• 제목/요약/키워드: Cooling impact

검색결과 274건 처리시간 0.026초

대구의 여름철 야간 냉각량과 기상요소와의 관련성 연구 (A Study on the Relationship between the Summertime Night Cooling Rate and Meteorological Elements in Daegu)

  • 김하영;김해동
    • 한국환경과학회지
    • /
    • 제30권10호
    • /
    • pp.821-831
    • /
    • 2021
  • The relationship between night cooling rate and meteorological elements was investigated over the past five years (2016-2020), using weather data from the new (Daegu(143)) and old (Shinam(860)) Daegu Regional Meteorological Agency located in the suburban and urban regions, respectively. There was a correlation between the total daily amount of solar radiation (Stot) and the night cooling rate in the both regions. However, a higher correlation was observed at the new Daegu Regional Meteorological Agency station (Daegu(143)). In particular, data from the new Daegu Regional Meteorological Administration's observatory, which experiences a low thermal storage effect caused by artificial structures, showed a higher correlation between nighttime cooling and weather factors. The reason for this is that the lesser the heat storage effect caused by the artificial structures, the better the effect of surface radiation cooling on temperature reduction. These findings confirm that the correlation between night cooling and weather factors can be used to assess the impact of artificial structures in cities.

SAF 2205 듀플렉스 스테인레스강의 미세조직 및 기계적 특성에 미치는 냉각속도의 영향 (Effect of Cooling Rate on Microstructural and Mechanical Properties of SAF 2205 Duplex Stainless Steel)

  • 오영주;양원존;이종훈;김두현;유위도;이재현
    • 열처리공학회지
    • /
    • 제26권1호
    • /
    • pp.14-20
    • /
    • 2013
  • Duplex stainless steel, which is a kind of stainless steel with a mixed microstructure of about equal proportions of austenite and ferrite, is generally known as a unique material with excellent corrosion resistance and high strength. However, toughness, strength, and corrosion resistance of the steel could be reduced due to precipitation of topologically closed packed phases such as sigma phase during cooling. In case of large forged products, they have strong possibility that ${\sigma}$-phase precipitates due to difference of cooling rate between surface and inner of the products. Investigation on sigma phase precipitation behavior of duplex stainless steel with change of cooling rate was carried out in this study. Forged SAF 2205 duplex stainless steel was used as specimens to examine the cooling rate effect. Dissolution behavior of sigma phase was also discussed through resolution test of duplex stainless steel containing lots of sigma phase. Experimental results revealed that impact energy was very sensitive to precipitation of small amount sigma phase. However, sigma phase could be removed by short term resolution treatment and impact resistance of the duplex stainless steel was restored.

고강도 엔진밸브 스프링강 선재 저온조직 발생방지 선재압연 기술 (Controlled Cooling Technical of High Tensile Valve Spring Wire Rod)

  • 김경원;장용권;임규환;서일권
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1999년도 제3회 압연심포지엄 논문집 압연기술의 미래개척 (Exploitation of Future Rolling Technologies)
    • /
    • pp.172-179
    • /
    • 1999
  • As the martensite structure cause fracture failure during drawing from 5.5mm rod to 3.05mm dia. wire without additional heat treatment, the optium cooling condition to inhibit the occurrence of martensite was investigated. In order to get SAE9254+V quality, the effects of alloying element, vanadium on the mechanical properties were investigated. Based upon CCT and TTT curves and the results form cooling test in mill, optimun cooling was found in the condition of the laying head temp of 780$^{\circ}C$ and of the conveyor speed at 0.15m/sec with the whole cover closed. The wire rods produced under the condition showed the best mechanical properties of 120kg/$\textrm{mm}^2$ in TS and 50% in RA, having an excellent drawability. In vanadium added steels, tensile strength was improved without degrading elongation and charpy impact value. That means the strengthening by vanadium is mainly due to the grain refinement by the fine precipitates during tempering process.

