• 제목/요약/키워드: Cooling channel

검색결과 439건 처리시간 0.027초

설비공학 분야의 최근 연구 동향: 2008년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2008)

  • 한화택;최창호;이대영;김서영;권용일;최종민
    • 설비공학논문집
    • /
    • 제21권12호
    • /
    • pp.715-732
    • /
    • 2009
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2008. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends in thermal and fluid engineering have been surveyed in the categories of general fluid flow, fluid machinery and piping, new and renewable energy, and fire. Well-developed CFD technologies were widely applied in developing facilities and their systems. New research topics include fire, fuel cell, and solar energy. Research was mainly focused on flow distribution and optimization in the fields of fluid machinery and piping. Topics related to the development of fans and compressors had been popular, but were no longer investigated widely. Research papers on micro heat exchangers using nanofluids and micro pumps were also not presented during this period. There were some studies on thermal reliability and performance in the fields of new and renewable energy. Numerical simulations of smoke ventilation and the spread of fire were the main topics in the field of fire. (2) Research works on heat transfer presented in 2008 have been reviewed in the categories of heat transfer characteristics, industrial heat exchangers, and ground heat exchangers. Research on heat transfer characteristics included thermal transport in cryogenic vessels, dish solar collectors, radiative thermal reflectors, variable conductance heat pipes, and flow condensation and evaporation of refrigerants. In the area of industrial heat exchangers, examined are research on micro-channel plate heat exchangers, liquid cooled cold plates, fin-tube heat exchangers, and frost behavior of heat exchanger fins. Measurements on ground thermal conductivity and on the thermal diffusion characteristics of ground heat exchangers were reported. (3) In the field of refrigeration, many studies were presented on simultaneous heating and cooling heat pump systems. Switching between various operation modes and optimizing the refrigerant charge were considered in this research. Studies of heat pump systems using unutilized energy sources such as sewage water and river water were reported. Evaporative cooling was studied both theoretically and experimentally as a potential alternative to the conventional methods. (4) Research papers on building facilities have been reviewed and divided into studies on heat and cold sources, air conditioning and air cleaning, ventilation, automatic control of heat sources with piping systems, and sound reduction in hydraulic turbine dynamo rooms. In particular, considered were efficient and effective uses of energy resulting in reduced environmental pollution and operating costs. (5) In the field of building environments, many studies focused on health and comfort. Ventilation. system performance was considered to be important in improving indoor air conditions. Due to high oil prices, various tests were planned to examine building energy consumption and to cut life cycle costs.

설비공학 분야의 최근 연구 동향 : 2012년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2012)

  • 한화택;이대영;김사량;김현정;최종민;박준석;김수민
    • 설비공학논문집
    • /
    • 제25권6호
    • /
    • pp.346-361
    • /
    • 2013
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2012. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. The conclusions are as follows : (1) The research works on thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and valves, fuel cells and power plants, ground-coupled heat pumps, and general heat and mass transfer systems. Research issues are mainly focused on new and renewable energy systems, such as fuel cells, ocean thermal energy conversion power plants, and ground-coupled heat pump systems. (2) Research works on the heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer, and industrial heat exchangers. Researches on heat transfer characteristics included the results for natural convection in a square enclosure with two hot circular cylinders, non-uniform grooved tube considering tube expansion, single-tube annular baffle system, broadcasting LED light with ion wind generator, mechanical property and microstructure of SA213 P92 boiler pipe steel, and flat plate using multiple tripping wires. In the area of pool boiling and condensing heat transfer, researches on the design of a micro-channel heat exchanger for a heat pump, numerical simulation of a heat pump evaporator considering the pressure drop in the distributor and capillary tubes, critical heat flux on a thermoexcel-E enhanced surface, and the performance of a fin-and-tube condenser with non-uniform air distribution and different tube types were actively carried out. In the area of industrial heat exchangers, researches on a plate heat exchanger type dehumidifier, fin-tube heat exchanger, an electric circuit transient analogy model in a vertical closed loop ground heat exchanger, heat transfer characteristics of a double skin window for plant factory, a regenerative heat exchanger depending on its porous structure, and various types of plate heat exchangers were performed. (3) In the field of refrigeration, various studies were executed to improve refrigeration system performance, and to evaluate the applicability of alternative refrigerants and new components. Various topics were presented in the area of refrigeration cycle. Research issues mainly focused on the enhancement of the system performance. In the alternative refrigerant area, studies on CO2, R32/R152a mixture, and R1234yf were performed. Studies on the design and performance analysis of various compressors and evaporator were executed. (4) In building mechanical system research fields, twenty-nine studies were conducted to achieve effective design of mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, renewable energy systems, and lighting systems in buildings. New designs and performance tests using numerical methods and experiments provide useful information and key data, which can improve the energy efficiency of buildings. (5) In the fields of the architectural environment, studies for various purposes, such as indoor environment, building energy, and renewable energy were performed. In particular, building energy-related researches and renewable energy systems have been mainly studied, reflecting interests in global climate change, and efforts to reduce building energy consumption by government and architectural specialists. In addition, many researches have been conducted regarding indoor environments.

