• Title/Summary/Keyword: Cooling garment

Search Result 10, Processing Time 0.022 seconds

Development of Cooling Garment for Extremely Hot Environment Using a Peltier Device and its Comfort Properties (고온환경 작업을 위한 펠티어 소자 냉각복 개발 및 쾌적성 평가)

  • Jung, Ye-Lee;Chae, Young-Jin;Kim, Eun-Ae
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.36 no.1
    • /
    • pp.1-11
    • /
    • 2012
  • This paper reports on a prototype cooling garment applying a cooling module. The cooling module was composed of a Peltier device, a cold sink, a heat sink and two fans. A constant box was used to evaluate the cooling effect of the module. Two cooling modules were attached on each side of the garment. The wear trial was conducted using 10 male subjects in an environmental chamber maintained at $30{\pm}0.5^{\circ}C$, $50{\pm}5%$RH. Subjective sensations of thermal, humidity, and comfort were surveyed. Statistical package SPSS12.0 was used for the t-test and the Wilcoxon signed-rank test. The results showed that most effective cooling module decreased the temperature of the constant temperature box by $-4.9^{\circ}C$. The micro-temperature of the cooling garment with a Peltier device was lower than the control garment during the exercise. In particular, the chest skin temperature was $1.5^{\circ}C$ lower with the cooling garment than the control. The maximum temperature difference was $-2.57^{\circ}C$ on the sides of the $1^{st}$ layer. Subjective thermal sensation from wear trials of the Peltier device attached garment was lower than the control garment. Subjects felt more comfortable with the cooling garment in almost all the periods.

Developing Liquid Cooling Garments to Alleviate Heat Strain of Workers in Summer and Exploring Effective Cooling Temperature and Body Regions (여름철 작업자들의 고체온증 예방을 위한 액체냉각복 개발 및 효과적인 냉각온도와 인체 냉각부위 탐색)

  • Jung, Jae-Yeon;Kang, Juho;Seol, Seonhong;Lee, Joo-Young
    • Fashion & Textile Research Journal
    • /
    • v.22 no.2
    • /
    • pp.250-260
    • /
    • 2020
  • The purpose of the present study was to explore the most effective body region and cooling temperature to alleviate heat strain of workers in hot environments. We developed liquid cooling hood, vest, sleeves and socks and applied the water temperatures of 10, 15, 20, and 25℃ through the liquid cooling garments in a hot and humid environment (33℃ air temperature and 70% RH air humidity). A healthy young male participated in a total of 16 experimental trials (four cooling garments × four cooling temperatures) with the following protocol: 10-min rest, 40-min exercise on a treadmill and 10-min recovery. The results showed that rectal temperature, mean skin temperature, and ratings of perceived exertion during exercise; heart rate and diastolic blood pressure during recovery; and total sweat rate were lower for the vest condition than other garment conditions(p < .05). However, there was no differences in mean skin temperature among the four cooling garments when we compared the values converted by covering area(%BSA). When we classified the results by cooling temperature, there were no consistent differences in thermoregulatory and cardiovascular responses among the four temperatures, but 25℃ water temperature was evaluated as being the most ineffective cooling temperature in terms of subjective responses. In conclusion, the results indicated that wearing cooling vest with < 20℃ cooling temperature can alleviate heat strain of workers in hot and humid environments. If the peripheral body regions are cooled with liquid cooling garments, larger cooling area with lower cooling temperature than 10℃ would be effective to reduce heat strain of workers. Further studies with a vaild number of subjects are required.

Thermal Characteristics of the Garment Air-layers by PCM Concentration Changes (상변화물질 농도변화에 따른 의복내 공기층의 열적 특성)

  • Yoo, Hwa-Sook;Lim, Ji-Hye;Kim, Eun-Ae
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.6
    • /
    • pp.991-998
    • /
    • 2008
  • This study is to determine the effects of PCM concentration on the temperature changes of the air layers of a garment when the environmental temperature changes. The selected PCM was Nonadecane and coated on cotton fabrics with PCM concentrations 10%, 20%, and 30%. The temperature changes of the air layers between fabrics were measured by Human-Clothing-Environment Simulator which measure a dynamic heat transfer. After stabilizing at $34^{\circ}C$ for 1 hour, the multi layered garment system were exposed to $5^{\circ}C$ or $10^{\circ}C$ for 30 minutes and then, exposed to $34^{\circ}C$ for 30minutes. The results like following could be obtained. When the environmental temperature changed high to low, temperature of the air layer increased by heating effect of PCM. In the contrast, when the environmental temperature changed low to high, the temperature increase of the air layer was delayed because of cooling effect by PCM. Also, the more concentration of PCM, the bigger the heating effect. Cooling effect showed more clearly at PCM concentration 20%. The temperature differences of the air layers between with PCM fabrics and with non-PCM fabrics were bigger at $10^{\circ}C$ than at $5^{\circ}C$. Consequently, though PCM has influenced on the temperature of the air layer by heating and cooling effect, those effects haven't shown in all layers equally. It was shown that the effect of PCM varied according to the layer in the case of multi layered garment system and heat gain as well as heat loss in the outermost layer had to be taken into account.

