• 제목/요약/키워드: Cooling curve

검색결과 183건 처리시간 0.023초

가속냉각처리한 API-X70강의 미세조직과 기계적 특성에 미치는 구상화 열처리시간의 영향 (Effect of Spherodizing Heat-treatment Time on Microstructure and Mechanical Property in Accelerated Cooling-treated API-X70 Steel)

  • 배동수
    • 한국산업융합학회 논문집
    • /
    • 제24권5호
    • /
    • pp.525-530
    • /
    • 2021
  • The purpose of this study was to investigate the effect of spherodizing heat treatment holding time on the microstructure and mechanical properties of the accelerated cooling-treated API X70 steel, which is mainly used as a structural material for line pipe steel for natural gas pipes. The accelerated cooling-treated API X70 steel was spherodizing treated at 700℃ for 12~48 h. The microstructure was observed using an OM and a FEG-SEM, and mechanical properties were obtained by tensile test. The microstructure of the API X70 steel was banded in the hot rolling direction, and the polygonal ferrite(PF) adjacent to pearlite(P) has mainly a fine size, and coarse PF and fine acicular ferrite were formed in the middle of P and P. As the spherodizing treatment time increased, the number of carbide particles decreased and its distribution interval increased, and the ferrite grain size was coarsened. The tensile strength decreased and the ductility increased with spherodizing treatment time, and the yield point elongation was disappeared in a stress-strain curve after the spherodizing treatment.

전동차용 모터 냉각홴의 공력성능 향상 및 소음특성 (Aerodynamic Performance Enhancement and Noise of Cooling Fans for Driving Motor)

  • 강신형;박태춘;조남효
    • 한국유체기계학회 논문집
    • /
    • 제1권1호
    • /
    • pp.32-40
    • /
    • 1998
  • Aerodynamic performance of a cooling fan of driving motor was enhanced modifying the vane-shroud configuration. Performance of a target model was evaluated to obtain baseline data. The aerodynamic performance and sound pressure level were tested and measured with different numbers of vane of increased length. The tested models show high and stable performance and low values of specific noise level. The long vane-shroud structure induces more stable through flow and decreases the tip leakage flow, which contributes to the increases of performance and efficiency. The sound pressure level increases for the modified model, however, specific noise level decreases.

  • PDF

파이프쿨링을 적용한 양평대교 직접기초의 수화열 제어대책에 관한 시공사례 (Construction Example of the Hydration Heat Control for Foundation of Yang Pyeong Bridge with Pipe Cooling)

  • 경제운;박진태;이명성;오세호;이용학
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.441-444
    • /
    • 2006
  • The Yang Pyeong bridge is high the occurred possibility of temperature crack by means of hydration Heat when the foundation of is constructed. Therefore, a pipe-cooling method was applied for reducing the temperature crack. Using the measured temperature curve when construction was carried out, the measured value and different facts were analyzed. In this paper, cause and analysis with respect to a mentioned above is to discuss firstly, and thermal characteristics of concrete and construction method hereafter is also discussed.

  • PDF

Large Cryosorption Pump for the NBI Test Stand

  • In, S.R.;Shim, H.J.
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제7권2호
    • /
    • pp.27-32
    • /
    • 2003
  • A large cryo-pumping system composed of 4 cryosorption pumps was designed and manufactured to satisfy the pressure requirements of the NBI test stand. The cryosorption pump consists of a thermal shield/baffle assembly and a cryopanel coated with activated carbon granules. The thermal shield is cooled by liquid nitrogen, and the cryopanel by a commercial helium refrigerator. The operation characteristics and vacuum performance of the cryosorption pump were investigated. The cooling down time of the cryopanel to 20 K was about 6 hours with a liquid nitrogen consumption rate of about 35 L/hr. The maximum pumping speed of the cryosorption pump for the hydrogen gas measured by the steady pressure method was about 90,000 L/s.

  • PDF

파이프쿨링을 적용한 양평대교 직접기초의 수화열 제어대책에 관한 시공사례 (Construction Example of the Hydration Heat Control for Foundation of Yang Pyeong Bridge with Pipe Cooling)

  • 오세호;경제운;박진태;신동훈;이명성;이용학
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.717-720
    • /
    • 2006
  • The Yang Pyeong bridge is high the occurred possibility of temperature crack by means of hydration Heat when the foundation of is constructed. Therefore, a pipe-cooling method was applied for reducing the temperature crack. Using the measured temperature curve when construction was carried out, the measured value and different facts were analyzed. In this paper, cause and analysis with respect to a mentioned above is to discuss firstly, and thermal characteristics of concrete and construction method hereafter is also discussed.

  • PDF

자유팽창으로 생성된 아세틸렌 Cluster의 온도변화에 관한 모델링 (The Modeling of Temperature Changes of Acetylene Clusters formed in Free Jet Expansion)

  • 이경희;김홍락;김철현
    • 한국가스학회지
    • /
    • 제7권1호
    • /
    • pp.41-46
    • /
    • 2003
  • 14atm, 233K의 아세틸렌 기체를 자유팽창 시켜서 생성한 아세틸렌 cluster의 상과 온도 변화를 실험적으로 측정하였으며, cluster를 여러 겹의 shell로 나누어 취급하고 각 shell 마다 증발과 열전도 현상에 근거한 온도계산을 하는 모델링을 적용하여 이론적인 온도를 구하고 실험값과 비교함으로써, 생성된 cluster의 크기를 4.88$\mu$으로 결정하였다.

