• Title/Summary/Keyword: Cooling degree day

Search Result 29, Processing Time 0.03 seconds

The expectation of future cooling and heating degree day of the Seoul and Ulsan using HadCM3 (HadCM3를 이용한 서울 및 울산지역의 미래 냉.난방도일 예측)

  • Lee, Kwan-Ho;Yoo, Ho-Chun;Noh, Kyoung-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.160-165
    • /
    • 2008
  • The concern in energy reduction in the field of architecture which takes up a big weight in domestic energy consumption is gradually increasing. For this reason, a lot of research work on this matter is being carried out. Particularly, it is generally required that currently used system in a structure for energy reduction should be maximized in its efficiency. In addition, research on several energy reduction typed systems is underway. Such a research work should not only include the one in time of the present but also keep up with the trend for future-oriented research. This research paper forecasted and analyzed the trend for global warming and demand of a structure for energy in the future by applying climate scenarios to cooling degree-day and heating degree-day. Also, this research found out the decrease in heating degree-days and increase in cooling degree-days until this moment due to the progress of global warming. In addition, as for heating degree-days in the future forecasted on the basis of HadCM3, it is estimated that the range of decrease could be ever bigger starting 2040 in case of Seoul and also starting 2010 in case of Ulsan ever after respectively. In case of cooling degree-days, it is estimated that its increase range could be bigger abruptly starting 2050, and after 2080, its increase range would be much bigger.

  • PDF

Analysis of Urban Warming Phenomenon using Degree days in Major Korean Cities (냉난방도일을 이용한 우리나라 주요도시의 도시승온화현상 특성분석)

  • Kim, Hae Dong;Park, Myeong Hui;Song, Gyeong Suk
    • Journal of Environmental Science International
    • /
    • v.13 no.3
    • /
    • pp.189-196
    • /
    • 2004
  • Characteristics of urban wanning phenomenon were studied using degree days for three big cities(Seoul, Busan, Daegu) adjacent to airport. Time variation of the cooling and heating degree days was analyzed using the daily mean air temperature data measured at the six meteorological observatory for long-term periods(25~43years). The results for the big cities are as followings: 1) It was found that the heating degree days trended to decrease from year to year. 2) The cooling degree days were nearly unchanged during the same analysis periods. 3) The number of days calling for air-heating also tended to decrease as time passes. 4) Those of air-cooling were nearly unchanged during the same time. It suggests that the change of air-heating condition owing to urbanization came in evidence in the winter season, but that of air-cooling condition was slight in the summer season. On the other hand, the long-term trends of degree days were very small in airport areas except for Kimhae airport. Hence, the gaps of degree days between big cities and rural airport areas are increasing.

The Demand Expectation of Heating & Cooling Energy in Buildings According to Climate Warming (기후 온난화의 영향에 의한 건물의 냉.난방에너지 수요량 예측)

  • Kim, Ji-Hye;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.3
    • /
    • pp.119-125
    • /
    • 2006
  • The impacts of climate changes on building energy demand were investigated by means of the degree-days method. Future trends for the 21st century was assessed based on climate change scenarios with 7 global climate models(GCMs). We constructed hourly weather data from monthly temperatures by Trnsys 16. A procedure to estimate heating degree-days (HDD) and cooling degree-days (CDD) from monthly temperature data was developed and applied to three scenarios for Inchon. In the period 1995-2080, HDD would fall by up to 70%. A significant increase in cooling energy demand was found to occur between 1995-2004(70% based on CDD). During 1995-2080, CDD would Increase by up to 120%. Our analysis shows widely varying shifts in future energy demand depending on season. Heating costs in winter will significantly decrease whereas more expensive electrical cooling energy will be needed.

A Study on Heating and Cooling Degree-Days Calculation Methods with NCDC Data (NCDC데이터를 활용한 냉난방도일 산정 및 계산방법에 관한 연구)

  • Seo, Dong-Hyun;Song, Yujin
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.6
    • /
    • pp.77-84
    • /
    • 2013
  • Degree-day method is very simple but essential index to estimate heating and cooling energy demand in buildings. It has been neglected, however, for the simplicity so it is difficult to find any DB for south Korean cities. Even meteorological department of S. Korea doesn't report the data officially. In this study, current methods that are being used in many countries are investigated and used to calculate degree-days of 35 south Korean cities with 30 years(1981~2010) historical data. The calculation result indicates that the error among 4 major methods are dependent on how daily or hourly temperature are treated in the calculation and how balance point temperature is defined. The errors of the methods are no larger than 6% relative to hourly degree-day method.

