• 제목/요약/키워드: Cooling and Heating Loads

검색결과 139건 처리시간 0.027초

용접이음 된 유압 실린더용 로드/너클 조립체의 피로거동 해석 (Fatigue Behavior Analysis of Welded Rod/Knuckle Assembly for Hydraulic Cylinder)

  • 이환우
    • 한국기계가공학회지
    • /
    • 제12권4호
    • /
    • pp.93-99
    • /
    • 2013
  • Parts and structures such as piston rod and knuckle joint for the use of hydraulic cylinder are often welded together in some fashion, usually due to cost and process effectiveness. Welding strongly affects the material by the process of heating and subsequent cooling as well as by the fusion process with additional filler material. Furthermore, a weld is usually far from being perfect, containing inclusions, pores, cavities, undercuts etc. As a consequence, fatigue failures appear in welded structures mostly at the welds rather than in the base metal, even if the latter contains notches. For this reason, fatigue analyses are of high practical interest for all welded structures under the action of cyclic loads. This paper describes the influence of welding parameters, material combinations and heat treatment on the fatigue behavior of welded cylinder rod. In addition, statistical characterization of stress-life response in weldment of hydraulic cylinder rod are presented.

건물 단지에 대한 에너지 수요 예측 데이터베이스 응용 프로그램 개발 (Development of a Energy Demand Estimator for Community Energy Systems)

  • 정모;박화춘
    • 한국태양에너지학회 논문집
    • /
    • 제29권3호
    • /
    • pp.37-44
    • /
    • 2009
  • The field-surveyed and measured energy consumption data is processed to develop building energy demand models for heating, hot water, cooling, and electricity. The load models are systematically organized as a database and hourly loads for a span of year (8760 hours) are generated by the program. Rased on those models a Microsoft Access application program is developed to calculate energy demands for a Community Energy System (CES) composed of 17 types of buildings. User-friendly interfaces are provided to assist non-expert end users and necessary tools to link the calculation results to subsequent coagulations such as operation simulation or economic assessment.

건물 단지에 대한 에너지 수요 예측 프로그램 개발 (Development of a Building Energy Demand Estimator)

  • 정모;박화춘;임용훈
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.127-132
    • /
    • 2009
  • A Microsoft Access application program is developed to calculate energy demands for a Community Energy System (CES) composed of various types of buildings. The field-measured heating, hot water, cooling, and electricity energy consumptions for 14 types of building are systematically organized in forms of database and hourly loads for a span of year (8760 hours) are generated through an automated statistical procedure. User-friendly standard windows interfaces are provided to assist non-expert end users.

  • PDF

구미지역의 지중온도예측 방법에 관한 연구 (A Study on the Method to Predict Underground Temperature in Gumi City)

  • 정수일
    • 한국주거학회논문집
    • /
    • 제13권4호
    • /
    • pp.27-33
    • /
    • 2002
  • In Gumi area, the heating and cooling loads for underground building could have not been correctly evaluated since there were no systems accurate underground temperature. For solving this problem two ways of predicting the underground temperature were propose. Firstly, it is to estimate the underground temperature of Gumi area by averaging out the underground temperature of the areas around Gumi city. However, the underground temperature data of the areas around Gumi city was only limited to 0.5m and 1.0m under the ground. Secondly, it is to calculate the underground temperature of Gumi area by using a periodic equation with variable about underground properties. Among these methods, the method of the average date was more correct, but the method of the variable date was more available.

경량 복합패널을 활용한 구호주거의 횡하중 저항성능 및 냉난방조명 에너지성능 평가 (Evaluation of Lateral Load Resistance and Heating/Cooling/Lighting Energy Performance of a Post-disaster Refugees Housing Using Lightweight composite Panels)

  • 황문영;이병연;강수민;김성태
    • 한국산학기술학회논문지
    • /
    • 제20권3호
    • /
    • pp.252-262
    • /
    • 2019
  • 2016년 경주 지진에 이어 2017년 포항 지진까지 발생한 대한민국은 더 이상 지진에 대해 안전지대라고 할 수 없다. 이에 따라 재난환경에 적합한 피난시설의 필요성이 증대되고 있다. 본 연구에서는 경량 복합패널을 이용하여 기존 피난시설의 단점들을 보완할 수 있는 구호주거를 제작하고자 하였다. 이를 위해 경량 복합패널로 구성된 구호주거에 대한 구조 성능과 에너지성능을 평가하고자 하였다. 구호주거의 구조 성능을 평가하기 위해 경량 복합패널로 제작한 시스템에 대한 횡하중가력 실험을 진행하였다. 실험체는 접합 방식을 변수로 하여 2가지로 구성하였다. 또한 KBC 2016에 따라 실험체에 대한 지진하중과 풍하중을 산정하여 실험 결과와 비교하였다. 에너지성능은 냉난방 및 조명에너지 사용량을 최소화하기 위해 기준 패널을 활용한 남측창호 최적화기법을 활용하여 분석하였고, 창면적비, 창 총일사취득율 최적화를 진행하였다. 결과적으로 경량 복합패널로 제작된 실험체는 횡하중에 대해 충분히 안전한 성능을 보일 것으로 판단되며, 창면적비 0.38, 총일사취득율 0.5수준의 최적화 계획을 통한 저에너지 운용이 기대된다.

