• 제목/요약/키워드: Cooling channel

검색결과 437건 처리시간 0.037초

Cooling Analysis of Super Precision and Large Stage for OLED

  • Kim, Bo-Seon;Kim, Kug Weon
    • 반도체디스플레이기술학회지
    • /
    • 제17권4호
    • /
    • pp.51-55
    • /
    • 2018
  • As the OLED industry develops, display equipment is becoming larger. As a result, the stage required for display equipment is getting bigger. This enlargement led to increase in OLED production and industrial development. However, due to the large scale of the stage, other problems due to overheating and overheating caused by heavy load on the linear motor, which is mainly used in the stage, must be solved. In this study, a linear motor equipped with a cooling channel is modeled and the three - dimensional heat conduction flow analysis for this model is simulated using Fluent to analyze the cooling efficiency and cooling efficiency according to the cooling water flow rate. As a result, the cooling channel was effective and the cooling effect and efficiency were the best when the flow rate was about 5 ~ 10 L./min. In addition, the cooling effect is increased when the flow rate is increased, but the efficiency is significantly lowered when the flow rate is more than the predetermined value.

간접냉각방식을 이용한 열원이 부착된 채널내의 열전달 촉진에 관한 연구 (The study on heat transfer enhancement using indirect cooling system in the channel with heat source)

  • 김광추;박만흥;윤준규
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.321-331
    • /
    • 1999
  • A numerical study is carried out for increasing heat removal using indirect cooling system. Computation is performed for nine cases as variation of flow condition in the lower channel. As the result of this study, water is more effective than air at the same pressure loss in spite of the lower inlet velocity. In channel configuration, the vertical channel is more effective than horizontal channel because of the buoyancy effect. Under the condition that heat generation is the same, counter flow effectively decreases the temperature difference among blocks. Parallel flow is more effective than counter flow when average temperature of all blocks is considered. In the case of installing obstacles in the lower channel, it is desirable to install obstacles in the bottom of lower channel. Heat transfer rate increases as the height of obstacles increases.

  • PDF

액체로켓 연소기 재생냉각 채널 상온 구조해석 (Structural Analysis of Liquid Rocket Thrust Chamber Regenerative Cooling Channel at Room Temperature)

  • 류철성;정용현;최환석;이동주
    • 한국추진공학회지
    • /
    • 제9권4호
    • /
    • pp.39-47
    • /
    • 2005
  • 재생냉각형 액체로켓 연소기 챔버 냉각 채널부의 상온상태의 구조해석과 검증시험을 수행하였다. 재생냉각 연소기 냉각 채널부에 사용하는 구리 합금의 상온 인장시험을 수행하여 재료의 탄소성 물성 값을 확보하였으며 냉각 채널의 탄-소성해석은 이 물성 값을 이용하여 수행하였다. 해석결과의 검증을 위해서 평판형태의 냉각채널 시편을 제작하여 강도시험을 수행하였다. 탄-소성 구조해석 결과와 시편의 수압시험 결과 사이에 약간의 차이는 있지만 비교적 잘 일치하였으며 채널의 단면 두께가 작기 때문에 제작상의 가공오차가 채널의 구조적인 안정성에 큰 영향을 미치는 것을 확인하였다.

곡선형 형상적응형 냉각채널을 갖는 금형 코어 제작을 위한 DMT 공정개발 (Development of Direct Metal Tooling (DMT) Process for Injection Mold Core with Curved Conformal Cooling Channel)

  • 한지수;유만준;이민규;이윤선;김우성;이호진;김다혜;성지현;차경제
    • 한국기계가공학회지
    • /
    • 제18권11호
    • /
    • pp.103-108
    • /
    • 2019
  • The cooling rate and the uniformity of mold temperature, in the injection molding process, possess great influences on the productivity and quality of replications. The conformal cooling channel, which is of a uniform spacing from the mold cavity by the metal additive manufacturing process, receives much attention recently. The purpose of this study is to develop a mold core with a curved conformal cooling channel for a pottery-shaped thick-wall cosmetic container through the hybrid method of direct metal tooling (DMT) process. In this study, we design a mold core that contains the curved cooling channel for the container. A method that divides the cavity is proposed and the DMT process is carried out to form the curved cooling channel. The test mold core, with the curved conformal cooling channel, has been fabricated by the proposed method to confirm the feasibility of the design concept. We show that no leakage is observed for the additive manufactured test mold core, and its physical properties demonstrate that it can be sufficiently used as the injection mold core.