설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제28권6호
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.

심자도용 접선성분자장 측정방식 스퀴드 센서열 설계 (Design of a SQUID Sensor Array Measuring the Tangential Field Components in Magnetocardiogram)

  • 김기웅;이용호;권혁찬;김진목;김인선;박용기;이규원
    • Progress in Superconductivity
    • /
    • 제6권1호
    • /
    • pp.56-63
    • /
    • 2004
  • We consider design factors for a SQUID sensor array to construct a 52-channel magnetocardiogram (MCG) system that can be used to measure tangential components of the cardiac magnetic fields. Nowadays, full-size multichannel MCG systems, which cover the whole signal area of a heart, are developed to improve the clinical analysis with high accuracy and to provide patients with comfort in the course of measurement. To design the full-size MCG system, we have to make a compromise between cost and performance. The cost is involved with the number of sensors, the number of the electronics, the size of a cooling dewar, the consumption of refrigerants for maintenance, and etc. The performance is the capability of covering the whole heart volume at once and of localizing current sources with a small error. In this study, we design the cost-effective arrangement of sensors for MCG by considering an adequate sensor interval and the confidence region of a tolerable localization error, which covers the heart. In order to fit the detector array on the cylindrical dewar economically, we removed the detectors that were located at the corners of the array square. Through simulations using the confidence region method, we verified that our design of the detector array was good enough to obtain whole information from the heart at a time. A result of the simulation also suggested that tangential-component MCG measurement could localize deeper current dipoles than normal-component MCG measurement with the same confidence volume; therefore, we conclude that measurement of the tangential component is more suitable to an MCG system than measurement of the normal component.

  • PDF

반도체 공정용 칠러의 채널별 제어특성에 관한 실험적 연구 (Experimental Study on the Control Characteristics of Each Channel in a Semiconductor Chiller)

  • 김현중;권오경;차동안;김용찬
    • 대한기계학회논문집B
    • /
    • 제35권12호
    • /
    • pp.1285-1292
    • /
    • 2011
  • 본 연구에서는 전자식 팽창밸브를 적용한 반도체 공정용 칠러에 관한 실험적 연구를 통해 시스템 특성을 파악하였다. 또한 온도 변화에 따른 신속한 대응을 할 수 있도록 온도상승 및 하강실험, 부하변화에 따른 온도영역별 제어정밀도 실험을 함으로써 각 제어 방식에 따른 운전 특성을 파악하였다. 온도상승 시 소비전력은 8.9 kW로 측정되었으며 CH1이 37.5분, CH2가 39.5분이 소요되었으며, 온도하강에는 총 26.5분이 소요되었다. 부분부하가 적용되는 경우 전부하가 적용되는 경우에 비해 제어정밀도의 변화폭이 큰 것으로 나타났으며 스텝모터 구동방식을 적용한 CH2의 제어정밀도가 상대적으로 우수한 것으로 나타났다. 냉각수를 이용한 냉각사이클 영역에서 소비전력은 1.8 kW로 냉동사이클을 적용한 방식에 비해 절반가량으로 감소된 것으로 나타났다. 본 연구는 실험결과를 바탕으로 반도체 공정용 칠러의 최적제어방안을 제시하였다.

인체에서 저체온 완전 순환 정지 시 뇌파검사의 의의 (The Significance of Electroencephalography in the Hypothermic Circulatory Arrest in Human)

