• 제목/요약/키워드: Cooling and Heating

검색결과 1,915건 처리시간 0.031초

도심 임대아파트의 에너지 및 상수 소비 특성에 관한 연구 (An Analysis on the Characteristics of Energy and Water Consumption in Urban Rental Apartment)

  • 서윤규;김주영;홍원화
    • 한국주거학회논문집
    • /
    • 제20권6호
    • /
    • pp.39-46
    • /
    • 2009
  • It has been a serious problem to consume the energy of apartment while increasing to use of heating & cooling System because of residence environmental upgrades. Great attention has been shown to the problem of the rental apartment, so there are few reports of energy consumption about the rental apartment in korea. To solve the lack of housing, our country has supplied an enormous volume of apartments, and these days it occupies 75% of our buildings. As apartments occupy most of our housings, the rate of energy usage from them are also high. On this, setting apartment energy reduction as a target, by researching the actual conditions of energy consumption and drawing a basis data, we can apply this as a way of saving energy, rationalization of the scale of energy supply facilities and a standard when planning facilities. To grasp the present condition of energy usage of the urban rental apartment, this research analysed the use of electricity, gas and water monthly and annually of a rental apartment that is located in Daegu. The results showed that in 2003 the electricity usage was 1,198MWh but 1,315MWh in 2007, which means 9% of electricity usage increases every year. The average of water usage was $85,072\;m^2$ per year and typical energy consumption unit was $604.2\;MJ/m^2$ on $74.4\;m^2$ of area and $448.8\;MJ/m^2$ on $105.8\;M^2$. By showing the usage of energy and water of the urban rental apartment, understanding the tendency and preparing an typical energy consumption unit standard through this research, apartments should use energy more efficiently.

국내외 녹색건축인증에서의 커미셔닝 평가기준에 대한 비교 연구 (A Comparative Study on Domestic and International Evaluation Criteria of Commissioning for Sustainable Building Certification)

  • 정다훈;정찬우
    • 한국건설관리학회논문집
    • /
    • 제18권1호
    • /
    • pp.27-36
    • /
    • 2017
  • 국토교통부는 녹색건축물 조성을 촉진하기 위해 '17년 공동주택은 냉,난방 에너지 90%('90년 대비) 절감 목표를 수립하였으며, 2015년 UN 기후변화회의(2015 United Nations Climate Change Conference)에서 당국은 2030년 배출전망 (BAU)인 8억 5060만 ton $CO^2$ 대비 37%를 감축하겠다고 발표하였다. 이를 만족하기 위해서는 가장 많은 탄소 발생을 야기하는 건축물에서 탄소배출 최소화를 위한 조치가 시급하며, 이에 건물 사용 시 발생하는 탄소배출 감축을 위해 필요한 건물 성능 강화를 유도하는 커미셔닝에 대한 관심이 높아지고 있다. 그러나 현재 건설업계에서 커미셔닝은 법제화되어 있지 않고 건설 참여자의 수행의지 및 효과 홍보 부족으로 인해 활성화 되어있지 않다. 또한, 녹색건축으로의 인증을 획득하는 과정에서 조차 커미셔닝은 필수 수행 항목으로 지정되어 있지 않아 국내 커미셔닝은 그 효과 대비 저평가 받고 있는 실정이다. 이에, 본 연구에서는 커미셔닝의 효과에 대해 기술하고, 해외 녹색건축인증 LEED, BREEAM을 기준으로 커미셔닝이 녹색건축에 있어서 어떻게 평가받고 있는지 국내 G-SEED와 비교, 분석하여 국내 녹색건축인증에서의 커미셔닝 필수화를 제안하고 나아가 커미셔닝이 국내에서 활성화 될 수 있도록 건설 주체자의 인식 변화를 유도하고자 한다.