A Study on Prediction of Power Consumption Rate for Heating and Cooling load of School Building in Changwon City (창원시 학교 건축물의 냉난방부하에 대한 전력 소비량 추정에 관한 연구)

  • Park, Hyo-Seok;Choi, Jeong-Min;Cho, Sung-Woo
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.11 no.2
    • /
    • pp.19-27
    • /
    • 2012
  • This study was carried out in order to establish the estimation equation for school power consumption using regression analysis based on collected power consumption for two years of weather data and schools are located in Central Changwon and Masan district in Changwon city. (1) The power consumption estimation equation for Heating and cooling is calculated using power consumption per unit volume, the difference between actual power consumption and results of estimation equations is 4.1%. (2) The power consumption estimation equation for heating load is showed 2.6% difference compared to actual power consumption in Central Changwon and is expressed 2.9% difference compared to that in Masan district. Therefore, the power consumption prediction for each school using the power consumption estimation equation is possible. (3) The power consumption estimation equation for cooling load is showed 8.0% difference compared to actual power consumption in Central Changwon and is expressed 2.9% compared to that in Masan district. As the power consumption estimation equation for cooling load is expressed difference compared to heating load, it needs to investigate influence for cooling load.

A Study on the Cooling Load of South and East Facing Apartment Houses (남향과 동향 집합주택의 냉방부하에 관한 연구)

  • 박근우;이경희
    • Journal of the Korean housing association
    • /
    • v.11 no.2
    • /
    • pp.129-137
    • /
    • 2000
  • This study is about the difference of South and East facing Cooling load of Apartment s Houses using Dynamic Heat-flow Calculation. Therefore, the purpose of this study is come in to use Material for the Thermal Environments of Apartment Houses. The results of the analysis are below. (1) For the peak load of degree hour; The highest is "I" unit and the next high load is H, F, E, C, B, G, D and A unit for the south facing Apartment houses. The higher load is "H" unit and the next high load is I, E, F, B, C, G, D, A Unit for the east facing Apartment houses. (2) For the total load of degree day; The highest load is "I" unit and the next high load is H, G, F, E, C, B, D and A Unit for the south facing Apartment houses. The highest load is "H" unit and the next high load is I, G, E, F, B, C, D, A Unit for the east facing Apartment houses. (3) For the total load of degree day; The highest load is "H" Unit for the east facing Apartment houses and the Lowest load is "A" Unit for the south facing Apartment houses.is "A" Unit for the south facing Apartment houses.nt houses.

  • PDF

Gas cooling for optimization of mold cooling (금형 냉각 최적화를 위한 기체 보조 냉각)

  • Lim, Dong-Wook;Kim, Ji-Hun;Shin, Bong-Cheol
    • Design & Manufacturing
    • /
    • v.12 no.1
    • /
    • pp.18-25
    • /
    • 2018
  • Both injection and injection molding dies have evolved into advanced technology. Product quality is also evolving day after day. Therefore, the conditions of the injection mold and the injection conditions are becoming important. In order to improve the quality of the product, the Hardware part of the mold has developed as an advanced technology, and the Software part has also developed with advanced technology. This study deals with the cooling part, which is part of the hardware. In addition to fluid cooling, which is commonly used in the industry, by using gas cooling identify the phenomena that appear on the surface of the product and the critical point strain of the product to find the optimal cooling. Electronic parts and automobile parts whose surface condition is important, the cooling process is important to such a degree that they are divided with good products and defective products according to the cooling process at the time of injection. By controlling this important cooling and reducing the injection time with additional cooling, the product quality can be increased to the highest production efficiency. In addition, high efficiency can be achieved without additional investment costs. This study was conducted to apply these various advantages in the field.

Basic Study on Sub-cooling System using Ice storage tank (빙축열조를 이용한 냉매과냉각 시스템 기초연구)

  • Lee, Eun-Ji;Lee, Dong-Won;Kim, Yong-Chan
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.990-995
    • /
    • 2009
  • Experimental basic study was performed to understand the characteristics of sub-cooled refrigerant using a cold heat storage system. This system was made up general vapor-compression refrigeration cycle added sub-cooler and ice storage tank. The purpose of this study are to application use of cold-heat storage systems multiplicity of fields and to understand of sub-cooling system. At the condition using ice storage system, the ice making process was operated during night time by electric power. And then, the refrigerant was sub-cooled using stored cold-heat after being discharged from the air cooling condenser during the day time. Comparing the result at general operation with the operation using sub-cooling system. This study showed the effects of the sub-cooled degree. The cooling performance was increased owing to the sub-cooling of refrigerant during day time, and the compressor consume power was a little decreased. Thus the COP was also increased owing to the sub-cooling of refrigerant.