  • 전양빈;이창하;나찬영;강정호
    • Journal of Chest Surgery
    • /
    • 제34권6호
    • /
    • pp.465-471
    • /
    • 2001
  • 배경: 저체온은 뇌 대사를 억제하여 뇌를 보호한다고 알려져 있으며, 대동맥 질환 수술 시 완전 순환 정지전에 충분히 시행되고 있다. 일반적으로 임상에서 직장 또는 비인두 온도를 지표로 순환정지를 시행하고 있으나, 순환정지 시 적절한 저체온의 온도 범위나 순환정지 온도를 결정하는 객관적인 지표에 대해서는 아직 명확한 결론이 없다. 본 연구는 수술 중 뇌파검사를 이용해 완전 순환 정지 시 안전한 직장 및 비인두 온도의 적정 수준을 확인하고, 적절한 저체온의 지표로서 뇌파검사의 역할을 알아보고자 하였다. 대상 및 방법: 1999년 3월부터 2000년 8월 31일까지 대동맥 질환으로 대동맥 인조혈관 치환수술 동안 뇌파검사를 병행하면서 완전 순환 정지를 했던 27명의 환자를 대상으로 하였다. 직장 온도와 비인두 온도를 마취유도부터 계속 감시하였으며, 뇌파검사는 10개의 채널로 마취유도부터 뇌 전위 고요상태(electrocerebral silence) 가지 관찰하였다 결과: 뇌 전위 고요 상태에 도달했을 때의 직장 온도와 비인두 온도는 일정한 범위에 있지 않고 다양한 값(직장 11$^{\circ}C$~$25^{\circ}C$; 비인두 7.7$^{\circ}C$ ~23$^{\circ}C$)을 보였으며, 두 온도 사이에 서로 관련이 없었다(p=0.171). 체외순환을 시작하여 뇌 전위 고요상태에 이르기까지 냉각 시간은 25~127분으로 다양하였으며, 환자의 체표면적과 연관이 있었다(p=0.027). 결과: 뇌 전위 고요상태는 다양한 체온에서 발생했으며, 임상에서 일반적으로 적용되는 직장 및 비인두 온도는 뇌 전위 고요상태를 지적할 수 없었다. 그러므로 심혈관계 수술 시 체온에 근거한 저체온 완전 순환 정지는 뇌의 보호를 확신할 수 없으며, 수술 중 뇌파검사의 관찰은 안전한 순환정지를 위한 적절한 저체온의 수준을 확보하기 위해 필요하며 합리적인 방법이었다.

  • PDF

산화제 과잉 예연소기용 분사기 설계 및 수류 시험 결과 (Results of Cold Flow Test and Design of Injectors for Oxidizer-rich Preburner)

  • 소윤석;우성필;이광진;유병일;김진형;조황래;방정석;한영민
    • 한국추진공학회지
    • /
    • 제22권1호
    • /
    • pp.52-57
    • /
    • 2018
  • 본 논문에서는 9톤급 다단연소사이클 엔진용 산화제 과잉 예연소기 분사기 설계 및 수류 시험 결과에 대해 기술하고자 한다. 총 3 종류의 동축 와류 분사기를 설계하고 각 종류마다 12개의 분사기를 제작하였다. 연료 접선 홀 직경은 모두 동일하며, 산화제와 연료가 연소되어 발생하는 기체 산화제와 냉각 채널에서 배출되는 액체 산화제 모멘텀의 비에 따라 산화제 과잉 예연소기 분사기의 연소에 어떠한 영향이 있는지를 연구하기 위해 산화제 접선 홀의 직경을 다르게 제작하였다. 추후에 산화제 과잉 예연소기를 이용한 파워팩과 연소시험을 통해 검증될 예정이다. 수류 시험 결과, 연료 유량 및 산화제 접선 홀의 유량값은 설계 차압을 기준으로 목표 유량값에 도달하였다.

Juan de Fuca 해령 Cleft Segment에서 회수된 황화물 침니: 광물조성 및 유체포유물 (Sulfide Chimney from the Cleft Segment, Juan de Fuca Ridge: Mineralogy and Fluid Inclusion)