  • PDF

4kW급 상용차량용 전력전자 냉방장치의 열 환경 성능평가 (Thermal environmental performance evaluation of 4kW power electronic cooling system for commercial vehicle)

  • 한근우;김성곤;이충훈;최명현;정영국
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.290-291
    • /
    • 2017
  • This study deals with an evaluation method for testing the robustness of the 4 kW commercial power electronic cooling system to the thermal environment. The power electronic cooling system consists of a cascaded push-pull DC / DC converter, a three-phase DC / AC inverter, and an electric compressor. The system manufactured by the thermal environment evaluation test (heat distribution test, thermal impact test, high temperature operation test, temperature cycle test, low temperature operation test) for the commercial electric power cooling system for commercial vehicle proves that it is robust against thermal environment.

  • PDF

고온 초전도 SMES용 전도냉각시스템 특성시험 (Test of the Conduction Cooling System for HTS SMES)

  • 염한길
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권1호
    • /
    • pp.62-66
    • /
    • 2008
  • The characteristic of the superconducting magnetic energy storage(SMES) system is faster response, longer life time, more economical, and environment friendly than other uninterruptible power supply(UPS) using battery. So, the SMES system can be used to develop methods for improving power quality where a short interruption of power could lead to a long and costly shutdown. Recently, cryogen free SMES has developed using BSCCO(Bismuth Strontium Calcium Copper Oxide) wire. We fabricated and tested the conduction cooling system for the 600 kJ class HTS SMES. The experiment was accomplished for the simulation coils. The simulation coils were made of aluminium, it is equivalent to thermal mass of 600 kJ HTS SMES coil. The coil is cooled with two GM coolers through the copper conduction bar. In this paper, we report that the test results of cool-down and heat loads characteristics of the simulation coils. The developed conduction cooling system adapted to 600 kJ HTS SMES system and cope with the unexpected sudden heat impact, too.

GCD 50의 ADI처리시 기계적 성질에 미치는 퀜칭 매질의 영향 (Effect of Quenching Medium on the Mechanical Properties of ADI Treated GCD 50)

  • 김한군;오이식;김헌주;신기근
    • 열처리공학회지
    • /
    • 제21권3호
    • /
    • pp.137-143
    • /
    • 2008
  • Effect of quenching medium on the mechanical properties of ductil iron GCD 50 has been investigated using ADI treated specimens. The specimens have been austenitized at $900^{\circ}C$ for 2 hours, followed by controlled cooling to $800^{\circ}C$ under the cooling rate of $0.05^{\circ}C/sec$, then austempered at $380^{\circ}C$, $330^{\circ}C$, $280^{\circ}C$ and $230^{\circ}C$ for 1 hour. The specimens treated in the salt of 5% water were found to have higher tensile strength than that of the normal salt bath. Elongation and impact energy increased in proportion to the increase of retained austenite volume fraction. The increase of cooling rate of the salt by the addition of 5% water to the salt resulted in the increase of retained austenite volume fraction and the formation of fine bainitic ferrite.

강화된 건물 외피 단열기준의 지역별 냉난방에너지 감소 효과 (Impact of Reinforced Standard for Envelope Insulation on the Regional Heating and Cooling Energy Consumption)

  • 문진우
    • 설비공학논문집
    • /
    • 제23권10호
    • /
    • pp.646-655
    • /
    • 2011
  • This study aimed at quantifying the impact of the reinforced standard for envelope insulation on heating and cooling energy consumption in a Korean detached house as well as at identifying the effect of regionally subdivided standards. For them, a series of simulations for application of the reinforced standard on respective walls, roof, floor, windows, and all envelopes were computationally conducted for a prototypical detached residential building. In addition, the subdivided standards were applied to each regions-central and southern regions, and the Jeju island. Analysis revealed that heat transfer through envelopes was the most significant source of building heat gain and loss; the reinforced standard effectively reduced heating energy consumptions, especially in central region; and the subdivided standards did not presented a clear difference in the amount of energy consumption for the southern region and the Jeju island, thus, a further study is required to investigate the necessity of regional subdivisions.