Thermophysiological Response of Human Body in Wearing Codling Vest (냉각조끼착용에 따른 인체의 온열생리학적 특성)

  • 권오경;김태규
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2000.11a
    • /
    • pp.148-154
    • /
    • 2000
  • To do this study, we produced cooling vest newly. Rectal temperature was ascended approximately from 37.2$^{\circ}C$ to 38.05$^{\circ}C$ in lab, but wearing cooling vest, the temperature was descended 0.2 while wearing developed product compare with existing product. Mean skin temperature which was showed distribution from 32.8∼36.5$^{\circ}C$, it was descended 1.0∼1.1$^{\circ}C$, while wearing cooling vest and comparing with existing product, wearing developed product was lower 0.5$^{\circ}C$, While wearing developed product, it was found that they had lower tendency than exiting product. Specifically in case of temperature within clothing(chest) 0.2∼2.0$^{\circ}C$ in case of humidity within clothing 2∼8% RH. Facts from above we confirmed that clothing microclimate had been improved and space was happened between body and garment in order to control. In subjective sensation, existing product made negative response during experiment period from participants, but developed product was nearing to comfortable area.

  • PDF

Efficacy of Cooling Vest for Auxiliary Body Cooling in Hot Environments(2) - Comparison in Terms of Thermophysiological Properties Between New Cooling Vest and Standard Cooling Vest - (고온환경 하에서 착용하는 인체냉각 보조도구로서의 Cooling Vest연구(2) - 개발제품의 온열생리학적특성 -)

  • Kwon, Oh-Kyung;Kim, Tae-Kyo;Kim, Jin-A
    • Fashion & Textile Research Journal
    • /
    • v.2 no.4
    • /
    • pp.346-352
    • /
    • 2000
  • The purposes of this study are finding out thermophysiological properties throughout wearing experiment with standard cooling vest as well as providing data in order to design and apply more comfortable cooling vest. To do this study, we produced cooling vest newly. 1. Rectal temperature was ascended approximately from $37.2^{\circ}C$ to $38.05^{\circ}C$ in lab, but wearing cooling vest, the temperature was descended 0.2 while wearing developed product compare with existing product. Mean skin temperature which was showed distribution from $32.8{\sim}36.5^{\circ}C$, it was descended $1.0{\sim}1.1^{\circ}C$, while wearing cooling vest and comparing with existing product, wearing developed product was lower $0.5^{\circ}C$. 2. While wearing developed cooling vest, it was found that they had lower tendency than standard cooling vest. Specifically in case of temperature within clothing (chest) $0.2{\sim}2.0^{\circ}C$ in case of humidity within clothing 2~8%RH. Facts from above we confirmed that clothing microclimate had been improved and space was happened between body and garment in order to control. 3. In subjective sensation, standard cooling vest made negative response during experiment period from participants, but new cooling vest was nearing to comfortable area. It was con finned from above conclusions that wearing developed product is more effective in terms of comfort and reduction of heat stress in situation of working in hot environment.

  • PDF

Thermo-sensitive Clothing Development by Consumer Investigation and Wearing Test (소비자 조사와 착의 실험을 통한 온도감응형 기능성 의류개발을 위한 기초연구)

  • Sang, Jeong-Seon;Chung, Kyunghwa;Park, Juhyun;Oh, Kyung Wha
    • Fashion & Textile Research Journal
    • /
    • v.19 no.1
    • /
    • pp.90-100
    • /
    • 2017
  • In this research, consumer awareness investigation and wearing test were carried out for obtaining useful data on the development of thermo-sensitive functional clothing material. A survey involved 216 people in Seoul and Kyeonggi-do, and 200 questionnaires data were analyzed by descriptive statistics and frequency using SPSS 17.0. Four healthy men in twenties were participated for wearing test. Subjects in normal loungewear were exposed to temperature change from the initial temperature $30^{\circ}C$ down to $5^{\circ}C$ for an hour in a climate chamber. The environmental temperature, surface temperature of garment and skin were measured. As a result, most of respondents have all season clothing products such as underwear, hosiery, and jogging suit for loungewear. Also, thermo regulator y functional clothes are frequently used as underwear and sweat shirt. The consumer awareness investigation on thermo regulatory functional clothing showed that the most important key buying factor is quick climate temperature response, easy maintenance, design and cost, in that order. Surface temperature of garment went down with the cooling down of environmental temperature. The lower environmental temperature, the greater temperature difference by body part showed. Skin temperature change by environmental temperature showed similar tendency of garment surface temperature. In comparison between garment surface and body skin, temperature difference became larger under the lower environmental temperature.