  • 윤성택;허철호;소칠섭;염승준;이경용
    • 자원환경지질
    • /
    • 제35권3호
    • /
    • pp.203-210
    • /
    • 2002
  • 해저 열수 광화작용을 대효할 수 있는 황화물 침니(sulfide chimney)의 성장 메카니즘을 고찰하기 위하여 Juan de Fuca 혜령의 최남단에 위치하는 Cleft segment의 열수장(hydrothermal field)에서 회수한 비활동성이고 황화물과 실리카가 풍부한 침니를 대상으로 광물 및 유체포유물 연구를 수행하였다. 기존 연구에 의하면, Cleft sogment에는 많은 활동성 및 비활동성의 열수 분출구가 존재하는 것으로 보고되어 있다. 연구 대상 침니는 주로 비정질 실리카, 황칠석, 섬아연석 및 섬유아연석(wurtzite)으로 구성되어 있고,소량의 황동석 및 백칠석을 함유하고 있다. 유체통로로 추정되는 침니의 내부는 다공질이며, 비정질의 교질성(colloidal) 실리카로 피복되어 있다. 섬아연석과 섬유아연석으로 구성되어 있는 아연이 풍부한 황화물의 FeS 함량은 13.9~34.3 mole%의 범위를 보이며, 철이 풍부한 중심부와 철이 부족한 연변부를 지닌다. 이는 광화유체의 화학적.물리석 특성들의 변화로부터 기인되었으리라 사료된다. 침니 내부성장대별 화학조성은 열적구배 및 구성광물의 차이로 인해 다른 특징들을 보여주고 있다. 광화후기에 침전된 비정질 실리카중의 액상이 풍부한 유체포유물을 대상으로 가열 및 냉각 실험을 수행한 결과, 열수유체의 최소 포획 온도는 약 114$^{\circ}$~145$^{\circ}C$이며, 해당 염농도는 3.2~4.8 wt.% NaCl equip, 이다. 실제 열구에서 배출되는 유체 온도 자료를 입수하지는 못했지만, 본 연구를 통해서 광물의 침전작용 동안 상대적으로 저온의 침전조건이 매우 지배적이었음을 알수 있다. Juan de Fuca 해령내 Cleft seamen에서 회수된 황화물 침니는 산출형태, 교질성 조직, 전(bulk) 화학조성, 광물조합(황철석+백철석+섬유아연석+비정질 실리카) 등으로 볼 때, 기존 보고된 침니 유형보다는 상당히 낮은 온도에서 느린 유체 유동과 전도성 냉각(<25$0^{\circ}C$)에 의해 생성되었으리라 사료된다.

위증에 대한 동서의학적(東西醫學的) 고찰(考察) (The Literatual Study on the Wea symptom in the View of Western and Oriental Medicine)

