Implementation of Linear Motor Piston Amplitude Estimator Using Phase Lag Filter (위상지연필터를 이용한 리니어 모터 피스톤 진폭 추정기의 구현)

  • Oh, Joon-Tae;Kim, Gyu-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.4
    • /
    • pp.212-218
    • /
    • 2013
  • In this paper, a linear motor piston amplitude estimator using phase lag filter has been implemented. In order to control the cooling capability of a refrigerator or an air conditioner in which liner compressors are applied, the piston speed should be controlled. The piston speed control can be obtained by adjusting the frequency or the stroke of linear motors. The dynamic performance of linear compressors depends on how accurately the stroke or the piston amplitude is estimated. A linear motor piston amplitude estimator using phase lag filter is proposed and the superior performance of our estimator is verified via some simulation studies.

Performance Evaluation of Light-Shelf based on Light Enviorment and Air Conditioner Enviorment (빛환경 및 냉난방환경 기반 광선반 성능평가 연구)

  • Jeon, Gangmin;Lee, Heangwoo;Seo, Janghoo;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.16 no.5
    • /
    • pp.47-55
    • /
    • 2016
  • Purpose: As the energy consumed by buildings increases, there is a growing need for studies and technology development to address this issue. One of the solutions to excessive energy use by buildings is the light-shelf, which is a natural lighting system enabling efficient reduction in light energy, and research in this area has been intensive. However, most of the studies about the light-shelf are limited to the light environment, and thus the application of their findings to an actual environment in the form of a design may be problematic. Therefore, the purpose of the present study is to provide fundamental data for light-shelf design by carrying out a light-shelf performance evaluation on the basis of the light environment and the heating and cooling environment. Method: In the present study, a testbed was established to conduct a light-shelf performance evaluation by measuring the electric power consumption of lighting and heating and cooling devices depending on the existence of a light-shelf and its angle. Result: The findings of the present study are as follows: 1) With respect to the uniformity of the indoor light environment amenity, the optimum angle of a light-shelf was found to be $30^{\circ}$ for the summer solstice and the winter solstice. 2) With respect to the reduction of electric power consumption by indoor lighting devices, the optimum light-shelf angle at the summer solstice is $30^{\circ}$, at which time electric power consumption may be reduced by 10.2% in comparison with when no light-shelf is applied. However, at the winter solstice, a light-shelf may increase the energy consumption for lighting in comparison with when no light-shelf is applied, and this should be taken into account in the design of a light-shelf. 3) In terms of reducing the electric power consumption of heating and cooling devices, the optimum angle of a light-shelf was found to be $30^{\circ}$ for the summer solstice, while a light-shelf is inappropriate for the winter solstice since a light-shelf creates shade and thus increases the heating energy consumption. 4) To summarize the findings above, the optimum angle of a light-shelf is $30^{\circ}$ for the summer solstice, but the installation of a light-shelf may in some circumstances increase the energy consumed by lighting devices as well as by heating and cooling devices. Therefore, more studies and technology development may need to be performed to solve the problem of increased energy consumption at the winter solstice.

An Experimental and Numerical Analysis on Performance Comparison of a Trigeneration Desiccant System and Conventional Air-conditioning System (Trigeneration 제습공조시스템과 일반공조시스템의 성능 비교 실험 및 수치해석)

  • Kim, Hyoung-Tae;Chae, Jungmin;Cho, Young-Ah;Park, So-jin;Song, Geun-Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.3
    • /
    • pp.32-37
    • /
    • 2018
  • Recently, the distributed power generation market using natural gas is expected to expand gradually according to the government's future energy conversion policy. Distributed power generation means small power generation source near the power demand site, which has the advantage of reducing the construction costs of the transmission and distribution infrastructure, operating cost and power loss. A typical example of distributed generation using natural gas is the trigeneration system. In this study, we conducted a basic study on the performance analysis of trigeneration desiccant system for dehumidifying / cooling / heating in the air conditioner room by using the cold and engine waste heat energy generated in the trigeneration system. It shows that the system efficiency increases and the energy consumption decreases as the temperature difference between the inlet and outlet of the trigeneration system increases compared with the general air conditioning system.

Effects of geometric conditions of blade on Performance of Axial Pan (익형의 기하학적 조건에 따른 축류팬의 성능에 관한 연구)

  • Ahn E. Y.;Kim J. W.;Jeongng E. J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.25-29
    • /
    • 2005
  • Axial fan is used for the supplement of large amount of flows. Axial blowers show relatively high efficiency of the system. The present model of axial fan is for cooling a condenser in an air-conditioning unit that exhibits tendency toward compact size. In order to realize the compact model, the width of an axial blade should be cut down in axial distance. Main interest lies on the performance of the axial blowing system with blades having shorter chord length. One of the important design parameters for axial fan is the shape of the blades of it. Design of blades includes the cross-sectional shape and its dimension, including the chord length. We consider two types of blades; one is NACA airfoil with normal chord length and the other is with shortening chord length by $10\%$ of normal airfoil. Axial blower with the modified blades is essential for the compact model of an air-conditioner. The other design parameters are same in the two cases. Using a wind tunnel follows ASHRAE standards carries out evaluation of performance of the system. Detail of flows around the blades is prepared by velocity measurements using PIV. According to performance estimation, the axial blower with short chord blade show quite close to the performance results, including flow rate and pressure rise, of the standard one. The reason of the two similar results is that the flowpatterns depend on Reynolds number based on the chord length of a blade. In this investigation, the critical chord length is found, in which the flows near the airfoil are so unstable and the performance of the system is decreased. A series of figures is for the detail information on the flow.