  • PDF

Research on fast cool-down of orifice pulse tube refrigerator by controlling orifice valve opening

  • Kim, Hyo-Bong;Park, Jong-Ho
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권4호
    • /
    • pp.36-40
    • /
    • 2010
  • In this paper, a noble method for rapid cooldown of pulse tube refrigerator (PTR) was proposed and experimentally investigated. An orifice pulse tube refrigerator generates refrigeration effect by expansion PV work at the cold-end, and its amount is affected by the orifice valve opening. There exists the optimum valve opening for maximum cooling capacity and it varies as cold-end temperature. It is verified from simulation results using isothermal model that the optimum valve opening increases as the cold-end temperature increases. In the experiments, a single stage orifice pulse tube refrigerator is fabricated and tested. The fabricated PTR shows 97.5 K of no-load temperature and 10 W at 110 K of cooling capacity with the fixed orifice valve opening. From experiments, the initial cooldown curve with four cases of valve opening control scenario are obtained. And it is experimentally verified that the initial cooldown time can be reduced through the control of orifice valve opening.

Effect of Days Open on the Lactation Curve of Holstein Cattle in Saudi Arabia

  • Ali, A.K.A.;AI-Haidary, A.;Alshaikh, M.A.;Gamil, M.H.;Hayes, E.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제13권3호
    • /
    • pp.277-286
    • /
    • 2000
  • A total of 21,441 milking records of biweekly test-days were collected from six dairy farms of Almarai company, Saudi Arabia to determine the effect of days open on lactation curve and milk production during the period of 1991 to 1996. These records included cows calved in two seasons: winter, for cows calved from October to March and summer, for cows calved from April to September. Season of calving did not have a significant effect on the last biweekly points of the curve, and this is due to the effect of the evaporative cooling system. Days open had a marked effect on milk production. The difference in milk yield between cows with days open <60 days and days open >150 days was 1,021 liter. Moreover, the difference in milk yield at early lactation decreased from 1,021 to 829 liter as the days open increased from 75 to 125, due to the decrease in the effect of conception on milk production with advancing lactation. These data also showed that the middle part of the curve (105-255) was the least affected part by the variation in days open because the pregnancy effect become more obvious after five months of conception. These data showed that the dairy cattle produce more than 70% of the milk yield during the first 250 days of the lactation curve.

사술성형 모사에 있어서 벽면 경계조건 처리를 위한 선단 유동장 생성기법과 spline 곡선을 이용한 선단 격자 재구성 (Frontal Flow Field Construction for Wall Boundary Condition Treatment and Frontal Remeshing Using Spline Curve in Injection Molding Simulation)

  • 윤재륜
    • 유변학
    • /
    • 제5권1호
    • /
    • pp.34-48
    • /
    • 1993
  • 최근 CAD/CAM의 발전과 더불어 사출성형공정은 여러분야에 폭넓게 응용되고 있 다. 사출성형공정은 크게 충전과정(filling stage), 냉각과정(cooling stage), 보압과정(packing stage)로 나누어 지는데 이중 충전과정은냉각과정과 보압과정에서 나타날 물리적인 현상과 최종 성형품의 기계적 성질에 중요한 영향을 끼치게 된다. 충전과정의 수치 해석 방법은 대 표적으로 control volume method, branching flow method, transient moving boun-dary method로 구분된다. 본 연구에서는 격자의 형태를 양호하게 형성시키고 유동선단의 형태를 개선하기위한 기법인 Spline 곡선을 이용한 선단격자 재구성(frontal remeshing using spline curve)과 수치해석에 소요되는 시간을 줄이기 위하여 벽면경계조건 처리를 위한 선단 유동 장생성(frontal flow field construction for wall boun-dary condition treatment)기법을 개발 하고 transient moving voundary method에 적용시켜 원형 평판과 인장 및 굽힘시편 그리고 두께가 변하는 사각 형상을 가진 캐비터에서의 충전과정을 수치해석하였다. 그결과 압력 분 포, 온도분포, 속도장, 유동선단의 진전형태 등이 기존에 제출된 해석결과와 비교하여 볼 때 만족스러운 수치해석결과를 보였다.

  • PDF

Study of the Hopkinson Effect in the HDDR-treated Nd-Fe-B-type Material

  • Kwon, H.W;Shon, S.W
    • Journal of Magnetics
    • /
    • 제6권2호
    • /
    • pp.61-65
    • /
    • 2001
  • The Hopkinson effect in the HDDR-treated $Nd_{15}Fe_{77}B_8$ allay was examined in detail by means of a thermo-magnetic analysis with low magnetic field (600 Oe). The emergence and magnitude of maximum in magnetisation in the thermomagnetic curve due to the Hopkinson effect was correlated with the grain structure and coercivity of the HDDR-treated material. The HDDR-treated materials showed a clear Hopkinson effect (maximum in magnetisation just below the Curie temperature of the $Nd_2Fe_{14}B\;$ phase) on heating. The magnitude of the magnetisation rise due to the Hopkinson effect became smaller as the recombination time increased. The magnetisation recovery at room temperature on cooling from above the Curie temperature became smaller as the recombination time increased. The HDDR-treated materials with shorter recombination time, finer grain size and higher coercivity showed larger magnetisation maximum due to the Hopkinson effect in the thermo-magnetic curve.

  • PDF