  • 김용성;김철중
    • 혜화의학회지
    • /
    • 제8권2호
    • /
    • pp.211-243
    • /
    • 2000
  • This study was performed to investigate the cause, symptom, treatment, medicine of Wei symptom through the literature of oriental and western medicine. The results obtained were as follows: 1. Wei symptom is the symptom that reveals muscle relaxation without contraction and muscle relaxation occures in the lower limb or upper limb, in severe case, leads to death. 2. Since the pathology and etiology of Wei symptom was first described as "pe-yeol-yeop-cho"(肺熱葉焦) in Hung Ti Nei Ching(黃帝內經), for generations most doctors had have accepted it. but after Dan Ge(丹溪), it had been classified into seven causes, damp-heat(濕熱), phlegm-damp(濕痰), deficiency of qi(氣虛), deficiency of blood(血虛), deficiency of yin(陰處), stagnant blood(死血), stagnant food(食積). Chang Gyeng Ag(張景岳) added the cause of deficiency of source qi(元氣). 3. The concept of "To treat Yangming, most of all"(獨治陽明) was emphasized in the treatment of Wei symptom and contains nourishment of middle warmer energy(補益中氣), clearance of yangming-damp-heat(淸化陽明濕熱). 4. Since Nei-ching era(內經時代), Wei and Bi symptom(痺症) is differenciated according to the existence of pain. After Ming era(明代) appeared theory of co-existence of Wei symptom and pain or numbness but they were accepted as a sign of Wei symptom caused by the pathological factor phelgm(痰), damp(濕), stagnancy(瘀). 5. In the western medical point of view, Wei symptom is like paraplegia, or tetraplegia. and according to the causative disease, it is accompanied by dysesthesia, paresthsia, pain. thus it is more recommended to use hwal-hyel-hwa-ae(活血化瘀) method considering damp-heat(濕熱), qi deficiency of spleen and stornach(脾胃氣虛) as pathological basis than to simply differenciate Wei and Bi symptom according to the existence of pain. 6. The cause of Gullian-Barre syndrome(GBS) is consist of two factors, internal and external. Internal factors include asthenia of spleen and stomach, and of liver and kidney. External factors include summur-damp(暑濕), damp-heat(濕熱), cold-damp(寒濕) and on the basis of "classification and treatment according to the symptom of Zang-Fu"(臟腑辨證論治), the cause of GBS is classified into injury of body fluid by lung heat(肺熱傷津), infiltration of damp-heat(濕熱浸淫), asthenia of spleen and kidney(脾腎兩虛), asthenia of spleen and stomach(脾胃虛弱), asthenia of liver and kidney (肝腎兩虛). 7. The cause of GBS is divided by according to the disease developing stage: Early stage include dryness-heat(燥熱), damp(濕邪), phlegm(痰濁), stagnant blood(瘀血), and major treatment is reducing of excess(瀉實). Late stage include deficiency of essence(精虛), deficiency with excess(虛中挾實), and essencial deficiency of liver and kidney(肝腎精不足) is major point of treatment. 8. Following is the herbal medicine of GBS according to the stage. In case of summur-damp(暑濕), chung-seu-iki-tang(淸暑益氣湯) is used which helps cooling and drainage of summer-damp(淸利暑濕), reinforcement of qi and passage of collateral channels(補氣通絡). In case of damp-heat, used kun-bo-hwan(健步丸), In case of cool-damp(寒濕), used 'Mahwang-buja-sesin-tang with sam-chul-tang'(麻黃附子細辛湯合蓼朮湯). In case of asthenia of spleen and kidney, used 'Sam-lyeng-baik-chul san'(蔘笭白朮散), In case of asthenia of liver and kidney, used 'Hojam-hwan'(虎潛丸). 9. Following is the herbal medicine of GBS according to the "classification and treatment according to the symptom of Zang-Fu"(臟腑辨證論治). In the case of injury of body fluid by lung heat(肺熱傷津), 'Chung-jo-gu-pae-tang'(淸燥救肺湯) is used. In case of 'infiltration of damp-heat'(濕熱浸淫), us-ed 'Yi-myo-hwan'(二妙丸), In case of 'infiltration of cool-damp'(寒濕浸淫), us-ed 'Yui-lyung-tang', In case of asthenia of spleen, used 'Sam-lyung-bak-chul-san'. In case of yin-deficiency of liver and kidney(肝腎陰虛), used 'Ji-bak-ji-hwang-hwan'(知柏地黃丸), or 'Ho-jam-hwan'(虎潛丸). 10. Cervical spondylosis with myelopathy is occuered by compression or ischemia of spinal cord. 11. The cause of cervical spondylosis with myelopathy consist of 'flow disturbance of the channel points of tai-yang'(太陽經兪不利), 'stagnancy of cool-damp'(寒濕凝聚), 'congestion of phlegm-damp stagnant substances'(痰濕膠阻), 'impairment of liver and kidney'(肝腎虛損). 12. In treatment of cervical spondylosis with myelopathy, are used 'Ge-ji-ga-gal-geun-tang-gagam'(桂枝加葛根湯加減), 'So-hwal-lack-dan-hap-do-hong-eum-gagam(小活絡丹合桃紅飮加減), 'Sin-tong-chuck-ue-tang-gagam(身痛逐瘀湯加減), 'Do-dam-tang-hap-sa-mul-tang-gagam'(導痰湯合四物湯加減), 'Ik-sin-yang-hyel-guen-bo-tang'(益腎養血健步湯加減), 'Nok-gakyo-hwan-gagam'(鹿角膠丸加減). 13. The cause of muscle dystropy is related with 'the impairement of vital qi'(元氣損傷), and 'impairement of five Zang organ'(五臟敗傷). Symptoms and signs are classified into asthenia of spleen and stomach, deficiency with excess, 'deficiency of liver and kidney'(肝腎不足) infiltration of damp-heat, 'deficiency of qi and blood'(氣血兩虛), 'yang deficiency of spleen and kidney'(脾腎陽虛). 14. 'Bo-jung-ik-gi-tang'(補中益氣湯), 'Gum-gang-hwan'(金剛丸), 'Yi-gong-san-hap-sam-myo-hwan'(異功散合三妙丸), 'Ja-hyel-yang-gun-tang'(滋血養筋湯), 'Ho-jam-hwan'(虎潛丸) are used for muscle dystropy. 15. The causes of myasthenia gravis are classified into 'insufficiency of middle warmer energy'(中氣不足), 'deficiency of qi and yin of spleen and kidney'(脾腎兩處), 'asthenia of qi of spleen'(脾氣虛弱), 'deficiency of qi and blood'(氣血兩虛), 'yang deficiency of spleen and kidney'(脾腎陽虛). 16. 'Bo-jung-ik-gi-tang-gagam'(補中益氣湯加減), 'Sa-gun-ja-tang-hap-gi-guk-yang-hyel-tang'(四君子湯合杞菊地黃湯), 'Sa-gun-ja-tang-hap-u-gyi-eum-gagam'(四君子湯合右歸飮加減), 'Pal-jin-tang'(八珍湯), 'U-gyi-eum'(右歸飮) are used for myasthenia gravis.

  • PDF