서울지역 학교 영양(교)사의 PHF에 대한 인식 및 CCP 관리기준 수행실태 조사 - HACCP 시스템 CCP 3~CCP 7을 중심으로 - (Research Study on Seoul Region School Nutritionists' Perception of Potentially Hazardous Foods and Execution Conditions of Managing CCP Control Standard of the HACCP System - Focusing on CCP 3~CCP 7 -)

  • 이애랑
    • 동아시아식생활학회지
    • /
    • 제26권6호
    • /
    • pp.517-530
    • /
    • 2016
  • This research was conducted on Seoul region elementary, middle, and high school nutritionists to analyze execution conditions of HACCP control standards, focusing on PHF and CCP 3~CCP 7, in order to determine more efficient methods for school meals' sanitation system settlement. All surveys were distributed and collected via email. A total of 305 survey papers were collected, and 300 school results were analyzed. The following percentage of nutritionists perceived the following foods as potentially hazardous foods(PHF): raw or cooked animal foods (94.7%), blossomed seed products (93.7%), packed pickled radish (36.7%), unopened mayonnaise (30.2%), and unopened snails & corn cans 54.8%. Exactly 51.2% of nutritionists believed that foods were properly supplied via CCP 3's food quality standard. Exactly 33.9% of nutritionists answered that they had never corrected the digital thermometer since there were no issues with the CCP 4's digital thermometer correction frequency level. As for CCP 5's chroline disinfection of green vegetables, 57.1% of nutritionists answered that vegetables were slightly softened while 36.2% said there were no changes at all. According to the nutritionists, the most difficult execution level of CCP levels (excluding CCP 3, CCP 4) was CCP 7 (37.1%), CCP 6 (16.4%), and CCP 2 (16.4%). For the above results, proper training/education must be enforced so that nutritionists can have a clear notion of the PHF. A solution must be developed enhancing the execution of CCP 4's digital thermometer correction frequency level. For CP 5's chroline disinfection of green vegetables, food characteristics must be considered to suggest an appropriate number and method of cleansing. Furthermore, cooking employees are needed that properly use and manage cooling & heating equipments to maintain heated foods above $57^{\circ}C$ under the CCP 7 standard.

부분 스위칭 PFC 모듈을 이용한 가정용 에어컨 전원장치 (The Power System for Home Appliance Air-Conditioner using Partial Switching Power Factor Correction Module)

  • 서기영;문상필
    • 조명전기설비학회논문지
    • /
    • 제18권6호
    • /
    • pp.183-190
    • /
    • 2004
  • 본 논문은 냉난방 인버터 에어컨용 전원시스템에 역률개선 회로인 부분 스위칭 PFC 모듈을 적용하여 입력의 역률 개선 및 전류의 고조파 성분을 최소화하여 IEC555-2규정을 만족하는 입력 전원부를 설계하여 인덕터부하에 적용되는 회로 설계시의 문제점들을 해결 할 수 있는 방안들을 제시하였다. 그리고 출력전압의 상승을 억제하면서 전류파형을 개선하는 방법 및 부분 스위칭 PFC회로를 제안하여 스위칭 횟수를 적게 함으로써 압축기의 모터에 인가 할 수 있는 전압을 상승시켜 모터 적정 운전 전압을 확립하였으며, 효율이나 경제성 및 전자 노이즈 등의 문제점들을 해결하였다. 그리고 에어컨의 소비 전력을 줄일 수 있다. 이상의 결과에서 시스템 총합 운전에너지 효율이 상승되는 것을 확인하는 모든 사항은 시뮬레이션과 실험을 통하여 그 타당성을 입증했다.