Analysis of Cross Sectional Ease Values for Fit Analysis from 3D Body Scan Data Taken in Working Positions

  • Nam, Jin-Hee;Branson, Donna H.;Ashdown, Susan P.;Cao, Huantian;Carnrite, Erica
    • International Journal of Human Ecology
    • /
    • v.12 no.1
    • /
    • pp.87-99
    • /
    • 2011
  • Purpose- The purpose of this study was to compare the fit of two prototype liquid cooled vests using a 3D body scanner and accompanying software. The objectives of this study were to obtain quantitative measurements of ease values, and to use these data to evaluate the fit of two cooling vests in active positions and to develop methodological protocol to resolve alignment issues between the scans using software designed for the alignment of 3D objects. Design/methodology/approach- Garment treatments and body positions were two independent variables with three levels each. Quantitative dataset were dependent variables, and were manipulated in 3x3 factorial designs with repeated measures. Scan images from eight subjects were used and ease values were obtained to compare the fit. Two different types of analyses were conducted in order to compare the fit using t-test; those were radial mean distance value analysis and radial distance distribution rate analysis. Findings- Overall prototype II achieved a closer fit than prototype I with both analyses. These were consistent results with findings from a previous study that used a different approach for evaluation. Research limitations/implications- The main findings can be used as practical feedback for prototype modification/selection in the design process, making use of 3D body scanner as an evaluation tool. Originality/value- Methodological protocols that were devised to eliminate potential sources of errors can contribute to application of data from 3D body scanners.

Survey on Clothing Worn by Middle-aged Women Undergoing Menopause and Their Satisfaction with Garments According to Menopausal Symptoms (폐경기 증상 경험 유무에 따른 중년여성의 의복 구매 요인 및 만족도 조사)

  • Park, Soonjee;Kim, Hyejin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.36 no.11
    • /
    • pp.1186-1196
    • /
    • 2012
  • This study investigated the garments of middle-aged women undergoing menopause and their satisfaction with them. Data were collected through a survey of 288 middle-aged women and analyzed using SPSS 17.0. As a result (in terms of degree of symptoms) backache, arthralgia, muscular pain and heat sensation were indicated as significantly more outstanding in the menopause group rather than the menopausal transition group. As a countermeasure to physiological symptoms, a change of temperature (warming or cooling) was applied for backache and arthralgia as well as taking medicine for stomachaches and muscular pain. Body parts suffering from heat sensations were the face, back neck, chest center, waist and hip. Body parts suffering from arthralgia and muscular pain were the shoulder and hip joints. The most significant purchasing factor for menopausal women was the fit of outerwear and antibiosis in underwear; however, women not undergoing menopause selected comfortableness when moving as the most important factor. In terms of body shaping and thermoregulation function, the satisfaction degree in underwear was significantly different between the two groups. Menopausal women wanted functional underwear that provided functions such as thermoregulation, absorption of secretions, and antibiosis.

Development of Smart Switchgear for Versatile Ventilation Garments: Optimum Diameter and Voltage Application Unit Time of One-way Shape Memory Alloy Wire for a Bi-directional Actuator (가변 통기성 의복을 위한 스마트 개폐장치 개발: 양방향 작동 액추에이터 제작을 위한 일방향 형상기억합금 와이어의 최적 직경 및 전압인가 단위시간의 도출)

  • Kim, Sanggu;Kim, Minsung;Yoo, Shinjung
    • Science of Emotion and Sensibility
    • /
    • v.21 no.2
    • /
    • pp.137-144
    • /
    • 2018
  • The study figured out the operational conditions of a two-way movement actuator made of one-way shape memory alloy (OWSMA) for versatile ventilation intelligent garments. To develop a low-power actuator that consumes energy only when a garment changes its form such as opening and closing, multiple channels of OWSMA were used, and optimum diameter of the wires was examined. For the switch device, optimum voltage application unit time was determined. Optimum diameter of OWSMA wire was determined by applying 3.7V to the pre-determined candidate diameters, which demonstrated two-way operation in previous studies. In order to evaluate the optimum voltage application time, the internal diameter of the actuator was measured while increasing and decreasing by 50 ms from the unit time of voltage application. Delay time under two-way operation of the actuator was measured to minimize interference caused by heat between channels. Power of 3.7V was applied to OWSMA for assessment of optimal time, and the whole process from heating to cooling was video-recorded with a thermal image camera to determine the point of time at which the temperature of OWSMA wire dropped below the phase transformation temperature. The results showed that $0.4{\Phi}$ was the most suitable diameter, and the optimum unit time of voltage applied to open and close the actuator was 4100ms. It was also shown that the delay time should be more than 1.8 seconds between two-way operations of the actuator.