V첨가 0.35%C-Mn 미소합금강의 연속공기냉각특성 (The Characteristics of Continuous Air Cooling in 0.35%C-Mn Steel Microalloyed with Vanadium)

  • 심재진;이상윤
    • 열처리공학회지
    • /
    • 제4권3호
    • /
    • pp.39-46
    • /
    • 1991
  • The effects of austenitizing temperatures and times and cooling rate on the characteristics of continuous air cooling have been investigated for 0.3%C-Mn steels microalloyed with vanadium. Transformation start temperatures have been found to be measured from temperature-time curve directly obtained with continuous air cooling and to decrease with increasing austenitizing temperature, cooling rate and Mn contents. The coarsening behavior of austenite grain size has been measured to abnormally grow at $1050^{\circ}C$ and rapidly grow at $1200^{\circ}C$. It has been found that the volume fraction of pearlite was linealy proportional to the reciprocal square root of austenite grain size. The hardness has been measured to increase with increasing cooling rate up to $250^{\circ}C/min.$ and to remain relatively unchanged in the range of $250{\sim}400^{\circ}C/min.$ showing that hardness valves for steel with a higher Mn content increase more than those for steel with a lower Mn content. The impact property has been found to decrease with increasing of austenite grain size but does not linealy change with the reciprocal square root of austenite grain size.

  • PDF

지역의 경관을 고려한 도막방수재의 색채별 사계절 차열 및 축열 성능에 관한 연구 (A Study on the Four-Season Cooling Performance by Color of Water Proofing Membrane Materials Considering the View of Area)

  • 고진수;김병윤
    • 한국농촌건축학회논문집
    • /
    • 제17권2호
    • /
    • pp.9-16
    • /
    • 2015
  • This study comparatively analyzed thermal characteristics of the green color, which is currently used the most, and other various colors of a rooftop urethane water proofing sheet. This study also analyzed the cooling performance by color of the water proofing sheet that fused cooling paints, and presented the effective water proofing sheet color for building energy savings. The experimental results are as follows: (1) The value of L (brightness) diminished, and brilliance also became lower from the white color to the black color, and thus, it was confirmed that relatively more heat was absorbed. In a and b chromaticity, which is the color attribute that ignores brightness, no special relationship was identified. (2) Considering that the cooling performance effect is bigger in summer than winter, due to heat reflection, the white water proofing sheet is more effective in building energy savings than the green water proofing sheet that is currently used the most. (3) The water proofing sheet's color has an impact more on cooling performance than the color of the background side of a structure on which water proofing sheet is installed. The experiment object of gray, of which background side is similar to cement mortar, was lower by $5.7^{\circ}C$ than the white background side.

국내 공동주택의 에너지절약 설계기준 강화에 따른 냉난방설비 설계 기준 개선 방안 (Improvement of Design Criteria in Heating and Cooling Equipment According to the Consolidation of Design Standard for Energy Saving in Apartment Buildings of Korea)

  • 임재한;김성임;송승영
    • 한국태양에너지학회 논문집
    • /
    • 제34권3호
    • /
    • pp.89-97
    • /
    • 2014
  • Recently design standard for energy-saving in apartment buildings has been consolidated gradually on the basis of evaluation and certification standards of energy efficiency of buildings, the energy-saving policy of building at home and abroad. Performance criteria for thennal insulation as well as fenestration has been progressively enhanced, and performance criteria for ventilation and airtightness of the building have also been re-developed. Therefore, heating and cooling load characteristics of the apartment building can be changed. For the design of the upcoming heating and cooling equipment in apartment buildings, it is necessary to evaluate the heating and cooling load characteristics according to the design strategies for energy saving in apartment buildings. As a result, in this study, it is intended to use as a resource for analyzing the impact that the adoption of energy-saving design variables for each of the apartment buildings, to predict the heating and cooling load characteristics in the apartment building.