• 제목/요약/키워드: Cooling methode

검색결과 7건 처리시간 0.027초

소방로봇 냉각시스템의 최적화를 위한 수치해석 (Numerical optimization studies of a fire fighting robot cooling system)

  • 임중연;유명열;김종권;이현근;김준석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.690-694
    • /
    • 2008
  • In this presentation, we study numerically an optimization problem of a fire fighting robot cooling system. The governing equation for the system is the unsteady heat equation with source term. We use a multigrid method for numerical solutions in three-dimensional space. We investigated the effects of various parameters and the results will be presented.

  • PDF

흡수식 냉온수기의 부분부하에 따른 냉각수 변유량시 성능특성에 관한 연구 (A Study on the Performance Characteristics of an Absorption Chiller for Variable Cooling Water Flow Rate at Partial Load Conditions)

  • 박찬우;조현철;강용태
    • 설비공학논문집
    • /
    • 제16권1호
    • /
    • pp.26-33
    • /
    • 2004
  • In general, an absorption chiller or heat pump is operated under the constant cooling water flow rate condition even though the system works with a partial load. The objective of this paper is to study the effect of the cooling water flow rates and the temperature of cooling water on the system performance to find the energy saving methode for the partial load operation of the double effect $H_2O$/LiBr absorption chiller. It is found that the performance of the system is sensitive to the temperature of cooling water than the cooling water flow rate, so the decrease of the performance due to reducing the cooling water flow rate can be overcome with the reduction of the cooling water temperature by 1$^{\circ}C$. The flow rate of the cooling water flow rate ranges from 50% to 100% of the flow rate at normal conditions with a partial load. It is also found that the operation cost of the cooling water pump and the cooling tower can be reduced by 23%.

전동기 냉각팬의 유량예측을 위한 수치해석 (A Numerical Analysis for Prediction of Flow Rate of the Motor Cooling Fan)

  • 이상환;강태인;안철오;서인수;이창준
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.670-677
    • /
    • 2005
  • In this study, we analyzed the three dimensional unsteady flow field around the motor cooling fan using the unsteady lifting surface theory. We obtained the flow rate for various geometries of fan from the calculated results of velocity field. For the data of design parameter and rotating speed(rpm) of the fan, we can predict the flow rate of the motor cooling fan with thin thickness through numerical analysis without the experimental data of the free stream velocity which is a boundary condition of flow field. the numerical results showed the flow rate within 10% of error in comparison with experimental results. The radial fans, which are often used as internal motor fan were also investigated with the same procedure.

  • PDF

교류 코로나 방전시 주파수 변화에 따른 전기유체역학적 특성 (Electrohydrodynamic Characteristics of AC Corona Discharge for the Frequency)

  • 정재승;김진규
    • 조명전기설비학회논문지
    • /
    • 제26권12호
    • /
    • pp.87-92
    • /
    • 2012
  • In this paper, EHD(electrohydrodynamics) characteristics of AC corona discharge for the various frequency was investigated. Ionic wind velocity is controlled by the frequency of applied ac high voltage, and maximum velocity of the ionic wind is obtained at 1.2kHz. Maximum velocity are 1.90 m/s by metal corona electrode and 2.72m/s by wet porous corona electrode, These attain 91~99% of the maximum velocity in the DC corona discharge by adjusting the frequency through the experiments. In this paper, wet porous corona electrode has high possibility of cooling methode because a AC corona discharge using wet porous corona electrode is able to eject more water droplets than DC corona discharge.

틸팅열차 실내 쾌적성 향상 연구 (Study to improvement of the interior comfort in the Tilting train)

  • 김현식;장창윤;장재승
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1243-1248
    • /
    • 2009
  • This paper introduces the methode to improve the indoor air quality for Korea Tilting train express(TTX). TTX operates more than 80,000km in commercial line and in the near future service is expected. To improve air quality effective heat and cooling system is proposed. Also according to the ministry of environment guide line, major factor component are selected to Co2(carbon dioxide) and Pm10(particle matter). The database of the vital factor was accumulated by the various case of operation environment. Finally, optimal air condition controling device is developed and installed.

  • PDF

공기 유동에 따른 Ni-MH 배터리 모듈의 효과적인 냉각에 관한 연구 (Study for Effective Cooling of Ni-MH Battery Module Using Forced Air Flow)

  • 안치영;김태신;김준범
    • 전기화학회지
    • /
    • 제14권4호
    • /
    • pp.253-260
    • /
    • 2011
  • 본 연구에서는 10개의 배터리로 구성된 모듈에 대한 열관리 전산모사를 수행하였다. 배터리의 구조를 단순화 하였고, 전기저항 등가식을 이용한 열전도 이론을 사용하였다. 2.6 mm의 좁은 배터리 사이의 간격에 대한 격자의 신뢰도 검증 실험을 진행하였고, 그 결과 배터리 사이에 최소 3개 이상 나누어진 격자의 형태가 필요하였다. 크게 모듈의 후면에서 공기가 유입되는 형태, 모듈의 상부에서 공기가 유입되는 형태 그리고 모듈의 하부에 공기가 유입되는 형태로 나누어 팬과 공기흡입구의 위치에 따른 모듈의 효과적인 냉각방법을 모색하였다. 배터리의 성능에 영향을 미치는 모듈의 최고온도와 배터리간의 온도 차이를 비교하였고, 공기의 유속을 비교하여 유체의 거동을 확인하였다. 모듈의 하부에서 공기가 유입되는 경우, $40.27^{\circ}C$로 가장 낮은 최고온도를 보였고, 모듈의 상부에서 공기가 유입되는 경우에 $0.73^{\circ}C$로 가장 적은 온도편차를 보였다.

전면발광 유기광소자용 박막 봉지를 위한 유도결합형 화학 기상 증착 장치 (Inductively Coupled Plasma Chemical Vapor Deposition System for Thin Film Ppassivation of Top Emitting Organic Light Emitting Diodes)

  • 김한기
    • 한국전기전자재료학회논문지
    • /
    • 제19권6호
    • /
    • pp.538-546
    • /
    • 2006
  • We report on characteristics of specially designed inductively-coupled-plasma chemical vapor deposition (ICP-CVD) system for top-emitting organic light emitting diodes (TOLEDs). Using high-density plasma on the order of $10^{11}$ electrons/$cm^3$ generated by linear-type antennas connected in parallel and specially designed substrate cooling system, a 100 nm-thick transparent $SiN_{x}$ passivation layer was deposited on thin Mg-Ag cathode layer at substrate temperature below $50\;^{\circ}C$ without a noticeable plasma damage. In addition, substrate-mask chucking system equipped with a mechanical mask aligner enabled us to pattern the $SiN_x$ passivation layer without conventional lithography processes. Even at low substrate temperature, a $SiN_x$ passivation layer prepared by ICP-CVD shows a good moisture resistance and transparency of $5{\times}10^{-3}g/m^2/day$ and 92 %, respectively. This indicates that the ICP-CVD system is a promising methode to substitute conventional plasma enhanced CVD (PECVD) in thin film passivation process.