흡수열펌프에서 흡수기의 성능 개선 연구 (A Study on Improvement of Performance of Absorber in Absorption Heat Pump)

  • 민병훈
    • 공업화학
    • /
    • 제19권3호
    • /
    • pp.338-344
    • /
    • 2008
  • 냉 난방 수요에서 일어나는 환경오염의 최소화와 화석연료 소비를 감소시키기 위해서 에너지보존을 개선시키는 것은 필수적이다. 이러한 점에서 흡수식 열펌프기술은 에너지 절약을 위해서 많은 가능성을 가지고 있다. 흡수식 열펌프는 에너지를 주입하지 않고 폐열의 이용을 높일 수 있는 방법이다. 흡수식 열펌프는 흡수기에서 흡수된 양의 증가가 매우 중요하기 때문에 흡수기 성능이 매우 중요하다. 본 연구에서는 흡수기의 성능을 개선시키기 위해서 메탄올과 글리세린을 작동유체로 하는 내벽에 나선형관을 설치하여 액상을 접선방향으로 공급하는 흡수기에 관한 연구를 수행하였다. 이 방법은 액상흐름에서 난류를 일으켜 물질 및 열전달을 증가시킨다. 흡수기의 각 위치에서 온도와 농도를 측정하여 열전달계수와 물질전달계수를 계산하였고 주입부분에서 열 및 물질전달이 향상되었음을 알 수 있었다.

급·배기 일체형 디퓨저의 환기 및 온열환경 유지성능에 대한 연구 (A Study on The Performance of Ventilation and Maintaining Thermal Environment for a Combined Type Diffuser)

  • 임석영;장현재
    • 설비공학논문집
    • /
    • 제28권6호
    • /
    • pp.232-241
    • /
    • 2016
  • Installing a ventilator for an apartment house composed of over 100 dwelling units was mandated in 2006 to improve indoor air quality. In the case of mechanical ventilators, the air change rate is kept stable, however 68% of dwellers do not operate their ventilator because of an increased electrical bill and noise. In the case of natural ventilators, the former problems are settled, but there are concerns about cold draught and an increase of heating/cooling cost. Authors are developing a heat recovery type natural ventilator which is a natural ventilator equipped with total heat recovery element, and it is expected that those problems of mechanical ventilator and natural ventilator are resolved by this. The combined type diffuser of this study is an under developed fit to the heat recovery type natural ventilator above. There are no standards to evaluate the performance for this type of diffuser. Due to this issue this study investigated the performance of the ventilation and maintained a thermal environment for the combined type diffuser by comparing it with existing diffusers. The results revealed that the performances of the combined type of diffusers showed different features from the existing ones, and was estimated to be high enough in the performances above.

하이브리드 발전 시스템을 적용한 이동식 하우스 (Transportable House with Hybrid Power Generation System)

  • 박미정;주종율;김응곤
    • 한국전자통신학회논문지
    • /
    • 제18권1호
    • /
    • pp.205-212
    • /
    • 2023
  • 현대사회는 화석연료 등의 사용으로 기후변화로 인한 기상이변이 전 세계가 이례적인 피해가 속출하고, 코로나와 같은 전염병이 인간에게 더욱 생활의 질이 악화되고 있는 실정이다. 온실가스를 줄이고 신재생에너지 사용이 시급한 현실이다. 화석연료의 사용을 줄이고 신재생에너지 사용으로 지구환경 오염을 줄이고자 한다. 본 논문에서는 태양광을 이용해 지능형 CCTV 및 인터넷 WiFi, 냉난방 시스템을 통한 사계절 환경과 안전 및 통신 기능이 가능하고, 스마트폰 앱을 통한 태양광의 생산량과 소비량을 실시간으로 모니터링하여 최적화된 전력관리를 할 수 있는 시스템을 제안한다. 태양광 발전 시스템을 사용할 수 없는 한파, 태풍, 자연재해 등의 계통 정전과 같은 비상시 끊김 없는 디젤 발전을 지원하는 하이브리드 발전시스템을 제안한다.

