A Study on the Electronically Controlled Cooling system for Bimodal Tram (바이 모달 트램의 전기 제어 장치용 냉각장치에 관한 연구)

  • Kim, Chang-Uk;Kim, Hea-Soo;Song, Jung-Il
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.4
    • /
    • pp.91-98
    • /
    • 2014
  • In this study, the first and second electronically controlled cooling systems for a bimodal tram were developed. The performance characteristics of the cooling systems were assessed experimentally with actual and identical conditions, and a simulation was run using ANSYS Fluent. The results of the experimental and FEA method were standardized. In order to confirm the reliability of the experimental method, the experiment was carried out by a testing institution. The low-volume flow-rate condition was found to be better, but the cooling system performed in a minimal condition. Therefore, it is important to find the optimum performance levels. The cooling system equipment was revised to determine the optimized design parameters, after which the cooling performance levels increased at the radiation area. Specifically, with a greater fan diameter. Through this study, the newly developed cooling system will be reevaluated after being mounted on an actual bimodal tram. This will lead to a completely domestically produced bi-modal tram cooling system.

A Study on Alternative Fan Selection and Verification in Military Electronic Equipment (방산용 전자장비의 팬 선정 및 검증에 관한 연구)

  • Jin, Sung Eun;Kim, Hwan Gu;Yoon, Eui Youl;Jeon, Hee Ho;Kim, Seung Jun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.11
    • /
    • pp.1091-1097
    • /
    • 2017
  • Sales of commercial-type cooling fans intended for application in military electronics are often discontinued during equipment production. This results in requirements for alternative fan selection as well as equipment performance and reliability tests, such as high-temperature operation testing. This study deals with alternative fan selection and verification methods that can be used during the production process. First, an alternative fan was selected by calculating the flow and pressure required to effectively cool the equipment, then the feasibility of the selected fan was verified using a reliable CFD heat dissipation analysis model. Following this, a high-temperature operation test was performed using the alternative fan in the equipment. Results demonstrated that the equipment satisfied its required function in a high-temperature environment, and the main parts as well as internal air temperature were found to be thermally stable.

Experiments on the Cooling Characteristics of a Channel with Pin-Fin Array (핀-휜 배열을 이용한 채널의 냉각특성 실험)

  • Kim, Sang-Min;Shin, Jee-Young;Son, Young-Seok;Lee, Dae-Young
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.31-36
    • /
    • 2003
  • Recently, the power consumption and heat generation in an electronic equipment increase as the components are miniaturized and the computing speed becomes faster. Effective cooling method is required to ensure the guaranteed performance and reliable operation of the electronic devices. The aim of the present study is to investigate the cooling characteristics of a pin-fin heat exchanger as a candidate for cooling system of the electronic devices. Various configuration of the pin-fin array is selected in order to find out the effect of spacing and diameter of the pin-fin on the heat transfer characteristics. The results are compared with the experimental data or correlations of several researchers for the channel flow with pin-fin arrays.

  • PDF

An Experimental Study on Cooling Characteristic according to Fin Array of Aluminum Heat Sink (히트싱크의 핀 배열에 따른 냉각특성에 관한 실험적 연구)

  • Yoon, Sung-Un;Kim, Jae-Yeol;Gao, Jia-Chen
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.1
    • /
    • pp.138-143
    • /
    • 2018
  • In general, the operating temperature of electronic equipment is closely related to product life and reliability, and it is recognized that effectively cooling the parts is an important problem. In this paper, an experimental study on the cooling characteristic according to the pin array of the heat sink is conducted. The experiment on the heat sink was based on the natural convection and temperature distribution changes. The experimental results indicate that the pin array of the heat sink has an effect on the thermoelectric module's cooling characteristic.

Application of Evaporative Cooling Technology in HDVC Converter Station

  • Guo, Jianhong;Wang, Haifeng;Ai, Chengliu;Gu, Guobiao
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.1
    • /
    • pp.105-109
    • /
    • 2014
  • Converter valve cooling device as the heat exchanger, is known as the converter valve's blood circulation system, Inefficiency of the equipment will not only lead to the component overheating damage, but also serious DC system outage. Therefore, reliable HVDC valve cooling system is essential for the HVDC transmission system. In this article, analysis on the two-phase flow heat transfer characteristics and security of the evaporative cooling technology are provided, the technology's advantage and feasibility are discussed.

Cooling System Design Factors related to Mechanical Load Component (MLC) in Data Center (데이터센터 냉방 시스템의 MLC(Mechanical Load Component) 관련 설계인자 도출)

  • Kim, Ji-Hye
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • v.12 no.6
    • /
    • pp.606-617
    • /
    • 2018
  • Increased density of racks has resulted in increased use of data center cooling energy and the needs for energy efficient cooling systems has increased. In response to these needs, ASHRAE presented a performance indicator, which is Mechanical Load Component (MLC), for the purpose of evaluating systems at the design stage. However, the MLC metrics presented in the current standard can only be determined for system compliance and compared alternative systems with the system configuration completed. Therefore, there are limitations to considering MLC from the early stages of design. In this study, to extend the scope of application of MLC in the design phase, the design factors of the main equipment comprising the cooling system are classified by the MLC load component and interrelations between design factors were identified.

A Study on a Heat-load of IT Equipments for the Thermal Environment Control in the Data Center (데이터센터의 합리적인 환경제어를 위한 장비 발열기준에 대한 연구)

  • Cho, Jin-Kyun;Hong, Min-Ho;Jeong, Cha-Su;Kim, Byung-Seon
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.938-943
    • /
    • 2006
  • The primary purpose of a computer room of data center and associated infrastructure is to support the operation of critical IT equipment. Traditionally, most owners of large critical data centers have been more than willing to accept a reasonable amount of computer room worker discomfort if necessary to support critical IT systems. All electrical equipment produces heat, which must be removed to prevent the equipment temperature from rising to an unacceptable level. Most information technology equipment and other equipment found in a data center or network room is air-cooled. Sizing a cooling system requires an understanding of the amount of heat produced by the equipment contained in the enclosed space, along with the heat produced by the other heat sources typically encountered.

  • PDF

A Study on the Combined Equipment for the Pre-cooling and the Thawing using the Low Temperature Vacuum System (저온진공기술을 이용한 예냉 및 해동 겸용장치에 관한 연구)

  • 김성규;박영승;최현규;이정혜;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.2
    • /
    • pp.280-288
    • /
    • 2003
  • We need refrigeration system which can maintain the freshness of agricultural products, because of being distance from a tiller to a consumer. Vacuum Pre-cooling system has an advantage in quality maintenance through vapid cooling down by using latent heat of evaporation of stored products. A number or thawing methods in current use have also several disadvantages in thawing time. discoloration mass loss caused by drying, capital costs and running cost. These damages are, it is claimed, either eliminated or improved by the vacuum thawing system. An experimental study on the pre-cooling for the bean sprouts and cabbage, and thawing for hairtail and croaker by the low temperature vacuum system were carried out. The cabbage cooling time with this Pre-cooling vacuum system took about 60 minutes to reach from $23.2^{circ}C to 4.5^{\circ}C$ at 5 mmHg abs. ($6.66\times10^{-4}$ MPa). The croaker thawing time with this low temperature vacuum thawing system took about 170 minutes to reach from $-10.3^{circ}C to -0.8^{\circ}C$ at 20 mmHg abs ($2.67\tiems10^{-3}$MPa). The vacuum Pre-cooling and thawing system have merits compared with present systems in their short intervals to cool down and to thaw without any quality losses.