차양형 BIPV가 적용된 사무소 건물의 외피 최적 설계에 관한 연구 (A Study on the Optimum Design of a Facade with Shading-type BIPV in Office Building)

  • 박세현;강준구;방아영;김준태
    • 한국태양에너지학회 논문집
    • /
    • 제35권2호
    • /
    • pp.93-101
    • /
    • 2015
  • Zero energy building is a self sufficient building that minimizes energy consumption through passive elements such as insulation, high performance window system and installing of high efficiency HVAC system and uses renewable energy sources. The Korea Government has been strengthening the building energy efficiency standard and code for zero energy building. The building energy performance is determined by the performance of building envelope. Therefore it is important to optimize facade design such as insulation, window properties and shading, that affect the heating and cooling loads. In particular, shading devices are necessary to reduce the cooling load in summer season. Meanwhile, BIPV shading system functions as a renewable energy technology applied in solar control facade system to reduce cooling load and produce electricity simultaneously. Therefore, when installing the BIPV shading system, the length of shadings and angle that affect the electricity production must be considered. This study focused on the facade design applied with BIPV shading system for maximizing energy saving of the selected standard building. The impact of changing insulation on roof and walls, window properties and length of BIPV shading device on energy performance of the building were investigated. In conclusion, energy consumption and electricity production were analyzed based on building energy simulations using energyplus 8.1 building simulation program and jEPlus+EA optimization tool.

지속가능한 도시개발을 위한 LID평가모델(LIDMOD)개발과 수질오염총량제에 대한 적용성 평가 (LIDMOD Development for Evaluating Low Impact Development and Its Applicability to Total Maximum Daily Loads)

  • 전지홍;최동혁;김태동
    • 한국물환경학회지
    • /
    • 제25권1호
    • /
    • pp.58-68
    • /
    • 2009
  • Low impact development (LID) technique is relatively new concept to reduce surface runoff and pollutant loading from land cover by attempting to match predevelopment condition with various integrated management practices (IMPs). In this study, computational model for designing and evaluating LID, named LIDMOD, was developed based on SCS-CN method and applied at Andong bus terminal to evaluate LID applicapability and design retention/detention area for volume or peak flow control. LIDMOD simulated with 21 years simulation period that yearly surface runoff by post-development without LID was significantly higher than that with LID showing about 2.8 times and LID could reduce efficiently yearly surface runoff with 75% reduction of increased runoff by conventional post development. LIDMOD designed detention area for volume/peak flow control with 20.2% of total area by hybrid design. LID can also efficiently reduce pollutant load from land cover. Pollutant loads from post-development without LID was much higher than those from pre-development with showing 37 times for BOD, 2 times for TN, and 9 times for TP. Pollutant loads from post-development with LID represented about 57% of those without LID. Increasing groundwater recharge reducing cooling and heating fee, creating green refuge at building area can be considered as additional benefits of LID. At the point of reducing runoff and pollutant load, LID might be important technique for Korean TMDL and LIDMOD can be useful tool to calculate unit load for the case of LID application.

도시기반 에너지공급시스템의 최적화 방안 연구 (A Study on the Optimal Design of Urban Energy Supply Systems)

  • 김용기;이태원;우남섭
    • 대한기계학회논문집B
    • /
    • 제33권6호
    • /
    • pp.396-402
    • /
    • 2009
  • Recently many efforts have been carried out on the development of energy-efficient and environment-friendly systems in order to preserve natural environment and to reduce environmental loads in the branch of the urban planning and the building design. In this study, a mathematical method was developed and a numerical analysis was carried out with various parameters to provide substantial data for optimal design and operation of urban energy supply systems. Components of the system and their specifications, such as a co-generation system and other heating and cooling systems, could be obtained through this analysis for various resource and energy requirements in urban area. In this study, the system constituents and operating characteristics, and their economic performances such as the value of objective function, the amount of energy consumption were discussed for various load patterns and power load ratios. Also, it turns out that the optimal energy supply system can save energy by $10{\sim}20%$ in comparison with the conventional energy supply system.

다목적 복합건물의 하절기 열원기기 운전시 소비전력에 관한 시뮬레이션 (Simulation on Energy Consumption in the Summer Season Operation of primary HVAC system for Multipurpose Building Complex)

  • 서재경;최승길;강채동
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.903-908
    • /
    • 2006
  • Building energy simulation has become a useful tool for predicting cooling, heating and air-conditioning loads for facilities. It is important to provide building energy performances feed back to the mechanical and electrical system operator and engineer for energy conservation and maintenance of building. From this research, we set up the typical weather data of location, basic description of building, geometric modelling data and the specification of Installed primary HVAC system for establishing the simulation model about energy consuming that take place in multipurpose building complex. The simulation tool of building energy - EnergyPlus (DOE and BLAST based simulation S/W), it has been used and accomplished calculations and analyses for evaluating the effect of the system types and operating condition of central HVAC plant on the building energy consumption. In this paper, we offer comparison and simultaneous results those involve electricity consumption pattern and amount between actual operation versus EnergyPlus simulation to the object building during summer season.

  • PDF

육상 수조식 양식장의 해수 열원 히트펌프 시스템 적용을 위한 열부하 분석 (Thermal load analysis of tank culture system for applying seawater source heat pump)

  • 윤민기;김태훈;정석권
    • 수산해양기술연구
    • /
    • 제59권2호
    • /
    • pp.155-163
    • /
    • 2023
  • This study deals with the maximum thermal load analysis and optimal capacity determination method of tank culture system for applying seawater source heat pump to save energy and realize zero energy. The location of the fish farm was divided into four sea areas, and the heat load in summer and winter was analyzed, respectively. In addition, two representative methods, the flow-through aquaculture system and the recirculation aquaculture system were reviewed as water treatment methods for fish farms. In addition, the concept of the exchange rate was introduced to obtain the maximum heat load of the fish farms. Finally, power consumption for heat pumps was analyzed in the view point of sea areas, tank capacity, and exchange rate based on the calculated maximum thermal load.