지열 열펌프 및 태양광 발전 적용이 비주거용 건물의 에너지효율등급과 ZEB 인증 등급에 미치는 영향 (The Effect of a Geothermal Heat Pump and Photovoltaics Application on the Building Energy Efficiency and ZEB Certification Rating for a Non-Residential Building)

  • 문건호;박창용
    • 한국지열·수열에너지학회논문집
    • /
    • 제19권1호
    • /
    • pp.1-13
    • /
    • 2023
  • Many government in the world have conducted building energy performance certification program to reduce building energy consumption. In this study, a reference building and its HVAC system was modeled, and the energy load and consumption were estimated by the ECO2 program. The software is a simple building energy simulation program based on monthly calculated method. The building energy efficiency rating the the reference building was 1+ under baseline condition. The simulation results showed that the insulation performance slightly affected building energy load and consumption, but light density had a significant effect on them. The application of geothermal heat pumps gave improvement of building energy efficiency rating but it could not make it possible to get zero energy building(ZEB) certification. The ZEB 5 certification could be achieved by using photovoltaics, however getting better grade was difficult. The simulation results showed that the ZEB 4 certification, one grade higher than ZEB 5, could be attained by using more than one renewable energy source such as geothermal and solar energy in this study.

단일심정 지열히트펌프의 수치적 모델링 Part I: 수치해석 모델 검증 (Numerical Simulation of Standing Column Well Ground Heat Pump System Part 1: Validation of the Numerical Model)

  • 박두희;김광균;곽동엽;장재훈;박시삼
    • 한국지반공학회논문집
    • /
    • 제26권2호
    • /
    • pp.33-43
    • /
    • 2010
  • 지열은 고효율 신재생에너지로 각광을 받고 있으며 건축물의 냉난방 설비 시스템으로 활용이 점차 확산되고 있다. 지열 히트펌프 중에서 지하수를 열원으로 사용하는 단일심정(Standing column well)은 특히 효율이 높고 초기설치비용이 저렴하며 국내 지반 수리조건에 적합하다. 반면, 국내에는 아직 SCW의 성능을 평가할 수 있는 수치해석 모델이 없으며 국내 자료를 적용한 수치해석이 수행된 바 없다. 본 연구에서는 SCW 수치해석 모델을 유한체적해석 프로그램을 이용하여 구축하였다. 수치적 모델은 수리 열 연계해석을 수행하여 열이류, 대류, 전도를 모두 모사한다. SCW 모델은 미국과 국내에서 계측된 현장 데이터를 통하여 검증하였다. 비교 결과 본 연구에서 구축된 수치해석 모델은 정확하게 SCW의 거동을 예측할 수 있는 것으로 나타났다. 검증된 수치해석 모델은 동반논문에서 매개변수연구에 활용되었다.

수직관내(垂直管內)를 흘러내리는 액막식(液膜式) 흡수기(吸收器)의 흡수(吸收) 및 열전달특성(熱傳達特性)(제(第)2보(報) 열전달특성(熱傳達特性)) (Characteristics of Absorption and Heat Transfer for Film Falling along a Vertical Inner Tube (2nd. Report, Characteristics of Heat Transfer))

  • 엄기찬;이동호;최국광;카시와기 타카오;서정윤
    • 설비공학논문집
    • /
    • 제5권4호
    • /
    • pp.257-264
    • /
    • 1993
  • This is the second report of a three part study on the absorption and heat transfer characteristics of absorber, the correlation of refrigerating capacity and heating capacity. The 2nd report deals with the heat transfer characteristics of a vertical falling film type absorber of inner copper tube. The solute is LiBr-Water solution(60wt%) and the solvent is water vapor. The film Reynoles numbers are varied in the range of 35~130. The states of LiBr solution at the top of absorber are supercooled liquid and superheated liquid. The results are summarized as follows ; Heat transfer results reveal that for the absorption of falling film, the state of LiBr solution appears to be influential in determining the heat transfer. Thus, for the state of supercooled liquid, heat transfer coefficient decreases with increasing the film Reynolds number, but in the condition of superheated liquid, it increases conversely. The mass transfer coefficients that were presented in the 1st.report and heat transfer coefficients of this paper are presented as the dimensionless correlation. The optimum water flowrate which brings about maximum value of heat flux in the film exists, and that increases with increasing the cooling water temperature.

  • PDF