  • PDF

Design of Data Warehouse System for Reducing Defect Rate in Automotive Pulley Manufacturing Process (자동차 풀리 제조공정의 불량률 감소를 위한 데이터 웨어하우스 구조 설계)

  • Lee G.B.;Kim B.H.;Oh B.H.;Ju I.S.;Jang J.D.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.133-138
    • /
    • 2005
  • Automotive pulleys play a key role in driving the cooling pump, oil pump, air-conditioner and so on by using an engine power. Researches on design processes and technologies of the pulleys can be found in many literatures. On the other hand, the areas related to manufacturing processes of the pulleys have been treated negligently. Vast data extracted from various information systems are transformed, integrated, and summarized to become a special database for helping users make a decision. The database, namely the data warehouse has been popularly used in the marketing and customer management of enterprises and recently applied to improve the design and manufacturing processes. In this study the manufacturing process of pulleys were analyzed through the intensive investigation of shop-floors and the interviews with workers and managers. The defects generated during a manufacturing process were categorized in a few types and the causes of defects examined for extracting the dominant parameters in the setup process for producing pulleys. As the first step to construct the data warehouse for the manufacturing processes of pulleys, authors proposed its architecture focused on the reduction of defect rate during the setup process.

  • PDF

Implementation of Position Sensorless Stroke Controller of Linear Compressors with Motor Parameter Identification (매개변수 추정기를 갖는 리니어 컴프레서의 위치센서리스 스트로크 제어기 구현)

  • Kim, Kwang-Ho;Nam, Jae-Woo;Kim, Gyu-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.10
    • /
    • pp.173-179
    • /
    • 2014
  • In this paper, a motor parameter identification system has been implemented to improve the performance of the position sensorless stroke controller for linear compressors. In order to control the cooling capability of a refrigerator or an air conditioner in which linear compressors are applied, the piston speed should be controlled. The piston speed control can be obtained by adjusting the frequency or the stroke of linear motors. The dynamic performance of linear compressors depends on how accurately the stroke or the piston amplitude is estimated. The merits and demerits of Constant method and PIM (Parameter Identification Method) concerning the needed memory space and the stroke error are discussed and verified via some experimental studies.

A Study of Dynamic Performance Improvement of Linear Compressors Using Phase Control Loop (리니어 컴프레서의 위상제어를 통한 동특성 향상에 관한 연구)

  • Nam, Jae-Woo;Oh, Joon-Tae;Kim, Gyu-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.3
    • /
    • pp.156-163
    • /
    • 2014
  • In this paper, a phase control system has been implemented to improve the dynamic performance of the stroke response for linear compressors. In order to control the cooling capability of a refrigerator or an air conditioner in which liner compressors are applied, the piston speed should be controlled. The piston speed control can be obtained by adjusting the frequency or the stroke of linear motors. The dynamic performance of linear compressors depends on how accurately the stroke or the piston amplitude is estimated. A phase control system is added to the stroke control loop and the superior performance of the phase control system is verified via some simulation studies.

Analysis of Actual State of Facilities for Pleurotus eryngii Cultivation - Based on Western Gyeongnam Area - (큰느타리버섯 재배사의 실태분석 - 서부경남지역을 중심으로 -)

  • Yoon Yong Cheol;Suh Won Myung;Yu Chan
    • Journal of Bio-Environment Control
    • /
    • v.13 no.4
    • /
    • pp.217-225
    • /
    • 2004
  • This study was performed to provide the basic knowledge about the mushroom cultivation facilities. Classified current status of cultivation facilities in Gyeongnam province was investigated by questionnaire. The structure of Pleurotus eryngii cultivation facilities can be classified into the simple and permanent frame type. The simple frame structures were mostly single-span type, on the other hand, the permanent frame structures were more multi-span than simple structures. And the scale of cultivation facilities was very different regardless of structural type. But as a whole, the length, width and ridge height were prevailing approximately 20.0 m, $6.6\~7.0m$ and $4.6\~5.0m$ range, respectively. The floor area was about $132\~160\;m^2$, and floor was built with concrete to protect mushrooms from various harmful infection. The roof slope of the simple and permanent type showed about $41.5^{\circ}\;and\;18.6\~28.6^{\circ}$, respectively. The width and layer number of growing bed for mushroom cultivation were around $1.2\~1.6m$, 4 layers in common, respectively. Most of year round cultivation facilities were equipped with cooler, heater, humidifier, and ventilating fan. Hot water boiler was the most commonly used heating system, the next was electric heater and then steam boiler. The industrial air conditioner has been widely used for cooling. And humidity was controlled mostly by ultra-wave or centrifuging humidifier. But some farmers has been using nozzle system for auxiliary purpose. More then $90\%$ of the mushroom house had the independent environment control system. The inside temperature was usually controlled by sensor, but humidity and $CO_2$ concentration was controlled by timer for each growing stage. The capacity of medium bottle was generally 850 cc and 1100cc, some farms used 800 cc, 950 co and 1,250 cc. Most of mushroom producted has been usually shipped to both circulating company and joint market.