채널 내 돌출된 열원의 냉각특성 실험 (Experiment on the Cooling Characteristics of Protruding Heat Sources in a Channel)

  • 신지영;손영석;김상민
    • 설비공학논문집
    • /
    • 제16권9호
    • /
    • pp.788-795
    • /
    • 2004
  • Cooling characteristics of protruding heat sources in a parallel channel with or without baffles are studied experimentally, The test section consists of two channels formed by two covers and one board made of polycarbonate which has three uniform heat source blocks. Five different cooling methods are considered to find out the most efficient cooling method in a given geometry and heat sources. The velocity and temperature of cooling medium, the temperature of the block surface are measured. The results are compared to examine the cooling characteristics of the different cooling methods.

돌출된 열원이 있는 채널에서 대류와 전도열전달을 이용한 냉각특성 (Cooling Characteristics of a Parallel Channel with Protruding Heat Sources Using Convection and Conduction Heat Transfer)

  • 손영석;신지영
    • 설비공학논문집
    • /
    • 제14권11호
    • /
    • pp.923-930
    • /
    • 2002
  • Cooling characteristics of a parallel channel with protruding heat sources using convection and conduction heat transfer are studied numerically. A two-dimensional model has been developed for numerical prediction of transient, compressible, viscous, laminar flow, and conjugate heat transfer between parallel plates with uniform block heat sources. The finite volume method is used to solve the problem. The assembly consists of two channels formed by two covers and one printed circuit board which has three uniform heat source blocks. Six different cooling methods are considered to find out the most efficient cooling method in a given geometry and heat sources. The velocity and temperature fields of cooling medium, the temperature distribution along the block surface, and the maximum temperature in each block are obtained. The results are compared to examine the cooling characteristics of the different cooling methods.

압력감응페인트를 이용한 확대/축소 유로에서의 막냉각 효율 측정 (Measurement of the Film Cooling Effectiveness using Pressure Sensitive Paint on Convergent/Divergent Channel)

  • 박승덕;이기선;김성하;김학봉;곽재수;김춘택;양계병
    • 한국유체기계학회 논문집
    • /
    • 제11권6호
    • /
    • pp.31-37
    • /
    • 2008
  • Film cooling effectiveness on the convergent or divergent channel was measured by pressure sensitive paint technique. The channel convergent or divergent angle was changed from $-5^{\circ}$ to $10^{\circ}$ and the tested blowing ratios were 0.5, 1 and 2. Results showed that the film cooling effectiveness on the convergent channel was not much affected by the convergent angle. With divergent film cooled surface, the film cooling effectiveness near the injection hole decreased as the divergent angle increases. However, the film cooling effectiveness at far downstream from the hole showed opposite trend. For the non-film cooled surface inclined case, the film cooling effectiveness was not much affected by the divergent angle.

곡선형 냉각채널 금형을 사용한 프론트 필라 핫스탬핑 공정에서 금형냉각시간이 기계적 특성에 미치는 영향 (Effect of Die Cooling Time on Component Mechanical Properties in a Front Pillar Hot Stamping Process)

  • 이재진;강다경;서창희;임용희;이경훈;한수식
    • 한국기계가공학회지
    • /
    • 제18권6호
    • /
    • pp.33-38
    • /
    • 2019
  • Researchers have recently begun to study hot stamping processes to shorten the mold cooling time and improve productivity. These publications explain that the mold cooling time can be reduced by using a curved cooling channel, where the mold surface is processed to a uniform depth, instead of a straight cooling channel that uses the conventional gun drilling machine. This study investigates the characteristics of the front pillar of an automobile after using a mold with a curved cooling channel. To analyze the change in properties, we used a 1.6 mm boron steel blank and heated the prototype at $930^{\circ}C$ for 5 minutes. Next, we formed the prototype with a load of about 500 tons while varying the mold cooling time between 1 and 10 seconds. We subjected each prototype specimen to a tensile strength test, a hardness test, and a tissue surface observation.

사출성형금형에서 직선채널과 배플의 냉각효율 비교 (Comparison of Linear Channel and Baffle for Cooling Rate in Injection Mold)

  • 문영배;최윤식;정영득
    • Design & Manufacturing
    • /
    • 제6권1호
    • /
    • pp.1-4
    • /
    • 2012
  • Plastic products are producted more than 70% of total processes in the injection molding. The injection molding process has 4 processes such as filling, packing, cooling and ejecting. It spends most of times in the cooling process. Therefore, it is important to control the mold temperature in producing plastic products. The time and system of cooling affect the product's quality and productivity. Especially, cooling time has about 60% of total injection cycle time. Therefore, we can improve a productivity by shortening cooling time. In this study, it was made a comparative study about cooling of linear channels and baffles and observed the variation of mold temperature on the coolant's temperature. As the result, the linear channel's cooling rate had faster than baffles and as coolant's temperature was increased, difference of cooling time was increased. Result of this study will be used widely to design for cooling system of injection mold.

  • PDF