  • PDF

Estimating Cooling and Heating Degree Days for Variable Base Temperature (서울 및 부산지역의 가변 평형점온도에 따른 냉난방도일 산정법에 관한 연구)

  • Ihm, Pyeongchan;Jung, Soon-Sung;Seo, Donghyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.2
    • /
    • pp.79-85
    • /
    • 2014
  • In general, building energy performance is evaluated with a detailed transient building energy simulation program. However, energy evaluation tools with the bin method are still used, because of their simple and easy way to calculate building energy performance, without reducing their precision. In this research, several heating and cooling degree day methods are compared, and evaluated with their performance for variable base temperature. This analysis considered about ten years of the continuous outdoor temperature, in the Seoul and Busan areas. It is concluded that the simplified bin method is more or less acceptable for Seoul and Busan, compared with the detailed hourly bin method.

Studies on the Effect of Low Temperature Treatment at Meiotic, Heading and Seedling Stage in Paddy Rice (수도의 장해형 냉해에 관한 연구)

  • Hong-Suk Lee;Hyung-Yull Cho;Pyeong-Ki Yim;Hoon Heu
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.15
    • /
    • pp.85-97
    • /
    • 1974
  • In order to clarify the inducing conditions and cause of sterility in rice plants, 4 varieties were cooled at 3 different levels of temperature combined with 3 different levels of treatment period. And 19 varieties were tested to examine the varietal difference of cold resistance. The results obtained were summarized as follows; 1. There were significant varietal differences in the effect of cooling treatment at meiotic stage. Suwon 213-1 was induced heavy sterility by 3 day cooling treatment at 17.5$^{\circ}C$ whereas Hayayuki, Nongpaik and Jinheung were induced a little sterility by 3 day cooling treatment at 15$^{\circ}C$ and 5 day treatment at 17.5$^{\circ}C$. The per cent of grain fertility was correlated significantly with the delayed days to heading, the degree of panicle extraction (Suwon 213-1, Nongpaik, Jinheung), culm length (Nongpaik, Suwon 213-1), and Auricle distance (Suwon 213-1). The degree of sterility was able to be estimated from the linear regression equation between the degree of panicle extraction (distance from panicle neck to flag leaf) and fertility percentage. In the case of heavy cold damage by the treatment of low temperature at meiotic stage, the rice plant had somewhat lower pollen density per anther, small and ununiform anther and pollen in size, and more sterile pollen grains. Suwon 213-1 showed anthesis in almost all spikelets, while Nongpaik, Jinheung and Hayayuki indicated considerable number of indehisced anther at 5 days after heading. 2. The fertility were not generally higher in cooling treatment at heading stage than at meiotic stage treatment. And significant correlation was found between the percentage of grain fertility treated at above two stages. Nongpaik and Jinheung were not affected in percentage of fertility by 5 day treatment at 15$^{\circ}C$ when these were treated at heading stage. Indehisced anthers were not found in Suwon 213-1 and Hayayuki, but Nongpaik and Jinheung showed more anthers which did not show anthesis 3. There was different varietal response to low temperature which was indicated by the decrease of grain fertility resulted from cooling treatment at meiotic stage. Jaekeun and Jinheung did not show low fertility but Milseong, Suwon 210, Satominoli and Suwon 213-1 showed outstanding decrease in fertility percentage by the cooling treatment at meiotic stage. The varieties which had low fertility were likely to have low pollen density per anther, abnormal anthers, small size po]]en grains and many sterile pollens. 4. Remarkable varietal difference of cold resistance was found in heading stage cooling treatment. Nongpaik, Jinheung, Jaekeun, Paltal, Akibare, Milseung and Palkeong were not affected in grain fertility by cooling treatments but Nonglimna No. 1, Suseong, Hayayuki, Suwon 213-1 and Suwon 210 showed significantly high sterility as treated by cool temperature. Most of the varieties showed higher fertility by cooling treatment at heading stage than meiotic stage but Hayayuki, Suseong and Nonglimna No.1 showed lower fertility when these were treated at heading stage than meiotic stage. There were two grops of varieties in the response to cooling treatment, one was somewhat non-anthesised and the other showed full anthesis. 5. In cold injury test of young seedlings, the result of observation was not accorded with the degree of growth inhibition. As a general, Palkeum and Suseong were highly torelant to cool temperature but Suwon 213-1, Jaekeun, Paltal, Shirogane, Palkeong, Mankyung were highly susceptible. 6. There is no significant correlation between the degree of young seedling cold damage and or the degree of growth retardation at seedling stage and grain fertility resulted from coding treatment both heading and meiotic stage.

  • PDF