewpoint of cooling the gas deflector.

  • PDF

Effects of Pad Cooling Systems in Tunnel-Ventilated Broiler House on Reducing Indoor Temperature and Level of Temperature-Humidity Index during Summer (국내 터널식환기 무창 육계사에서 여름철 쿨링패드 사용에 따른 계사 내부 온도 저감 효과 및 더위지수(THI)에 미치는 영향)

  • Hye Ran Kim;Seol Hwa Park;Jisoo Wi;Seongshin Lee;Sung Dae Lee;Hwan Ku Kang;Chaehwa Ryu
    • Korean Journal of Poultry Science
    • /
    • v.51 no.2
    • /
    • pp.57-63
    • /
    • 2024
  • As global warming worsens, it is feared that higher ambient temperatures and relative humidity might result in a more intense heat stress for livestock animals, especially broilers, which lack sweat glands for thermoregulation and have been selectively bred for rapid growth. Therefore, strategic livestock management is needed to mitigate the adverse effects of heat stress on broilers. In Korea's poultry farming systems, tunnel-ventilated broiler houses and pad cooling systems are commonly installed to lower indoor temperatures during the summer. However, caution is advised with pad cooling systems as they can increase the humidity inside the houses, potentially causing further harm. This study aimed to evaluate the effectiveness of pad cooling systems in tunnel-ventilated broiler house by assessing the reduction in indoor temperature using the Temperature-Humidity Index (THI), which accounts for the impact of relative humidity. Temperature and humidity data were collected during the summer (Jun to Sep) from eight farms with tunnel-ventilated broiler house located in different regions of Korea. The farms were divided into two groups based on the use of pad cooling systems is used, and temperature and humidity data, along with THI values, were analyzed two weeks before the birds were marketed. Meta-analysis results showed that at the hottest time of the day, 14:00, farms with pad cooling systems had significantly lower indoor temperatures compared to the control group, but observed an increase in indoor temperatures by 16:00 (p<0.05). There is no significant difference in relative humidity (p>0.05). The THI values decreased in the treatment group with cooling pads compared to the control group starting from 15:00, suggesting a diminished effect (p<0.05). This study indicates the potential for developing optimal operational guidelines for cooling pads to reduce heat stress in broilers during the summer season.

DEVELOPMENT OF NIGHT COOLING SYSTEM FOR GREENHOUSE USING COOL AIR AND WATER FROM AN ABANDONED COAL MINE

  • Whoa S. Kang;Wie S. Kang;Lee, Gwi H.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.1136-1145
    • /
    • 1996
  • This study was to develop the most effective cooling system which is needed to cool greenhouse during summer night to get early blooming of strawberries. Various cooling systems were designed and constructed to utilize the cool air and water from tan abandoned coal mine. Cooling systems built for this study were an evaporative cooling system with pad, cooling system using a small or large radiator , and duct cooling system using cool are drawn from coal mine. These systems were individual tested to investigate their effects on cooling greenhouse during summer night. Also, a combined cooling system was tested with operating an evaporative cooling system, small radiator, and duct cooling system simultaneously. The results in this study showed that individual cooling systems such as evaporative cooling system, small radiator, and cooling duct had about the same effect on cooling greenhouse. The combined system had little better cooling effect than that of individual cooling syst m except the large radiator . The most effective system for cooling of greenhouse was obtained with using a large a large radiator as the heat exchanger. With operating a large radiator, temperature inside the greenhouse was dropped to about 15-16$^{\circ}C$ while outside temperature was 23-24$^{\circ}C$ during summer night.

  • PDF

Numerical Prediction of Brake Fluid Temperature Considering Materials of Piston During Braking (제동시 피스톤 소재를 고려한 브레이크 오일 온도의 수치적 예측)

  • 김수태;김진한;김주신
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.445-450
    • /
    • 2004
  • Recently, many studies have been performed and good results have been reported in literature on the prediction of the brake disk temperature. However, study on the brake fluid temperature is rarely found despite of its importance. In this study, brake fluid temperature is predicted according to material property of brake piston. For the analysis, a typical disk-pad brake system is modeled including the brake disk, pad, caliper, piston and brake fluid. Vehicle deceleration, weight distribution by deceleration, disc-pad heat division and the cooling of brake components are considered in the analysis of heat transfer. Unsteady-state temperature distribution are analyzed by using the finite element method and numerical results are compared with the vehicle test data

  • PDF

A study on development of the standard PAD-mounted type Transformer (표준형 지상변압기 개발에 관한 연구)

  • 조국희;김광화;양태권;홍원식;조양섭;김양태
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1997.10a
    • /
    • pp.74-77
    • /
    • 1997
  • As underground distribution systems to be operated in downtown have more merits than overhead distribution system, underground distribution systems are being increased. But when pad-mounted transformers have troubles, reptures and fires can be occurred. We think that this makes accidents and power failures of bulidings and generates malaise and a great economic loss. In order to increase the reliability of pad-mounted transformers, we have investigated transformers and understood their failure mechani는. Therefore, we would have objectives and necessities of this study to improve quality and operating condition and install switches to be able to check and maintain transformers and optimize protection devices and increase cooling effect in pad-mounted transformers.

  • PDF

A Fundamental Study on the Green House Cooling by Water-Flow Air Conditioner in Summer Season (지하수 관류 냉방기를 이용한 여름철 온실냉방 기초연구)

  • 박권우;서명훈;이수연;유창재;이광선
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1994.11a
    • /
    • pp.67-69
    • /
    • 1994
  • 4계절이 뚜렷한 우리나라의 겨울철은 작물생산에 단경기이었으나, 플라스틱 하우스나 유리온실이 보급되면서 겨울철 단경기가 해소되었다. 그러나 이리한 시설들은 PE 또는 유리 등의 피복자재를 사용하여 여름철의 경우 막대한 일사부하로 온실 내부온도가 외부온도보다 높아져 작물생육에 열악한 환경을 조성한다. 이에 fog and pad system, fan and pad system 과 heat pump 등이 개발되어 있으나 실용적으로 도입되지 못하고 있는 실정이다. (중략)

  • PDF